Eppendorf Reference 2 multichannel pipette, 8-channel, 0.5–10 µL, medium grey, 4926000018
- Mechanical 8-channel pipette, 0.5 to 10 µL, step size 0.01 µL
- According to the Eppendorf data sheet, for 96-well plates
- One-button operation, four-digit display with magnifier window and volume lock
- Colour code medium grey for epT.I.P.S. 0.1 to 20 µL
- Tip cone spring-loaded, can be switched on and off
- Fully autoclavable at 121 °C, UV-resistant at 254 nm
- Conforms to ISO 8655 according to Eppendorf, 4 test volumes with measurement deviation specified
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Eppendorf Reference 2 multichannel pipette, 8-channel, 0.5–10 µL, medium grey, 4926000018"
The Eppendorf Reference 2 8-channel pipette for 0.5 to 10 µL is a mechanical multichannel pipette with one-button operation. According to the Eppendorf data sheet, the 8- and 12-channel models are intended for 96-well plates. One stroke serves 8 positions. The volume is set in steps of 0.01 µL, and the colour code medium grey belongs to the tip epT.I.P.S. 0.1 to 20 µL.
One-button operation with 8 channels
According to Eppendorf, volume selection, pipetting and tip ejection are carried out with a single control element. The display has four digits, a magnifier window makes reading easier, and a volume lock holds the set value. According to Eppendorf, haptic feedback is intended to prevent unintentional tip ejection. The data sheet mentions active aerosol reduction.
Tips and tip cone
Matching tips are epT.I.P.S. 0.1 to 20 µL, recognisable by the colour code medium grey. According to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. The spring-loaded tip cone of the multichannel pipette can be switched on and off. The pipette is an open system, and tips from other manufacturers are possible. The measurement deviations apply only with original epT.I.P.S.
Typical applications
- Loading 96-well plates with samples, reagents or media
- Serial dilutions across several plate columns
- Transferring samples from plate to plate
- Assay preparations with many identical wells
- Series with several plates per day
Adjustment
The scope of delivery includes 1 adjustment seal for temporary adjustment and 2 adjustment seals for factory adjustment. Temporary adjustment allows adaptation to the liquid, to extended tips or to the altitude without calibrating. It is possible to return to the factory adjustment.
Autoclaving and resistance
The pipette may go into the autoclave in the assembled state at 121 °C and 1 bar for 20 minutes, upper and lower part together. No additional disinfectants or sodium hypochlorite are used. The pipette is UV-resistant at 254 nm. According to Eppendorf, chemical resistance is high, and special lower parts are available for aggressive chemicals. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.
Technical details
| Feature | Value |
|---|---|
| Series | Eppendorf Reference 2, mechanical |
| Type | Multichannel pipette, adjustable volume |
| Channels | 8 |
| Volume range | 0.5 to 10 µL |
| Step size | 0.01 µL |
| Plate format | 96-well plates according to the Eppendorf data sheet |
| Operation | One-button operation |
| Display | four-digit, with magnifier window and volume lock |
| Colour code | medium grey |
| Matching tip | epT.I.P.S. 0.1 to 20 µL |
| Tip cone | spring-loaded, can be switched on and off |
| Autoclavable | fully, 121 °C, 1 bar, 20 minutes |
| UV resistance | 254 nm |
| Operating conditions | +5 °C to +40 °C, 10 to 95 % relative humidity |
| Storage | -5 °C to +45 °C |
| Standard | Conformity with ISO 8655 according to Eppendorf |
| Manufacturer | Eppendorf |
| Manufacturer number | 4926000018 |
Measurement deviations
For this pipette, Eppendorf specifies 4 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.
| Test volume | Systematic error | Random error |
|---|---|---|
| 0.5 µL | ±12 % / ±0.06 µL | ±8 % / ±0.04 µL |
| 1 µL | ±8 % / ±0.08 µL | ±5 % / ±0.05 µL |
| 5 µL | ±4 % / ±0.2 µL | ±2 % / ±0.1 µL |
| 10 µL | ±2 % / ±0.2 µL | ±1 % / ±0.1 µL |
Scope of delivery
- Pipette
- Operating instructions
- Certificate
- 1 adjustment seal for temporary adjustment
- 2 adjustment seals for factory adjustment
- Pipette grease
Depending on the model, an O-ring tool is also included. Pipette tips are not included in the scope of delivery.
Accessories and procurement
Pipette Carousel 2 and Pipette Stand 2 from Eppendorf are also available. Tips for plate work are procured by the procurement service on request.
| Colour: | Grey |
|---|---|
| Number of channels: | 8-channel |
| Operation: | mechanical |
| Volume range: | 0.5 µl - 10 µl |
| Volume setting: | variable |