Liquid Handling
Liquid Handling covers precise pipetting and dispensing in the laboratory. LT Laborhandel offers electronic and mechanical pipettes from Eppendorf (Xplorer series, Multipette) and BRAND (Transferpette, Dispensette bottle-top dispensers) as well as from IKA: the new electronic single-channel pipette IKA PEN with display, five pipetting modes, Bluetooth and a lithium battery for a full working day according to the manufacturer, plus multichannel pipettes from the PETTE series. From single-channel pipettes to bottle-top dispensers, you will find the right instrument for your application. Our service team will be happy to help.
NewPromo
PEN
The new electronic pipette
From 0.5 to 200 µl, with display, five pipetting modes and app.
Compared with the IKA RRP. Until 31 December 2026.

Eppendorf Research plus single-channel pipette, variable, 100–1,000 µL, blue, 3123000063
The Eppendorf Research plus for 100 to 1,000 µL is a mechanical single-channel pipette with adjustable volume. The volume is selected in steps of 1 µL and read on the four-digit volume display. The colour code blue belongs to the matching tip, namely epT.I.P.S. 50 to 1,000 µL.Setting the volumeVolume selection, pipetting and tip ejection are handled by separate controls. The pipette works with an air cushion. The smallest adjustable step is 1 µL. Anyone who pipettes preparations in many different volumes manages with an adjustable-volume pipette and does not need a set of fixed-volume pipettes.Tips and colour codeAccording to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. Here, this is the colour code blue for epT.I.P.S. 50 to 1,000 µL. The colour code depends on the tip and not on the pipette volume. The pipette is an open system, and tips from other manufacturers are possible. However, the measurement deviations apply only with original epT.I.P.S.AdjustingThe pipette can be adjusted temporarily. 5 adjustment seals and an adjustment tool (hex key) are supplied for this purpose. Returning to the factory adjustment is possible without calibration.Typical applicationsTransferring reagents and samples into reaction vesselsPreparing dilution series with changing volumesAliquoting liquids in the range 100 to 1,000 µLMixing solutions by repeated aspiration and dispensingMethods in which the volume changes from preparation to preparationWhen choosing, it helps to look at the volume that occurs most often in daily work. If it is close to the nominal volume, the relative measurement deviation is smaller, as the table below shows.Autoclaving and resistanceThe entire pipette may go into the autoclave at 121 °C and 1 bar for 20 minutes. Disinfectants and decontamination agents are wiped off beforehand. Filter sleeve and protective filter, where present on the model, are autoclaved separately. The pipette is UV-resistant at 254 nm. According to Eppendorf, chemical resistance is high, and special lower parts are available for aggressive chemicals. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.Technical detailsFeatureValueSeriesEppendorf Research plus, mechanicalTypeSingle-channel pipette, adjustable volumeVolume range100 to 1,000 µLStep size1 µLDisplayfour-digit volume displayColour codeblueMatching tipepT.I.P.S. 50 to 1,000 µLAutoclavablefully, 121 °C, 1 bar, 20 minutesUV resistance254 nmOperating conditions+5 °C to +40 °C, 10 to 95 % relative humidityStorage-5 °C to +45 °CStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number3123000063Measurement deviationsFor this pipette, Eppendorf specifies 3 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.Test volumeSystematic errorRandom error100 µL±3 % / ±3 µL±0.6 % / ±0.6 µL500 µL±1 % / ±5 µL±0.2 % / ±1 µL1,000 µL±0.6 % / ±6 µL±0.2 % / ±2 µLScope of deliveryPipetteOperating instructionsCertificateAdjustment tool (hex key)5 adjustment seals for temporary adjustmentPipette greaseDepending on the model, further parts are included, for example an epT.I.P.S. Box 2.0 or a sample bag with epT.I.P.S., a locking ring for deactivating the spring loading, protective filters and a pipette wrench.Accessories and procurementThe Pipette Carousel 2 and the Pipette Stand 2 from Eppendorf are also available. Further epT.I.P.S. and accessories are procured by the procurement service on request.
Brand Transferpette S Single-Channel Pipette, variable, 100-1,000 µl, DE-M, 705880
When transferring culture medium for cell culture runs of different sizes, the volume needed varies between a few hundred microlitres and one millilitre depending on vessel size. The Brand Transferpette S variable D-1000 covers 100-1,000 µl with an increment of 1 µl, without having to keep a separate device for every amount.Continuously adjustable with 1 µl incrementThe Transferpette S variable 100-1,000 µl (model D-1000) covers the volume range 100-1,000 µl in steps of 1 µl. The volume is set with a dial without tools, and a lockable position (UNLOCK/LOCK) prevents accidental adjustment during serial work. To match the volume range, Brand recommends the pipette tip size 50-1,000 µl. In total, the variable Transferpette S series comprises ten volume sizes from 0.1 µl to 10 ml, so a suitable model from the same range can be combined for almost every working range. One range smaller is the Transferpette S variable 20-200 µl (D-200, MPN 705878). One range larger follows the Transferpette S variable 0.5-5 ml (D-5000, MPN 705882).Accuracy according to DIN EN ISO 8655Tested according to DIN EN ISO 8655 at three volume levels: at the full nominal volume, the pipette achieves an accuracy A of up to ±0.6 % and a coefficient of variation CV of up to 0.2 %, at half the nominal volume ±0.8 % and 0.3 % respectively, and at the lower end, at one tenth of the nominal volume, ±3 % and 0.6 % respectively. The three test points show that the accuracy decreases towards the lower end of the volume range, an effect that occurs with every piston-operated pipette and should be taken into account when choosing the suitable model. In addition, the pipette bears the DE-M marking under German weights and measures law. The accuracy A describes the deviation of the average dispensed volume from the target value, and the coefficient of variation CV the scatter of several repetitions at this volume.Tool-free adjustment with Easy CalibrationThe Easy Calibration function allows readjustment directly on the pipette, without tools, using an adjustment slider under the label window with volume offset. A changed factory setting becomes visible through a red adjustment slider in the display window.Fully autoclavableFor sterile applications, the pipette can be autoclaved fully assembled, as a complete unit, at 121 °C and 2 bar, with a holding time of at least 15 minutes according to DIN EN 285, and dismantling is not required.Variable or fixed: which design fitsCulture vessels of different sizes need different amounts of medium, for which the variable Transferpette S D-1000 is suitable. If the same vessel format is always supplied with the same amount, a Transferpette S Fix from the same range offers simpler operation. For the D-1000 with its range of 100-1,000 µl, the specific working step therefore decides whether variable or fixed is the more suitable design.Quality certificate and warranty includedEvery pipette is supplied with a quality certificate (Performance Certificate), which can be filed into your own quality assurance. A three-year warranty applies to the single-channel pipettes of the Transferpette S series.Typical applicationsTransferring culture medium for cell culture runs of different sizesTransferring reagents and preparing stock solutionsBuffer preparation in general laboratory routineInitial laboratory equipment when a medium volume range is needed flexiblySerial work over a longer period with several volume levelsTechnical detailsModelTransferpette S variable, D-1000Volume range100-1,000 µlIncrement1 µlRecommended tip size50-1,000 µlAccuracy (A) at 100/50/10 % of nominal volume≤ ±0.6 % / ±0.8 % / ±3 %Coefficient of variation (CV) at 100/50/10 % of nominal volume≤ 0.2 % / 0.3 % / 0.6 %OperationOne-handed operation, volume lock UNLOCK/LOCKAdjustmentEasy Calibration, tool-free, adjustment slider under label windowSterilisationFully autoclavable at 121 °C, 2 bar, at least 15 minutes according to DIN EN 285MarkingDE-MScope of delivery1x Transferpette S variable 100-1,000 µl (D-1000)1x quality certificate1x silicone greaseIndividual requirements & procurement serviceIf a different volume range is needed in addition, it is worth looking at the neighbouring models of the Transferpette S series or at the starter kits with several ranges in one set. For accessories, spare parts and individual calibration, our procurement service can help.
Brand Transferpette S Starter Kit Standard, 3 Pipettes 0.5-10 / 10-100 / 100-1,000 µl, DE-M, 705893
Anyone who wants to equip a laboratory with several volume ranges in one go rarely needs just a single pipette. The Brand Transferpette S Starter Kit Standard bundles 3 variable single-channel pipettes of 0.5-10 / 10-100 / 100-1,000 µl in one set and thus covers in one go what would otherwise require several individual orders, ready for use directly in the shelf holders and typically suitable for initial laboratory equipment with the three most frequently used volume ranges in everyday microbiological and molecular biological work. This makes the commonly used combination of small, medium and large volume available immediately. All the pipettes included can be operated one after another without getting used to a different handling.3 pipettes for the complete rangeThe Starter Kit Standard combines 3 Transferpette S single-channel pipettes with variable volume: the D-10 for 0.5-10 µl with an increment of 0.01 µl, the D-100 for 10-100 µl with an increment of 0.1 µl and the D-1000 for 100-1,000 µl with an increment of 1 µl. Together the devices cover the range 0.5-10 / 10-100 / 100-1,000 µl. A matching pipette tip size is defined for each pipette, included in the set as 1x TipBox 0.5-20 µl, 1x TipBox 2-200 µl, 1x TipBox 50-1,000 µl.DE-M marking and accuracyAll pipettes in the set carry the DE-M marking under German weights and measures law, and the accuracy testing is based on DIN EN ISO 8655 with three test points per volume range (100, 50 and 10 % of the nominal volume). At the respective nominal volume, the accuracy A lies, depending on the model, between ±1 % and ±0.6 %, a level of accuracy that matters in dilution series and quantitative analyses. The accuracy A describes the deviation of the mean dispensed volume from the nominal value, the coefficient of variation CV the scatter of several repetitions at the same volume, both values increase towards the lower end of a volume range.One-handed operation and tool-free adjustmentFor series work, each pipette in the set is designed for one-handed operation, including a lock (UNLOCK/LOCK) against accidental adjustment. A deviation from the factory setting can be corrected directly and without tools using the Easy Calibration function.Autoclavable fully assembledSterile working is possible with every pipette in the set: it can be autoclaved completely, at 121 °C and 2 bar, with a holding time of at least 15 minutes according to DIN EN 285, without having to be dismantled beforehand.Quality certificate and warranty includedA quality certificate (Performance Certificate) documents the testing of the pipettes in the Starter Kit Standard. A three-year warranty applies to the single-channel pipettes of the entire Transferpette S series.Which laboratory this combination suitsFor a newly equipped laboratory without a known focus, a broad basic equipment makes more sense than specialising in one volume window. With a small, a medium and a large range, the Starter Kit Standard covers a broad basic range, before the actual requirements become apparent in operation.Advantage of the set over individual procurementChoosing the Starter Kit Standard replaces 3 individual orders and the different delivery times that come with them. Since all pipettes come from the same series, operation is identical on every device, which helps especially at workstations with changing staff. The 3 shelf holders supplied hold all 3 pipettes within easy reach between two applications, instead of leaving them lying loose on the laboratory bench.Typical applicationsInitial laboratory equipment with three volume ranges for everyday microbiological and molecular biological workDilution series and reagent addition across several volume rangesInitial equipment for newly set up workstations as well as training and further educationReplacement equipment for a second workstation with the same volume spectrumTechnical detailsCompositionTransferpette S variable, single-channel, 3-piece Starter KitVolume range D-100.5-10 µl, increment 0.01 µlVolume range D-10010-100 µl, increment 0.1 µlVolume range D-1000100-1,000 µl, increment 1 µlOperationOne-handed operation, volume lock UNLOCK/LOCKAdjustmentEasy Calibration, tool-free, adjustment slider under the label windowSterilisationAutoclavable fully assembled at 121 °C, 2 bar, at least 15 minutes according to DIN EN 285MarkingDE-MScope of delivery1x Transferpette S variable, D-10 (0.5-10 µl)1x Transferpette S variable, D-100 (10-100 µl)1x Transferpette S variable, D-1000 (100-1,000 µl)1x TipBox 0.5-20 µl, 1x TipBox 2-200 µl, 1x TipBox 50-1,000 µl, filled3 shelf holders1x quality certificate1x silicone greaseIndividual requirements & procurement serviceFor deviating requirements, both the individual models of the Transferpette S series and further sets with a different volume combination are also available. The procurement service supports with accessories, spare parts and individual calibration.
