Weighing & Measurement
Weighing & Measurement brings together measurement and weighing technology for laboratories, workshops and quality assurance. LT Laborhandel offers precision, analytical and counting balances from KERN, hardness testers and coating thickness gauges from SAUTER, laboratory pH meters from WTW, as well as photometers from Macherey-Nagel and viscometers from IKA. You can also find more specialised measurement technology in the subcategories Measurement Technology and Viscometers. Our service team will be happy to advise you on selecting the right equipment.
Promotion
Kern & Sauter End-of-Year Sale
Precision balances, moisture analysers, stereo microscopes and Sauter testing equipment at a special offer price.
Compared with the RRP of Kern & Sohn. Until 31 December 2026.

WTW ProfiLine pH 3110 handheld pH meter, IP67, 2AA110
Whether in the laboratory or out by the water’s edge, a pH meter designed for mobile use must operate reliably even under harsh conditions. The WTW ProfiLine pH 3110 is a robust pocket-sized meter with IP 67 protection, battery operation and a 6-button control panel that can be operated even whilst wearing gloves.IP67 protection rating for field and laboratory useThe housing is IP 67-rated, dust-tight and temporarily waterproof. This means the meter can withstand splash water at the sampling point as well as use in damp laboratory environments. Protection class III also ensures safe low voltage during battery operation.Calibration with AutoCal TEC and AutoRead1-, 2- or 3-point calibration with freely selectable calibration points is available. The AutoCal TEC automatic buffer recognition function independently identifies technical buffers or DIN buffers, whilst the AutoRead function checks the stability of the measured value before it is accepted. An integrated calibration timer reminds the user when the next calibration is due.Measuring ranges and accuracyThe pH measurement range extends from -2.000 to +19.999 pH, with an accuracy of ± 0.1 to ± 0.005 pH depending on the selected resolution (± 1 digit in each case, at a sample temperature of 15 to 35 °C). In addition, the instrument measures mV in the range from -2,000 to +2,000 mV, as well as temperature from -5.0 to +105.0 °C with an accuracy of ± 0.1 K.Operation, memory and battery operationThe device is operated via 6 buttons, which can be used even whilst wearing gloves, and, according to the manufacturer, features a large, clear LCD display. The device stores up to 5,000 GLP entries internally. It is powered by four AA alkaline-manganese batteries, or alternatively by four NiMH rechargeable batteries (without an in-unit charging function), with a runtime of approximately 2,500 operating hours.Typical applicationsMobile pH measurement at water bodies and sampling pointsRoutine measurements in industrial and wastewater laboratoriesField measurements at varying locations thanks to battery operation and IP67 ratingCompact secondary unit alongside fixed measuring stations in the laboratoryA typical scenario is a sampling round at several measurement points: the device remains within easy reach in its case, measures pH and temperature directly on site and stores each measurement value with GLP reference, without the need to carry a mains socket or a laptop.Selecting the right electrodeThe ProfiLine pH 3110 has a DIN connector (coaxial plug according to DIN 19262) for the pH electrode and is supplied as a standalone unit without an electrode. It is compatible with WTW electrodes featuring a DIN connector, such as the SenTix 41 (item no. 103635) or the SenTix 81 precision glass electrode (item no. 103642). If you would like the unit and electrode as a complete set, we offer the ProfiLine pH 3110 Set 2 (item no. 2AA112), which includes the SenTix 41.Technical detailsTypePortable pH/mV meterpH measurement range-2.000…+19.999 pH (depending on range)pH accuracy± 0.1 / ± 0.01 / ± 0.005 pH depending on range, ± 1 digit, at 15…35 °CmV measurement range-1,200.0…+1,200.0 mV / -2,000…+2,000 mVmV accuracy± 0.3 mV / ± 1 mV, ± 1 digitTemperature measurement range-5.0…+105.0 °CTemperature accuracy± 0.1 K, ± 1 digitCalibration1-, 2- or 3-point calibration, AutoCal TEC, AutoRead, calibration timerDegree of protectionIP 67, protection class IIIPower supply4 × 1.5 V AA alkaline-manganese batteries (alternatively 4 × 1.2 V NiMH rechargeable batteries)Operating timeapprox. 2,500 operating hoursData storage5,000 GLP entriesDimensionsapprox. 180 × 80 × 55 mmWeightapprox. 0.4 kgOperating temperature / Storage temperature-10…+55 °C / -25…+65 °CConnectionDIN connector for pH electrode (coaxial plug according to DIN 19262)StandardsCE, IP 67 according to EN 60529, EMC according to EN 61326-1/EN 61000-3-2/EN 61000-3-3/FCC Class A, equipment safety according to EN 61010-1Scope of delivery1 WTW ProfiLine pH 3110 handheld meter in a caseSTP 4 and STP 7 buffer solutions3 mol/l KCl electrolyte top-up solutionQuick start guideBatteriesA pH electrode is not included in the scope of delivery; it must be ordered separately for measurement purposes.Regulatory informationThe ProfiLine pH 3110 is covered by WEEE registration number DE 29884659 held by Xylem Analytics Germany GmbH, a collective registration with the EAR Foundation for the WTW brand.Individual requirements and procurement serviceThe SenTix 41 (item no. 103635) and SenTix 81 (item no. 103642), as well as the technical buffer solutions pH 4.01 (item no. 108706) and pH 7.00 (item no. 108708) are suitable for measurement operation. If you require further accessories or have any questions regarding the appropriate combination, our procurement service will be happy to assist.
IKA ROTAVISC SBS me-vi HELI Complete, 100 to 40,000,000 mPas, ball bearings, electric stand, 0010013683
Anyone who frequently switches between samples during continuous operation, or moves the viscometer between several workstations, needs a bearing system that can withstand daily spindle changes without damage. The ROTAVISC SBS me-vi HELI Complete features SBS ball bearing technology and a motorised HELISTAND stand, which moves the viscometer and rotating body evenly through the sample during measurement. The scope of delivery already includes the complete spindle set for the measurement range 100 to 40,000,000 mPas; the drive, stand and accessories are matched to one another and ready for immediate use.Ball bearings instead of jewel bearingsThe SBS version (Steel Ball Bearing, Suspended) replaces the standard jewel bearings with ball bearing technology. It withstands high sample throughput, frequent spindle changes and harsh environments. Anyone who transports the instrument between multiple workstations or measures many samples per shift in quality control is better served by this design than by the more delicate standard bearing system. The spring torque of the built-in measuring spring is 0.7187 mNm, matching the measuring range of the spindles supplied in the SP set-2 kit.HELISTAND moves the sample during measurementThe motorised HELISTAND stand slowly and smoothly raises and lowers the viscometer, complete with spindle, within the sample, rather than simply allowing it to be immersed in a fixed position. This is suitable for measurements where viscosity varies with immersion depth or where uniform movement is required during the measurement series. The telescopic stroke is 142 mm, the maximum stroke at the boom is 61 mm, and the permissible dynamic load is 3.2 kg. The stand rod has a diameter of 16 mm, and the plug-in coupling for the drive is 12 mm.TFT display with ramp function and graphThe TFT display allows the speed (0.01 to 200 rpm in increments of ±0.01 rpm), timer and measured values to be read and set directly. A digital spirit level assists with alignment before the measurement begins, the ramp function automates recurring test sequences, and the graph function displays the viscosity curve during the measurement. The timer covers a range from 0.017 to 6,000 minutes and operates in both timer and continuous modes. An external temperature sensor can also be connected via PT 100; the resolution of the temperature measurement is 0.1 K, whilst RS 232 and Micro-USB transfer the measurement data to a PC.Calibration and data processingThe device can be calibrated at the measurement station and connected to laboratory software via the serial interface or USB, enabling documented measurement series without the need for manual data transfer. The motor delivers 4.8 W at the output, rotates clockwise as standard and is protected against overload. It is designed for operation at an ambient temperature of 5 to 40 °C with a maximum relative humidity of 80 %; the base vessel holds 600 ml of sample.Typical applicationsThe measurement range and robust design make it well suited to use where many different samples are tested in quick succession.Viscosity determination of Newtonian and non-Newtonian fluids in laboratories and quality controlHigh sample throughput with frequent spindle changes thanks to SBS ball bearingsMeasurements with a rotating body via the motorised HELISTAND standMobile use at different workstations or locationsDocumented measurement series via RS 232 or USB interfaceMeasurement series with external temperature monitoring via the PT-100 connectionTechnical detailsViscosity measurement range100 to 40,000,000 mPasAccuracy (FSR)1 %Repeatability (FSR)0.2 %Spring torque0.7187 mNmSpeed range0.01 to 200 rpmSpeed setting accuracy±0.01 rpmTime setting range0.017 to 6,000 minBase vessel volume600 mlOperating temperature (sample)-100 to 300 °CStandHELISTAND, motorisedStroke of telescopic stand / max. stroke142 mm / 61 mmDynamic load3.2 kgInterfacesRS-232, Micro-USBDimensions (W x H x D)351 x 629 x 372 mmWeight7.1 kgConnected load100 to 240 V, 50/60 Hz, 24 W (standby 0.06 W), 24 V DC, 1,000 mADegree of protectionIP 40 (DIN EN 60529)Scope of deliveryThe drive, stand and spindle set are supplied fully matched in a single package; all components can be reordered individually using their respective ID numbers.1 x ROTAVISC SBS me-vi control1 x HELISTAND, motorised stand (Ident No. 0020116429)1 x T-SP-SET (Ident No. 0025007765)1 x SP set-2, spindle set (Ident No. 0025000329)1 x PT 100.8 temperature sensor (Ident No. 0025000413)1 x protective bracketRegulatory informationThis device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer, IKA, is DE 66784213. Information on the return of old appliances can be found on our page Environment and disposal.Warranty and procurement serviceIKA manufacturer’s warranty: 2 years, extended to 10 years upon registration at ika.com/register within 90 days of purchase. Within the ROTAVISC SBS range, the Complete packages differ primarily in their measurement range and stand. For those seeking the same me-vi range without the motion function, the ROTAVISC SBS me-vi Complete offers the version with a fixed ROTASTAND. For higher-viscosity samples, the ROTAVISC SBS hi-vi I HELI Complete and the ROTAVISC SBS hi-vi II HELI Complete are available, each featuring the same SBS ball bearing system and the same HELISTAND stand. We provide support in selecting the appropriate measurement range and in sourcing further accessories such as spindles or calibration oil via our procurement service.
Macherey-Nagel Compact Photometer PF-12Plus for water analysis, including case and software, 919250
The Macherey-Nagel PF-12Plus compact photometer is an optoelectronic system solution for the precise, mobile and stationary analysis of water, wastewater and environmental samples. As a portable laboratory instrument, this photometer combines filter photometry with a high degree of flexibility, whether used directly at the measuring location or in a traditional laboratory setting. When monitoring critical water parameters, industrial process water flows or municipal sewage treatment works, the accurate and rapid determination of substance concentrations is the primary criterion for documenting and controlling statutory limit values in a traceable way. The optical architecture of the PF-12Plus is based on a long-life xenon flash lamp and a precisely matched sensor system with seven integrated interference filters. This spectral configuration enables reliable coverage of all relevant wavelengths for the evaluation of Macherey-Nagel’s renowned VISOCOLOR® ECO and NANOCOLOR® tube tests. The integrated nephelometric turbidity measurement (NTU-Check) automatically detects interfering turbidity in the sample cuvette during the measurement process and alerts the user to possible measurement errors, an advantage in harsh field conditions. The photometer is designed for easy operation and flexible use under changing environmental conditions. Over 100 pre-programmed methods for common parameters (such as ammonium, nitrate, nitrite, COD, phosphorus or heavy metals) enable direct measurement without time-consuming calibration cycles. The splash-proof housing and intuitive menu navigation via the large, backlit graphic display allow laboratory and service staff to handle it safely. Thanks to flexible power management (optionally via batteries, rechargeable batteries, the integrated USB cable or an external power supply), the instrument can be operated flexibly in the field. For documentation in GLP and GMP environments, the PF-12Plus features an internal data memory for up to 1,000 measurement results, including time, date and sample ID stamps. Via the integrated USB interface, the measurement data can be transferred to the free NANOCOLOR® PC export software. This enables digital archiving, statistical analysis and the convenient creation of certificates of analysis. The simple option to independently verify instrument calibrations using test solutions supports audited quality management systems. Technical details Optics & Photometry Type: Filter photometer with microprocessor control, self-test and auto-calibration Light source: Extremely long-life xenon flash lamp Detector: Silicon photodiode Wavelengths (filters): 345 / 436 / 540 / 585 / 620 / 690 nm plus 860 nm for turbidity measurement Wavelength accuracy: +/- 2 nm Photometric range: +/- 3 Abs Photometric accuracy: +/- 1 % Turbidity measurement: Integrated NTU check (nephelometric at 860 nm, measurement range 1-1,000 NTU) Interfaces, memory & software Data storage: 1,000 measurements (with date, time and sample number, supports documentation in a GLP environment) Interface: USB 2.0 for bidirectional data transfer and power supply Pre-programmed tests: Over 100 pre-programmed methods (VISOCOLOR® ECO and NANOCOLOR®) User-defined methods: Up to 50 freely programmable methods Design & Power supply Display: Backlit graphic display (64 x 128 pixels) Cuvette holder: For round cuvettes with an external diameter of 16 mm (no adapter change required) Power supply: 4 x AA batteries, rechargeable batteries, USB interface or external mains adaptor Housing features: Robust, ergonomic design, splash-proof membrane keypad Dimensions (W x D x H): approx. 215 x 160 x 70 mm Weight: approx. 1.0 kg (including batteries) Scope of delivery 1 x Macherey-Nagel Compact Photometer PF-12Plus base unit 1 x Sturdy carrying case with custom-fit foam insert 1 x Manual / Quick Start Guide (including test instructions) 4 x AA batteries (Mignon) 1 x USB cable for PC connectivity and external power supply 1 x software DVD (NANOCOLOR® data export software also available as a free download) 1 x Calibration cuvette Important note: Reagent test kits (such as NANOCOLOR® or VISOCOLOR® ECO tube tests) are not included in the standard scope of delivery and must be ordered separately according to your specific application. Individual requirements & accessories Reagent kits for the PF-12Plus are available. For standardised, high-precision photometric analyses, we recommend the NANOCOLOR® tube tests (e.g. for COD, total nitrogen, total phosphorus) as well as the VISOCOLOR® ECO test kits. For on-site sample preparation, portable heating blocks (e.g. the NANOCOLOR® VARIO Mini for 12 V vehicle power supply) for the chemical digestion of samples are also available. To ensure the continuous integrity of the metrological chain in your laboratory, test solutions (NANOCONTROL NANOCHECK) for verifying photometric accuracy are also available. Make use of our technical procurement service to tailor your mobile measuring station to your specific requirements.
