Brand Transferpette -8 electronic Multichannel Pipette, 8-Channel, 0.5-10 µl, European Power Supply, DE-M, 705399
€723.00
- 8-channel multichannel pipette, electronic, volume range 0.5-10 µl
- Operating modes: PIP, PIPmix, revPIP, GEL, DISP
- NiMH battery, 3x AAA, 3.6 V, 700 mAh, European power supply included in the scope of delivery
- Only the pipette shaft is autoclavable, 121 °C, 2 bar, reference run afterwards
- Easy Calibration digital via menu control
- Matching tip: 0.5-20 µl
- DE-M marking under German measurement and verification law
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Brand Transferpette -8 electronic Multichannel Pipette, 8-Channel, 0.5-10 µl, European Power Supply, DE-M, 705399"
In molecular biology, a single small addition often decides the quality of an entire preparation. The Transferpette -8 electronic with 8 channels in the 0.5-10 µl range dispenses such minimal volumes column by column, electronically controlled in PIP mode.
Operating modes for multichannel applications
The benefit of the operating modes shows above all when switching between mixing and dispensing: PIPmix takes care of mixing a batch, and PIP of the subsequent dispensing, without changing the device.
Battery in multichannel operation
The built-in NiMH battery, made up of three cylindrical AAA single cells (3.6 V, 700 mAh), drives all channels together and, when fully charged, lasts for a long pipetting day. Charging is done via a power supply for Europe with an input voltage of 100 to 240 V at 50/60 Hz and an output voltage of 6.5 V DC, 200 mA, which is included in the scope of delivery for this version. A replacement battery during a running series is not provided for in this series. Charging takes place via the power supply unit between two work steps.
Digital adjustment
Easy Calibration is carried out digitally via the menu control and is possible in every mode except GEL. An adjustment in PIP mode is automatically transferred to PIPmix and revPIP, whereas an adjustment in DISP mode applies exclusively to DISP and is not transferred when the mode is changed. With 8 channels, an adjustment made once affects all channels equally, and readjusting individual channels is not provided for.
Autoclave reprocessing
Unlike the mechanical Transferpette S -8, the electronic version is not autoclaved as a complete device. Only the unscrewable pipette shaft is autoclaved, 121 °C, 2 bar, at least 15 minutes according to DIN EN 285. After autoclaving, a joint reference run on the handle section is required on all 8 channels before pipetting again.
Selection guide
Anyone dosing beyond 10 µl will find the next larger range of the same series in the neighbouring variant 1-20 µl (MPN 705400). Number of channels, operating modes and adjustment procedure remain identical when changing between the volume steps of the same series. Only the test range, tip size and order number change.
Typical applications
- Dispensing qPCR master mix and enzyme additions column by column
- smallest reagent quantities in parallel across eight wells in PIP mode
- reproducible series preparations in the lowest microlitre range
Accuracy across the test range
Testing is carried out at three test volumes (100 %, 50 % and 10 % of the nominal volume). The systematic error is at 10 µl: ± 1.2 % / 5 µl: ± 2.0 % / 1 µl: ± 8.0 %, and the random error (coefficient of variation) at 10 µl: ± 0.8 % / 5 µl: ± 1.5 % / 1 µl: ± 4.0 %. Across 8 channels, the same tolerance applies to each individual channel. As with any air cushion pipette, the relative deviation increases towards the lower test point and is tightest at the upper test point close to the nominal volume.
Place within the Transferpette electronic family
In addition to the 8-channel version, there is the electronic multichannel pipette Transferpette -12 electronic with 12 channels in the same model system, and the electronic single-channel series Transferpette electronic is available for individual samples. Operating modes, adjustment procedure, battery and power supply are uniform across the whole electronic series, so laboratories with several channel numbers do not have to get used to different operating logic. Anyone who also wants to pipette mechanically will find the same number of channels in the Transferpette S -8 series.
Technical details
| Feature | Value |
| Number of channels | 8 |
| Version | electronic, multichannel |
| Volume range | 0.5-10 µl |
| Pipette tip | 0.5-20 µl |
| Systematic error (100/50/10 %) | 10 µl: ± 1.2 % / 5 µl: ± 2.0 % / 1 µl: ± 8.0 % |
| Random error CV (100/50/10 %) | 10 µl: ± 0.8 % / 5 µl: ± 1.5 % / 1 µl: ± 4.0 % |
| Operating modes | PIP, PIPmix, revPIP, GEL, DISP |
| Autoclavability | pipette shaft only, 121 °C, 2 bar, min. 15 min according to DIN EN 285, reference run afterwards |
| Battery | NiMH, 3x AAA, 3.6 V, 700 mAh |
| Power supply | 6.5 V DC, 200 mA, input 100-240 V/50-60 Hz, included in the scope of delivery |
| Adjustment | Easy Calibration digital via menu control, in every mode except GEL |
| DE-M marking | under German measurement and verification law |
| Manufacturer part no. (MPN) | 705399 |
Scope of delivery
- Transferpette -8 electronic, volume range 0.5-10 µl, MPN 705399
- Quality certificate
- Battery (fitted at the factory)
- Power supply for Europe
- Silicone grease
Pipette tips are not included in the scope of delivery and are available separately.
Procurement and service
Accessories such as pipette tips, replacement batteries, power supplies or calibration services are put together on request by our procurement service. Details on our service page.
| Number of channels: | 8-channel |
|---|---|
| Operation: | electronic |
| Volume range: | 0.5 µl - 10 µl |
| Volume setting: | variable |