- Weighing range 1,020 g, readability 0.001 g
- Reproducibility 0.004 g, linearity ± 0.005 g
- Stabilisation time 4 s, USP minimum sample weight 8 g
- Glass draught shield, round weighing pan Ø 115 mm, weighing chamber 174 x 162 x 228 mm
- Touch display, internal automatic adjustment, RS-232 and USB device
- GLP/ISO logging, Net-Total, density determination, weighing with tolerance range
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Kern PDT 1000-3 precision balance 1,020 g / 0.001 g"
The Kern PDT is a precision balance with touch display, force compensation and a stainless steel weighing plate. Six models weigh from 320 g to 6,200 g. Three models have a readability of 0.001 g (1 mg): the PDT 300-3, PDT 600-3 and PDT 1000-3. Three models have a readability of 0.01 g: the PDT 2000-2, PDT 4000-2 and PDT 6000-2. All have RS-232 and USB device as standard, automatic adjustment and a range of functions for documentation. According to Kern, the range of functions qualifies the series for the pharmaceutical industry, among others.
Operation via the touch display
The backlit LCD has digits 20 mm high. According to Kern, the display can be used, for example, to switch the unit or start the adjustment. According to the data sheet, the menu is in English, plus a symbol language. A spirit level and adjustable feet are used for levelling. In addition to the taring function (manual, repeatable), there is a standby function.
Functions for counting, formulating and checking
The PDT counts pieces with the reference piece counts 5, 10, 20, 50 and 100. The minimum unit weight is 10 mg under laboratory conditions and 100 mg under standard conditions for models with a readability of 0.001 g, and 100 mg and 1 g for models with a readability of 0.01 g. In addition, there are percentage determination, density determination and the totalling function Net-Total for formulations. When weighing within a tolerance range, the balance indicates visually and audibly whether a value falls within the range. A statistics function, a peak function and a function for calculating the mean value under unstable weighing conditions are also available.
Data transmission and logging
Weighing data is transmitted to a PC or printer via RS-232 or a USB device. With the Windows Direct function, weighing values are transferred directly via a USB device to a Windows application, without the need for manual data entry. Via the KERN Communication Protocol (KCP), the balance can be queried and remotely controlled from a computer or from CRM and ERP systems. GLP/ISO logging records date, time and ID no. at adjustment and at every weighing. For data integrity, Kern lists support according to U.S. FDA 21 CFR Part 11, for example for weighing result, sample ID, user name and balance ID.
Adjustment
According to the data sheet, the automatic adjustment system reacts to a temperature deviation of 2 °C and a time interval of 4 h. It does not replace a calibration certificate, which is available separately (see below).
Models with and without a draught shield
The three models with a readability of 0.001 g have a round weighing pan (Ø 115 mm) and a glass draught shield. The weighing chamber measures 174 x 162 x 228 mm (W x D x H); with the draught shield fitted, the balance is 360 mm high and weighs approximately 6 kg. The three models with a readability of 0.01 g have a square weighing pan measuring 185 x 185 mm; at around 101 mm, they are considerably flatter and weigh approximately 3.6 kg. Kern specifies a draught shield only for the 0.001 g models. On the underside there is an eyelet for below-balance weighing; according to the data sheet, the hook is included in the scope of delivery.
Typical applications
- Laboratories: weighing and piece counting with documented adjustment
- Pharmaceutical applications: weighing with GLP/ISO protocol and data output with date, time and ID no.
- Quality control: weighing with a tolerance range and display via signal
- Chemical industry: formulations with Net-Total and density determination
- Food industry: percentage determination and piece counting
- Plastics technology: density determination and analysis with statistical function
For weighing in up to 1,020 g where milligrams count, the PDT 300-3, PDT 600-3 and PDT 1000-3 are the models. The stabilisation time is 3 s for the PDT 300-3 and PDT 600-3, and 4 s for the PDT 1000-3. Anyone weighing larger quantities up to 6,200 g at 0.01 g takes the PDT 2000-2, PDT 4000-2 or PDT 6000-2. The PDT 2000-2 has the shortest stabilisation time in the series at 2 s.