Eppendorf Research plus single-channel pipette, variable, 10–100 µL, yellow, 3123000047
The Eppendorf Research plus for 10 to 100 µL is a mechanical single-channel pipette with adjustable volume. The volume is selected in steps of 0.1 µL and read on the four-digit volume display. The colour code yellow belongs to the matching tip, namely epT.I.P.S. 2 to 200 µL.Setting the volumeVolume selection, pipetting and tip ejection are handled by separate controls. The pipette works with an air cushion. The smallest adjustable step is 0.1 µL. Anyone who pipettes preparations in many different volumes manages with an adjustable-volume pipette and does not need a set of fixed-volume pipettes.Tips and colour codeAccording to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. Here, this is the colour code yellow for epT.I.P.S. 2 to 200 µL. The colour code depends on the tip and not on the pipette volume. The pipette is an open system, and tips from other manufacturers are possible. However, the measurement deviations apply only with original epT.I.P.S.AdjustingThe pipette can be adjusted temporarily. 5 adjustment seals and an adjustment tool (hex key) are supplied for this purpose. Returning to the factory adjustment is possible without calibration.Typical applicationsTransferring reagents and samples into reaction vesselsPreparing dilution series with changing volumesAliquoting liquids in the range 10 to 100 µLMixing solutions by repeated aspiration and dispensingMethods in which the volume changes from preparation to preparationWhen choosing, it helps to look at the volume that occurs most often in daily work. If it is close to the nominal volume, the relative measurement deviation is smaller, as the table below shows.Autoclaving and resistanceThe entire pipette may go into the autoclave at 121 °C and 1 bar for 20 minutes. Disinfectants and decontamination agents are wiped off beforehand. Filter sleeve and protective filter, where present on the model, are autoclaved separately. The pipette is UV-resistant at 254 nm. According to Eppendorf, chemical resistance is high, and special lower parts are available for aggressive chemicals. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.Technical detailsFeatureValueSeriesEppendorf Research plus, mechanicalTypeSingle-channel pipette, adjustable volumeVolume range10 to 100 µLStep size0.1 µLDisplayfour-digit volume displayColour codeyellowMatching tipepT.I.P.S. 2 to 200 µLAutoclavablefully, 121 °C, 1 bar, 20 minutesUV resistance254 nmOperating conditions+5 °C to +40 °C, 10 to 95 % relative humidityStorage-5 °C to +45 °CStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number3123000047Measurement deviationsFor this pipette, Eppendorf specifies 3 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.Test volumeSystematic errorRandom error10 µL±3 % / ±0.3 µL±1 % / ±0.1 µL50 µL±1 % / ±0.5 µL±0.3 % / ±0.15 µL100 µL±0.8 % / ±0.8 µL±0.2 % / ±0.2 µLScope of deliveryPipetteOperating instructionsCertificateAdjustment tool (hex key)5 adjustment seals for temporary adjustmentPipette greaseDepending on the model, further parts are included, for example an epT.I.P.S. Box 2.0 or a sample bag with epT.I.P.S., a locking ring for deactivating the spring loading, protective filters and a pipette wrench.Accessories and procurementThe Pipette Carousel 2 and the Pipette Stand 2 from Eppendorf are also available. Further epT.I.P.S. and accessories are procured by the procurement service on request.
Eppendorf Multipette M4 hand dispenser, mechanical, 4982000012
No rechargeable battery and no charging time: the Eppendorf Multipette M4 is a mechanical hand dispenser for Combitips advanced. The volume is set and dispensed by hand; a button cell only powers the digital display. Depending on the tip, the M4 dispenses from 1 µL to 10 mL. This version is supplied with a Combitip advanced 2.5 mL and the Pipette Holder 2.Display, step counter and sleep functionThe display shows volume and steps, whilst a step counter keeps track of the number of dispensing operations. There are 20 volume settings available per tip, and up to 100 dispensing steps are possible per filling. A sleep function and motion sensor switch off the display when not in use. The CR2032 (3 V) button cell is pre-installed and, according to Eppendorf, lasts for approximately 2 years.The included CombitipThe dispenser automatically recognises the attached Combitip advanced. The supplied Combitip 2.5 mL (green) dispenses 25 to 500 µL. For other ranges there are 8 further sizes up to 50 mL; the ViscoTip for viscous liquids can also be used. If you want to try several sizes, the Starter Kit version (No. 4982000314) contains all nine sizes as an assortment pack.Typical applicationsDispensing reagents and buffers into series of tubesDispensing equal volumes without a power supply or charging stationCounting dispensing steps directly on the deviceAliquoting preparations of 25 to 500 µL per stepTechnical detailsFeatureValueSeriesEppendorf Multipette M4, mechanicalTypeHand dispenser, positive displacement principleDispensing volume1 µL to 10 mL, depending on the Combitip advanced (9 sizes from 0.1 to 50 mL)Volume settings20 per tipDispensing steps per fillingup to 100Displaydigital, for volume and steps, with step counterBatteryCR2032 button cell, 3 V, for the display only, approx. 2 yearsWeightapprox. 105 gLength20 cmOperating conditions5 to 40 °CStorage-25 to 60 °CAutoclavablenoUV resistance254 nmStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number4982000012Measurement deviationsFor each of the 9 Combitip sizes, Eppendorf specifies 4 test volumes. According to Eppendorf, the values apply only with original Combitips advanced. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The table shows the smallest and the largest test volume for each Combitip. The systematic error describes how far the mean value deviates from the set volume, the random error the scatter of the individual values.Combitip advancedTest volumeSystematic errorRandom error0.1 mL1 µL±8 %±13 %20 µL±1 %±2 %0.2 mL2 µL±6 %±8 %40 µL±0.8 %±1.5 %0.5 mL5 µL±4 %±8 %100 µL±0.8 %±0.6 %1 mL10 µL±4 %±8 %200 µL±0.6 %±0.4 %2.5 mL25 µL±4 %±8 %500 µL±0.5 %±0.3 %5 mL50 µL±3 %±5 %1 mL±0.5 %±0.25 %10 mL100 µL±3 %±4 %2 mL±0.5 %±0.25 %25 mL250 µL±3 %±3 %5 mL±0.3 %±0.25 %50 mL500 µL±6 %±10 %10 mL±0.3 %±0.25 %Scope of deliveryHand dispenserBattery (inserted)Operating instructionsCertificate1 Combitip advanced 2.5 mL (green)Pipette Holder 2Accessories and procurementAlso available are Pipette Stand 2 for the M4 and Pipette Carousel 2 from Eppendorf. The carousel holder for the M4 is a separate item. The procurement service arranges further Combitips advanced on request.
Eppendorf Reference 2 single-channel pipette, variable, 100–1,000 µL, blue, 4924000088
A magnifier window above the four-digit display makes the set volume easy to read, and a volume lock holds it in place. The Eppendorf Reference 2 for 100 to 1,000 µL is a mechanical single-channel pipette with one-button operation. The volume is set in steps of 1 µL, and the colour code blue belongs to the tip epT.I.P.S. 50 to 1,000 µL.One button for everythingAccording to Eppendorf, volume selection, pipetting and tip ejection are carried out with a single control element. According to Eppendorf, haptic feedback is intended to prevent unintentional tip ejection. The data sheet also mentions active aerosol reduction. The surface of the pipette is smooth, and the pipette works with an air cushion.Tips and colour codeAccording to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. Here, the colour code blue applies for epT.I.P.S. 50 to 1,000 µL. The colour code depends on the tip and not on the pipette volume. The pipette is an open system, and tips from other manufacturers are possible. The measurement deviations apply only with original epT.I.P.S.AdjustmentThe scope of delivery includes 1 adjustment seal for temporary adjustment and 2 adjustment seals for factory adjustment. Temporary adjustment allows adaptation to the liquid, to extended tips or to the altitude without calibrating. It is possible to return to the factory adjustment.Typical applicationsTransferring samples and reagents in the range 100 to 1,000 µL into vesselsDilution series with frequently changing volumesAliquoting from stock solutionsWork in which the set volume is to remain unchanged for longer periodsLong pipetting series with a single control elementAutoclaving and resistanceThe pipette may go into the autoclave in the assembled state at 121 °C and 1 bar for 20 minutes, upper and lower part together. No additional disinfectants or sodium hypochlorite are used. Filter sleeve and protective filter, where present on the model, are autoclaved separately. The pipette is UV-resistant at 254 nm. According to Eppendorf, chemical resistance is high, and special lower parts are available for aggressive chemicals. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.Technical detailsFeatureValueSeriesEppendorf Reference 2, mechanicalTypeSingle-channel pipette, adjustable volumeVolume range100 to 1,000 µLStep size1 µLOperationOne-button operationDisplayfour-digit, with magnifier window and volume lockColour codeblueMatching tipepT.I.P.S. 50 to 1,000 µLAutoclavablefully, 121 °C, 1 bar, 20 minutesUV resistance254 nmOperating conditions+5 °C to +40 °C, 10 to 95 % relative humidityStorage-5 °C to +45 °CStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number4924000088Measurement deviationsFor this pipette, Eppendorf specifies 3 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.Test volumeSystematic errorRandom error100 µL±3 % / ±3 µL±0.6 % / ±0.6 µL500 µL±1 % / ±5 µL±0.2 % / ±1 µL1,000 µL±0.6 % / ±6 µL±0.2 % / ±2 µLScope of deliveryPipetteOperating instructionsCertificate1 adjustment seal for temporary adjustment2 adjustment seals for factory adjustmentPipette greaseDepending on the model, further parts are included, for example an epT.I.P.S. Box 2.0 or a sample bag with epT.I.P.S., a locking ring for deactivating the spring loading, a filter sleeve with filter inserts and a pipette wrench.Accessories and procurementThe Pipette Carousel 2 and the Pipette Stand 2 from Eppendorf are also available. Further epT.I.P.S. are procured by the procurement service on request.
