Brand Transferpette S Single-Channel Pipette, variable, 0.5-10 µl, DE-M, 705870
€273.25
- Variable volume range 0.5-10 µl (D-10)
- Increment 0.01 µl
- Accuracy A ≤ ±1 % at nominal volume
- DE-M marking, tested according to DIN EN ISO 8655
- Lockable volume setting (UNLOCK/LOCK)
- Fully autoclavable at 121 °C according to DIN EN 285
- Incl. quality certificate and silicone grease
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Brand Transferpette S Single-Channel Pipette, variable, 0.5-10 µl, DE-M, 705870"
When putting together a PCR master mix, the volumes of the individual components, from primer to polymerase, change within the same reaction. The Brand Transferpette S variable D-10 covers 0.5-10 µl with an increment of 0.01 µl and can be set by dial without tools to the volume required.
Continuously adjustable with 0.01 µl increment
The Transferpette S variable 0.5-10 µl (model D-10) covers the volume range 0.5-10 µl in steps of 0.01 µl. The volume is set with a dial without tools, and a lockable position (UNLOCK/LOCK) prevents accidental adjustment during serial work. To match the volume range, Brand recommends the pipette tip size 0.5-20 µl. In total, the variable Transferpette S series comprises ten volume sizes from 0.1 µl to 10 ml, so a suitable model from the same range can be combined for almost every working range. One range smaller is the Transferpette S variable 0.1-2.5 µl (D-2.5, MPN 705869). One range larger follows the Transferpette S variable 2-20 µl (D-20, MPN 705872).
Accuracy according to DIN EN ISO 8655
The accuracy is documented according to DIN EN ISO 8655 at three test points, at the full, half and one tenth of the nominal volume. At the full nominal volume, the accuracy A is up to ±1 %, at half up to ±1.6 % and at one tenth up to ±7 %. The coefficient of variation CV is correspondingly up to 0.5 %, 1 % and 4 %. The three test points show that the accuracy decreases towards the lower end of the volume range, an effect that occurs with every piston-operated pipette and should be taken into account when choosing the suitable model. In addition, the pipette bears the DE-M marking under German weights and measures law. The accuracy A describes the deviation of the average dispensed volume from the target value, and the coefficient of variation CV the scatter of several repetitions at this volume.
Tool-free adjustment with Easy Calibration
The Easy Calibration function allows readjustment directly on the pipette, without tools, using an adjustment slider under the label window with volume offset. A changed factory setting becomes visible through a red adjustment slider in the display window.
Fully autoclavable
For sterile applications, the pipette can be autoclaved fully assembled, as a complete unit, at 121 °C and 2 bar, with a holding time of at least 15 minutes according to DIN EN 285, and dismantling is not required.
Variable or fixed: which design fits
A master mix consists of several components with different volumes, and the variable Transferpette S D-10 is built for this. If, on the other hand, only a single master mix component is added in large numbers always in the same amount, a Transferpette S Fix from the same range is the faster solution. For the D-10 with its range of 0.5-10 µl, the specific working step therefore decides whether variable or fixed is the more suitable design.
Quality certificate and warranty included
Every pipette is supplied with a quality certificate (Performance Certificate), which can be filed into your own quality assurance. A three-year warranty applies to the single-channel pipettes of the Transferpette S series.
Typical applications
- Putting together PCR master mix components with changing volume
- Dilution series when optimising a qPCR reaction mix with slightly changing volume
- Adding reagents in ELISA diagnostics with a variable small volume
- Sample preparation for sequencing
- Workstations with changing staff and different volume requirements
Technical details
| Model | Transferpette S variable, D-10 |
| Volume range | 0.5-10 µl |
| Increment | 0.01 µl |
| Recommended tip size | 0.5-20 µl |
| Accuracy (A) at 100/50/10 % of nominal volume | ≤ ±1 % / ±1.6 % / ±7 % |
| Coefficient of variation (CV) at 100/50/10 % of nominal volume | ≤ 0.5 % / 1 % / 4 % |
| Operation | One-handed operation, volume lock UNLOCK/LOCK |
| Adjustment | Easy Calibration, tool-free, adjustment slider under label window |
| Sterilisation | Fully autoclavable at 121 °C, 2 bar, at least 15 minutes according to DIN EN 285 |
| Marking | DE-M |
Scope of delivery
- 1x Transferpette S variable 0.5-10 µl (D-10)
- 1x quality certificate
- 1x silicone grease
Individual requirements & procurement service
If the volume range does not match the complete requirement, it is worth looking at the neighbouring Transferpette S models or at the starter kits with several volume ranges in one set. For suitable pipette tips, spare parts, individual calibration or larger quantities for several workstations, our procurement service can help.
| Number of channels: | 1-channel |
|---|---|
| Operation: | mechanical |
| Volume range: | 0.5 µl - 10 µl |
| Volume setting: | variable |