Kern DAB 200-2 halogen moisture analyser, 200 g / 0.01 g
The Kern DAB 200-2 moisture analyser operates using a halogen quartz glass heating element and covers a weighing range of up to 200 grams, with a readability of 0.01 grams or 0.05 % moisture. The measuring principle is thermogravimetric: the built-in precision balance continuously records the sample weight during drying; the instrument calculates the moisture content from the weight loss and displays the drying curve in real time on the backlit graphic display. Those who regularly test larger quantities, such as grain, animal feed or sewage sludge, will benefit from the higher capacity compared with the smaller sister model, the DAB 100-3. Halogen quartz glass heating element for short drying times A 400-watt halogen quartz glass heating element is housed in the lid. The drying temperature can be set in 1-degree increments from 40 to 199 °C; the stabilisation time until the start of the measurement is 3 seconds. There are three drying programmes to choose from: standard drying, fast drying and gentle drying. The unit can be switched off either automatically as soon as the weight of the sample stops changing, by a timer after a set duration, or manually at the touch of a button. Halogen or infrared: choosing the right heating technology The DAB 200-2 is the halogen version of the DAB series. The Kern DAB 200-2IR with infrared heating is also available. The main difference lies in the maximum achievable drying temperature: for the infrared version, the adjustable range ends at 160 °C, whilst for the halogen version described here, it ends at 199 °C. For those who want to dry samples at temperatures above 160 °C, the DAB 200-2 is suitable. Those who work predominantly at moderate temperatures or prefer a more even, gentler application of heat will find the DAB 200-2IR to be the alternative from the same series. The weighing range, readability and operating concept are identical for both models; the difference lies in the heating technology and the maximum possible temperature. The decision can be made regardless of capacity requirements: even those who need the smaller DAB 100-3 will find the same choice between halogen and infrared with the DAB 100-3IR. Graphic display and memory functions The backlit graphic display, with 14-millimetre-high digits, shows the current moisture content and the drying curve whilst the measurement is in progress. Up to 15 complete drying programmes can be stored in the unit, along with memory slots for 5 measurement results and 5 sample names. The device can be connected to a printer or PC via the RS-232 serial interface to document measurement values. Weighing technology and accuracy The internal balance is designed as a single-range balance with a strain gauge system, with a resolution of 20,000 parts. Reproducibility and linearity are 0.01 grams and ± 0.03 grams respectively. For a measurement uncertainty of 0.1 % at k=2, Kern specifies a minimum sample weight of 20 grams; this is consistent with the moisture content range of 20 to 100 % of the sample for which this model is designed. The aluminium sample pans have a diameter of 92 millimetres; the housing is made of cast aluminium and plastic. Typical applications The DAB 200-2 moisture analyser is used wherever the moisture content needs to be determined quickly and without time-consuming sample preparation, for example in the goods-in department of a grain mill or during routine checks of raw materials prior to further processing. The drying chamber measures 92 mm in diameter and 20 mm in height; Kern specifies a sample size of 1 g to 200 g. Food production and the food industry Water management Energy and raw materials industry Agriculture Selection guide: DAB 100-3 or DAB 200-2 If you are undecided between the two halogen models, the main factors to consider are the weighing range and readability. The table compares the DAB 200-2 and DAB 100-3 side by side, using the manufacturer’s specifications. FeatureDAB 100-3DAB 200-2Weighing range (max)110 g200 gReadability (weight)0.001 g0.01 gReadability (moisture)0.01 %0.05 %Resolution110,000 parts20,000 partsMinimum sample weight (k=2, U=0.1 %)2 g20 g For small, high-value or particularly inhomogeneous samples, where every milligram counts, the DAB 100-3 is the more accurate choice. For larger or heavier samples, where absolute capacity is more important than the last decimal place, the DAB 200-2 remains the more practical option. Both models share the same housing, operating concept and interface, meaning that switching between the two sizes in day-to-day laboratory work does not require any changes to workflows. Operating conditions, materials and warranty The DAB 200-2 is designed for operation at ambient temperatures of 5 to 40 °C and a relative humidity of 5 to 80 %. According to the manufacturer’s specifications, the device contains no substances prohibited under REACH. According to Kern & Sohn, this device comes with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer. Regulatory informationAs an electrical device, the device falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Frequently asked questions about the DAB 200-2 What distinguishes the DAB 200-2 from the DAB 100-3? The DAB 200-2 covers a wider weighing range up to 200 grams, with a readability of 0.01 grams. The DAB 100-3 offers finer measurement, down to 0.001 grams, with a weighing range of up to 110 grams. For small, high-precision samples, the DAB 100-3 is the more accurate choice. What is the difference between the halogen and infrared versions? Both operate on the same thermogravimetric principle. The difference lies in the maximum drying temperature: The halogen version, the DAB 200-2, reaches up to 199 °C, whilst the infrared version, the DAB 200-2IR, reaches up to 160 °C. What is the minimum sample size required? For a measurement uncertainty of 0.1 % at k=2, Kern specifies a minimum sample weight of 20 grams. Can the instrument be connected to a printer or PC? Yes, measurement reports can be transferred to a printer or computer via the RS-232 serial interface. What drying programmes are available? Standard drying, fast drying and gentle drying, with a choice of automatic, time-controlled or manual switch-off. How many sample pans are included in the scope of delivery? The carton contains 50 aluminium sample pans, each with a diameter of 92 millimetres. What power supply does the DAB 200-2 require? Power is supplied via a built-in power supply unit, rated for 230 volts AC and 50 hertz. Technical details Weighing range (max)200 gReadability (weight)0.01 gReadability (moisture)0.05 %Reproducibility0.01 gLinearity± 0.03 gWeighing systemStrain gauge, single-range balanceResolution20,000 partsMinimum sample weight (k=2, U=0.1 %)20 gPossible moisture content of the sample20 % to 100 %Heating methodHalogen quartz glass heating element, 400 WTemperature range40 °C to 199 °C, in 1 °C incrementsStabilisation time3 sDrying programmesStandard drying, fast drying, gentle dryingSwitch-off criteriatime-controlled, automatic, manualProgramme memory15 drying programmesResult memory5 measurementsSample designation memory5DisplayGraphic display, backlit, digit height 14 mmSample pan diameter92 mmHousing materialCast aluminium, plasticWeighing pan materialAluminium (aluminium pans)InterfaceRS-232Power supplyBuilt-in power supply, 230 V AC, 50 HzDimensions (W x D x H)240 x 365 x 180 mmWeight (net)5.0 kgOperating temperature5 °C to 40 °COperating humidity5 % to 80 %Warranty (manufacturer)36 months according to Kern, excluding wear parts Scope of delivery DAB 200-2 moisture analyser 50 sample pans (aluminium) Power supply with mains cable Operating instructions (multilingual) Individual requirements and procurement service The 50 sample pans supplied are sufficient for the first series of measurements; however, it is advisable to keep a stock of spare pans for day-to-day use. The internal balance should be checked regularly using an external test weight. Our procurement service provides support with accessories, spare parts and bespoke enquiries relating to Kern moisture analysers.
WTW ProfiLine pH 3110 Set 2 pH Measurement Kit with SenTix 41, 2AA112
If you don’t want to put together a pH meter and a suitable electrode separately, the WTW ProfiLine pH 3110 Set 2 offers a complete, ready-to-use package in a carrying case. As well as the 2AA110 meter, the set includes the SenTix 41 electrode, along with buffer solution, a stand and a beaker for your first measurements.What’s in the caseThe carrying case contains the ProfiLine pH 3110 meter, the SenTix 41 pH electrode (item no. 103635), STP 4 and STP 7 buffer solutions, a stand, a beaker, the quick start guide and the batteries. This means you can calibrate and take measurements immediately after unpacking, without having to order the electrode, buffers or accessories separately.Measuring instrument with IP67 rating and flexible calibrationThe main unit is technically equivalent to the 2AA110 single-unit model: IP 67 protection rating, 1- to 3-point calibration with AutoCal TEC and AutoRead stability check, integrated calibration timer and 6-button operation, even when wearing gloves. The pH measurement range extends from -2.000 to +19.999 pH, with additional mV and temperature measurement. The unit is powered by 4 AA batteries with a runtime of approx. 2,500 operating hours; it stores up to 5,000 GLP entries internally.SenTix 41 electrode included in the setThe included SenTix 41 has a plastic shaft with a low-maintenance gel electrolyte, a fibre diaphragm and an integrated NTC temperature sensor. It is connected via a 1 m fixed cable with a DIN plug and a 4 mm banana plug, compatible with the meter’s DIN input. The measurement range covers 0 to 14 pH at temperatures between 0 and 80 °C; the membrane resistance is less than 1 GOhm.Typical applicationsImmediate access to pH measurement without the need to purchase separate equipmentMobile use at water bodies and sampling points thanks to the carrying caseEquipping new measuring stations in the laboratory with a full range of accessoriesRoutine measurement in industrial and wastewater laboratoriesAn obvious example is the set-up of a new measurement station: rather than having to assemble the meter, electrode, buffer solution and accessories individually, Set 2 provides a calibration-ready workstation straight out of the case.Difference compared to the 2AA110 single unitThe ProfiLine pH 3110 single unit (item no. 2AA110) is supplied without an electrode and is aimed at customers who already own a suitable SenTix electrode or wish to use another model, such as the SenTix 81 precision electrode (item no. 103642). Set 2 eliminates this intermediate step and provides the meter, electrode, buffer solution and accessories as a complete package.Accessories for immediate useThe stand and beaker included in the case allow for a stable measurement setup directly at the workstation, without the need to organise additional laboratory equipment. The included STP 4 and STP 7 buffer solutions already cover one acidic and one neutral calibration point; for a complete 3-point calibration, an alkaline buffer solution (pH 10) can be added if required.The carrying case protects the measuring instrument, electrode and accessories during transport between sampling points or laboratory workstations and keeps the individual parts organised in one place, rather than having to gather them together separately.Technical detailsTypePortable pH/mV meter with pH electrode included in the setpH measurement range (meter)-2.000…+19.999 pH (depending on range)Degree of protectionIP 67, protection class IIICalibration1-, 2- or 3-point calibration, AutoCal TEC, AutoRead, calibration timerPower supply4 × 1.5 V AA alkaline-manganese batteries (alternatively 4 × 1.2 V NiMH rechargeable batteries)Operating timeapprox. 2,500 operating hoursData storage5,000 GLP entriesDimensions / Weight of unitapprox. 180 × 80 × 55 mm / approx. 0.4 kgElectrode included in the setSenTix 41 (Item No. 103635)Electrolyte for electrodeGel, non-refillableTemperature sensor electrodeNTC 30 kOhm, integratedMeasuring range of pH / temperature electrode0…14 pH, 0…80 °CElectrode connection1 m fixed cable, DIN plug and 4 mm banana plugsStandardsCE, IP 67 according to EN 60529, EN 61010-1 (instrument); CE Declaration of Conformity SenTix/TA-Sensolyt, DIN 19262 (electrode)Scope of delivery1 WTW ProfiLine pH 3110 handheld meter in a carrying case1 SenTix 41 pH electrode (item no. 103635)Buffer solutions STP 4 and STP 7Stand and beakerQuick start guideBatteriesRegulatory informationThe WEEE registration number DE 29884659 held by Xylem Analytics Germany GmbH applies to the instrument component; this is a collective registration with the EAR Foundation for the WTW brand. The SenTix-41 electrode included in the set is a passive sensor without its own electronics and is therefore not affected by this registration.Individual requirements & procurement serviceOnce the buffer solution in the set has been used up, refills of the Technical Buffer Solution pH 4.01 (item no. 108706) and pH 7.00 (item no. 108708) are available. For replacement electrodes, additional accessories or specific enquiries regarding the kit, our procurement service provides support.