Eppendorf Research plus single-channel pipette set, pack of 3, 0.5–10 µL / 10–100 µL / 100–1,000 µL, 3123000900
Three pipettes from 0.5 µL to 1 mL, three colour codes: the Option 1 set of the Eppendorf Research plus contains mechanical single-channel pipettes for 0.5 to 10 µL (colour code medium grey), 10 to 100 µL (yellow) and 100 to 1,000 µL (blue). Each takes its own type of tip.Tips and colour codeAccording to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. Medium grey belongs to epT.I.P.S. 0.1 to 20 µL, yellow to 2 to 200 µL, blue to 50 to 1,000 µL. The colour code depends on the tip, not on the pipette volume. The pipettes are open systems, tips from other manufacturers are possible. The measurement deviations apply only with original epT.I.P.S.Operation and adjustmentVolume selection, pipetting and tip ejection run via separate controls. The volume is shown on a four-digit display, the pipettes work with an air cushion. The pipettes can be adjusted temporarily; returning to the factory adjustment is possible without calibration. According to Eppendorf, the spring-loaded tip cone belongs to all Research plus pipettes up to 1 mL.Typical applicationsTransferring reagents and samples from 0.5 to 10 µL into reaction vesselsAliquoting volumes from 10 to 100 µLTransferring buffers and solutions up to 1,000 µLSerial dilutions across three pipettes and several orders of magnitudeAutoclavingAll three pipettes may go into the autoclave completely at 121 °C and 1 bar for 20 minutes. Disinfectants and decontamination agents are wiped off beforehand. Filter sleeve and protective filter, where present, are autoclaved separately. The pipettes are UV-resistant at 254 nm.Technical detailsFeatureValueSeriesEppendorf Research plus, mechanicalEppendorf designationOption 1TypeSet of 3 single-channel pipettes, adjustable volume, mechanicalPipette 10.5 to 10 µL, colour code medium grey, epT.I.P.S. 0.1 to 20 µLPipette 210 to 100 µL, colour code yellow, epT.I.P.S. 2 to 200 µLPipette 3100 to 1,000 µL, colour code blue, epT.I.P.S. 50 to 1,000 µLWeight of pipette 100 to 1,000 µL80 g according to the Eppendorf data sheetAutoclavablefully, 121 °C, 1 bar, 20 minutesStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number3123000900Measurement deviationsEppendorf specifies three or four test volumes per pipette. According to Eppendorf, the values apply only with original epT.I.P.S. They are determined gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume, the random error the scatter of the individual values.PipetteTest volumeSystematic errorRandom error0.5 to 10 µL0.5 µL±8 % / ±0.04 µL±5 % / ±0.025 µL1 µL±2.5 % / ±0.025 µL±1.8 % / ±0.018 µL5 µL±1.5% / ±0.075 µL±0.8 % / ±0.04 µL10 µL±1 % / ±0.1 µL±0.4 % / ±0.04 µL10 to 100 µL10 µL±3 % / ±0.3 µL±1 % / ±0.1 µL50 µL±1 % / ±0.5 µL±0.3% / ±0.15 µL100 µL±0.8 % / ±0.8 µL±0.2% / ±0.2 µL100 to 1,000 µL100 µL±3 % / ±3 µL±0.6% / ±0.6 µL500 µL±1 % / ±5 µL±0.2 % / ±1 µL1 mL±0.6% / ±6 µL±0.2 % / ±2 µLScope of delivery3 single-channel pipettes (see table)3 epT.I.P.S. Box 2.0, each containing 96 tipsBallpoint penAccessories and procurementPipette Carousel 2 and Pipette Stand 2 from Eppendorf are also available. The procurement service arranges further epT.I.P.S. on request.
Eppendorf Research plus single-channel pipette set, pack of 3, 2–20/20–200/100–1,000 µL, 3123000918
Yellow, yellow, blue: in the Option 2 set of the Eppendorf Research plus, the pipettes for 2 to 20 µL and 20 to 200 µL share the tip epT.I.P.S. 2 to 200 µL, both with colour code yellow. The third pipette for 100 to 1,000 µL has the colour code blue and takes epT.I.P.S. 50 to 1,000 µL.One tip type for two pipettesThe 2 to 20 µL pipette is also available from Eppendorf in light grey with epT.I.P.S. 0.5 to 20 µL L. In this set it is the yellow version. Anyone who already has yellow tips in stock in the laboratory covers two of the three pipettes with them. The measurement deviations apply only with original epT.I.P.S., but the pipettes are open systems.Operation and adjustmentVolume selection, pipetting and tip ejection run via separate controls. The volume is shown on a four-digit display, the pipettes work with an air cushion. The pipettes can be adjusted temporarily; returning to the factory adjustment is possible without calibration. According to Eppendorf, the spring-loaded tip cone belongs to all Research plus pipettes up to 1 mL.Typical applicationsSmall volumes of 2 to 20 µL for preparations and samplesDispensing aliquots of 20 to 200 µL from stock solutionsTransferring buffers and solutions up to 1,000 µLWorkstations where all three applications are used on a daily basisAutoclavingAll three pipettes may go into the autoclave completely at 121 °C and 1 bar for 20 minutes. Disinfectants and decontamination agents are wiped off beforehand. Filter sleeve and protective filter, where present, are autoclaved separately. The pipettes are UV-resistant at 254 nm.Technical detailsFeatureValueSeriesEppendorf Research plus, mechanicalEppendorf designationOption 2TypeSet of 3 single-channel pipettes, adjustable volume, mechanicalPipette 12 to 20 µL, colour code yellow, epT.I.P.S. 2 to 200 µLPipette 220 to 200 µL, colour code yellow, epT.I.P.S. 2 to 200 µLPipette 3100 to 1,000 µL, colour code blue, epT.I.P.S. 50 to 1,000 µLWeight of pipette 100 to 1,000 µL80 g according to the Eppendorf data sheetAutoclavablefully, 121 °C, 1 bar, 20 minutesStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number3123000918Measurement deviationsEppendorf specifies three or four test volumes per pipette. According to Eppendorf, the values apply only with original epT.I.P.S. They are determined gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume, the random error the scatter of the individual values.PipetteTest volumeSystematic errorRandom error2 to 20 µL2 µL±5 % / ±0.1 µL±1.5 % / ±0.03 µL10 µL±1.2% / ±0.12 µL±0.6 % / ±0.06 µL20 µL±1 % / ±0.2 µL±0.3 % / ±0.06 µL20 to 200 µL20 µL±2.5 % / ±0.5 µL±0.7 % / ±0.14 µL100 µL±1 % / ±1 µL±0.3 % / ±0.3 µL200 µL±0.6 % / ±1.2 µL±0.2 % / ±0.4 µL100 to 1,000 µL100 µL±3 % / ±3 µL±0.6% / ±0.6 µL500 µL±1 % / ±5 µL±0.2 % / ±1 µL1 mL±0.6% / ±6 µL±0.2 % / ±2 µLScope of delivery3 single-channel pipettes (see table)3 epT.I.P.S. Box 2.0, each containing 96 tipsBallpoint penAccessories and procurementPipette Carousel 2 and Pipette Stand 2 from Eppendorf are also available. The procurement service arranges further epT.I.P.S. on request.
Brand Dispensette S Bottle-Top Dispenser, Digital, 2.5-25 ml, with Recirculation Valve, DE-M, 4600351
Anyone in the laboratory who repeatedly needs to prepare larger quantities of buffer wants to be able to read the volume without estimating the scale by eye. With 2.5 to 25 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.Accuracy and graduationAccuracy is 0.5 %/125 µl, the coefficient of variation figure 0.1 %/25 µl, the graduation 0.1 ml. These values apply to all volumes set within the range 2.5 to 25 ml and were determined according to the general test procedure for piston-stroke devices.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Recirculation functionThis version has a recirculation valve. Excess liquid can thus be returned to the stock bottle without opening the discharge tube or removing the bottle. This is practical with expensive or hazardous reagents, for example when a calibration check needs several back-weighings or when too much volume was dispensed by mistake.Mounting and handlingThe Dispensette S Digital is mounted directly on the stock bottle using the bottle adapter supplied, and the telescopic filling tube can be shortened to the bottle height. The mounting key is part of the scope of delivery and is needed when changing the valve or discharge tube. After fitting, the device is drawn up and dispensed into a waste container several times until there are no more air bubbles in the system, after which it is ready for use.Media compatibilityThe range of media includes aggressive reagents, highly concentrated acids such as phosphoric or sulphuric acid, salt solutions and many organic solvents. By contrast, hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids must not be dispensed. The yellow Organic variant is intended for concentrated hydrochloric and nitric acid, THF and trifluoroacetic acid; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time around 2 hours in the closed autoclave. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Distinction within the Dispensette S standard seriesThe three versions of the Dispensette S standard series differ in the way the volume is set, not in accuracy. Anyone who changes more often between volumes within the stated range gets on fastest with the Digital display. Anyone who is comfortable with a mechanical scale saves on purchase cost with the Analog version. And anyone who permanently needs only one volume gets by most easily with the Fix version.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 2.5 to 25 ml intended?Typical uses include reagent addition for larger sample series, this volume range is intended for such applications.Typical applicationsPreparing larger quantities of bufferDilution series in the ml rangeReagent addition for larger sample seriesTechnical detailsLineBrand Dispensette S, DigitalVolume2.5 to 25 mlGraduation0.1 mlAccuracy0.5 %/125 µlCoefficient of variation0.1 %/25 µlRecirculation valveyesMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavability121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time around 2 hours in the closed autoclaveMarkingDE-MManufacturer article no.4600351Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tube including recirculation tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support via our procurement service.
Eppendorf Research plus single-channel pipette, variable, 20–200 µL, yellow, 3123000055
The Eppendorf Research plus for 20 to 200 µL is a mechanical single-channel pipette with adjustable volume. The volume is selected in steps of 0.2 µL and read on the four-digit volume display. The colour code yellow belongs to the matching tip, namely epT.I.P.S. 2 to 200 µL.Setting the volumeVolume selection, pipetting and tip ejection are handled by separate controls. The pipette works with an air cushion. The smallest adjustable step is 0.2 µL. Anyone who pipettes preparations in many different volumes manages with an adjustable-volume pipette and does not need a set of fixed-volume pipettes.Tips and colour codeAccording to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. Here, this is the colour code yellow for epT.I.P.S. 2 to 200 µL. The colour code depends on the tip and not on the pipette volume. The pipette is an open system, and tips from other manufacturers are possible. However, the measurement deviations apply only with original epT.I.P.S.AdjustingThe pipette can be adjusted temporarily. 5 adjustment seals and an adjustment tool (hex key) are supplied for this purpose. Returning to the factory adjustment is possible without calibration.Typical applicationsTransferring reagents and samples into reaction vesselsPreparing dilution series with changing volumesAliquoting liquids in the range 20 to 200 µLMixing solutions by repeated aspiration and dispensingMethods in which the volume changes from preparation to preparationWhen choosing, it helps to look at the volume that occurs most often in daily work. If it is close to the nominal volume, the relative measurement deviation is smaller, as the table below shows.Autoclaving and resistanceThe entire pipette may go into the autoclave at 121 °C and 1 bar for 20 minutes. Disinfectants and decontamination agents are wiped off beforehand. Filter sleeve and protective filter, where present on the model, are autoclaved separately. The pipette is UV-resistant at 254 nm. According to Eppendorf, chemical resistance is high, and special lower parts are available for aggressive chemicals. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.Technical detailsFeatureValueSeriesEppendorf Research plus, mechanicalTypeSingle-channel pipette, adjustable volumeVolume range20 to 200 µLStep size0.2 µLDisplayfour-digit volume displayColour codeyellowMatching tipepT.I.P.S. 2 to 200 µLAutoclavablefully, 121 °C, 1 bar, 20 minutesUV resistance254 nmOperating conditions+5 °C to +40 °C, 10 to 95 % relative humidityStorage-5 °C to +45 °CStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number3123000055Measurement deviationsFor this pipette, Eppendorf specifies 3 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.Test volumeSystematic errorRandom error20 µL±2.5 % / ±0.5 µL±0.7 % / ±0.14 µL100 µL±1 % / ±1 µL±0.3 % / ±0.3 µL200 µL±0.6 % / ±1.2 µL±0.2 % / ±0.4 µLScope of deliveryPipetteOperating instructionsCertificateAdjustment tool (hex key)5 adjustment seals for temporary adjustmentPipette greaseDepending on the model, further parts are included, for example an epT.I.P.S. Box 2.0 or a sample bag with epT.I.P.S., a locking ring for deactivating the spring loading, protective filters and a pipette wrench.Accessories and procurementThe Pipette Carousel 2 and the Pipette Stand 2 from Eppendorf are also available. Further epT.I.P.S. and accessories are procured by the procurement service on request.
