Brand Transferpettor Positive Displacement Pipette, Digital, 20-100 µl, with Glass Capillary, 701822
€324.00
- Positive displacement pipette, piston in direct contact with the liquid
- Volume range 20-100 µl, increment 0.1 µl
- Accuracy A 1.5 %, coefficient of variation CV 0.4 %
- Colour code blue
- Glass capillary, suitable for viscous and foaming media
- Usable at vapour pressure up to 500 mbar, density up to 3.8 g/cm³
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Brand Transferpettor Positive Displacement Pipette, Digital, 20-100 µl, with Glass Capillary, 701822"
Serum samples and vegetable oils are among the media at which an air cushion pipette is most likely to reach its limits, because both liquids are more viscous than water. The Brand Transferpettor positive displacement pipette, Digital 20-100 µl, instead transmits the movement directly via the piston in the glass capillary. In clinical chemistry, this makes it suitable for transferring serum samples in the range from 20 to 100 µl without residues remaining in the capillary.
Positive displacement principle in the micro version
The micro version of the Transferpettor Digital guides the liquid through a glass capillary, and the piston moves directly in this component. According to Brand, this design covers media with a density of up to 3.8 g/cm³ at a vapour pressure of up to 500 mbar, as found in alcohols, ethers and hydrocarbons. The working temperature range is 15 to 40 °C. How viscous the sample may be depends on the set nominal volume. According to the manufacturer, the permitted kinematic viscosity rises with larger volume from 6,000 up to 140,000 mm²/s.
The 20-100 µl version is identified by the colour code blue and works with an increment of 0.1 µl, with an accuracy of 1.5 % and a coefficient of variation of 0.4 %.
Typical applications
The following applications, among others, are typical for the 20-100 µl version:
- Transferring serum samples in clinical chemistry
- Pipetting solvents and reagents with high vapour pressure, where an air cushion pipette tends towards evaporation errors
- Working with foaming or highly viscous media such as sera and vegetable oils, where an air cushion pipette traps air bubbles
- Repeated pipetting steps, as positive displacement leaves hardly any residue in the capillary
Selection guide within the Digital series
With 20-100 µl, this version covers the upper end of the micro group and borders on the macro models from 100 µl with PP cap. Like the three smaller Digital micro models, it is listed without the DE-M marking. Anyone who regularly needs exactly 50 or 100 µl will find the same design with a fixed volume in the Fix series, without an adjustment option there but with the same positive displacement principle.
Distinction from the Transferpette S
The Brand Transferpette S works on the air displacement principle, with an air cushion between piston and liquid transmitting the movement. For aqueous standard solutions, this is the usual choice. The Transferpettor Digital dispenses with this air cushion and is therefore suitable for media where an air cushion would lead to volume errors, for example with viscous or foaming liquids. The two series complement each other but do not replace each other.
Maintenance and accessories
The accessory range for the micro version with glass capillary includes station, glass capillaries, seals and a combi pack of caps and seal. For replacing the piston rod and seal, Brand expressly recommends the repair kit, complemented by clamping ring and slip-on block.
The same accessory range applies to the 20-100 µl version with colour code blue as to the other micro models of the Digital series.
Frequently asked questions
Which medium does the 20-100 µl version tolerate?
According to the manufacturer, media with a density of up to 3.8 g/cm³ and a vapour pressure of up to 500 mbar, at a working temperature of 15 to 40 °C.
How accurate is the pipette?
The accuracy is 1.5 % and the coefficient of variation 0.4 %, in each case according to the manufacturer's test value for the 20-100 µl version with colour code blue.
Is the 20-100 µl version marked DE-M?
No, the manufacturer's page shows no DE-M marking for the micro versions of the Digital series.
What is the 20-100 µl version typically suitable for?
For transferring serum samples in clinical chemistry, and in general for sera and vegetable oils and other viscous or foaming media in the corresponding volume range.
Technical details
| Series | Transferpettor Digital |
| Design | micro (glass capillary) |
| Volume | 20-100 µl |
| Increment | 0.1 µl |
| Accuracy A | 1.5 % |
| Coefficient of variation CV | 0.4 % |
| Colour code | blue |
| Max. vapour pressure | 500 mbar |
| Max. density | 3.8 g/cm³ |
| Working temperature | 15 to 40 °C |
Scope of delivery
- Transferpettor positive displacement pipette
Individual requirements and procurement service
If a further volume range, matching accessories or a spare part from the Transferpettor Digital series is needed in addition to the 20-100 µl version, our procurement service can help.
| Number of channels: | 1-channel |
|---|---|
| Operation: | mechanical |
| Volume range: | 20 µl - 100 µl |
| Volume setting: | variable |