IKA ROTAVISC lo-vi Complete Rotational Viscometer Set, low-viscosity media, TFT touchscreen, 0010013826
Anyone who routinely tests low-viscosity liquids such as oils, paints, drinks or aqueous solutions needs a rotational viscometer that is ready to measure straight out of the box, rather than having to search for accessories first. The ROTAVISC lo-vi Complete from IKA comes as a matched set comprising the measuring head, stand, spindle set and temperature probe; with its soft measuring spring, it precisely covers the range in which many laboratory quality controls are carried out: from 1 to 6,000,000 mPas.Rotational principle with a soft measuring spring for low-viscosity mediaThe lo-vi measuring system uses the softest spring in the ROTAVISC series (spring torque 0.0673 mNm) and is therefore designed for low-viscosity to medium-viscosity samples. The viscosity measurement range extends from 1 to 6,000,000 mPas with an accuracy of 1 % of full scale (FSR) and a repeatability of 0.2 % FSR. The rotational speed can be adjusted from 0.01 to 200 rpm in increments of 0.01 rpm, which allows even very flat viscosity curves to be resolved with high precision.TFT touchscreen display with trend graph and timerThe ROTAVISC lo-vi Complete is operated via a TFT touchscreen display, on which speed, torque and temperature are shown simultaneously as setpoint and actual values. An integrated graphing function displays the viscosity curve directly on the instrument, which is useful for identifying shear-thinning or shear-thickening at a glance, without first having to export the measured values to external software. For long measurement series, a timer ranging from 0.017 to 6,000 minutes is available, either in timer mode or continuous operation. A calibration function directly on the device supports measurement accuracy throughout its service life.Temperature-controlled measurement with PT 100As viscosity is highly temperature-dependent, a PT 100.8 temperature sensor is included as standard. It has a resolution of 0.1 Kelvin and, together with the instrument, covers a working temperature range from minus 100 to 300 °C. Users wishing to actively control the temperature of the sample during measurement can utilise an external cooling/heating circulating thermostat from the range of accessories, such as the HRC 2 lite or the CBC VISC lite, which use the natural refrigerant R290. Separate measurement chambers are also available as accessories for sealed or particularly small sample volumes, enabling temperature-sensitive or volatile media to be measured under controlled conditions. An RS-232 interface and a micro-USB port are provided for connection to a process control system or the Labworldsoft 6 laboratory equipment software, allowing measurement series to be documented and analysed even outside the TFT display.Typical applicationsWith its wide measurement range, designed for low to medium viscosities, the ROTAVISC lo-vi Complete is technically suitable for:Quality control of low-viscosity products such as oils, paints, dip coatings or beveragesIncoming goods inspection of raw materials with defined viscosity specificationsRecipe and formulation development in research and developmentIn-process spot-check measurements on low- to medium-viscosity batchesTraining and teaching in rheology, thanks to the clear TFT user interfaceSelection guide within the ROTAVISC rangeIKA offers the ROTAVISC series in several measurement range variants, which differ primarily in terms of the spring stiffness of the measuring head and the spindle set supplied. All of them share the same display, speed range, interfaces and housing:VariantViscosity measurement rangeSpring torqueStandROTAVISC lo-vi Complete, this unit1 to 6,000,000 mPas0.0673 mNmRotastand, manualROTAVISC me-vi HELI Complete100 to 40,000,000 mPas0.7187 mNmHelistand, motorisedROTAVISC hi-vi II Complete800 to 320,000,000 mPas5.7496 mNmRotastand, manualFor most low- to medium-viscosity standard samples in the laboratory, the lo-vi version is suitable. If the viscosity rises into the range of pastes and highly viscous substances, the ROTAVISC hi-vi II Complete is the more suitable option. If controlled up-and-down movement of the spindle is also required, for example with non-flowing or structurally viscous samples, the ROTAVISC me-vi HELI Complete, with its motorised Helistand, is the right addition.Distinction from the CBC series with integrated temperature controlIn addition to the Complete set described here, in which temperature control is provided by an optional external circulating thermostat, IKA offers the CBC series, a variant in which a cooling/heating bath is already permanently integrated into the viscometer. For the low-viscosity measurement range, this corresponds to the ROTAVISC CBC lo-vi Package. Users who regularly carry out measurements at defined, actively controlled temperatures thus avoid the need to set up a separate external bath; those who only occasionally work under temperature-controlled conditions will generally find the Complete Set, combined with an external thermostat such as the CBC VISC lite (which can be added as required), to be the more cost-effective option.Technical detailsViscosity measurement range1 to 6,000,000 mPasAccuracy (FSR)1 %Repeatability (FSR)0.2 %Spring torque0.0673 mNmGuard raillo-viMeasuring spindlesSP set-1 (SP 1 to SP 4)Motor power, output4.8 WMotor direction of rotationclockwise, with overload protectionDisplayTFT touchscreen with graph functionSpeed range0.01 to 200 rpm, setting accuracy ±0.01 rpmTorque display / measurementYesTimer0.017 to 6,000 min, timer and continuous operationWorking temperature-100 to 300 °C, temperature measurement resolution 0.1 KConnection for external temperature sensorPT 100Base vessel volume600 mlStandRotastand, max. stroke 200 mm, Ø 16 mm, dynamic load 5 kgStroke of telescopic stand200 mmInterfacesRS 232, USB (Micro-USB)Degree of protectionIP 40 in accordance with DIN EN 60529Dimensions (W x H x D)351 x 629 x 372 mmWeight7.1 kgConnected load100 to 240 V, 50/60 Hz, 24 WScope of delivery1 x ROTAVISC lo-vi control S000 (measuring head)1 x Rotastand (stand)1 x SP set-1 (standard spindle set SP 1 to SP 4)1 x PT 100.8 (temperature sensor)1 x Guard rail (protective bracket)Use, installation, maintenance and disposalThe device is protected against solid foreign objects from 1 millimetre in size in accordance with degree of protection IP 40; direct contact with splashing water must be avoided. To ensure reproducible measurement results, the stand should be placed on a level work surface with minimal vibration; the guard rail protects the spindle and measuring head from accidental contact during operation. The integrated calibration function allows for regular checks using standard silicone oils from the range of accessories; it is advisable to switch off the power before changing spindles or vessels. Spindles and the measuring vessel should be cleaned thoroughly after each measurement to ensure that dried-on residues do not distort the next measurement. At the end of its service life, the ROTAVISC lo-vi Complete, as an electrical appliance, must not be disposed of with household waste but must be placed in the separate collection for waste electrical and electronic equipment.WarrantyManufacturer’s warranty from IKA: 2 years, extended to 10 years upon registration at ika.com/register within 90 days of purchase.Regulatory informationThis device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer, IKA, is DE 66784213. Information on the return of old appliances can be found on our page Environment and disposal.Individual requirements & procurement serviceAdditional spindles and adaptors, measuring chambers, standard silicone oils for calibration, external circulating thermostats and the Labworldsoft 6 laboratory equipment software are available for the ROTAVISC lo-vi Complete as required. Factory calibration can also be ordered. Through our procurement service, we assist you in putting together the right accessories and selecting from our range of viscometers.Frequently Asked QuestionsWhat is included in the scope of delivery of the ROTAVISC lo-vi Complete?The measuring head, Rotastand, SP set-1 spindle set, PT 100.8 temperature sensor and protective bracket are all included in the scope of delivery.What viscosity range is the instrument designed for?For 1 to 6,000,000 mPas, using the softest measuring spring in the ROTAVISC range for low- to medium-viscosity media.Can the sample be temperature-controlled during the measurement?Yes, using the supplied PT 100 probe and an optional external circulating thermostat from the range of accessories, such as the CBC VISC lite.What is the difference between the lo-vi and hi-vi II models?The hi-vi II Complete measures up to 320,000,000 mPas using a stiffer spring and is therefore designed for pastes and highly viscous media.Can I calibrate the device myself?A calibration function is built in, and suitable standard silicone oils are available as accessories.What interfaces are available for data transfer?RS 232 and Micro-USB, compatible with the Labworldsoft 6 laboratory instrument software.
Sauter JCT 100 coating thickness gauge, Fe/NFe combination sensor, internal measuring cell
The Sauter JCT 100 measures the thickness of paint and coating layers on metallic substrates, with a measuring range of up to 2,000 µm and a readability of 0.1 µm. An internal sensor combines two measuring principles in a single device: magnetic induction for iron and steel (Fe), and eddy current for non-ferrous metals such as aluminium or copper (NFe). The JCT 100 automatically recognises the base material, eliminating the need to switch manually between measuring methods. This provides a handy coating thickness gauge for both material groups, suitable for corrosion protection testing, paint shops or incoming goods inspection. One sensor for ferrous and non-ferrous metals Automatic base material recognition saves time when working with different components, as there is no need to check whether the workpiece is magnetic before each measurement. The tolerance is 2 % of the full-scale range. To ensure reliable measurement, the base material beneath the coating must have a minimum thickness of 300 µm. The shape of the sample also plays a role: for flat surfaces, a very small sample of 10 mm is sufficient; for convex curves, a radius of curvature of at least 1.5 mm is required; and for concave shapes, a radius of at least 50 mm is needed. If you are testing very small or highly curved components, it is best to verify these values in advance using your own workpiece. Operation via traffic-light display and rotatable screen A three-colour LED indicates at a glance whether a measured value lies within the tolerance band (green), falls below a limit value (red) or exceeds it (yellow). For production testing, you can choose between single measurements and repeat measurements with a pass/fail assessment. The device can be adjusted using either one or two points; Sauter calls this single-point and two-point calibration. The display rotates automatically to match the hand’s position and can be locked manually if required. A dedicated automotive mode is provided for vehicle paint inspection, along with voice output. Memory and wireless data transfer The JCT 100 stores up to 55 measurement groups, each containing 60 individual values, internally; this is sufficient for extensive batch testing without the need for interim data retrieval. For further processing, the device transmits data wirelessly to a companion app, which, according to the manufacturer, is available for Android. Typical applications Coating thickness gauges such as the JCT 100 are used wherever an applied paint or anti-corrosion coating must meet a specific thickness requirement, for example after painting a vehicle body or following electroplating. According to Sauter, these include: Automotive industry Electroplating and surface finishing Shipbuilding and aircraft manufacturing Laboratories and quality control Construction and building sites Calibration and warranty According to Kern & Sohn, this device comes with a 2-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer. A warranty extension by a further 3 years to a total of 60 months is available separately (item no. 970-016). A factory calibration certificate is available as an option; according to the manufacturer, the processing time for this is 4 working days (item no. 961-112). According to the manufacturer, the device does not contain any substances prohibited under REACH. Technical details Measuring principleCombination of magnetic induction (Fe) and eddy current (NFe) methods, automatic base material detectionSensorInternal, for ferrous (Fe) and non-ferrous metals (NFe)Measurement rangeup to 2,000 µmReadability0.1 µmTolerance2 % of the full-scale valueMinimum thickness of base material300 µmSmallest sample, flat10 mmSmallest sample, convexRadius of curvature from 1.5 mmSmallest specimen, concaveRadius of curvature from 50 mmUnitsµm, inch (mil)Memory55 measurement groups, each with 60 individual valuesData transferwireless, app for Android (according to the manufacturer)Housing materialPlasticDimensions (W x D x H)152 x 65 x 35 mmWeight (net)0.20 kgWarranty (manufacturer)24 months according to Kern, excluding wear parts Scope of delivery Sauter JCT 100 coating thickness gauge Practical storage box Regulatory informationAs an electrical device, the device falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Individual requirements and procurement service Suitable adjustment foils are available for the regular adjustment of the JCT 100 (item no. ATB-US07). Our procurement service provides support with factory calibration certificates, warranty extensions and bespoke enquiries relating to Sauter measurement technology.
Kern DBS 60-3 halogen moisture analyser, 60 g / 0.001 g (0.01 %), graphic display
The actual moisture content of a raw material or intermediate product often determines the quality of the finished product, whether it be grain, plastic granules or an active pharmaceutical ingredient. The Kern DBS 60-3 moisture analyser measures this value using the traditional drying method directly in the laboratory, with a halogen quartz glass heating element and a single-cell balance accurate to 0.001 g. 400-watt halogen heater The heating element uses halogen-quartz glass and has a power output of 400 watts; the drying temperature can be set in 1-degree increments between 50 °C and 200 °C. The display stabilises within 3 seconds. Four drying programmes cater for different types of samples: standard drying, rapid drying, gentle drying and a staged drying process with several temperature plateaus, for example to expel free surface water separately from chemically bound water. Drying ends automatically based on weight loss, by a set time, or manually at the touch of a button; programmes can optionally be stored in one of 10 programme memory slots for recurring samples. Weighing range and resolution The single-cell balance covers a range up to 60 g; with a resolution of 60,000 parts, it reads in increments of 0.001 g, which corresponds to 0.01 % moisture content. Linearity is ± 0.003 g. This resolution is particularly relevant for small sample weights, for example when only a few grams of an expensive or hard-to-obtain sample are available. The sample dish has a diameter of 95 mm and rests on a stainless steel weighing pan. The moisture content that can be displayed ranges from 0.1 % to 100 %, with the dry matter content corresponding to 100 % to 0.1 %. Documentation and interfaces The backlit graphic display, with 15 mm digit height, shows moisture content, residual weight, temperature and drying time during the measurement. A printer or laboratory PC can be connected via the RS-232 interface; a USB interface is also available. At the end of a measurement, the moisture analyser can print a report containing the date, time and result, formatted according to GLP or ISO conventions. This is a device function, not an external certification. Up to 100 measurement results and 99 sample names can be stored in the instrument, which is useful for routine samples that are analysed on a regular basis. Installation and operation The housing is made of cast aluminium and plastic; the built-in power supply unit operates at 220 to 240 V AC at 50 Hz. The balance operates within the specified range at an ambient temperature of 5 to 40 °C and a relative humidity of 5 to 85 %; it may be stored at temperatures between -10 and 50 °C. Measuring 204 x 336 x 167 mm and weighing 4.6 kg net, the instrument fits on a laboratory bench. According to the manufacturer, the instrument contains no substances prohibited under REACH. Differences from the DAB series Those who require larger weighing capacities and can make do with a lower resolution are better served by the Kern DAB series: the DAB 200-2 covers up to 200 g, but only reads to 0.01 g. Conversely, the DBS 60-3 is designed for smaller weighing ranges up to 60 g with a readability of 0.001 g, when the last decimal place matters. Typical applications In the pharmaceutical industry, moisture measurement is used to determine the residual moisture of active ingredients and excipients. In the food industry, the focus is often on shelf life, for example with cereals, flour or dried products. In research and development, the instrument is used for the rapid testing of new formulations or materials; in the energy and raw materials industries, as well as in water management, it is used to determine the water content of samples from production or treatment processes. Pharmaceutical industry Research and development Water management Food industry Energy and raw materials industry Regulatory informationAs an electrical device, the device falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Frequently asked questions What is the weighing range of the DBS 60-3?Up to 60 g, with a readability of 0.001 g. How quickly does the display stabilise?Within 3 seconds of placing the sample on the balance. Can the measurement result be documented?Yes, via the RS-232 interface to a printer or laboratory PC, optionally as a GLP- or ISO-compliant report. This is a device function, not an external certification. How many drying programmes are there?Four pre-set profiles (Standard, Fast, Gentle, Step) as well as 10 memory slots for your own recurring programmes. How long is the warranty?According to Kern & Sohn, this device comes with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer. Technical details Weighing range (max.)60 gReadability (d)0.001 gLinearity± 0.003 gMoisture readability0.01 %Weighing systemSingle-cellResolution60,000 partsHeating methodHalogen quartz glass heating element, 400 WTemperature range50 to 200 °C, in 1 °C incrementsStabilisation time3 secondsDrying programmesStandard, Fast, Gentle, StagesShut-off criteriaAutomatic, time-controlled, manualProgramme memory10Memory for measurement results100Sample name memory99DisplayGraphic display, backlit, digit height 15 mmSample dish diameter95 mmHousing materialCast aluminium, plasticWeighing pan materialStainless steelInterfacesRS-232, USB (device)Power supplyBuilt-in power supply unit, 220 to 240 V AC, 50 HzDimensions (W x D x H)204 x 336 x 167 mmWeight (net)4.6 kgAmbient temperature (operation)5 to 40 °CHumidity (operating)5 to 85 %Storage temperature-10 to 50 °CWarranty (manufacturer)36 months according to Kern, excluding wear parts Scope of delivery DBS 60-3 moisture analyser 50 sample dishes (aluminium) Protective cover Power supply unit with mains cable Operating instructions (multilingual) Individual requirements and procurement service The 50 aluminium sample dishes supplied will eventually be used up with regular use. For reordering sample dishes, for calibration or for other accessories relating to the DBS 60-3, our procurement service will assist in clarifying your requirements.
Kern precision balance EW 6200-2NM, 6,200 g / 0.01 g, tuning fork weighing system
The Kern EW 6200-2NM is a precision balance with a tuning-fork weighing system, offering a weighing range of up to 6,200 grams with a readability of 0.01 grams. Kern describes it as the classic balance with a robust tuning-fork weighing system. Robust tuning-fork weighing system The EW 6200-2NM operates using a tuning fork weighing system, unlike many precision balances in the Kern range which use strain gauge technology. This design is considered mechanically robust, with stable temperature behaviour and a short stabilisation time of 3 seconds. Reproducibility and linearity are 0.01 grams and ± 0.03 grams respectively, whilst the resolution reaches 620,000 parts. According to Kern, a minimum sample weight of 20 grams is sufficient to achieve a measurement uncertainty of 0.1 % at k=2. External adjustment with the CAL programme The EW 6200-2NM is adjusted externally, using a recommended E2-class test weight of 5 kilograms, guided by the balance’s CAL adjustment programme. Those requiring internal adjustment will find it in Kern’s sister series, the EG-N, which features the same tuning-fork weighing system, with a capacity of up to 4,200 grams and a readability of 0.01 grams. Weighing pan, interface and units The stainless steel weighing pan measures 180 x 160 millimetres; the plastic housing has external dimensions of 180 x 235 x 75 millimetres and a net weight of 3.0 kilograms. Measurement values can be transferred to a printer or PC via the RS-232 interface. An eyelet is available as an option for underfloor weighing. In addition to grams, the EW 6200-2NM also displays dwt, various tael units (Taiwan, Hong Kong, Singapore/Malaysia), ozt, ct, lb, oz, to and mom. Operating conditions and warranty The EW 6200-2NM is designed for ambient temperatures of 10 to 30 °C. According to the manufacturer, it contains no substances prohibited under REACH. According to Kern & Sohn, this device comes with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer. Typical applications Kern cites applications for the EW series ranging from laboratory chemistry to the precious metals trade. Chemists and the chemical industry Gold and precious metals trading Cosmetics industry Laboratory applications In the laboratory, users benefit from the wide range of units of measurement when the same balance is used for various tasks, from formulation to sample preparation. Regulatory informationAs an electrical device, the balance falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Frequently asked questions about the EW 6200-2NM What distinguishes a tuning fork weighing system from a strain gauge system? The tuning fork system is mechanically robust, with stable temperature behaviour and a short stabilisation time of 3 seconds. Can the balance be connected to a printer? Yes, via the RS-232 serial interface. What units of measurement does the balance support? As well as grams, these include dwt, various tael variants, ozt, ct, lb, oz, to and mom. How is the balance adjusted? Externally, using a recommended E2-class test weight of 5 kilograms via the CAL adjustment programme. Technical details Weighing range (max)6,200 gReadability (d)0.01 gReproducibility0.01 gLinearity± 0.03 gMinimum sample weight (k=2, U=0.1 %)20 gResolution620,000 partsStabilisation time3 sWeighing systemTuning forkAdjustmentExternal, recommended adjustment weight 5 kg (E2), CAL adjustment programmeOperating temperature10 °C to 30 °CWeighing pan size180 x 160 mmWeighing pan materialStainless steelHousing dimensions180 x 235 x 75 mmHousing materialPlasticInterfacesRS-232 standardPower supplyMains power supply, 220 V to 240 V AC, 50 Hz; rechargeable battery optional ex worksUnderfloor weighingEyelet (optional)Unitsg, dwt, tl (Tw), tl (HK), ozt, tl (Singapore/Malaysia), ct, lb, oz, to, momWeight (net)3.0 kgWarranty (manufacturer)36 months according to Kern, excluding wear parts Scope of delivery EW 6200-2NM scales Protective cover Power supply unit with adapters for the EU, UK, USA and Switzerland Individual requirements and procurement service A DAkkS calibration certificate (item no. 963-104) can be reordered to document measurement accuracy, on request together with the confirmation of manufacturer specification (item no. 969-517, only in conjunction with the DAkkS calibration certificate). Enquiries about these and other accessory requests relating to Kern precision balances are handled through our procurement service.
