Brand Transferpette -8 electronic Multichannel Pipette, 8-Channel, 1-20 µl, European Power Supply, DE-M, 705400
€723.00
- 8-channel multichannel pipette, electronic, volume range 1-20 µl
- Operating modes: PIP, PIPmix, revPIP, GEL, DISP
- NiMH battery, 3x AAA, 3.6 V, 700 mAh, European power supply included in the scope of delivery
- Only the pipette shaft is autoclavable, 121 °C, 2 bar, reference run afterwards
- Easy Calibration digital via menu control
- Matching tip: 0.5-20 µl
- DE-M marking under German measurement and verification law
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Brand Transferpette -8 electronic Multichannel Pipette, 8-Channel, 1-20 µl, European Power Supply, DE-M, 705400"
Dilution series in the lower two-digit microlitre range call for consistent dosing over many repetitions. The Transferpette -8 electronic with 1-20 µl does this column by column across eight channels.
Battery in multichannel operation
Three cylindrical AAA single cells (3.6 V, 700 mAh, NiMH) form the built-in battery, which drives all channels together and, when fully charged, lasts a whole pipetting day. Charging is done via a power supply for Europe with an input voltage of 100 to 240 V at 50/60 Hz and an output voltage of 6.5 V DC, 200 mA, which is included in the scope of delivery for this version. A replacement battery during a running series is not provided for in this series. Charging takes place via the power supply unit between two work steps.
Operating modes for multichannel applications
With frequent changes of medium within the same series, revPIP helps to dispense highly viscous or foaming reagents column by column without bubble formation.
Autoclave reprocessing
With the electronic version, unlike the mechanical Transferpette S -8, only the unscrewable pipette shaft is autoclaved, 121 °C, 2 bar, at least 15 minutes according to DIN EN 285. After that, a reference run on the handle section is required for all 8 channels together before operation continues.
Digital adjustment
The pipette can be adjusted digitally via the menu control, and Easy Calibration works in all modes except GEL. An adjustment made in PIP mode automatically also applies to PIPmix and revPIP, whereas a DISP adjustment remains limited to DISP. With 8 channels, an adjustment made once affects all channels equally, and readjusting individual channels is not provided for.
Typical applications
- Dilution series column by column across eight channels
- Portioning DNA and RNA samples in parallel
- Adding reagents column by column in microtitre plates
Selection guide
The neighbouring variant 0.5-10 µl (MPN 705399) lies below, and the 5-100 µl version (MPN 705403) lies above. Number of channels, operating modes and adjustment procedure remain identical when changing between the volume steps of the same series. Only the test range, tip size and order number change.
Place within the Transferpette electronic family
In addition to the 8-channel version, there is the electronic multichannel pipette Transferpette -12 electronic with 12 channels in the same model system, and the electronic single-channel series Transferpette electronic is available for individual samples. Operating modes, adjustment procedure, battery and power supply are uniform across the whole electronic series, so laboratories with several channel numbers do not have to get used to different operating logic. Anyone who also wants to pipette mechanically will find the same number of channels in the Transferpette S -8 series.
Accuracy across the test range
Testing is carried out at three test volumes (100 %, 50 % and 10 % of the nominal volume). The systematic error is at 20 µl: ± 1.0 % / 10 µl: ± 2.0 % / 2 µl: ± 8.0 %, and the random error (coefficient of variation) at 20 µl: ± 0.5 % / 10 µl: ± 1.0 % / 2 µl: ± 3.0 %. Each of the 8 channels is subject to the same tolerance. As with any air cushion pipette, the relative deviation increases towards the lower test point and is tightest at the upper test point.
Technical details
| Feature | Value |
| Number of channels | 8 |
| Version | electronic, multichannel |
| Volume range | 1-20 µl |
| Pipette tip | 0.5-20 µl |
| Systematic error (100/50/10 %) | 20 µl: ± 1.0 % / 10 µl: ± 2.0 % / 2 µl: ± 8.0 % |
| Random error CV (100/50/10 %) | 20 µl: ± 0.5 % / 10 µl: ± 1.0 % / 2 µl: ± 3.0 % |
| Operating modes | PIP, PIPmix, revPIP, GEL, DISP |
| Autoclavability | pipette shaft only, 121 °C, 2 bar, min. 15 min according to DIN EN 285, reference run afterwards |
| Battery | NiMH, 3x AAA, 3.6 V, 700 mAh |
| Power supply | 6.5 V DC, 200 mA, input 100-240 V/50-60 Hz, included in the scope of delivery |
| Adjustment | Easy Calibration digital via menu control, in every mode except GEL |
| DE-M marking | under German measurement and verification law |
| Manufacturer part no. (MPN) | 705400 |
Scope of delivery
- Transferpette -8 electronic, volume range 1-20 µl, MPN 705400
- Quality certificate
- Battery (fitted at the factory)
- Power supply for Europe
- Silicone grease
Pipette tips are not included in the scope of delivery and are available separately.
Procurement and service
Accessories such as pipette tips, replacement batteries, power supplies or calibration services are put together on request by our procurement service. Details on our service page.
| Number of channels: | 8-channel |
|---|---|
| Operation: | electronic |
| Volume range: | 1 µl - 20 µl |
| Volume setting: | variable |