Brand Transferpette S Pipette Package 2, 5 Single-Channel Pipettes, variable, 0.5 µl to 5 ml, DE-M, 705897
Anyone who wants to equip a laboratory completely with high-precision piston-operated pipettes rarely needs just a single volume. With five variable single-channel pipettes, the Brand Transferpette S Pipette Package 2 covers the complete range from 0.5 µl to 5 ml and so provides initial equipment in one go, for PCR and molecular biology workstations as well as for preparative sample preparation, ready for use in the practical bench stand and without having to collect additional individual pipettes. Five pipettes for the complete working range Pipette Package 2 combines five Transferpette S single-channel pipettes with variable volume: the D-10 for 0.5 to 10 µl with an increment of 0.01 µl, the D-100 for 10 to 100 µl with an increment of 0.1 µl, the D-200 for 20 to 200 µl with an increment of 0.2 µl, the D-1000 for 100 to 1,000 µl with an increment of 1 µl and the D-5000 for 500 to 5,000 µl with an increment of 5 µl. Together, the five devices cover the range from 0.5 µl to 5 ml without gaps, from the smallest PCR reactions to larger volumes in preparative sample preparation. Matching tip sizes are also defined for each of the five pipettes, from 0.5 to 20 µl for the D-10, through 2 to 200 µl for D-100 and D-200, up to 50 to 1,000 µl for the D-1000 and 500 to 5,000 µl for the D-5000. DE-M marking and accuracy All five pipettes carry the DE-M marking under German weights and measures law as well as the CE marking, and the accuracy is tested according to DIN EN ISO 8655. At the respective nominal volume, the D-10 achieves an accuracy A of up to ±1 % with a coefficient of variation CV of up to 0.5 %. The four larger models D-100, D-200, D-1000 and D-5000 each have an accuracy A of up to ±0.6 % and a coefficient of variation CV of up to 0.2 %, a level of accuracy that counts particularly in quantitative analyses and dilution series. One-handed operation for fatigue-free work Volume adjustment, pipetting and tip ejection can all be carried out with one hand on the Transferpette S, so there is no change of grip during serial work. A lockable volume setting with UNLOCK and LOCK position prevents the set volume from being changed accidentally during intensive use, a detail that pays off above all in long pipetting series in everyday laboratory work and lowers the error rate in repeated pipetting steps. Tool-free adjustment with Easy Calibration If the factory setting drifts, every pipette can be adjusted directly using the Easy Calibration function without any additional tool. A red adjustment slider in the display window shows when the factory setting has been changed, so it is visible at a glance whether the pipette is still running on its original calibration or has been readjusted. Autoclavable fully assembled For use in sterile areas, all five pipettes can be autoclaved fully assembled, at 121 °C and 2 bar with a holding time of at least 15 minutes according to DIN EN 285. Dismantling before sterilisation is therefore not necessary, which significantly reduces the effort for recurring sterilisation cycles in the laboratory. A tidy workstation with the carousel bench stand The bench stand supplied holds up to six devices as a carousel and so keeps the workstation clear even with five pipettes. All devices stand within reach and protected between two uses, instead of lying loose on the laboratory bench or contaminating each other. Quality certificate and warranty included Pipette Package 2 comes with a quality certificate (Performance Certificate) that documents the testing of the individual pipettes and can be filed directly into your own quality assurance. A three-year warranty applies to the single-channel pipettes of the Transferpette S series. Typical applications PCR reactions and master mix pipetting in molecular biology with D-10 and D-100 ELISA and other microtitre plate applications with D-100 and D-200 Dilution series and buffer preparation in general laboratory routine with D-200 and D-1000 Preparative sample preparation and larger volumes, for example when transferring reagents or preparing stock solutions, with D-1000 and D-5000 Initial laboratory equipment for newly set up workstations as well as for education and training, where different volume ranges are needed at the same time Technical details Model seriesTransferpette S, variable, single-channel, 5-piece package Volume range D-100.5-10 µl, increment 0.01 µl Volume range D-10010-100 µl, increment 0.1 µl Volume range D-20020-200 µl, increment 0.2 µl Volume range D-1000100-1,000 µl, increment 1 µl Volume range D-5000500-5,000 µl (0.5-5 ml), increment 5 µl Recommended tips D-100.5-20 µl Recommended tips D-100 / D-2002-200 µl Recommended tips D-100050-1,000 µl Recommended tips D-5000500-5,000 µl Accuracy (A) D-10 at nominal volume≤ ±1 % Coefficient of variation (CV) D-10 at nominal volume≤ 0.5 % Accuracy (A) D-100 / D-200 / D-1000 / D-5000 at nominal volume≤ ±0.6 % Coefficient of variation (CV) D-100 / D-200 / D-1000 / D-5000 at nominal volume≤ 0.2 % OperationOne-handed operation for volume setting, pipetting and tip ejection Volume lockUNLOCK / LOCK AdjustmentEasy Calibration, tool-free, red adjustment slider in display window SterilisationAutoclavable fully assembled at 121 °C, 2 bar, holding time at least 15 minutes according to DIN EN 285 MarkingDE-M, CE Test standardDIN EN ISO 8655 (accuracy testing) Warranty3 years on single-channel pipettes Scope of delivery 1x Transferpette S, variable, D-10 (0.5-10 µl) 1x Transferpette S, variable, D-100 (10-100 µl) 1x Transferpette S, variable, D-200 (20-200 µl) 1x Transferpette S, variable, D-1000 (100-1,000 µl) 1x Transferpette S, variable, D-5000 (500-5,000 µl) 4x TipBox pipette tips, filled: 1x 0.5-20 µl, 1x 2-200 µl, 1x 50-1,000 µl, 1x 0.5-5 ml 1x bench stand (carousel for 6 devices) 1x quality certificate (Performance Certificate) 1x silicone grease Individual requirements & procurement service Anyone who does not need the complete 5-piece equipment can also choose smaller Transferpette S starter kits, for example in the combinations Micro, Midi, Macro or Standard, with a reduced pipette selection for narrower requirements or a smaller budget. For additional individual pipettes, suitable pipette tips, spare parts, calibration or individual combinations, our procurement service can help.
Brand Dispensette S Bottle-Top Dispenser, Digital, 5-50 ml, without Recirculation Valve, DE-M, 4600360
Anyone who repeatedly has to portion media in the microbiology laboratory wants to be able to read the volume without estimating the scale by eye. With 5 to 50 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.Without recirculation valveThis version works without a recirculation valve. The design is therefore simpler, with one less moving part in the dispensing path. For applications where every dispensed volume goes directly into the target vessel and no return is needed, this slimmer design is sufficient.Mounting and handlingThe bottle adapter from the scope of delivery is screwed onto the stock bottle, and the telescopic filling tube can be shortened to the bottle height. Before first use, the device is drawn up and dispensed into a waste container several times until the system is free of air bubbles. The mounting key is needed later when changing the valve or discharge tube.Media compatibilitySuitable for aggressive reagents, concentrated alkalis and acids such as phosphoric acid or sulphuric acid, salt solutions and many organic solvents. Not suitable for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids. The yellow Dispensette S Organic is intended for concentrated hydrochloric and nitric acid, THF and trifluoroacetic acid; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: steam sterilisation at 121 °C and 2 bar gauge pressure for at least 15 minutes according to DIN EN 285, followed by about 2 hours of cooling time in the closed autoclave. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Distinction within the Dispensette S standard seriesWithin the Dispensette S standard series, Digital, Analog and Fix differ mainly in volume setting. Digital shows the set volume on the mechanical counter and is suitable when different values are often needed within the range. Analog achieves the same accuracy via a scale on the cylinder without a counter. Fix dispenses only a single, factory-adjusted volume and thus reduces the risk of accidental changes. Anyone who constantly needs the same volume range and no variation gets by more cheaply and with simpler handling with a Fix version.Accuracy and graduationAccuracy is 0.5 %/250 µl, the coefficient of variation 0.1 %/50 µl, the graduation 0.2 ml. These values apply to all volumes set within the range 5 to 50 ml and were determined according to the general test procedure for piston-stroke devices.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 5 to 50 ml intended?Typical uses include the preparation of culture solutions and buffers in larger batches.Typical applicationsMedia portioning in the microbiology laboratoryFilling larger quantities of reagentPreparing culture solutions and buffers in larger batchesTechnical detailsLineBrand Dispensette S, DigitalVolume5 to 50 mlGraduation0.2 mlAccuracy0.5 %/250 µlCoefficient of variation0.1 %/50 µlRecirculation valvenoMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavabilitysteam sterilisation at 121 °C and 2 bar gauge pressure for at least 15 minutes according to DIN EN 285, followed by about 2 hours of cooling time in the closed autoclaveMarkingDE-MManufacturer article no.4600360Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support via our procurement service.