Kern DLB 160-3A halogen moisture analyser, 160 g / 0.001 g / 0.01 %, graphic display
The Kern DLB 160-3A moisture analyser has a weighing range of up to 160 g, with a readability of 0.001 g or 0.01 % moisture. A halogen quartz glass heating element dries the sample, whilst the internal balance continuously records the weight loss and displays it in real time on the backlit graphic display. Weighing technology and accuracy The resolution is 160,000 parts, with reproducibility and linearity of 0.001 g and ± 0.003 g respectively. For a sample weight of 10 g, Kern specifies the reproducibility of the moisture reading as 0.05 %; for a sample weight of 2 g, it is 0.15 %. The USP minimum sample weight for a measurement uncertainty of 0.1 % at k=2 is 2 g. The stabilisation time in pure weighing mode is 4 seconds. Halogen heating and drying programmes The halogen quartz glass heating element operates at 400 watts and covers a temperature range from 35 to 160 °C in 1-degree increments. You can choose between standard drying and a fast-drying programme with a switchable preheating stage. In Auto Mode, the unit switches off automatically following a selectable weight loss (0.01 mg/30 s to 10 mg/30 s or 0.1 to 9.9 %/60 s), time-controlled in Time Mode between 1 minute and 12 hours, or manually at the touch of a button. Operation and data logging The backlit graphic LCD display with 11 mm digit height guides the user step-by-step through the measurement; the user interface is available in six languages: German, English, French, Italian, Spanish and Portuguese. Five drying programmes can be stored internally; the log output interval is adjustable between 5 and 250 seconds. Measurement values can be transferred to a printer or PC via the RS-232 interface. Temperature adjustment with optional calibration kit For checking and adjusting the heating temperature, Kern offers the optional DLB-A01N temperature calibration set, comprising a sensor with a separate readout unit. The ‘Tmp test’ service function checks the temperature without altering the setting at a selectable temperature between 35 and 160 °C; after approximately 15 minutes, the value is compared with the reading on the DLB-A01N. The ‘Tmp Adj’ adjustment function operates at two points, factory-set to 80 °C and 150 °C, with the second point having to be at least 30 °C above the first. The heating phase takes approximately 15 minutes per point, after which the adjustment is carried out using the device’s navigation keys to match the DLB-A01N display. The procedure is documented in the operating instructions and, in addition to the mass calibration certificate, can be backed up with a separate ISO temperature calibration (item no. 964-305). Weighing pan and housing The weighing pan has a diameter of 100 mm; the drying chamber above it also has a diameter of 100 mm and a height of 12 mm. The housing is made of plastic. Position within the Kern range The Kern DBS 60-3 is also available, a moisture analyser with a single-cell weighing system, a 60 g weighing range, 0.001 g readability, a temperature range of 50 to 200 °C, four drying profiles, and RS-232 and USB interfaces. The DBS 60-3 therefore has the same readability as the DLB 160-3A, but a smaller weighing range, a temperature range up to 200 °C and, in addition, a USB interface. Typical applications Moisture analysers such as the DLB 160-3A are used wherever the moisture content needs to be checked quickly and without the need for an external laboratory, for example during the incoming goods inspection of raw materials. Food production and the food industry Agriculture and the grain industry Plastics and raw materials industry Regulatory informationAs an electrical device, the device falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Frequently asked questions about the DLB 160-3A What is the weighing range of the DLB 160-3A?Up to 160 g, with a readability of 0.001 g or 0.01 % moisture. What is the maximum drying temperature that can be set?Between 35 and 160 °C, in 1-degree increments. How can the heating temperature be checked or adjusted?Using the optional DLB-A01N temperature calibration kit and the ‘Tmp test’ and ‘Tmp Adj’ service functions, with factory-set points at 80 °C and 150 °C. How many sample dishes are included?10 aluminium sample dishes, 90 mm in diameter. How long is the warranty?According to Kern & Sohn, this device comes with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer. Technical details Weighing range (max.)160 gReadability (weight)0.001 gReadability (moisture)0.01 %Reproducibility (weighing mode)0.001 gReproducibility of moisture content for a 10 g sample0.05 %Reproducibility of moisture content for a 2 g sample0.15 %Linearity± 0.003 gMinimum sample weight (k=2, U=0.1 %)2 gResolution160,000 partsStabilisation time (weighing mode)4 secondsAdjustment (mass)External, recommended adjustment weight 100 g (E2), calibration point 100 gDrying programmesStandard drying, rapid drying with preheating stageSwitch-off criteriaAuto Mode, Time Mode (1 min to 12 h), manualReport output interval5 to 250 seconds, adjustableHeating methodHalogen quartz glass radiant heater, 400 WTemperature range35 to 160 °C, in 1 °C incrementsDisplayGraphic LCD display, backlit, digit height 11 mmUser interface6 languages (DE, EN, FR, IT, ES, PT)Weighing pan sizeØ 100 mmDrying chamberØ 100 mm, 12 mm highProgramme memory5 drying programmesHousing materialPlasticInterfaceRS-232Housing dimensions (W x D x H)215 x 345 x 235 mmPackaging dimensions280 x 450 x 400 mmWeight (net)4.8 kgWeight (gross)7 kgAmbient temperature (operation)5 to 40 °CHumidity (operating)45 to 75 %, non-condensingWarranty (manufacturer)36 months according to Kern, excluding wear parts Scope of delivery DLB 160-3A moisture analyser 10 sample dishes (aluminium, Ø 90 mm) Mains cable Connection cable ‘balance / heating attachment’ Operating instructions Individual requirements and procurement service The 10 aluminium sample dishes supplied are sufficient for the first series of measurements; a pack of 80 is available for subsequent purchase. In addition, there are glass fibre filter circles in packs of 100, the optional DLB-A01N temperature calibration kit, and a thermal printer or a dot matrix printer for the long-term archiving of measurement reports on standard paper. A protective working cover is available as a set of 5 for replacement. Our procurement service provides support for the DAkkS mass calibration certificate (963-127), the ISO temperature calibration (964-305) and other accessories for the DLB 160-3A.
Kern ABT 100-5NM analytical balance, 101 g / 0.01 mg, automatic internal adjustment
The Kern ABT 100-5NM is an analytical balance with a weighing range of 101 g and a readability of 0.00001 g, i.e. 0.01 mg or 10 µg. The balance adjusts itself internally: whenever the temperature changes by 0.5 °C and, in addition, on a timed basis every 4 hours.Reading ten microgramsReproducibility 0.00005 g, linearity ± 0.00015 g, minimum load 0.001 g. Kern specifies the minimum weight according to USP as 100 mg. The balance operates with a single cell; the warm-up time is 8 hours, and the stabilisation time under laboratory conditions is 10 seconds. The housing is made of metal, and the weighing pan is made of stainless steel. A spirit level and adjustable screw feet are included. Kern specifies an operating range of 10 °C to 30 °C ambient temperature and 20 % to 80 % humidity.Internal adjustmentThe balance is adjusted using an internal weight, either automatically or manually. Each adjustment can be printed out as a report for documentation in a GLP environment at the touch of a button; the balance’s identification number is a four-digit code that can be freely programmed and is included in the adjustment report. For checking with external weights, Kern offers the Safety Set 315-107-103 (5 g E2, 100 g E2). A DAkkS calibration certificate is available under item no. 963-101.Dosing and formulationThe high-stability mode and additional filter settings are available to assist with dosing. The combined tare/print function simplifies formulation and documentation; the components of a formulation are automatically numbered and printed with their number and weight value. After each time the balance comes to a standstill, a value is automatically sent to a PC or printer. When counting pieces, the minimum piece weight is 1 mg; under laboratory conditions, it is 0.1 mg. Grams and carats are available as weighing units.Glass draught shieldA large glass draught shield with three sliding doors is included with the balance. Its internal dimensions are 200 x 240 x 260 mm and its external dimensions are 217 x 356 x 338 mm. The stainless steel weighing pan has a diameter of 80 mm. To prevent electrostatic build-up, Kern offers the YBI-01A and ABP-A01 ionisers; for gemstones, the AEJ-A05 aluminium tray is available.Connections and powerRS-232 is fitted as standard; the 770-926 interface cable connects the balance to an external device. Also available are the YKI-02 Bluetooth adapter, an RS-232/USB converter (AFH 13), Ethernet and Wi-Fi converters (YKI-10, YKI-11, YKI-12) and four printers (YKG-01, YKH-01, YKC-01, YKT-01). The power supply accepts 110 to 230 V AC and is supplied with adaptors for Australia, Switzerland, the EU, the UK and the USA.Typical applicationsWeighing from 1 mg minimum load with 0.01 mg readability up to 101 gFormulations with numbered ingredients and printoutDocumentation in a GLP environment with adjustment report and balance identification numberWeighing of gemstones in caratsDosing with high-stability modeThe Kern ADB 200-4 is available with a weighing range of 220 g, a readability of 0.0001 g and external adjustment. For weighings up to 620 g with a readability of 0.001 g, the Kern PNJ 600-3M is available.Frequently asked questionsHow is the ABT 100-5NM adjusted?Using an internal weight, automatically when the temperature changes by 0.5 °C and every 4 hours, or manually.How long does the balance need to warm up?The warm-up time is 8 hours.Can the balance print out an adjustment report?Yes, a report for documentation in a GLP environment at the touch of a button, with a four-digit, freely programmable balance identification number.Which mains plugs are included?Adapters for Australia, Switzerland, the EU, the UK and the USA.How long is the warranty?According to Kern & Sohn, this device comes with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer.Technical detailsWeighing range (max)101 gReadability (d)0.00001 gReproducibility0.00005 gLinearity± 0.00015 gMinimum load (Min)0.001 gMinimum weight (USP)100 mgTare range101 gStabilisation time (laboratory conditions)10 sWarm-up time8 hWeighing systemSingle CellWeighing unitsg, ctMinimum piece weight1 mg, 0.1 mg under laboratory conditionsWeighing panStainless steelWeighing pan (diameter) Ø 80 mmDraught shield, internal (W x D x H)200 x 240 x 260 mmDraught shield, external (W x D x H)217 x 356 x 338 mmDisplayDigit height 14 mmAdjustmentinternal, automatic and manualInterfaceRS-232 as standardInput voltage110 V to 230 V AC, mains power supplyAmbient temperature10 °C to 30 °CHumidity20 % to 80 %HousingMetalWeight (net)8 kgScope of deliveryABT 100-5NM analytical balance with glass draught shieldMains power supply with mains adaptors for Australia, Switzerland, the EU, the UK and the USAProtective working coverRegulatory informationAs an electrical device, the balance falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Individual requirements and procurement serviceKern offers test weights, ionisers, a gemstone dish, the YDB-03 universal density set, anti-vibration tables and anti-vibration plates, as well as interface cables, converters and printers for the ABT 100-5NM. We can advise you on your selection. Enquiries are handled through our procurement service.
Sauter TB 200-0.1US-RED ultrasonic material thickness gauge, external, reduced material catalogue
The Sauter TB 200-0.1US-RED measures the thickness of components using the ultrasonic pulse-echo method, with an external probe for hard-to-reach measurement points. The measuring range extends from 1.5 to 200 mm with a readability of 0.1 mm. According to Sauter, the suffix ‘RED’ stands for a reduced measuring range: the device measures only 11 pre-programmed materials, including steel, cast iron, aluminium, copper and PVC. Reduced material catalogue: what RED means According to Sauter, ‘RED’ stands for a reduced measurement range. According to the manufacturer, the device can analyse only the following materials: cast iron, aluminium, copper, brass, zinc, quartz glass, polyethylene, PVC, grey cast iron, ductile cast iron and steel. Anyone wishing to measure materials outside this list will need the sister model, the Sauter TB 200-0.1US, which does not have the RED restriction. According to the manufacturer, the measurement range, readability, probe frequency and probe diameter are identical for both variants. The list of materials is the difference named by the manufacturer. External probe for hard-to-reach areas The 8 mm measuring head, with a test frequency of 5 MHz, is connected to the unit via a 0.9-metre-long cable. This allows it to be positioned even in places where the unit itself cannot fit. The tolerance is 0.5 % of the full-scale value of the measuring range, which corresponds to ± 1 mm for a 200 mm measuring range; the display can be set to millimetres or inches. Battery operation The TB 200-0.1US-RED runs on 4 standard AA-size alkaline-manganese batteries, which are included in the scope of delivery. Designed for ambient temperatures of 0 to 50 °C, the device can also be operated in workshop conditions without air conditioning; it should be stored at temperatures between minus 10 and 40 °C. An auto-power-off function conserves battery life during measurement breaks. Base plate for on-site adjustment The base plate included in the scope of delivery is used to adjust the measuring head before a new series of measurements begins. Typical applications Wall thicknesses on pipework, tanks, sheet metal or castings can be tested with the TB 200-0.1US-RED without opening or damaging the component, for example to detect corrosion or material loss at an early stage. According to Sauter, these include: Metalworking and mechanical engineering Oil and gas industry Aerospace engineering Plastics engineering Shipping CE marking, calibration and warranty According to the manufacturer’s data sheet, the device bears the CE marking. According to Kern & Sohn, this device comes with a 2-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer. A warranty extension by a further 3 years to a total of 60 months is available separately (item no. 970-015). A factory calibration certificate is available as an option, with a processing time of 4 working days (item no. 961-113). Technical details Measuring principleUltrasonic pulse-echo method, external probeMeasurement range1.5 to 200 mmReadability0.1 mmTolerance0.5 % of the full-scale value (± 1 mm at 200 mm)Unitsmm, inchMaterials that can be analysed (RED)Cast iron, aluminium, copper, brass, zinc, quartz glass, polyethylene, PVC, grey cast iron, ductile cast iron, steel (11 pre-set materials)Probe frequency5 MHzProbe diameter8 mmProbe cable length0.9 mPower supply4 x 1.5 V alkaline-manganese batteries, size AA (included in the scope of delivery)Housing materialPlasticHousing dimensions (W x D x H)161 x 68 x 32 mmWeight (net)0.30 kgOperating temperature0 °C to 50 °CStorage temperature-10 °C to 40 °CCE markingYesWarranty (manufacturer)24 months according to Kern, excluding wear parts Scope of delivery Operating instructions Batteries, 4 x 1.5 V AA External probe, diameter 8 mm Ultrasonic contact gel Base plate for adjusting the probe Sturdy carrying case Regulatory informationAs an electrical device, the device falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Individual requirements and procurement service A replacement is available for the device’s standard probe (item no. ATB-US06, 5 MHz, diameter 8 mm), as well as probes in other diameters (item no. ATB-US01, 6 mm, and item no. ATB-US02, 12 mm) and refills for the ultrasonic contact gel (item no. ATB-US03). Our procurement service provides support with factory calibration certificates, warranty extensions and bespoke enquiries relating to Sauter measurement technology.
