Skip to main content Skip to search Skip to main navigation

Brand Transferpettor Positive Displacement Pipette, Fixed, 50 µl, with Glass Capillary, 701868

ⓘ  This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.

Product information "Brand Transferpettor Positive Displacement Pipette, Fixed, 50 µl, with Glass Capillary, 701868"

In many laboratory routines, serum samples are always transferred in the same volume; a fixed volume reduces the risk of accidental misadjustment compared with a variable pipette. The Brand Transferpettor positive displacement pipette, fixed at 50 µl, delivers this consistent volume. Direct piston contact within the glass capillary keeps residual wetting low, even with the slightly higher viscosity of serum.

Direct displacement principle without an air cushion

The 50 µl fixed-volume version utilises the same glass capillary technology as the micro models in the Digital range. According to Brand, the series is designed for media with a density of up to 3.8 g/cm³ and a vapour pressure of up to 500 mbar; the operating temperature range is 15 to 40 °C. For the nominal volume of 50 µl, Brand specifies a kinematic viscosity limit of up to 100,000 mm²/s (nominal volume 50 µl). There is no incremental step value in the Fix series, as no volume adjustment is provided.

The colour code for this 50 µl version is green; the accuracy is 1.8 % and the coefficient of variation is 0.4 %.

Typical applications

Typical applications for the 50 µl version include the following:

  • Transferring serum samples in consistent volumes
  • Working with solvents with high vapour pressure, such as alcohols or ethers, without the evaporation errors associated with an air-cushion pipette
  • Working with foaming or highly viscous media such as sera, where an air-cushion pipette traps air bubbles

Selection guide for the Fix range

At 50 µl, the manufacturer specifies a permissible kinematic viscosity of up to 100,000 mm²/s, which is significantly higher than for the smaller Fix models. As with the entire Fix range, the design features a glass capillary. For variable volumes within the same range, the Digital version (20-100 µl) is a suitable complement.

Fix or Digital

If the volume remains constant throughout the entire workflow, the simpler, more economical Fix version is preferable, as is the case here with the 50 µl model. If the volume varies from batch to batch, for example, in dilution series, a Digital version from the same product range is the more suitable choice, as it can be adjusted to a new value without having to change the instrument.

Maintenance and accessories

For the fixed-volume range, we offer the same range of accessories as for the ‘micro’ version of the Digital range: station, glass capillaries, seals, ‘Caps+Seal’ combo pack, repair kit, micro piston rod, clamping ring and attachment block. The repair kit covers the replacement of the piston rod and seal.

For the 50 µl version with the green colour code, this range of accessories remains unchanged, regardless of the specific fixed volume.

Frequently Asked Questions

Can the volume of the 50 µl version be adjusted?
No, the Fix series has a fixed volume without an adjustment wheel; due to its design, adjustment is not provided for.

How accurate is this volume setting?
The accuracy is 1.8 %, with a coefficient of variation of 0.4 %, according to the manufacturer’s test data for the 50 µl version with a green colour code.

Which media are compatible with the Fix series?
Media with a density of up to 3.8 g/cm³ and a vapour pressure of up to 500 mbar, at an operating temperature of 15 to 40 °C, according to the manufacturer’s specifications for the entire glass capillary range.

Which accessories are compatible with the 50 µl version?
The same range as for the ‘micro’ version of the Digital series: station, glass capillaries, seals, Caps+Seal combo pack, repair kit, micro piston rod, clamping ring and attachment block.

What is the 50 µl version typically used for?
For transferring serum samples in consistent quantities.

Technical details

LineTransferpettor Fix
DesignGlass capillary
Volume50 µl (fixed volume)
Accuracy R1.8 %
Coefficient of variation CV0.4 %
Colour codegreen
Max. vapour pressure500 mbar
Max. density3.8 g/cm³
Operating temperature15 to 40 °C
Max. kinematic viscosity100,000 mm²/s (nominal volume 50 µl)

Scope of delivery

  • Transferpettor positive displacement pipette, 50 µl

Individual requirements and procurement service

For further volume ranges from the Transferpettor-Fix series, suitable accessories or spare parts, we provide support via our own procurement service.

Number of channels: 1-channel
Operation: mechanical
Volume range: 50 µl (fixed)
Volume setting: fixed