Brand Transferpette S Pipette Package 1, 5 Pipettes 0.1 µl to 1 ml, DE-M, 705896
Anyone who wants to equip a laboratory with several volume ranges in one go rarely needs just a single pipette. The Brand Transferpette S Pipette Package 1 bundles 5 variable single-channel pipettes from 0.1 µl to 1 ml in one combination and so covers at once what would otherwise take several individual orders, ready for use in the stand and typically suited to a complete initial laboratory equipment across five volume ranges, from PCR volumes to preparative sample preparation. This reduces the coordination effort compared with several individual orders with different delivery times.5 pipettes for the complete rangePipette Package 1 combines 5 Transferpette S single-channel pipettes with variable volume: the D-2.5 for 0.1-2.5 µl with an increment of 0.002 µl, the D-10 for 0.5-10 µl with an increment of 0.01 µl, the D-20 for 2-20 µl with an increment of 0.02 µl, the D-200 for 20-200 µl with an increment of 0.2 µl and the D-1000 for 100-1,000 µl with an increment of 1 µl. Together, the devices cover the range 0.1 µl to 1 ml. A matching pipette tip size is defined for each pipette, included in the set as 3x TipBox.DE-M marking and accuracyAll pipettes in the set carry the DE-M marking under German weights and measures law, and the accuracy testing is based on DIN EN ISO 8655 with three test points per volume range (100, 50 and 10 % of the nominal volume). At the respective nominal volume, the accuracy A is between ±1.4 % and ±0.6 % depending on the model, a level of accuracy that matters for dilution series and quantitative analyses. The accuracy A describes the deviation of the average dispensed volume from the target value, and the coefficient of variation CV the scatter of several repetitions at the same volume. Both values increase towards the lower end of a volume range.One-handed operation and tool-free adjustmentEvery pipette in the set is operated with one hand, from volume setting to tip ejection, protected by a lock (UNLOCK/LOCK). Adjustment is tool-free using Easy Calibration, and an adjustment slider under the label window shows a changed factory setting.Autoclavable fully assembledEvery pipette in the set withstands autoclaving in the assembled state, as a complete unit, at 121 °C and 2 bar, with a holding time of at least 15 minutes according to DIN EN 285, and dismantling before sterilisation is not required.Quality certificate and warranty includedA quality certificate (Performance Certificate) is enclosed with the set, which can be filed directly into your own quality assurance. The single-channel pipettes of the Transferpette S series are covered by a three-year warranty.Which laboratory this combination suitsA laboratory that covers both PCR preparation in very small volumes and larger sample preparation up to 1 ml usually cannot manage with a single starter kit. With five volume ranges, Pipette Package 1 closes the gap between the smaller kits and so covers a complete molecular biology workstation in one go.Advantage of the set over individual procurementFor a newly set up laboratory, Pipette Package 1 covers 5 volume ranges in a single process, instead of collecting them one by one. All devices come from the same series and are operated in the same way, which makes training easier. The bench stand supplied keeps all 5 pipettes within reach between two uses, instead of leaving them lying loose on the laboratory bench.Typical applicationscomplete initial laboratory equipment across five volume ranges, from PCR volumes to preparative sample preparationDilution series and adding reagents across several volume rangesInitial laboratory equipment for newly set up workstations as well as education and trainingSetting up an additional workstation without several individual ordersTechnical detailsCombinationTransferpette S variable, single-channel, 5-piece pipette packageVolume range D-2.50.1-2.5 µl, increment 0.002 µlVolume range D-100.5-10 µl, increment 0.01 µlVolume range D-202-20 µl, increment 0.02 µlVolume range D-20020-200 µl, increment 0.2 µlVolume range D-1000100-1,000 µl, increment 1 µlOperationOne-handed operation, volume lock UNLOCK/LOCKAdjustmentEasy Calibration, tool-free, adjustment slider under label windowSterilisationAutoclavable fully assembled at 121 °C, 2 bar, at least 15 minutes according to DIN EN 285MarkingDE-MScope of delivery1x Transferpette S variable, D-2.5 (0.1-2.5 µl)1x Transferpette S variable, D-10 (0.5-10 µl)1x Transferpette S variable, D-20 (2-20 µl)1x Transferpette S variable, D-200 (20-200 µl)1x Transferpette S variable, D-1000 (100-1,000 µl)3x TipBox, filled1x bench stand1x quality certificate1x silicone greaseIndividual requirements & procurement serviceIf this combination does not fit completely, further Transferpette S sets and individual models with a different volume combination are also available. For pipette tips, spare parts and larger quantities, our procurement service can help.
Brand Dispensette S Organic bottle-top dispenser, Analog, 1-10 ml, with recirculation valve, DE-M, 4630141
In standardised digestion procedures with concentrated nitric acid, daily venting should not cost any reagent. The Brand Dispensette S Organic Analog with recirculation valve (1 to 10 ml) returns excess volume to the stock bottle instead of discarding it via the discharge tube. At 1-10 ml the graduation is 0.2 ml, the accuracy is 0.5 %/50 µl and the coefficient of variation is 0.1 %/10 µl.Typical applicationsThe yellow colour code identifies the Organic series in the Brand range. Typical applications for 1-10 ml:Venting before standardised digestion with concentrated nitric acid, without reagent lossrecurring addition of organic solvents, with excess volume returnedfixed THF dispensing in synthesis, with refilling without lossAnalog version and selection guideThe volume is set using the volume adjustment screw with indicator arrow: loosen the screw by three quarters of a turn, slide the indicator arrow to the scale value, and tighten the screw again. Once set, the value stays until deliberately changed. Analog devices can be adjusted without tools via Easy Calibration. Matching bottle adapters for GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 are included, and the filling tube can be adjusted to 125-240 mm.With a fixed but expensive acid volume in routine work, the recirculation valve pays off when venting. For inexpensive media, the version without recirculation valve is sufficient.Materials and autoclavabilityWetted parts are made of borosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter). The device is autoclavable under the following conditions: 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclave. Tantalum as the valve spring material, together with the fluoroplastics ETFE, FEP, PFA and PTFE, makes the Organic series suitable for organic solvents and some concentrated acids, but not for alkaline solutions and salt solutions.The Dispensette S Organic is not suitable for alkaline solutions, salt solutions, carbon disulphide, explosive liquids and media that attack borosilicate glass, such as hydrofluoric acid. For alkaline solutions and salt solutions, the Dispensette S in red (standard) is the suitable series, and for trace analysis with a selectable valve spring of platinum-iridium or tantalum, the Dispensette S Trace Analysis.Assembly and changing to a different stock bottle are done with the supplied mounting key and the telescopic filling tube, which can be adjusted to the respective bottle height. The bottle adapter included in the scope of delivery fits the respective GL45-compatible thread and makes the dispenser usable regardless of the specific stock bottle.Accuracy at a glanceFor 1-10 ml: graduation 0.2 ml, accuracy 0.5 %/50 µl, coefficient of variation 0.1 %/10 µl. The DE-M marking in the product name refers to conformity assessment under German weights and measures law; it does not replace a calibration certificate.Other volumes in the Analog versionIf you need a range other than 1-10 ml, you will find it within the Analog version of the Dispensette S Organic:VolumeAccuracyMPN (without recirculation valve)0.5-5 ml0.5 %/25 µl46301302.5-25 ml0.5 %/125 µl46301505-50 ml0.5 %/250 µl463016010-100 ml0.5 %/500 µl4630170Frequently asked questionsWhat is the recirculation valve needed for?It allows the dispensing system to be vented before first use without losing any reagent: air and excess volume go back into the stock bottle via the recirculation tube instead of into waste. This is particularly relevant with expensive or environmentally relevant solvents.How is the Analog version adjusted in the 1-10 ml range?With Easy Calibration this can be done without additional tools; a changed factory adjustment is shown by a red marking.Technical detailsVersionAnalogRecirculation valveyes, incl. recirculation tubeVolume range1-10 mlGraduation0.2 mlAccuracy (A)0.5 %/50 µlCoefficient of variation (CV)0.1 %/10 µlColour codeyellow (Organic)Valve springTantalumWetted materialsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter)Autoclavableyes, 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclaveThreadGL45Adapter/filling tubeAdapters: GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40; filling tube 125-240 mm; incl. recirculation tubeScope of delivery1 Dispensette S Organic bottle-top dispenser for GL45 threaded bottlesDischarge tube with recirculation valve, including recirculation tubeTelescopic filling tubeMounting keyBottle adapter matching the volume rangeQuality certificateOperating instructionsDistinction within the Dispensette S familyYellow colour code means: suitable for organic solvents and for concentrated hydrochloric acid and nitric acid. For alkaline solutions and the other acids, the red standard Dispensette S still applies. For trace analysis with a selectable valve spring of platinum-iridium or tantalum, the Dispensette S Trace Analysis is available separately.Individual requirements & procurement serviceWe provide support via our own procurement service with suitable bottle adapters, spare parts and further volume ranges of this series.
Brand Dispensette S Bottle-Top Dispenser, Digital, 1-10 ml, with Recirculation Valve, DE-M, 4600341
Anyone in the laboratory who repeatedly needs a routine reagent addition wants to be able to read the volume without estimating the scale by eye. With 1 to 10 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.Media compatibilityThe red standard version tolerates a wide range of reagents: concentrated acids such as phosphoric acid and sulphuric acid, concentrated alkalis, salt solutions and numerous organic solvents. Excluded are hydrofluoric acid as well as hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids. Anyone who regularly dispenses concentrated hydrochloric or nitric acid should choose the yellow Dispensette S Organic; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: sterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours of cooling time in the closed device. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Distinction within the Dispensette S standard seriesWithin the Dispensette S standard series, Digital, Analog and Fix differ mainly in volume setting. Digital shows the set volume on the mechanical counter and is suitable when different values are often needed within the range. Analog achieves the same accuracy via a scale on the cylinder without a counter. Fix dispenses only a single, factory-adjusted volume and thus reduces the risk of accidental changes. Anyone who constantly needs the same volume range and no variation gets by more cheaply and with simpler handling with a Fix version.Accuracy and graduationAccuracy is 0.5 %/50 µl, the coefficient of variation figure 0.1 %/10 µl, the graduation 0.05 ml. These values apply to all volumes set within the range 1 to 10 ml and were determined according to the general test procedure for piston-stroke devices.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Recirculation functionThis version has a recirculation valve. Excess liquid can thus be returned to the stock bottle without opening the discharge tube or removing the bottle. This is practical with expensive or hazardous reagents, for example when a calibration check needs several back-weighings or when too much volume was dispensed by mistake.Mounting and handlingThe bottle adapter from the scope of delivery is screwed onto the stock bottle, and the telescopic filling tube can be shortened to the bottle height. Before first use, the device is drawn up and dispensed into a waste container several times until the system is free of air bubbles. The mounting key is needed later when changing the valve or discharge tube.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 1 to 10 ml intended?Typical uses include recurring additions in analysis series, this volume range is intended for such applications.Typical applicationsRoutine reagent addition in the laboratoryBuffer preparation in common volumesrecurring additions in analysis seriesTechnical detailsLineBrand Dispensette S, DigitalVolume1 to 10 mlGraduation0.05 mlAccuracy0.5 %/50 µlCoefficient of variation0.1 %/10 µlRecirculation valveyesMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavabilitySterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours of cooling time in the closed deviceMarkingDE-MManufacturer article no.4600341Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tube including recirculation tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support via our procurement service.