Kern DAB 100-3 halogen moisture analyser, 110 g / 0.001 g
The Kern DAB 100-3 moisture analyser is the high-resolution model in the Halogen DAB series, with a weighing range of up to 110 grams and a readability of 0.001 grams or 0.01 % moisture. As with the larger DAB 200-2, the instrument operates on a thermogravimetric principle: the internal balance continuously records the sample weight during drying; the instrument calculates the moisture content from the weight loss and displays the drying curve in real time on the screen. For small or high-value samples, where every milligram counts, the finer readability is immediately noticeable compared with the larger sister model. Halogen quartz glass heating element for short drying times As with the DAB 200-2, the lid houses a 400-watt halogen quartz glass heating element. The drying temperature can be set in 1-degree increments from 40 to 199 °C; it takes just 3 seconds for the temperature to stabilise before the actual measurement begins. You can choose between the drying programmes ‘Standard drying’, ‘Fast drying’ and ‘Gentle drying’; the unit switches off automatically when a constant weight is reached, either by a timer or manually. Halogen or infrared: choosing the right heating technology The DAB 100-3 is the halogen version of the DAB series. The Kern DAB 100-3IR (item no. lt-23263) with infrared heating is also available. The difference lies in the maximum achievable drying temperature: the infrared version reaches a maximum of 160 °C, whilst the halogen version described here reaches 199 °C. For samples that require higher temperatures to ensure thorough drying, the DAB 100-3 is suitable. Those who can manage with more moderate temperatures or prefer a gentler application of heat will find the DAB 100-3IR to be the alternative from the same series, with an identical weighing range and identical readability. The same choice between halogen and infrared is also available for the larger DAB 200-2 and its counterpart, the DAB 200-2IR (item no. lt-23265), should the higher weighing range be more important than high readability. Graphical display and memory functions The backlit LCD graphic display, with 14-millimetre-high digits, shows the moisture content and drying curve whilst the measurement is in progress. The internal memory can store up to 15 drying programmes, plus 5 memory slots for measurement results and 5 for sample names. Measurement values can be transferred to a printer or PC via the RS-232 interface. Weighing technology and accuracy The balance is designed as a single-range balance with a strain gauge system, with a resolution of 110,000 parts, more than five times the resolution of the DAB 200-2. Reproducibility and linearity are 0.001 grams and ± 0.003 grams respectively. According to Kern, a minimum sample weight of 2 grams is sufficient to achieve a measurement uncertainty of 0.1 % at k=2, making the instrument suitable for use with small or limited sample quantities. As with the DAB 200-2, the aluminium sample pans have a diameter of 92 millimetres; the housing is made of cast aluminium and plastic. Typical applications The DAB 100-3 is suitable wherever small sample quantities need to be tested for moisture content quickly and with high resolution, for example during the incoming inspection of raw materials in small batches or for release testing in the laboratory. The low minimum sample weight of 2 grams allows reliable results, even when only a small amount of sample material is available. Food production and the food industry Water management Energy and raw materials industry Agriculture Selection guide: DAB 100-3 or DAB 200-2 Within the Halogen DAB series, the DAB 100-3 and DAB 200-2 differ primarily in terms of weighing range and readout accuracy. The following table compares both models using the manufacturer’s specifications. FeatureDAB 100-3DAB 200-2Weighing range (max)110 g200 gReadability (weight)0.001 g0.01 gReadability (moisture)0.01 %0.05 %Resolution110,000 parts20,000 partsMinimum sample weight (k=2, U=0.1 %)2 g20 g For small, high-value or particularly inhomogeneous samples, where every milligram counts, the DAB 100-3 remains the more accurate choice. Those who regularly test larger or heavier samples will find the DAB 200-2 (item no. lt-23264) to be a suitable alternative with a higher capacity. Both models share the same housing, operating concept and interface, so switching between the two sizes does not alter your usual workflow. Operating conditions, storage and warranty The DAB 100-3 is designed for operation at ambient temperatures of 5 to 40 °C and a relative humidity of 5 to 80 %. For storage outside of operation, for example during transport or in stock, Kern specifies a temperature range of minus 10 to 40 °C. According to the manufacturer’s specifications, the unit contains no substances prohibited under REACH. According to Kern & Sohn, this device comes with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer. Regulatory informationAs an electrical device, the device falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Frequently asked questions about the DAB 100-3 What distinguishes the DAB 100-3 from the DAB 200-2? The DAB 100-3 measures more finely, with a readability of 0.001 grams across a weighing range of up to 110 grams. The DAB 200-2 (item no. lt-23264) covers a wider weighing range up to 200 grams, with a readability of 0.01 grams. What is the difference between the halogen and infrared versions? Both versions operate on the same thermogravimetric principle. The difference lies in the maximum drying temperature: the DAB 100-3 reaches up to 199 °C, whilst the infrared version, the DAB 100-3IR (item no. lt-23263), reaches up to 160 °C. What is the minimum sample size? For a measurement uncertainty of 0.1 % at k=2, Kern specifies a minimum sample weight of 2 grams. Can the instrument be connected to a printer or PC? Yes, measurement reports can be transferred to a printer or computer via the RS-232 serial interface. What drying programmes are available? Standard drying, fast drying and gentle drying, with automatic, time-controlled or manual switch-off. How many sample pans are included? 50 aluminium sample pans, each 92 millimetres in diameter, are included in the scope of delivery. What power supply does the DAB 100-3 require? The unit has a built-in power supply for 230-volt AC at 50 hertz. Technical details Weighing range (max)110 gReadability (weight)0.001 gReadability (moisture)0.01 %Reproducibility0.001 gLinearity± 0.003 gWeighing systemStrain gauge, single-range balanceResolution110,000 partsMinimum sample weight (k=2, U=0.1 %)2 gPossible moisture content of the sample20 % to 100 %Heating methodHalogen quartz glass heating element, 400 WTemperature range40 °C to 199 °C, in 1 °C incrementsStabilisation time3 sDrying programmesStandard drying, fast drying, gentle dryingSwitch-off criteriatime-controlled, automatic, manualProgramme memory15 drying programmesResult memory5 measurementsSample designation memory5DisplayLCD graphic display, backlit, digit height 14 mmSample pan diameter92 mmHousing materialCast aluminium, plasticWeighing pan materialAluminium (aluminium pans)InterfaceRS-232Power supplyBuilt-in power supply, 230 V AC, 50 HzDimensions (W x D x H)240 x 365 x 180 mmWeight (net)5.0 kgOperating temperature5 °C to 40 °COperating humidity5 % to 80 %Storage temperature-10 °C to 40 °CWarranty (manufacturer)36 months according to Kern, excluding wear parts Scope of delivery DAB 100-3 moisture analyser 50 sample pans (aluminium) Mains cable with Euro plug Operating instructions (multilingual) Individual requirements and procurement service The 50 aluminium sample pans supplied are sufficient for the first series of measurements; for frequent use, it is worth reordering suitable replacement pans. An external test weight is recommended for regular checking of the internal balance. Our procurement service provides support with accessories, spare parts and bespoke enquiries relating to Kern moisture analysers.
Sauter Leeb hardness tester HK-DB for metals, portable hardness tester
The Sauter HK-DB is a portable hardness tester for metals based on the Leeb method. It measures directly on the workpiece, not in the laboratory, and covers a range from 170 to 960 HLD. The type D rebound sensor is connected to the evaluation unit via a cable and is included in the scope of delivery. If a large or heavy component cannot be transported for hardness testing, the tester is taken to the component.How the Leeb hardness test worksIn the Leeb method, a test body strikes the surface; the hardness is determined from the rebound velocity. The measurement result is initially given on the Leeb scale. The HK-DB uses the HLD scale, where the ‘D’ stands for the sensor type. The device automatically converts the result into other hardness units. According to the data sheet, these are HL, HV, HB, HRB and HRC.Measurement in any orientationThe device automatically compensates for the direction of the test. It measures in all directions (360°), including sideways and overhead. The connected rebound sensor is automatically detected. The sensor is 14.6 cm long and has a diameter of 2 cm. The test specimen must weigh at least 2 kg and have a thickness of at least 3 mm. The tolerance is 1 %, and the readability is 1 HL.Storage and analysisThe internal memory can store up to 600 measurement groups, each containing up to 32 individual readings. The device calculates the average from the values in each group. A mini-statistics display shows the measured value, average value, measurement direction, date and time. The limit value function allows an upper and a lower limit to be programmed; the device signals any exceedances with an audible and visual alert. The graphic LCD is backlit and features 11 mm high digits; the display brings together all key functions on a single screen. Data is transferred from the device via USB; the USB cable is also available.Housing, batteries, caseThe evaluation unit is housed in a cast aluminium casing measuring 132 x 82 x 31 mm and weighs approximately 0.45 kg net. Two AA batteries (1.5 V) provide power for around 200 hours; the batteries are included. The unit is supplied in a carrying case.Hardness reference blockThe scope of delivery includes a hardness reference block with a hardness of approximately 800 HLD. It serves as a reference value for checking the instrument before a series of tests. Additional hardness reference plates of 790, 630 and 530 HL are also available.Typical applicationsAutomotive industry: checking the hardness of shafts, gears and castingsMetalworking and steel construction: incoming goods testing of semi-finished products and componentsEnergy and power station industry: On-site testing of large componentsOil and gas industry: hardness testing of plant componentsAerospace: testing of components that cannot be transported to a laboratorySelection guide: Sensor type and test objectThe HK-DB is supplied with the type D sensor. Other rebound sensors, namely type C, type D+15, type DL and type G, are also available. The type best suited to the testing task depends on the component’s shape and material. We would be happy to advise you on your selection.Regulatory informationAs an electrical device, the device falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Frequently asked questionsWhat materials is the device designed for?For metals, as the name suggests. The measuring range is 170 to 960 HLD.How heavy does the test specimen need to be?The minimum weight is 2 kg, and the minimum thickness is 3 mm.Is a USB cable included?No, the cable is also available separately. The device is fitted with a USB port.Can I take measurements in any direction?Yes, the device automatically compensates for the test direction and measures over 360°.How do I check the device?Using the supplied hardness reference block, with a hardness of approximately 800 HLD.How long is the warranty?According to Kern & Sohn, this device comes with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer.Technical detailsMeasuring range170 to 960 HLDHardness scaleHLD (Leeb)Readability1 HLTolerance1 %Units (conversion)HL, HV, HB, HRB, HRCSensorexternal, Type D rebound sensorSensor dimensionsLength 14.6 cm, Ø 2 cmMinimum weight of test specimen2 kgMinimum thickness of test specimen3 mmTest direction360°, automatic compensationMemory600 groups, each with up to 32 individual valuesInterfaceUSB deviceDisplayGraphic LCD, backlit, digit height 11 mmHousing (W x D x H)132 x 82 x 31 mm, cast aluminiumPower supply2 x 1.5 V AAOperating timeapprox. 200 hNet weightapprox. 0.45 kgScope of deliverySauter HK-DB evaluation unitExternal rebound sensor, type DHardness reference block (approx. 800 HLD)BatteriesCarrying caseIndividual requirements and procurement serviceAdditional rebound sensors, hardness reference plates, adapter rings and the USB cable are also available, as well as factory calibration certificates for the instrument and the reference block. Enquiries are handled via our procurement service.