Models at a glance
| Model | Weighing range (Max) | Readability (d) | Reproducibility | Linearity | Stabilisation time | Weighing pan | USP minimum sample weight (k = 2, U = 0.1 %) | Minimum unit weight when piece counting (laboratory / normal) |
|---|---|---|---|---|---|---|---|---|
| PDT 1000-3 | 1,020 g | 0.001 g | 0.004 g | ± 0.005 g | 4 s | Ø 115 mm | 8 g | 10 mg / 100 mg |
| PDT 2000-2 | 2,200 g | 0.01 g | 0.03 g | ± 0.03 g | 2 s | 185 x 185 mm | 60 g | 100 mg / 1 g |
| PDT 300-3 | 320 g | 0.001 g | 0.003 g | ± 0.003 g | 3 s | Ø 115 mm | 6 g | 10 mg / 100 mg |
| PDT 4000-2 | 4,200 g | 0.01 g | 0.03 g | ± 0.03 g | 3 s | 185 x 185 mm | 60 g | 100 mg / 1 g |
| PDT 6000-2 | 6,200 g | 0.01 g | 0.03 g | ± 0.05 g | 3 s | 185 x 185 mm | 60 g | 100 mg / 1 g |
| PDT 600-3 | 620 g | 0.001 g | 0.003 g | ± 0.003 g | 3 s | Ø 115 mm | 6 g | 10 mg / 100 mg |
Technical details
These values apply to all models. Deviating values are given in the model table.
| Weighing system | Force compensation |
| Weighing plate | Stainless steel |
| Housing | ABS plastic |
| Display | Touch display, LCD with backlight, digit height 20 mm |
| Menu language | English, plus symbol language |
| Units | including kg, g, ct, lb, oz; mg for PDT 300-3, 600-3, 1000-3 and 2000-2 |
| Internal automatic adjustment | Temperature deviation 2 °C, time interval 4 h |
| Interfaces | RS-232 and USB device, both as standard |
| Power supply | Plug-in mains adaptor, 100 V to 240 V AC, 50 / 60 Hz, with country adaptors for EU, UK, US and CH |
| Dimensions, fully assembled (W x D x H) | 213 x 322 x 360 mm (PDT 300-3, 600-3, 1000-3); 213 x 322 x 101 mm (PDT 4000-2, 6000-2); 213 x 322 x 102 mm (PDT 2000-2, according to the data sheet) |
| Net weight | approx. 6 kg (PDT 300-3, 600-3, 1000-3); approx. 3.6 kg (PDT 2000-2, 4000-2, 6000-2) |
| Ambient temperature | 15 °C to 25 °C |
| Humidity | 15 % to 80 % |
| Storage temperature | -10 °C to +60 °C |
| DAkkS calibration certificate | can be ordered separately, item no. 963-103, 963-127 or 963-104 depending on the model |
| Warranty (manufacturer) | 36 months according to Kern, excluding wear parts |
Scope of delivery
- Kern PDT precision balance with stainless steel weighing plate
- Glass draught shield (PDT 300-3, 600-3 and 1000-3 only)
- Hook for below-balance weighing
- Plug-in mains adaptor with country adaptors for EU, UK, US and CH
Calibration
A DAkkS calibration certificate can be ordered separately: item no. 963-103 for PDT 600-3 and PDT 1000-3, item no. 963-127 for PDT 300-3, PDT 2000-2 and PDT 4000-2, item no. 963-104 for PDT 6000-2. The confirmation of manufacturer specification (969-517) is only available in conjunction with the DAkkS calibration certificate.
Warranty
According to Kern & Sohn, these devices come with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer.
Downloads
Regulatory information
As electrical devices, the balances fall under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.
Individual requirements and procurement service
Ionisers (ABP-A01, YBI-01A) and the dust cover (ABS-A08) for the models with 0.001 g, anti-vibration table (YPS-03), anti-vibration plates (YPS-04, YPS-05), thermal printers (YKC-01, YKH-01), dot-matrix printer (YKG-01), needle printer (YKT-01), RS232 Ethernet converters (YKI-10, YKI-11), RS232 WLAN converter (YKI-12) and the RS-232 interface cable (572-926) are also available. Kern also lists test weights of OIML class E2 in compact form made of polished stainless steel: 316-09 (500 g) for the PDT 600-3, 316-11 (1 kg) for the PDT 1000-3 and 316-13 (5 kg) for the PDT 6000-2. For the PDT 2000-2 there is the Safety Set 315-312-407 with the weights 100 g (M1) and 2000 g (F2). Enquiries are handled via our procurement service.
| Weighing range (Max): | 1.02 kg |
|---|---|
| Readability (d): | 0.001 g |
| Verifiable: | no |
| Design: | PDT 1000-3 · 1.020 g |
| Power supply: | Mains operation |