Eppendorf Multipette E3 Hand Dispenser, Electronic, 4987000010
Aspirate a volume and dispense it in up to 100 equal steps: the Eppendorf Multipette E3 is an electronic hand dispenser for Combitips advanced. Depending on the tip, it dispenses 1 µL to 50 mL. The E3 works with three modes and is therefore the simpler of the two versions.Three modes for standard tasksDispensing (Dis), automatic dispensing (Ads) and pipetting (Pip) cover the distribution of equal volumes and the single aspiration and dispensing of a volume. Serial dilutions, aspiration and titration are not included. The Multipette E3x with manufacturer number 4987000029 is available for these. Those who mainly dispense do not need the additional modes.Combitips advanced and ViscoTipThe dispenser works on the positive displacement principle and automatically recognises the attached Combitip advanced. There are 9 sizes from 0.1 to 50 mL in 4 purity grades. Depending on the tip, the increments are between 0.1 µL and 50 µL. A ViscoTip is included for viscous liquids. The E3 is operated with a colour display, 8 speed settings and 9 display languages. A motion sensor switches the device off when it is not in use.Typical applicationsDistributing reagents evenly into tubes or platesAliquoting buffers and media in long seriesDispensing viscous solutions using the ViscoTipBattery and power supplyThe lithium-ion battery (3.7 V, 1,200 mAh) charges in approx. 2 hours. According to Eppendorf, one charge lasts for approx. 5 hours. This means at least 500 aspirations and 10,000 dispensing steps (test conditions: Combitip advanced 10 mL, speed 5, 20 steps per aspiration, 500 µL per step). The power supply accepts 100 to 240 V and delivers 5 V at 1 A. Software updates can be installed via Micro-USB. A charging station is not part of the scope of delivery; the bundle with charger stand 2 has the No. 4987000371.Technical detailsFeatureValueSeriesEppendorf Multipette E3/E3x, electronicTypeHand dispenser, positive displacement principleModes3 (dispensing, automatic dispensing, pipetting)Dispensing volume1 µL to 50 mL, depending on the Combitip advanced (9 sizes from 0.1 to 50 mL)Increments0.1 µL to 50 µL, depending on the tipDispensing steps per fillingup to 100BatteryLithium-ion, 3.7 V, 1,200 mAhCharging timeapprox. 2 hoursOperating timeapprox. 5 hours according to EppendorfPower supply100 to 240 V, 50/60 Hz, output 5 V / 1 A / 5 WInterfaceMicro-USB for software updatesDispenser weightapprox. 190 gLength221 mmAutoclavablenoUV resistance254 nmStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number4987000010Measurement deviationsFor each of the 9 Combitip sizes, Eppendorf specifies 4 test volumes. According to Eppendorf, the values apply only with original Combitips advanced. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The table shows the smallest and the largest test volume for each Combitip. The systematic error describes how far the mean value deviates from the set volume, the random error the scatter of the individual values.Combitip advancedTest volumeSystematic errorRandom error0.1 mL1 µL±11 %±14 %100 µL±1 %±0.5 %0.2 mL2 µL±4 %±5.5 %200 µL±1 %±0.5 %0.5 mL5 µL±3 %±6 %500 µL±0.9 %±0.3 %1 mL10 µL±3.5 %±7 %1 mL±0.6 %±0.2 %2.5 mL25 µL±2 %±3.5 %2.5 mL±0.5 %±0.15 %5 mL50 µL±2.5 %±6 %5 mL±0.5 %±0.15 %10 mL100 µL±1.5 %±3.5 %10 mL±0.4 %±0.15 %25 mL250 µL±2.5 %±3 %25 mL±0.3 %±0.15 %50 mL500 µL±2 %±3 %50 mL±0.3 %±0.15 %Scope of deliveryMulti-dispenser with rechargeable batteryPower supply with plug adaptersOperating instructionsQuick guideCombitips advanced in an assortment pack (1 tip per size)ViscoTipAccessories and procurementAlso available are charger stand 2 for E3 and E3x and pipette holders without charging function from Eppendorf. The procurement service arranges further Combitips advanced in all sizes on request.
Brand Transferpette S Single-Channel Pipette, variable, 10-100 µl, DE-M, 705874
When transferring supernatants during protein purification, the volume varies from fraction to fraction, depending on how much supernatant actually has to be removed after centrifugation. The Brand Transferpette S variable D-100 covers 10-100 µl with an increment of 0.1 µl and can be adjusted by dial without tools.Continuously adjustable with 0.1 µl incrementThe Transferpette S variable 10-100 µl (model D-100) covers the volume range 10-100 µl in steps of 0.1 µl. The volume is set with a dial without tools, and a lockable position (UNLOCK/LOCK) prevents accidental adjustment during serial work. To match the volume range, Brand recommends the pipette tip size 2-200 µl. In total, the variable Transferpette S series comprises ten volume sizes from 0.1 µl to 10 ml, so a suitable model from the same range can be combined for almost every working range. One range smaller is the Transferpette S variable 5-50 µl (D-50, MPN 705873). One range larger follows the Transferpette S variable 20-200 µl (D-200, MPN 705878).Accuracy according to DIN EN ISO 8655Tested according to DIN EN ISO 8655 at three volume levels: at the full nominal volume, the pipette achieves an accuracy A of up to ±0.6 % and a coefficient of variation CV of up to 0.2 %, at half the nominal volume ±0.8 % and 0.4 % respectively, and at the lower end, at one tenth of the nominal volume, ±3 % and 1 % respectively. The three test points show that the accuracy decreases towards the lower end of the volume range, an effect that occurs with every piston-operated pipette and should be taken into account when choosing the suitable model. In addition, the pipette bears the DE-M marking under German weights and measures law. The accuracy A describes the deviation of the average dispensed volume from the target value, and the coefficient of variation CV the scatter of several repetitions at this volume.Tool-free adjustment with Easy CalibrationIf the factory setting deviates, the pipette can be adjusted directly using the Easy Calibration function, without any additional tool. An adjustment slider under the label window with volume offset shows when the factory setting has been changed. A red adjustment slider in the display window shows whether the pipette is still running on its original calibration or has been readjusted.Fully autoclavableThe pipette withstands autoclaving as a complete unit, at 121 °C and 2 bar, with a holding time of at least 15 minutes according to DIN EN 285, in the assembled state, and dismantling before sterilisation is not necessary.Variable or fixed: which design fitsWhen transferring supernatants, the amount actually available is never exactly the same, which suits the variable Transferpette S D-100. If, on the other hand, the same volume always has to be transferred in a standardised protocol, a Transferpette S Fix from the same range is sufficient. For the D-100 with its range of 10-100 µl, the specific working step therefore decides whether variable or fixed is the more suitable design.Quality certificate and warranty includedA quality certificate (Performance Certificate) is enclosed, which can be filed directly into your own quality assurance. The single-channel pipettes of the Transferpette S series are covered by a three-year warranty.Typical applicationsTransferring supernatants in protein purification with a fluctuating volumeELISA and other microtitre plate applications with variable requirementsDilution series in general laboratory routineInitial laboratory equipment for newly set up workstationsQuality assurance with documented, variable volume settingTechnical detailsModelTransferpette S variable, D-100Volume range10-100 µlIncrement0.1 µlRecommended tip size2-200 µlAccuracy (A) at 100/50/10 % of nominal volume≤ ±0.6 % / ±0.8 % / ±3 %Coefficient of variation (CV) at 100/50/10 % of nominal volume≤ 0.2 % / 0.4 % / 1 %OperationOne-handed operation, volume lock UNLOCK/LOCKAdjustmentEasy Calibration, tool-free, adjustment slider under label windowSterilisationFully autoclavable at 121 °C, 2 bar, at least 15 minutes according to DIN EN 285MarkingDE-MScope of delivery1x Transferpette S variable 10-100 µl (D-100)1x quality certificate1x silicone greaseIndividual requirements & procurement serviceIf the volume range does not match the complete requirement, it is worth looking at the neighbouring Transferpette S models or at the starter kits with several volume ranges in one set. For suitable pipette tips, spare parts, individual calibration or larger quantities for several workstations, our procurement service can help.
Eppendorf Xplorer Multichannel Pipette, 8-channel, 50–1,200 µL, green, 4861000163
A multichannel pipette fills as many wells in one operation as it has channels. The Eppendorf Xplorer 8-channel pipette for 50 to 1,200 µL has 8 channels and a fixed tip cone spacing of 9 mm. This fits 96-well plates. A motor moves the pistons of all channels simultaneously.Fixed tip cone spacing for 96-well platesThe tip cone spacing is the distance between the centres of adjacent tip cones. For this pipette it is 9 mm and cannot be adjusted. The tips therefore sit in the grid of the plate, and each channel carries its own tip. According to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. Matching tips: epT.I.P.S. 50 to 1,250 µL, colour code green.Anyone who switches between plate formats with different grids needs a pipette with adjustable tip cone spacing. For this, Eppendorf offers the Xplorer plus Move It.Typical applicationsLoading 96-well plates with samples, reagents or mediaPreparing dilution series across a plateTransferring samples between plates with the same gridFilling rows or columns without pipetting individuallyRepeated plate work in which a manual multichannel pipette causes fatigueOperationControl is via the colour display and multifunction rocker. The rocker follows the principle ‘up is up, down is down’. The motor does the pipetting itself, and the hand only triggers it. The pipette has five pipetting modes (Pip, Dis, Ads, P/M and Man) and eight speed settings. Volumes are set with a step size of 1 µL. The display is available in nine languages. Adjustment is possible according to liquid type, altitude and extended tips, with 1, 2 or 3 points.Battery, power supply and autoclavingThe lithium-polymer battery (3.7 V, 750 mAh) takes approx. 3 hours to charge. According to the data sheet, one charge lasts for up to 8 hours of use. Work can continue while the pipette is on the power supply. The lower part can be autoclaved at 121 °C and 1 bar for 20 minutes, the upper part cannot. The pipette is UV-resistant at 254 nm. The power supply takes 100 to 240 V ±10 % at 50 to 60 Hz and delivers 5 V at 1 A. Mains plug adaptors of types A, C, G and I are included. Software updates can be installed via Micro-USB. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.Technical detailsFeatureValueSeriesEppendorf Xplorer, electronicChannels8Volume range50 to 1,200 µLStep size1 µLTip cone spacing9 mm, fixedPlate grid96-well platesColour codegreenMatching tipepT.I.P.S. 50 to 1,250 µLPipetting modes5Speed settings8DisplayColour display, 9 languagesBatteryLithium-polymer, 3.7 V, 750 mAh, charging time approx. 3 hoursPower supply100 to 240 V ±10 %, 50 to 60 Hz, with mains plug adaptorsAutoclavableLower part, 121 °C, 1 bar, 20 minutesOperating conditions+5 °C to +40 °C, 10 to 95 % relative humidityStorage-5 °C to +45 °CStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number4861000163Measurement deviationsFor this pipette, Eppendorf specifies 4 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.Test volumeSystematic errorRandom error50 µL±8 % / ±4 µL±1.2 % / ±0.6 µL120 µL±6 % / ±7.2 µL±0.9 % / ±1.08 µL600 µL±2.7 % / ±16.2 µL±0.4 % / ±2.4 µL1,200 µL±1.2 % / ±14.4 µL±0.3 % / ±3.6 µLScope of deliveryPipettePower supply with mains plug adaptorsOperating instructionsQuick guideCertificatePipette greaseDepending on the model, further parts are included, for example locking rings for deactivating the spring loading, an O-ring tool or an unlocking tool. Pipette tips are not included in the scope of delivery.Accessories and procurementThe Charger 2 charger stand and the Charger Carousel 2 charging carousel are also available. Both charge the pipette via charging contacts. The procurement service helps with tips and other Eppendorf accessories on request.