Kern FFN stainless steel bench balances IP65, weighing range 1.5 kg to 25 kg, readability 0.2 g to 10 g, with rechargeable battery
The Kern FFN is a stainless steel bench balance with IP65 dust and splash protection for use in the food, pharmaceutical and chemical industries. This protection applies only when operating on rechargeable battery power. Ten models weigh from 1.5 kg to 25 kg, with a readability range from 0.2 g to 10 g. Kern describes the housing and weighing plate as being made of stainless steel; the plate measures 233 x 193 mm. An internal rechargeable battery and the power supply are included. Grip recesses on the underside make carrying easier.Hygiene and protectionKern states that the balance is suitable for the heightened hygiene requirements in the food, pharmaceutical and chemical industries, as well as for harsh industrial use. The smooth stainless steel surfaces are easy to clean. Kern also states that the FFN supports a quality system in line with HACCP. The complete unit is protected to IP65. The ambient temperature may be between -10 °C and 40 °C.Ten models, five of which have a conformity assessmentThere are two versions available for each weighing range. The models ending in N (FFN 1K-4N, 3K0.5IPN, 6K1IPN, 15K2IPN, 25K5IPN) have a finer readability and display kg and lb. The models with an M (FFN 1K-4NM, 3K1IPM, 6K2IPM, 15K5IPM, 25K10IPM) are intended for conformity assessment under the NAWI Directive (2014/31/EU). Their readability corresponds to the verification value; the resolution is 2,500 to 3,000 steps; the units are kg and g.Operation and batteryThe balance is operated using three keys, and the backlit LCD display features digits 25 mm high. The internal lead-acid rechargeable battery is included and, according to Kern, runs for up to 50 h without backlight with a charging time of 12 h (30 h with backlight). The plug-in mains adaptor (110 V to 230 V AC) comes with adaptors for EU, UK, US and CH. For the FFN 3K1IPM, 6K2IPM, 15K5IPM and 25K10IPM models, the automatic switch-off function in rechargeable battery mode can be set to 3 min, 5 min or 15 min, or disabled. At around 4 kg the balance is portable, helped by the grip recesses on the underside.Typical applicationsFood industry and hygiene areas: weighing ingredients and batches, wiping down stainless steel surfacesPharmaceutical applications: weighing in production, with conformity assessment ex works if neededChemical industry: weighing materials in splash water environmentsKitchen, canteen, retail area and food laboratory: changing locations thanks to rechargeable battery operationWeighings subject to verification: with the M models and conformity assessment ex worksModels at a glanceModelWeighing range (Max)Readability (d)ReproducibilityLinearityResolution (steps)Recommended adjustment weightUnitsFFN 1K-4N1.5 kg0.2 g0.2 g± 0.4 g7,5001.5 kg (M1)kg, lbFFN 1K-4NM1.5 kg0.5 g0.5 g± 0.5 g3,0001.5 kg (M1)kg, gFFN 3K0.5IPN3 kg0.5 g0.5 g± 1 g6,0003 kg (M3)kg, lbFFN 3K1IPM3 kg1 g1 g± 1 g3,0003 kg (M3)kg, gFFN 6K1IPN6 kg1 g1 g± 1 g6,0006 kg (M3)kg, lbFFN 6K2IPM6 kg2 g2 g± 2 g3,0006 kg (M3)kg, gFFN 15K2IPN15 kg2 g2 g± 4 g7,50015 kg (M3)kg, lbFFN 15K5IPM15 kg5 g5 g± 5 g3,00015 kg (M3)kg, gFFN 25K5IPN25 kg5 g5 g± 10 g5,00025 kg (M3)kg, lbFFN 25K10IPM25 kg10 g10 g± 10 g2,50025 kg (M3)kg, gThe M models in the conformity assessment:ModelVerification value (e)Minimum load (Min)Accuracy classitem no. conformity assessmentFFN 1K-4NM0.5 g10 gIII965-227FFN 3K1IPM1 g20 gIII965-227FFN 6K2IPM2 g40 gIII965-228FFN 15K5IPM5 g100 gIII965-228FFN 25K10IPM10 g200 gIII965-228Technical detailsThese values apply to all models. Deviating values are given in the model tables.Weighing systemStrain gaugeStabilisation time2 sDegree of protectionIP65 (rechargeable battery operation only)Weighing plateStainless steel, 233 x 193 mmHousingStainless steel, plastic, 243 x 300 x 127 mm (W x D x H)DisplayLCD with backlight, digit height 25 mmOperation3 keysAdjustmentexternal; for weights, see model tableRechargeable batteryLead, internal, charging time 12 h, operating time up to 50 h without and 30 h with backlight, in the scope of deliveryPower supplyPlug-in mains adaptor, 110 V to 230 V AC, with adaptors for EU, UK, US and CHNet weightapprox. 4.0 kgAmbient temperature-10 °C to 40 °CConformity assessment under NAWI (2014/31/EU)M models only, optional ex works, item no. 965-227 for FFN 1K-4NM and FFN 3K1IPM, item no. 965-228 for FFN 6K2IPM, FFN 15K5IPM and FFN 25K10IPMDAkkS calibration certificatecan be ordered separately, item no. 963-127 (1K-4N, 1K-4NM, 3K0.5IPN, 3K1IPM); item no. 963-128 (6K1IPN, 6K2IPM, 15K2IPN, 15K5IPM, 25K5IPN, 25K10IPM)Warranty (manufacturer)24 months according to Kern, excluding wear partsScope of deliveryKern FFN stainless steel bench balance with internal rechargeable batteryPlug-in mains adaptor with adaptors for EU, UK, US and CHConformity assessment and calibrationA conformity assessment under the NAWI Directive (2014/31/EU) is optionally available for models with an M: item no. 965-227 for FFN 1K-4NM and FFN 3K1IPM, item no. 965-228 for FFN 6K2IPM, FFN 15K5IPM and FFN 25K10IPM. It can only be ordered ex works together with the balance; according to Kern, a subsequent conformity assessment is not possible. To place an order, Kern needs the full address of the installation site. A DAkkS calibration certificate can be ordered separately: item no. 963-127 for FFN 1K-4N, FFN 1K-4NM, FFN 3K0.5IPN and FFN 3K1IPM; item no. 963-128 for FFN 6K1IPN, FFN 6K2IPM, FFN 15K2IPN, FFN 15K5IPM, FFN 25K5IPN and FFN 25K10IPM. The confirmation of manufacturer specification (969-517) is only available in conjunction with the DAkkS calibration certificate.WarrantyAccording to Kern & Sohn, these devices come with a 2-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer.DownloadsOperating instructions Kern FFN (PDF)Regulatory informationAs electrical devices, the balances fall under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Individual requirements and procurement serviceThe WTB-A01N rechargeable battery, the PFB-A02 to PFB-A05 and YKA-11 plug-in mains adaptors, and the RFS-A02 stainless steel fruit bowl are also available. For the FFN 1K-4N and FFN 1K-4NM, Kern also lists the Safety Set 315-411-407, which includes weights of 100 g and 1,000 g (M1). Enquiries are handled via our procurement service.
Kern compact laboratory balance PCB 1000-2, 1,200 g / 0.01 g, KUP interface
The Kern PCB 1000-2 is a compact laboratory balance from Kern’s IoT range, designed for a readability of 0.01 grams. According to Kern, the weighing range extends up to 1,200 g. It operates as a single-range balance with a strain gauge system, and the resolution is 120,000 divisions. Accuracy and weighing technology Reproducibility and readability are both 0.01 grams, whilst linearity is ± 0.03 grams. Once the sample is placed on the balance, the reading stabilises within 3 seconds. According to Kern, a minimum sample weight of 20 grams is sufficient to achieve a measurement uncertainty of 0.1 % at k=2. The maximum creep is 100 milligrams after 15 minutes and 200 milligrams after 30 minutes. External adjustment The PCB 1000-2 is adjusted externally at a selectable adjustment point (300 grams, 600 grams or 1.2 kilograms). Kern recommends adjustment weights of 200 grams (F2) and 1 kilogram (F2). KUP interface for Industry 4.0 As standard, the balance features a KUP (KERN Universal Port) connection. Using KUP adaptors, it can be expanded to include RS-232, USB device, Ethernet, Wi-Fi or Bluetooth BLE; with the KUP-13 expansion box, up to three adaptors can be used simultaneously. This allows the PCB 1000-2 to be connected to networks and data acquisition systems. Housing, weighing pan and display The housing measures 163 x 245 x 65 millimetres and is made of plastic; the weighing pan, with a side length of 130 x 130 millimetres, is made of stainless steel. The backlit LCD display shows digits 21 millimetres high. The scale has a net weight of 1.2 kilograms. The permissible ambient temperature ranges from -10 °C to 40 °C. Battery operation The scale is powered by the supplied universal mains adaptor. If required, the PCB 1000-2 can be powered by four AA batteries (1.5 volts); the batteries are not included in the scope of delivery. In battery mode, the scale has a battery life of up to 20 hours, whilst an auto-off function saves additional energy. Typical applications Kern lists the following applications for the PCB 1000-2: Laboratory applications Educational institutions Research and development Industrial applications Regulatory informationAs an electrical device, the balance falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Frequently asked questions about the PCB 1000-2 What is the weighing range? The weighing range extends up to 1,200 grams with a readability of 0.01 grams. Can the balance be connected to a PC or network? As standard via the KUP connection; with KUP adaptors, it can also be connected via RS-232, USB, Ethernet, Wi-Fi or Bluetooth BLE. Can the balance be operated without mains power? Yes, using four AA batteries, which are not included in the scope of delivery. The battery life is up to 20 hours. How is the balance adjusted? Externally, at a selectable adjustment point (300 grams, 600 grams or 1.2 kilograms). Kern recommends adjustment weights of 200 grams (F2) and 1 kilogram (F2). How long is the warranty? According to Kern & Sohn, this device comes with a 2-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer. Technical details Weighing range (max)1,200 gReadability (d)0.01 gReproducibility0.01 gLinearity± 0.03 gResolution120,000Minimum sample weight (k=2, U=0.1 %)20 gStabilisation time3 sWeighing systemStrain gauge, single-range balanceWeighing pan size130 x 130 mmWeighing pan materialStainless steelHousing materialPlasticHousing dimensions (W x D x H)163 x 245 x 65 mmAdjustmentexternal, at a selectable adjustment point (300 g, 600 g or 1.2 kg); recommended adjustment weights 200 g (F2) and 1 kg (F2)InterfacesKUP (standard), optional RS-232, USB device, Ethernet, Wi-Fi or Bluetooth BLE via KUP adapterOperating temperature-10 °C to 40 °CMaximum creep (15 min)100 mgMaximum creep (30 min)200 mgDisplaybacklit LCD, digit height 21 mmWeight (net)1.2 kgWeight (packed)2.0 kgWarranty (manufacturer)24 months according to Kern, excluding wear parts Scope of delivery PCB 1000-2 compact laboratory balance Universal mains adaptor Protective cover Hook for under-table weighing Batteries for portable use are not included in the scope of delivery. Individual requirements and procurement service For the PCB 1000-2, the following are available, amongst other items: a safety kit 315-411-406 with 50-gram and 1,000-gram weights (M1), a signal lamp, KUP interface adaptors for RS-232, USB, Ethernet, Wi-Fi and Bluetooth BLE, additional protective covers, a DAkkS calibration certificate (963-127), upon request together with a confirmation of the manufacturer’s specification (969-517), and a 3-year warranty extension (970-014). Enquiries about these and other accessory requests relating to Kern laboratory balances are handled through our procurement service.
Kern DAB 100-3IR infrared moisture analyser, 110 g / 0.001 g (0.01 %)
The Kern DAB 100-3IR is a moisture analyser with an infrared heating element (400 W) and a weighing range of 110 g. It reads to 0.001 g or 0.01 % moisture. The measuring principle is thermogravimetric: the internal balance records the weight of the sample during drying, and the instrument calculates the moisture content from the weight loss.Infrared or halogenThe drying temperature can be set from 40 to 160 °C in 1 °C steps. The Kern DAB 100-3 (item no. lt-21715) with a halogen heating element, which reaches 199 °C, is also available. The weighing range and readability are the same; the difference lies in the heating technology and the temperature range. Anyone who wants to dry samples above 160 °C should choose the halogen version. For samples that tolerate moderate temperatures, the infrared version is sufficient.Drying programmes and switch-offThe heating profiles standard drying, fast drying and gentle drying are available. The typical stabilisation time is 3 seconds. The instrument switches off automatically when the weight remains constant (according to the operating instructions, at a weight loss of 2 mg in 45 seconds), by timer after 3 to 99 minutes, or manually with the stop key.Display, memory and interfaceThe backlit graphical display has digits 14 mm high and shows moisture content, dry content and residual weight. The instrument can store 15 drying methods and 5 measurement results. Via the RS-232 interface, it sends measurement reports to a printer or PC.Weighing technology and accuracyReproducibility 0.001 g, linearity ± 0.003 g. According to Kern, the reproducibility of the moisture reading is 0.15 % (sample weight 2 g) or 0.03 % (sample weight 10 g), depending on the application. The minimum weight according to USP is 2 g, and the sample size is 1 g to 110 g. The drying chamber measures 92 mm in diameter and is 20 mm high. Before the first measurement, the instrument needs a warm-up time of 2 hours. Adjustment is external; Kern recommends a weight of 100 g (F2), which is not included in the scope of delivery.Typical applicationsKern lists the following fields of application for the DAB series:Food production and the food industryWater managementEnergy and raw materials industryAgricultureTypical tasks include incoming goods inspection of raw materials and moisture determination during ongoing production.Frequently asked questionsUp to what temperature does the DAB 100-3IR dry?Up to 160 °C, adjustable in 1 °C steps from 40 °C. The halogen version DAB 100-3 reaches 199 °C.How small can the sample be?For a measurement uncertainty of 0.1 % at k=2, Kern specifies a minimum weight according to USP of 2 g.How long does the instrument need to warm up?The warm-up time is 2 hours.Can the instrument be connected to a printer or PC?Yes, via the serial RS-232 interface.How long is the warranty?According to Kern & Sohn, this device comes with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer.Technical detailsWeighing range (max)110 gReadability (weight)0.001 gReadability (moisture)0.01 %Reproducibility0.001 gLinearity± 0.003 gReproducibility of moisture reading (sample weight 2 g / 10 g)0.15 % / 0.03 %Minimum weight (USP)2 gSample size1 g to 110 gHeating methodInfrared heating element, 400 WTemperature range40 °C to 160 °C, in 1 °C incrementsStabilisation time3 sWarm-up time2 hDrying programmesStandard drying, fast drying, gentle dryingSwitch-off criteriaautomatic, time-controlled (3 to 99 min), manualMethod memory15 drying methodsResult memory5 measurementsDisplayGraphical display, backlit, digit height 14 mmDrying chamberØ 92 mm, 20 mm highInterfaceRS-232Power supply230 V AC, 50 HzDimensions (W x D x H)240 x 365 x 180 mmWeight (net)5.0 kgOperating temperature5 °C to 40 °COperating humidity5 % to 80 %, non-condensingScope of deliveryDAB 100-3IR moisture analyser50 sample dishes (aluminium)Power cableOperating instructionsRegulatory informationAs an electrical device, the device falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Individual requirements and procurement serviceSpare sample dishes, glass fibre filter circles, an adjustment weight, a DAkkS calibration certificate (item no. 963-127) and ISO temperature calibration (item no. 964-305) are available for the DAB 100-3IR. We can advise you on the selection. Enquiries are handled through our procurement service.
IKA ROTAVISC hi-vi II Complete Rotational Viscometer Set, for high-viscosity media and pastes, 0010013829
Pastes, adhesives, resins or greases are often difficult to measure reliably using a standard viscometer, as their flow behaviour lies well outside the measuring range for low-viscosity media. The ROTAVISC hi-vi II Complete from IKA is fitted with the stiffest measuring spring in the ROTAVISC range and, as a complete set comprising a stand, spindles and a temperature probe, covers a range from 800 to 320,000,000 mPas.Rigid measuring spring for highly viscous media and pastesWith a spring torque of 5.7496 mNm, the hi-vi-II measuring system operates with significantly greater stiffness than the lo-vi and me-vi variants of the series and is therefore specifically designed for viscous to paste-like samples. The viscosity measurement range extends from 800 to 320,000,000 mPas with an accuracy of 1 % of full scale (FSR) and a repeatability of 0.2 % FSR. The supplied spindle set SP set-2 (SP 7 to SP 12) is designed for the higher viscosity range and delivers a stable, analysable torque signal even with viscous substances.TFT display, torque measurement and timerSpeed, torque and temperature are displayed on the TFT touchscreen as setpoint and actual values; the integrated graphing function records the viscosity curve directly on the instrument. This is particularly useful with highly viscous media, as it enables the early detection of structural viscosity or sample hardening during the measurement. The speed range extends from 0.01 to 200 rpm with a setting accuracy of ±0.01 rpm; the timer covers 0.017 to 6,000 minutes in timer or continuous operation. A calibration function is integrated directly into the device. The integrated overload protection reacts if a very viscous or already set sample subjects the motor to a load exceeding the permissible torque, thereby protecting against damage to the measuring head during prolonged, unattended measurement runs.Temperature-controlled measurement with PT 100Many highly viscous media, such as melts, resins or temperature-dependent pastes, exhibit significant changes in viscosity even with small temperature fluctuations. The PT 100.8 sensor included in the scope of delivery has a resolution of 0.1 Kelvin and, together with the instrument, covers a working temperature range from minus 100 to 300 °C. For actively temperature-controlled measurement series, an external cooling/heating circulating thermostat such as the HRC 2 lite or the CBC VISC lite can be connected; for documenting the measurement series, an RS-232 interface and a micro-USB port are available for the Labworldsoft 6 laboratory instrument software.Typical applicationsWith its rigid measuring spring and extended measurement range, the ROTAVISC hi-vi II Complete is technically suitable for:Quality control of adhesives, sealants and resinsTesting of greases, pastes and high-viscosity emulsionsFormulation development for viscous formulations in research and developmentIncoming inspection of high-viscosity raw materials with defined specificationsIn-process monitoring in plastics and adhesives processingBrief differentiation within the ROTAVISC rangeIn addition to the hi-vi-II model described here, IKA offers the ROTAVISC series in further measurement range variants. The ROTAVISC lo-vi Complete measures from 1 to 6,000,000 mPas using a softer spring and is suitable for low-viscosity to medium-viscosity media. The ROTAVISC me-vi HELI Complete covers a medium range from 100 to 40,000,000 mPas and also includes a motorised Helistand stand for samples that do not flow freely during measurement. As a rough guide: users who regularly switch between low-viscosity and paste-like batches when changing samples are often better served by the hi-vi-II set described here, together with an additional lo-vi spindle set from the range of accessories, than by using two separate instruments.Distinction from the SBS series with a more robust ball bearing systemFor applications involving particularly frequent spindle changes or continuous operation under high mechanical stress, IKA also offers the hi-vi series in an SBS version with a more robust ball bearing system: the ROTAVISC SBS hi-vi II Complete. For the vast majority of routine laboratory measurements, the standard bearing arrangement of the Complete set described here is sufficient; the SBS variant is particularly worthwhile for very intensive, multi-shift use.Technical detailsViscosity measurement range800 to 320,000,000 mPasAccuracy (FSR)1 %Repeatability (FSR)0.2 %Spring torque5.7496 mNmMeasuring spindlesSP set-2 (SP 7 to SP 12)Motor power, output4.8 WMotor direction of rotationclockwise, with overload protectionDisplayTFT touchscreen with graph functionSpeed range0.01 to 200 rpm, setting accuracy ±0.01 rpmTorque display / measurementYesTimer0.017 to 6,000 min, timer and continuous operationWorking temperature-100 to 300 °C, temperature measurement resolution 0.1 KConnection for external temperature sensorPT 100Base vessel volume600 mlStandRotastand, max. stroke 200 mm, Ø 16 mm, dynamic load 5 kgStroke of telescopic stand200 mmInterfacesRS 232, USB (Micro-USB)Degree of protectionIP 40 in accordance with DIN EN 60529Dimensions (W x H x D)351 x 629 x 372 mmWeight7.1 kgConnected load100 to 240 V, 50/60 Hz, 24 WScope of delivery1 x ROTAVISC hi-vi II control S000 (measuring head)1 x Rotastand (stand)1 x SP set-2 (standard spindle set SP 7 to SP 12)1 x PT 100.8 (temperature sensor)1 x Guard rail (protective bracket)Use, installation, maintenance and disposalThe instrument is protected against solid foreign objects from 1 millimetre in size in accordance with degree of protection IP 40. In the case of viscous, sticky or hardening media, it is recommended that the spindle and measuring vessel be cleaned immediately after each measurement, before residues dry out and make cleaning more difficult or distort the next measurement. The stand should be placed on a stable, level surface so that the high rigidity of the measuring spring is not compromised by vibrations. It is advisable to switch off the power to the device before changing the spindle or vessel. At the end of its service life, the ROTAVISC hi-vi II Complete, as an electrical appliance, must not be disposed of with household waste but must be placed in the separate collection scheme for end-of-life electrical equipment. As highly viscous media are often difficult to remove from the base vessel, it is advisable, in the case of very sticky samples, to clean the equipment promptly after cooling, whilst residues can still be dissolved using standard commercial solvents.WarrantyManufacturer’s warranty from IKA: 2 years, extended to 10 years upon registration at ika.com/register within 90 days of purchase.Regulatory informationThis device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer, IKA, is DE 66784213. Information on the return of old appliances can be found on our page Environment and disposal.Individual requirements & procurement serviceAdditional spindles and adapters for other viscosity ranges, measuring chambers, standard silicone oils for calibration, external circulating thermostats and the Labworldsoft 6 laboratory equipment software are available for the ROTAVISC hi-vi II Complete as required, as is factory calibration. An additional spindle set for the low-viscosity range (SP set-1) can also be retrofitted if, in addition to viscous media, you occasionally need to analyse more fluid samples. Through our procurement service, we will assist you in selecting from our range of viscometers.Frequently Asked QuestionsWhat viscosity range is the hi-vi-II model designed for?For 800 to 320,000,000 mPas, using the stiffest measuring spring in the ROTAVISC range for highly viscous media and pastes.Is the instrument ready for immediate use?Yes, the measuring head, Rotastand, SP set-2 spindle set, PT 100.8 temperature sensor and protective bracket are all included in the scope of delivery.What distinguishes the hi-vi-II model from the lo-vi model?The lo-vi Complete measures from 1 to 6,000,000 mPas using a softer spring and is suitable for low-viscosity to medium-viscosity media.Is there a version with a more robust bearing system?Yes, the SBS variant, the ROTAVISC SBS hi-vi II Complete, features a more robust ball bearing system for very intensive use.Can the sample be temperature-controlled during the measurement?Using the supplied PT-100 probe and an optional external circulating thermostat, such as the CBC VISC lite or HRC 2 lite.Can I also measure lower-viscosity samples with the same instrument?With an additional SP-set-1 spindle set (available separately), the measurement range can be extended to cover lower viscosities; for very low-viscosity media, the ROTAVISC lo-vi Complete remains the more accurate choice.
Sauter HB analogue Shore hardness testers, Shore A, Shore A0 and Shore D, measuring range 100, drag pointer
With the analogue Shore hardness testers of the Sauter HB, you test the hardness of rubber, elastomers and plastics by indentation measurement, without power and without a battery. The series comprises three models in metal housings: the HBA 100-0 measures on the Shore A scale, the HB0 100-0 on the Shore A0 scale and the HBD 100-0 on the Shore D scale. All instruments have a measuring range of 100 with a readability of 1 and display the measured value on an analogue scale.Drag pointer and max modeAll instruments have a drag pointer. It holds the peak value reached by the measuring tip when pressed in, and the value stays on the scale after lifting off. Kern calls this max mode. A device without a display or electronics has no interface and no memory; the reading is taken directly from the scale.Shore A, Shore A0 or Shore DThe scale determines which materials a device is intended for. Kern intends the HBA 100-0 with Shore A for rubber, elastomers, neoprene, silicone, vinyl, soft plastics, felt and leather. The HB0 100-0 with Shore A0 is intended for soft materials such as foam and sponges. The HBD 100-0 measures on the Shore D scale, which is used for harder plastics. The scale applicable to a test object is usually specified by the material specification or internal test procedure. Anyone testing several material classes will need several instruments. The instruments differ in the scale and in the weight: the HBA 100-0 weighs approx. 0.15 kg, the other two approx. 0.20 kg. The housing, dimensions, measurement accuracy and minimum thickness of the test object are the same.Comparison measurements and test standKern recommends the HB series primarily for internal comparison measurements. According to Kern, calibrations according to standard are not possible because of very tight standard tolerances. The measurement accuracy is 3 % of the final value; the test object must be at least 6 mm thick. Without the test stand, the device is held against the sample by hand. All three devices can be screwed onto a Shore test stand using an M7 fine-pitch thread. The HBA 100-0 and the HB0 100-0 fit onto the TI-AC test stand, whilst the HBD 100-0 fits onto the TI-D. The test stand holds the device in a suspended position and presses the measuring tip into the test object using a fixed test weight. According to Kern, the accuracy of the measurement result on the test stand is around 25 % higher than with a manual measurement.Typical applicationsPlastics engineering: comparing the hardness of plastic components and elastomersMedical technology: hardness testing of elastomer componentsAutomotive industry: hardness testing of seals and rubber componentsPackaging industry: testing the hardness of film and foam materialsFood industry: hardness testing of seals and plastic componentsThe HBA 100-0 is suitable for rubber and soft plastics, the HB0 100-0 for foam and sponges, whilst the HBD 100-0 is suitable for harder plastics. Measurements taken with the same instrument can be compared across batches and deliveries, for example during goods receipt or in production control. For measurements with a display, memory or data transmission, the Sauter HD and HE digital hardness testers are available; these series are also available.Models at a glanceModelHardness scaleMeasuring rangeReadabilitySuitable test standWeightHBA 100-0Shore A100 HA1 HATI-ACapprox. 0.15 kgHB0 100-0Shore A0100 HA01 HA0TI-ACapprox. 0.20 kgHBD 100-0Shore D100 HD1 HDTI-Dapprox. 0.20 kgTechnical detailsThese values apply to all models. Deviating values are given in the model table.Displayanalogue, drag pointer (max mode)Measurement accuracy3 % of the final valueTest object minimum thickness6 mmHousingMetal, 115 x 60 x 25 mm (W x D x H)Mounting on the test standM7 fine threadAmbient temperature0 °C to 40 °CStorage temperature-10 °C to 40 °CNet weightapprox. 0.15 kg (HBA 100-0), approx. 0.20 kg (HB0 100-0, HBD 100-0)Warranty (manufacturer)24 months according to Kern, excluding wear partsScope of deliverySauter HB Shore hardness tester (HBA 100-0, HB0 100-0 or HBD 100-0, depending on the model)Plastic boxWarrantyAccording to Kern & Sohn, these devices come with a 2-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer.DownloadsOperating instructions HB0 100-0 (PDF)Operating instructions HBD 100-0 (PDF)Individual requirements and procurement serviceThe TI-AC (Shore A, 10 N) and TI-D (Shore D, 50 N) Shore test stands, the AHBD-01 hardness reference plates for Shore D, and the HD and HE series digital Shore hardness testers are also available. Enquiries are handled via our procurement service.
WTW ProfiLine pH 3310 handheld meter (pH/mV, DIN connector), 2AA310
The WTW ProfiLine pH 3310 is the professional standard handheld meter for all users who demand high standards of reliability, data security and robustness, whether in the field, in the laboratory or in process monitoring. It combines precise digital analysis with a connection for tried-and-tested analogue pH electrodes (DIN). Robust field-ready design (IP 67) The instrument is fully waterproof and dustproof to IP 67. For specialist buyers working in the field (environmental measurement technology, aquaculture) or in harsh production environments, the instrument is protected even in the rain or if dropped into water. The backlit graphic display is clearly legible even in poor lighting conditions. Measurement reliability thanks to the CMC function A key advantage of the 3310 series is ‘Continuous Measurement Control’ (CMC). The device continuously displays a graphical indication to the user showing whether the current measurement is still within the range of the last calibration. This provides immediate assurance of the reliability of the measured value and prevents measurement errors caused by out-of-date calibrations. Data logger for GLP/AQS documentation The pH 3310 is suitable for quality assurance (AQS). It features a large data logger capable of storing up to 5,000 automatic (time-controlled) or 200 manual (at the touch of a button) data records. All data can be transferred to a PC via the integrated mini-USB interface including timestamps and sensor ID, which supports documentation in a GLP environment. Flexible electrode connection (DIN) This meter is deliberately equipped with a standard DIN connector (for pH/mV) and 4 mm banana sockets (for separate temperature sensors). This allows specialist buyers to continue using existing standard analogue electrodes from various manufacturers flexibly. Technical details Measurement channels: 1 (pH/mV) pH range: -2.000 to +19.999 pH mV range: ±1,200.0 mV; ±2,500 mV Temperature range: -5.0 to +105.0 °C Connection (pH): DIN (for pH electrodes) Connection (temperature): 2 × 4 mm banana sockets (for TFK probes or similar) Data storage: 200 (manual), 5,000 (automatic) Interface: Mini-USB-B (waterproof) Degree of protection: IP 67 Display: LCD (backlit, graphical) Calibration (pH): 1-, 2-, 3-, 4-, 5-point (WTW TEC / DIN buffers) Functions: CMC (Continuous Measurement Control) Power supply: 4 x 1.5 V AA (batteries) or USB operation Scope of delivery ProfiLine pH 3310 meter (main unit) 4 x AA batteries Quick start guide CD-ROM (with USB drivers and software) USB cable (A to Mini-B) Important note: The case, pH electrodes and temperature probe (TFK) are accessories and are not included with the basic unit (2AA310). Individual requirements & procurement service Do you need advice on the right pH electrode for your application (e.g. a robust SenTix 41 with a DIN plug) or a separate temperature probe (TFK 325)? Our team of experts will be happy to put together a complete set for you. For accessories not listed here, please use our bespoke procurement service.
KERN PNJ 3000-2M Precision Balance, tuning fork measurement system, internal calibration, suitable for verification (ex works only)
The Kern PNJ 3000-2M weighs up to 3,200 g and has a readability of 0.01 g. According to Kern, the tuning fork weighing system displays the value after approximately 3 seconds, whilst the internal adjustment runs automatically. The balance is suitable for weighing applications in pharmacies, laboratories and quality control, and can be ordered with verification.Tuning-fork weighing systemIn this weighing principle, a resonant body is set into oscillation electromagnetically in response to the load. Kern describes the system as robust and fast in its display. The stabilisation time is 3 s, the resolution is 320,000 steps, the reproducibility is 0.01 g and the linearity is ± 0.03 g. The USP minimum sample weight is 20 g (k = 2, U = 0.1 %).Internal adjustmentThe balance adjusts itself automatically using a built-in weight. External test weights are not required for routine use. After switching on, the instrument requires a warm-up time of 120 minutes; the permissible ambient temperature is 5 °C to 40 °C with a maximum relative humidity of 80 %.Verification as an optionFor the PNJ 3000-2M, conformity assessment according to NAWI 2014/31/EU is available ex works. The verification scale interval is 0.1 g, the minimum load is 0.5 g, and the accuracy class is II. Kern points out that verification must be ordered at the same time as the balance; subsequent conformity assessment is not possible. For verification, Kern requires the full address of the installation site. On a verified balance, the units g and ct are available; without verification, the additional units dwt, tl (Tw), tl (HK), ozt, tl (Singapore, Malaysia), mo, lb, oz and tol are also available.Kern cites pharmacies as one of the areas of application. Where the weighing result is subject to mandatory verification, verification should therefore be part of the order.Everyday functionsTo count small parts, select a reference count of 10, 30, 50 or 100; automatic reference optimisation gradually improves the average part weight. The minimum part weight is 10 mg under laboratory conditions and 100 mg under standard conditions. The percentage calculation displays the deviation from the target value. During checkweighing, the balance visually indicates whether the weight is within tolerance. A bar displays the remaining available weighing range. The backlit LCD has digits 16.5 mm high; operation is via five buttons, and the preset unit is g. For carats, there is a dedicated range up to 16,000 ct with a readability of 0.1 ct.The stainless steel weighing pan measures 190 x 190 mm and is shock-resistant. The plastic housing is 89 mm high; with a base area of 196 x 293 mm, it is compact enough for a workspace with limited room. A spirit level and adjustable feet are included. Data is transmitted to a PC or printer via the RS-232 interface. The balance generates a printout at the printer showing the value, date and time, which Kern describes as GLP-compliant.Position within the PNJ rangeThe range includes two further models. The PNJ 600-3M weighs up to 620 g and has a readability of 0.001 g; its verification scale interval is 0.01 g and the minimum load is 0.02 g; the weighing surface has a diameter of 140 mm. The PNJ 12000-1M weighs up to 12,000 g, has a readability of 0.1 g, a verification scale interval of 1 g and a minimum load of 5 g, with the same weighing surface measuring 190 x 190 mm. The PNJ 3000-2M falls between these two. If you mainly weigh quantities ranging from a few grams to a few kilograms, this model is suitable. Anyone who needs to read to thousandths of a gram below 1 g needs the 600-3M; anyone weighing containers up to 12 kg needs the 12000-1M.Typical applicationsFormulation and weighing in pharmacies, with verificationQuality control and incoming goods inspection in the electronics and precision engineering industriesWeighing and preparation in laboratory settingsDental laboratoriesCounting small parts, such as screws, seals or contactsTechnical detailsWeighing range (max)3,200 g (16,000 ct)Readability (d)0.01 g (0.1 ct)Verification scale interval (e)0.1 gMinimum load (Min)0.5 gReproducibility0.01 gLinearity± 0.03 gStabilisation time3 sWeighing systemTuning forkTypeSingle-range balanceAdjustmentInternal, automaticWeighing pan190 x 190 mm, stainless steelHousing (W x D x H)196 x 293 x 89 mm, plasticDisplayBacklit LCD, digit height 16.5 mmInterfaceRS-232 as standardPower supplyMains adaptor, 220 V to 240 V AC, 50 HzAmbient temperature5 °C to 40 °CRelative humiditymaximum 80 %Warm-up time120 minutesNet weightapprox. 3.6 kgScope of deliveryKern PNJ 3000-2M precision balance with stainless steel weighing panMains adaptor with plug adaptors for the EU, UK, US, AUS and CHProtective working coverVerification is not included as standard and must be ordered separately if required.According to Kern & Sohn, this device comes with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer.Regulatory informationAs an electrical device, the balance falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Individual requirements and procurement serviceRS-232 cables, printers, anti-vibration plates and a DAkkS calibration certificate are also available, as is the SCD-4.0 software for data transfer to a PC. Enquiries are handled via our procurement service.