Eppendorf Research plus single-channel pipette, fixed, 1,000 µL, blue, 3124000121
A fixed-volume pipette has only one value, and that is exactly what its usefulness is based on: the Eppendorf Research plus for 1,000 µL always dispenses this volume. It cannot be adjusted and therefore cannot be changed by accident. The pipette is mechanical, works with an air cushion and is fully autoclavable. The colour code blue indicates the matching tip, namely epT.I.P.S. 50 to 1,000 µL.When a fixed volume makes senseA fixed value is worthwhile for work steps that never change: the same addition to every preparation, the same amount of buffer in every vessel. Anyone who switches between several volumes is more flexible with an adjustable-volume pipette. Anyone who performs the same step every day saves the setting with the fixed-volume pipette.Colour code and tipsAccording to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. For this pipette, the tip epT.I.P.S. 50 to 1,000 µL belongs to the colour code blue. Some nominal volumes are available in two colours, which belong to different tips. Colour code and tip should therefore be compared before ordering. The pipette is an open system, and tips from other manufacturers are possible. However, the measurement deviations apply only with original epT.I.P.S.Spring-loaded cone and adjustmentThe tip cone is spring-loaded. A locking ring supplied with the pipette deactivates the spring loading. The pipette can be adjusted temporarily. 5 adjustment seals and an adjustment tool (hex key) are supplied for this purpose. It is possible to return to the factory adjustment without calibration.Typical applicationsAlways the same addition of 1,000 µL to many vesselsStandard and control solutions with a fixed preparation volumeReaction mixtures in which a reagent is always added in the same amountRoutine protocols in which the volume is specifiedWorkstations where several fixed-volume pipettes stand side by side in the standAutoclaving and resistanceThe entire pipette may go into the autoclave at 121 °C and 1 bar for 20 minutes. Disinfectants and decontamination agents are wiped off beforehand. The pipette is UV-resistant at 254 nm. According to Eppendorf, chemical resistance is high, and special lower parts are available for aggressive chemicals. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.Technical detailsFeatureValueSeriesEppendorf Research plus, mechanicalTypeSingle-channel pipette, fixed volumeVolume1,000 µLColour codeblueMatching tipepT.I.P.S. 50 to 1,000 µLTip conespring-loaded, locking ring for deactivating the spring loading includedAutoclavablefully, 121 °C, 1 bar, 20 minutesUV resistance254 nmOperating conditions+5 °C to +40 °C, 10 to 95 % relative humidityStorage-5 °C to +45 °CStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number3124000121Measurement deviationsEppendorf specifies the measurement deviation for the nominal volume of this pipette. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.Test volumeSystematic errorRandom error1,000 µL±0.6 % / ±6 µL±0.2 % / ±2 µLScope of deliveryPipetteOperating instructionsCertificateAdjustment tool (hex key)5 adjustment seals for temporary adjustmentPipette greaseLocking ring for deactivating the spring loadingPipette tips are not included in the scope of delivery.Accessories and procurementepT.I.P.S. and pipette holders from Eppendorf are also available. The procurement service takes care of the suitable version on request.
Eppendorf Reference 2 multichannel pipette, 8-channel, 0.5–10 µL, medium grey, 4926000018
The Eppendorf Reference 2 8-channel pipette for 0.5 to 10 µL is a mechanical multichannel pipette with one-button operation. According to the Eppendorf data sheet, the 8- and 12-channel models are intended for 96-well plates. One stroke serves 8 positions. The volume is set in steps of 0.01 µL, and the colour code medium grey belongs to the tip epT.I.P.S. 0.1 to 20 µL.One-button operation with 8 channelsAccording to Eppendorf, volume selection, pipetting and tip ejection are carried out with a single control element. The display has four digits, a magnifier window makes reading easier, and a volume lock holds the set value. According to Eppendorf, haptic feedback is intended to prevent unintentional tip ejection. The data sheet mentions active aerosol reduction.Tips and tip coneMatching tips are epT.I.P.S. 0.1 to 20 µL, recognisable by the colour code medium grey. According to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. The spring-loaded tip cone of the multichannel pipette can be switched on and off. The pipette is an open system, and tips from other manufacturers are possible. The measurement deviations apply only with original epT.I.P.S.Typical applicationsLoading 96-well plates with samples, reagents or mediaSerial dilutions across several plate columnsTransferring samples from plate to plateAssay preparations with many identical wellsSeries with several plates per dayAdjustmentThe scope of delivery includes 1 adjustment seal for temporary adjustment and 2 adjustment seals for factory adjustment. Temporary adjustment allows adaptation to the liquid, to extended tips or to the altitude without calibrating. It is possible to return to the factory adjustment.Autoclaving and resistanceThe pipette may go into the autoclave in the assembled state at 121 °C and 1 bar for 20 minutes, upper and lower part together. No additional disinfectants or sodium hypochlorite are used. The pipette is UV-resistant at 254 nm. According to Eppendorf, chemical resistance is high, and special lower parts are available for aggressive chemicals. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.Technical detailsFeatureValueSeriesEppendorf Reference 2, mechanicalTypeMultichannel pipette, adjustable volumeChannels8Volume range0.5 to 10 µLStep size0.01 µLPlate format96-well plates according to the Eppendorf data sheetOperationOne-button operationDisplayfour-digit, with magnifier window and volume lockColour codemedium greyMatching tipepT.I.P.S. 0.1 to 20 µLTip conespring-loaded, can be switched on and offAutoclavablefully, 121 °C, 1 bar, 20 minutesUV resistance254 nmOperating conditions+5 °C to +40 °C, 10 to 95 % relative humidityStorage-5 °C to +45 °CStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number4926000018Measurement deviationsFor this pipette, Eppendorf specifies 4 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.Test volumeSystematic errorRandom error0.5 µL±12 % / ±0.06 µL±8 % / ±0.04 µL1 µL±8 % / ±0.08 µL±5 % / ±0.05 µL5 µL±4 % / ±0.2 µL±2 % / ±0.1 µL10 µL±2 % / ±0.2 µL±1 % / ±0.1 µLScope of deliveryPipetteOperating instructionsCertificate1 adjustment seal for temporary adjustment2 adjustment seals for factory adjustmentPipette greaseDepending on the model, an O-ring tool is also included. Pipette tips are not included in the scope of delivery.Accessories and procurementPipette Carousel 2 and Pipette Stand 2 from Eppendorf are also available. Tips for plate work are procured by the procurement service on request.
Eppendorf Research plus single-channel pipette, variable, 1–10 mL, turquoise, 3123000080
The Eppendorf Research plus for 1 to 10 mL is a mechanical single-channel pipette with adjustable volume. The volume is selected in steps of 0.01 mL and read on the four-digit volume display. The colour code turquoise belongs to the matching tip, namely epT.I.P.S. 0.5 to 10 mL.Setting the volumeVolume selection, pipetting and tip ejection are handled by separate controls. The pipette works with an air cushion. The smallest adjustable step is 0.01 mL. Anyone who pipettes preparations in many different volumes manages with an adjustable-volume pipette and does not need a set of fixed-volume pipettes.Tips and colour codeAccording to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. Here, this is the colour code turquoise for epT.I.P.S. 0.5 to 10 mL. The colour code depends on the tip and not on the pipette volume. The pipette is an open system, and tips from other manufacturers are possible. However, the measurement deviations apply only with original epT.I.P.S.AdjustingThe pipette can be adjusted temporarily. 5 adjustment seals and an adjustment tool (hex key) are supplied for this purpose. Returning to the factory adjustment is possible without calibration.Typical applicationsTransferring reagents and samples into reaction vesselsPreparing dilution series with changing volumesAliquoting liquids in the range 1 to 10 mLMixing solutions by repeated aspiration and dispensingMethods in which the volume changes from preparation to preparationWhen choosing, it helps to look at the volume that occurs most often in daily work. If it is close to the nominal volume, the relative measurement deviation is smaller, as the table below shows.Autoclaving and resistanceThe entire pipette may go into the autoclave at 121 °C and 1 bar for 20 minutes. Disinfectants and decontamination agents are wiped off beforehand. Filter sleeve and protective filter, where present on the model, are autoclaved separately. The pipette is UV-resistant at 254 nm. According to Eppendorf, chemical resistance is high, and special lower parts are available for aggressive chemicals. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.Technical detailsFeatureValueSeriesEppendorf Research plus, mechanicalTypeSingle-channel pipette, adjustable volumeVolume range1 to 10 mLStep size0.01 mLDisplayfour-digit volume displayColour codeturquoiseMatching tipepT.I.P.S. 0.5 to 10 mLAutoclavablefully, 121 °C, 1 bar, 20 minutesUV resistance254 nmOperating conditions+5 °C to +40 °C, 10 to 95 % relative humidityStorage-5 °C to +45 °CStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number3123000080Measurement deviationsFor this pipette, Eppendorf specifies 3 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.Test volumeSystematic errorRandom error1,000 µL±3 % / ±30 µL±0.6 % / ±6 µL5,000 µL±0.8 % / ±40 µL±0.2 % / ±10 µL10,000 µL±0.6 % / ±60 µL±0.15 % / ±15 µLScope of deliveryPipetteOperating instructionsCertificateAdjustment tool (hex key)5 adjustment seals for temporary adjustmentPipette greaseDepending on the model, further parts are included, for example an epT.I.P.S. Box 2.0 or a sample bag with epT.I.P.S., a locking ring for deactivating the spring loading, protective filters and a pipette wrench.Accessories and procurementThe Pipette Carousel 2 and the Pipette Stand 2 from Eppendorf are also available. Further epT.I.P.S. and accessories are procured by the procurement service on request.