WTW ProfiLine pH 3310 Set 2 pocket pH meter (logger & USB), 2AA312
The WTW ProfiLine pH 3310 Set 2 is a professional, portable pH measurement system designed for precise measurements in the field and data documentation in the GLP/AQS environment. The 3310 has an integrated data logger capable of storing up to 5,000 entries and a waterproof mini-USB interface. This enables the automated recording of measurement series (e.g. long-term monitoring of water bodies) and rapid transfer to a PC without the need for proprietary adapters. Measurement technology and process reliability The device offers 5-point calibration and the tried-and-tested CMC (Continuous Measurement Control) function. This displays on the backlit graphic display whether the current measured value is still within the calibrated range and issues a warning in the event of deviations. This increases the reliability of the measured values, particularly with changing sample matrices. Electrode and robustness ‘Set 2’ includes the low-maintenance SenTix® 41 pH electrode. It features a robust plastic shaft, an integrated temperature sensor (NTC 30 kOhm) for automatic temperature compensation, and a gel electrolyte that eliminates the need for refilling. The meter itself is waterproof to IP 67 (including the USB socket!) and can withstand brief submersion, making it suitable for harsh environments or sewage treatment works. Technical details pH measurement range: -2.000 … +19.999 pH Accuracy (pH): ±0.005 pH mV measurement range: ±1,200.0 / ±2,500 mV Temperature measurement range: -5.0 … +105.0 °C Calibration: 1- to 5-point (22 buffer sets stored) Data memory: 5,000 entries (automatic) / 200 (manual) Interface: Mini-USB-B (waterproof) Degree of protection: IP 67 Power supply: 4 x 1.5 V AA (up to 100 hours of continuous operation) or via USB Scope of delivery ProfiLine pH 3310 meter SenTix® 41 pH electrode (gel, integrated temperature sensor) STP 4 buffer solution (50 ml) STP 7 buffer solution (50 ml) Measuring beaker Stand Professional carrying case USB cable (A to Mini-B) CD-ROM with driver software Batteries (4x AA) Quick start guide Individual requirements and procurement service Do you require more precise glass electrodes (e.g. SenTix 81) for laboratory applications, or a kit for drinking water analysis or industrial requirements? We will gladly advise you on request.
Kern PNJ 600-3M precision balance, 620 g / 0.001 g, internal adjustment
The Kern PNJ 600-3M weighs up to 620 g and has a readability of 0.001 g. The weighing system is a tuning-fork system; the balance adjusts itself automatically and internally. According to Kern, the balance is suitable for applications subject to legal metrology requirements if the conformity assessment (option 965-216) is ordered at the same time.Tuning-fork weighing systemKern employs a tuning-fork weighing system here, which displays the weight reading quickly, allows for precise dosing and is mechanically robust. Reproducibility and readability are both 0.001 g, whilst linearity is ± 0.004 g. Under laboratory conditions, the stabilisation time is 3 seconds and the warm-up time is 4 hours. The minimum load is 0.02 g, whilst the minimum weight according to USP is 2 g. A rising bar graph display shows the remaining available weighing range.Internal automatic adjustmentThe balance adjusts automatically using an internal weight. According to Kern, this maintains high accuracy and makes it location-independent. For checking purposes, the Safety Set 315-109-206 is available, comprising 50 g (F1) and 500 g (E2). A DAkkS calibration is available under item no. 963-103. We can advise you on verification and the validity of verification upon request.Glass draught shield and weighing panThe stainless steel weighing pan has a diameter of 140 mm and is shock-resistant. The large glass draught shield with three sliding doors has a weighing chamber measuring 172 x 171 x 160 mm. With the glass draught shield fitted, the balance measures 196 x 293 x 266 mm and weighs 4.2 kg net. Kern highlights the compact dimensions as an advantage in confined spaces. A spirit level and adjustable screw feet are included. The display features 16.5 mm high backlit digits and has no IP rating.Counting, carats, data outputAutomatic reference optimisation during piece counting gradually refines the average value of the piece weight. The minimum piece weight is 10 mg, or 1 mg under laboratory conditions, with a counting resolution of 620,000. In carats, the balance displays up to 3,100 ct with a readout of 0.01 ct. RS-232 is fitted as standard. Kern offers the MLB-A05 interface cable (1.5 m), the YKI-02 Bluetooth adapter, converters for Ethernet and Wi-Fi (YKI-10, YKI-11, YKI-12) and the YKG-01, YKH-01, YKC-01 and YKT-01 printers. The power supply operates at 220 to 240 V and 50 Hz and is supplied with adaptors for Australia, Switzerland, the EU, the UK and the USA.Typical applicationsBased on the technical specifications and manufacturer’s information, the following applications are possible:Weighing in the milligram range up to 620 gDosing with rapid display via the tuning fork systemApplications subject to legal metrology requirements, provided that the verification (option 965-216) is ordered at the same timePiece counting from a unit weight of 10 mgWeighing of gemstones in carats up to 3,100 ctFor comparison, from the Kern range: with a readability of 0.0001 g at 220 g, the Kern ADB 200-4 offers finer weighing; the Kern ABT 100-5NM offers a readability of 0.00001 g at 101 g. For 2,000 g at 0.1 g, there is the Kern PCB 2000-1.Frequently asked questionsHow is the PNJ 600-3M adjusted?Internally and automatically using a built-in weight.Is the balance suitable for applications subject to legal metrology requirements?The PNJ 600-3M is optionally available ex-works with conformity assessment (verification) (option 965-216, accuracy class II, verification scale interval e = 0.01 g). For applications subject to legal metrology requirements, the option must be ordered at the same time; subsequent initial verification is not possible.How big is the weighing pan?140 mm in diameter, made of stainless steel.How long does the balance need to warm up?The warm-up time is 4 hours.How long is the warranty?According to Kern & Sohn, this device comes with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer.Technical detailsWeighing range (max)620 gReadability (d)0.001 gReproducibility0.001 gLinearity± 0.004 gMinimum load (Min)0.02 gMinimum weight (USP)2 gTare range620 gStabilisation time (laboratory conditions)3 sWarm-up time4 hWeighing systemTuning forkCarat3,100 ct, resolution 0.01 ctCount resolution620,000Minimum unit weight10 mg, 1 mg under laboratory conditionsWeighing panØ 140 mm, stainless steelDraught shieldGlass, three sliding doors, weighing chamber 172 x 171 x 160 mmDisplayDigit height 16.5 mm, backlightingAdjustmentInternal, automaticInterfaceRS-232 as standardInput voltage220 V to 240 V AC, 50 Hz, power supply unitAmbient temperature5 °C to 40 °CHumiditymax. 80 %Dimensions with draught shield (W x D x H)196 x 293 x 266 mm, plasticWeight (net)4.2 kgScope of deliveryPNJ 600-3M precision balance with glass draught shieldMains power supply with mains adaptors for Australia, Switzerland, the EU, the UK and the USAProtective working coverRegulatory informationAs an electrical device, the balance falls under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Individual requirements and procurement serviceKern offers protective working covers (PNJ-A01, also available in packs of 5), test weights, interface cables, converters, printers, as well as anti-vibration tables and anti-vibration plates for the PNJ 600-3M. We can advise you on your selection. Enquiries are handled through our procurement service.
Sauter TN ultrasonic material thickness gauges, pulse-echo and echo-echo, up to 300 mm
The Sauter TN series comprises handheld ultrasonic measuring devices for measuring the thickness of a workpiece from just one side. An external probe transmits ultrasound into the material; the device calculates the wall thickness based on the transit time. The series comprises seven models: five pulse-echo devices for metals and plastics (TN 80-0.01US, TN 80-0.1US, TN 230-0.01US, TN 230-0.1US, TN 300-0.01US) and two devices with an additional echo-echo mode for coated parts (TN 30-0.01EE, TN 60-0.01EE). All are battery-operated and, at 150 x 74 x 32 mm, fit in one hand.Pulse-echo or echo-echoIn pulse-echo mode, the device measures the total thickness, including any coating. According to Kern, the echo-echo models TN 30-0.01EE and TN 60-0.01EE determine the actual material thickness independently of any existing coating. This allows, for example, the wall thickness of pipes to be measured non-destructively without removing the coating. The device can display the measured value already corrected for coating thickness. Echo-echo measurements only work with the supplied ATU-US12 probe. The echo-echo range is from 3 to 30 mm for the TN 30-0.01EE and from 3 to 60 mm for the TN 60-0.01EE. In pulse-echo mode, both measure from 0.65 to 600 mm.Probe, frequency and rangeRange and probe belong together. The probe of the TN 300-0.01US operates at 2.5 MHz, has a diameter of 14 mm and measures from 3 to 300 mm. Both TN 230 models have a 5 MHz probe with a diameter of 10 mm and measure from 1.2 to 230 mm. The two TN 80 models have a 7 MHz probe with a diameter of 6 mm and measure from 0.75 to 80 mm. The two TN 80 models and the two TN 230 models each differ in readability (0.01 mm versus 0.1 mm) and in the interface: the models ending in 0.1US (TN 80-0.1US, TN 230-0.1US) do not have a USB port. The sound velocity ranges from 1,000 to 9,999 m/s; Kern specifies the measurement accuracy as 0.5 % of Max ± 0.04 mm.Measuring modes, memory and data transferAll models can measure either in scan mode at 10 measurements per second or at a single measurement point. On all models, the internal memory can store up to 20 files, each containing up to 100 individual values. The unit is mm or inches. With the exception of the TN 80-0.1US and the TN 230-0.1US, all models have a USB interface. The LCD display features 14 mm high digits. According to the data sheet, two AA batteries last for approximately 100 h.Typical applicationsMetalworking and mechanical engineering: wall thickness of sheet metal, tubes and castingsOil and gas industry: wall thickness inspection on pipework, including under coatings (echo-echo)Aerospace: thickness measurement on components from one sidePlastics engineering: wall thickness of plastic componentsShipbuilding industry: plate thickness and corrosion checking on hullsFor thin walls from 0.75 to 80 mm, one of the two TN 80 models is sufficient; for measuring ranges up to 230 mm with a readability of 0.01 mm, the TN 230-0.01US is sufficient. For measuring thicker workpieces up to 300 mm, use the TN 300-0.01US; for inspecting coated tubes, use one of the two EE models.Models at a glanceModelMethodsPulse-echo measuring rangeEcho-echo measuring rangeReadabilityProbeUSBWeightTN 80-0.01USPulse-echo0.75 mm to 80 mmnot provided0.01 mm7 MHz, Ø 6 mmUSB0.30 kgTN 80-0.1USPulse-echo0.75 mm to 80 mmnot provided0.1 mm7 MHz, Ø 6 mmnone0.25 kgTN 230-0.01USPulse-echo1.2 mm to 230 mmnot provided0.01 mm5 MHz, Ø 10 mmUSB0.25 kgTN 230-0.1USPulse-echo1.2 mm to 230 mmnot provided0.1 mm5 MHz, Ø 10 mmnone0.30 kgTN 300-0.01USPulse-echo3 mm to 300 mmnot provided0.01 mm2.5 MHz, Ø 14 mmUSB0.30 kgTN 30-0.01EEPulse-echo and echo-echo0.65 mm to 600 mm3 mm to 30 mm0.01 mm5 MHz, Ø 10 mmUSB0.25 kgTN 60-0.01EEPulse-echo and echo-echo0.65 mm to 600 mm3 mm to 60 mm0.01 mm5 MHz, Ø 10 mmUSB0.30 kgTechnical detailsThese values apply to all models. Deviating values are given in the model table.Measurement principleUltrasound, external probe, 0.9 m cableSound velocity1,000 m/s to 9,999 m/sMeasurement accuracy (Kern)0.5 % of Max ± 0.04 mmMeasuring modesScan mode (10 measurements per second) or single measurement pointMemory20 files, each containing up to 100 individual valuesUnitsmm, inchDisplayLCD, digit height 14 mmPower supply2 AA batteries (1.5 V), alkaline-manganese, operating time approx. 100 hHousingPlastic, 150 x 74 x 32 mm (W x D x H)Ambient temperature-10 °C to 40 °CFactory calibration certificatecan be ordered separately, item no. 961-113Warranty (manufacturer)36 months according to Kern, excluding wear partsScope of deliverySauter TN material thickness gauge (TN 80-0.01US, TN 80-0.1US, TN 230-0.01US, TN 230-0.1US, TN 300-0.01US, TN 30-0.01EE or TN 60-0.01EE) with external probe, ultrasonic coupling gel, batteries, operating instructions and carrying caseCalibrationA factory calibration certificate (item no. 961-113) can be ordered separately.WarrantyAccording to Kern & Sohn, these devices come with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer.DownloadsOperating instructions TN 30-0.01EE, TN 60-0.01EE (PDF)Operating instructions TN 230-0.01US to TN 300-0.01US (PDF)Regulatory informationAs electrical devices, the material thickness gauges fall under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.Individual requirements and procurement serviceAdditional probes (ATB-US02, ATB-US06, ATU-US01, ATU-US02, ATU-US09, ATU-US10 and, for the echo-echo models, ATU-US12), the coupling gel ATB-US03, the USB cable FL-A01 and the ATU-04 software are also available. Please enquire to find out which probes are compatible with which model. Enquiries are handled via our procurement service.