Eppendorf Research plus Move It multichannel pipette, 6-channel, 120–1,200 µL, adjustable cone spacing, dark green, 3125000192
Tubes are spaced closer together or further apart than the wells of a plate, and anyone who handles both otherwise needs two pipettes. With the Eppendorf Research plus Move It 6-channel pipette for 120 to 1,200 µL, the tip cone spacing can be adjusted by hand, in the range 9 to 20 mm. It is mechanical and fully autoclavable.Adjusting the tip cone spacingThe tip cone spacing is the distance between the centres of adjacent tip cones. An adjustment knob sets it. The format stop allows quick changes between source and target format, depending on the model for example microtitre plates, tubes or agarose gels. The pipette head can be rotated through 360°. The system works without tubing: according to Eppendorf, there are no tubing connections between the cone and the piston-cylinder system.Tips and colour codeMatching tips are epT.I.P.S. 50 to 1,250 µL L, recognisable by the colour code dark green. According to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. The pipette is an open system, and tips from other manufacturers are possible. The measurement deviations apply only with original epT.I.P.S. This model does not have a spring-loaded tip cone.Volume and adjustmentThe volume is set mechanically in steps of 1 µL. The pipette can be adjusted temporarily; 5 adjustment seals and an adjustment tool are supplied for this purpose. It is possible to return to the factory adjustment without calibration.Typical applicationsTransferring samples from tubes into platesPipetting between different plate formats without changing the pipetteLoading gel chambers, provided the model covers the tip cone spacing of the chamberDistributing reagents from reservoirs to rows of vessels with a different spacingLaboratories that do not want to buy a separate multichannel pipette for every formatAutoclaving and resistanceThe entire pipette may go into the autoclave at 121 °C and 1 bar for 20 minutes. Disinfectants and decontamination agents are wiped off beforehand. It is UV-resistant at 254 nm, and according to Eppendorf the chemical resistance is high. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.Technical detailsFeatureValueSeriesEppendorf Research plus Move It, mechanicalTypeMultichannel pipette, adjustable volumeChannels6Volume range120 to 1,200 µLStep size1 µLTip cone spacing9 to 20 mm, manually adjustableColour codedark greenMatching tipepT.I.P.S. 50 to 1,250 µL LTip conenot spring-loadedPipette headrotatable through 360°, without tubingAutoclavablefully, 121 °C, 1 bar, 20 minutesUV resistance254 nmOperating conditions+5 °C to +40 °C, 10 to 95 % relative humidityStorage-5 °C to +45 °CStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number3125000192Measurement deviationsFor this pipette, Eppendorf specifies 3 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.Test volumeSystematic errorRandom error120 µL±6 % / ±7.2 µL±1.3 % / ±1.6 µL600 µL±2.7 % / ±16.2 µL±0.4 % / ±2.4 µL1,200 µL±1.2 % / ±14.4 µL±0.3 % / ±3.6 µLScope of deliveryPipetteOperating instructionsCertificateAdjustment tool5 adjustment seals for temporary adjustmentO-ring toolDepending on the model, an epT.I.P.S. Box 2.0 and an unlocking tool are also included.Accessories and procurementPipette Carousel 2 and Pipette Stand 2 from Eppendorf are also available. Anyone looking for tips for the required formats receives a quotation via the procurement service on request.
Eppendorf Pipette Carousel 2, holder for 6 pipettes, 3116000015
Six pipettes within reach and rotatable on the spot: the Eppendorf Pipette Carousel 2 has a carrying handle, a stainless steel base plate and six holders that fit Eppendorf pipettes. The carousel has no charging function. Electronic devices such as the Xplorer or Multipette E3 are not charged here.Holders for six pipette typesThe scope of delivery includes 6 holders for Research, Research plus, Reference, Reference 2, Biomaster and epMotion Tip Tools. Holders for Xplorer, Multipette E3 and Multipette M4 are available separately. The holders can be inserted on either side and changed without tools. This allows the carousel to be fitted with pipettes of different series. ColorTag marking rings fit.Stability and cleaningSilicone rubber feet hold the carousel on the table, the base plate is made of stainless steel 1.4301. Holders, handle and outer surfaces are made of ASA/PC. The carousel is not autoclavable and is cleaned damp with a mild detergent. For decontamination, Eppendorf specifies UV irradiation at 254 nm (30 W, 60 cm distance, discolouration possible) or fumigation with hydrogen peroxide up to 500 ppm for 3 hours.Typical applicationsStoring mechanical pipettes for multiple volume ranges at the workstationGrouping pipettes from different series in a single standAssign pipettes to individuals or projects using a ColorTag ringCarry the carousel between workstationsTechnical detailsFeatureValueTypeRotating pipette stand, without charging functionPositionsup to 6 pipettes or dispensersHolders supplied6, for Research, Research plus, Reference, Reference 2, Biomaster and epMotion Tip ToolsHoldersusable on both sides, interchangeable without toolsMaterialBase plate: stainless steel 1.4301; holder, handle and outer surfaces: ASA/PC; rubber feet: siliconeCharging functionnoAutoclavablenoCleaningdamp, with mild detergentUV irradiation254 nm, 30 W, distance 60 cm, discolouration possibleFumigationHydrogen peroxide up to 500 ppm, 3 hoursMarkingCompatible with ColorTag marking ringsManufacturerEppendorfManufacturer number3116000015Scope of deliveryPipette Carousel 26 pipette holders (for Research, Research plus, Reference, Reference 2, Biomaster and epMotion Tip Tools)Carrying handleAccessories and procurementHolders for Xplorer, Multipette E3 and Multipette M4 are also available. Anyone who wants to charge electronic pipettes needs a charger stand or charger carousel from Eppendorf, which are listed as separate items. The procurement service arranges holders and further Eppendorf accessories on request.
Eppendorf Multipette E3x Hand Dispenser with Charging Stand, Electronic, 4987000380
Seven modes and a fixed charging place: this bundle combines the Eppendorf Multipette E3x with charger stand 2. With Combitips advanced, the electronic hand dispenser dispenses 1 µL to 50 mL; the modes include serial dilutions, aspiration and titration.E3x modesIn addition to dispensing (Dis), automatic dispensing (Ads) and pipetting (Pip), the E3x has Sequential Dispensing (Seq), aspiration (Asp), Aspirate and Dispense (A/D) and titration (Ttr). Serial dilutions, supernatants and titrations can thus be handled on the same device. If Dis, Ads and Pip are enough, the E3 with charger stand (manufacturer number 4987000371) is the alternative.Stand, power supply and batteryCharger stand 2 charges the dispenser at the workstation. One power supply with plug adapters powers the dispenser and the stand. The lithium-ion battery (3.7 V, 1,200 mAh) charges in approx. 2 hours. According to Eppendorf, one charge lasts for approx. 5 hours. For this, Eppendorf states at least 500 aspirations and 10,000 dispensing steps (test conditions: Combitip advanced 10 mL, speed 5, 20 steps per aspiration, 500 µL per step). The weight of approx. 190 g applies to the dispenser without the stand.Typical applicationsPreparing serial dilutions in Seq mode directly at the workstationRemoving supernatants in Asp modePerforming titrations in Ttr modeDispensing reagents and buffers in seriesPut the dispenser back in the charger stand after each seriesCombitips advancedThe dispenser automatically recognises attached Combitips advanced. There are 9 sizes ranging from 0.1 to 50 mL in 4 purity grades. Up to 100 dispensing steps per filling are possible; a ViscoTip for viscous liquids is included. The colour display offers 9 languages and 8 speed settings.Technical detailsFeatureValueSeriesEppendorf Multipette E3/E3x, electronicTypeHand dispenser, positive displacement principleModes7 (Dis, Ads, Pip, Seq, Asp, A/D, Ttr)Dispensing volume1 µL to 50 mL, depending on the Combitip advanced (9 sizes from 0.1 to 50 mL)Increments0.1 µL to 50 µL, depending on the tipDispensing steps per fillingup to 100BatteryLithium-ion, 3.7 V, 1,200 mAhCharging timeapprox. 2 hoursOperating timeapprox. 5 hours according to EppendorfPower supply100 to 240 V, 50/60 Hz, output 5 V / 1 A / 5 WInterfaceMicro-USB for software updatesDispenser weightapprox. 190 gLength221 mmAutoclavablenoUV resistance254 nmStandardConformity with ISO 8655 according to EppendorfManufacturerEppendorfManufacturer number4987000380Measurement deviationsFor each of the 9 Combitip sizes, Eppendorf specifies 4 test volumes. According to Eppendorf, the values apply only with original Combitips advanced. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The table shows the smallest and the largest test volume for each Combitip. The systematic error describes how far the mean value deviates from the set volume, the random error the scatter of the individual values.Combitip advancedTest volumeSystematic errorRandom error0.1 mL1 µL±11 %±14 %100 µL±1 %±0.5 %0.2 mL2 µL±4 %±5.5 %200 µL±1 %±0.5 %0.5 mL5 µL±3 %±6 %500 µL±0.9 %±0.3 %1 mL10 µL±3.5 %±7 %1 mL±0.6 %±0.2 %2.5 mL25 µL±2 %±3.5 %2.5 mL±0.5 %±0.15 %5 mL50 µL±2.5 %±6 %5 mL±0.5 %±0.15 %10 mL100 µL±1.5 %±3.5 %10 mL±0.4 %±0.15 %25 mL250 µL±2.5 %±3 %25 mL±0.3 %±0.15 %50 mL500 µL±2 %±3 %50 mL±0.3 %±0.15 %Scope of deliveryMulti-dispenser with rechargeable batteryCharger stand 2Power supply with plug adapters for dispenser and charger standOperating instructionsQuick guideCombitips advanced in an assortment pack (1 tip per size)ViscoTipAccessories and procurementPipette holders without charging function from Eppendorf are also available. The procurement service arranges Combitips advanced in further quantities on request.
Pipette, dispenser or burette: which instrument for which task
Under pipettes you will find single-channel and multichannel pipettes from 0.1 µl to 10 ml, mechanical and electronic, from Eppendorf (Research plus, Reference 2, Xplorer, Multipette), Brand (Transferpette, Transferpettor) and IKA (PETTE, IKA PEN), plus pipette tips, stands and the PLT unit leak tester.
If you dispense the same amount of reagent from a stock bottle again and again, a bottle-top dispenser is the right tool; see bottle-mounted dispensers. The Brand Dispensette S covers 0.1 to 100 ml as Digital, Analog or Fix, with or without recirculation valve, and as Organic for concentrated hydrochloric and nitric acid. For buffers and culture media the seripettor is sufficient.
Titrations run straight from the GL45 bottle with a bottle-top burette, without a stand; see bottle-mounted burettes. The Brand Titrette shows the volume used digitally, comes in 10, 25 and 50 ml and, if required, with an RS232 interface for the titration record.
Frequently asked questions
Mechanical or electronic pipette?
For long series and fixed protocols an electronic pipette is the more comfortable choice. The IKA PEN in 0.5 to 10, 5 to 100 and 10 to 200 µl has a display, five pipetting modes (pipette, reverse pipetting, multi dispensing, dilute, manual measurement), Bluetooth with a free app and a lithium battery charged via USB-C. Eppendorf Xplorer and Brand Transferpette electronic go up into the millilitre range.
When do I need a multichannel pipette?
As soon as you fill microplates regularly. Twelve channels cover a row of a 96-well plate in one stroke, eight channels a column. Eppendorf offers 4 to 24 channels, Move It with adjustable tip spacing for transfers from tubes into the plate, Brand and IKA 8 and 12 channels.
Air displacement or positive displacement?
For aqueous solutions an air-displacement pipette is sufficient. Viscous, foaming or volatile media distort the volume there, so for these there are positive-displacement pipettes with the piston inside the tip: the Brand Transferpettor and the Eppendorf Multipette with Combitips. The IKA PEN has a reverse mode for more viscous liquids.
What does the recirculation valve on a bottle-top dispenser do?
Excess liquid runs back into the stock bottle without you opening the discharge tube or the bottle. That saves reagent, especially when it is expensive or hazardous. Hydrochloric acid above 20 % and nitric acid above 30 % belong in the yellow Dispensette S Organic.
Which pipette tips fit?
The IKA Tip 10 µl fits the IKA PEN 0.5 to 10 µl, the IKA Tip 200 µl fits the PEN 5 to 100 and 10 to 200 µl, both also fit the PETTE and come in bags, boxes or sterile with filter. For the Transferpette S 20 to 200 µl, Brand recommends 2 to 200 µl tips.