Eppendorf Reference 2 single-channel pipette, variable, 2–20 µL, light grey, 4924000037
- Mechanical single-channel pipette, 2 to 20 µL, step size 0.02 µL
- One-button operation, four-digit display with magnifier window and volume lock
- Colour code light grey for epT.I.P.S. 0.5 to 20 µL L
- Fully autoclavable at 121 °C, UV-resistant at 254 nm
- Adjustment seals for temporary adjustment and factory adjustment included in the scope of delivery
- Conforms to ISO 8655 according to Eppendorf, 3 test volumes with measurement deviation specified
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Eppendorf Reference 2 single-channel pipette, variable, 2–20 µL, light grey, 4924000037"
A magnifier window above the four-digit display makes the set volume easy to read, and a volume lock holds it in place. The Eppendorf Reference 2 for 2 to 20 µL is a mechanical single-channel pipette with one-button operation. The volume is set in steps of 0.02 µL, and the colour code light grey belongs to the tip epT.I.P.S. 0.5 to 20 µL L.
One button for everything
According to Eppendorf, volume selection, pipetting and tip ejection are carried out with a single control element. According to Eppendorf, haptic feedback is intended to prevent unintentional tip ejection. The data sheet also mentions active aerosol reduction. The surface of the pipette is smooth, and the pipette works with an air cushion.
Tips and colour code
According to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. Here, the colour code light grey applies for epT.I.P.S. 0.5 to 20 µL L. The colour code depends on the tip and not on the pipette volume. The pipette is an open system, and tips from other manufacturers are possible. The measurement deviations apply only with original epT.I.P.S.
Adjustment
The scope of delivery includes 1 adjustment seal for temporary adjustment and 2 adjustment seals for factory adjustment. Temporary adjustment allows adaptation to the liquid, to extended tips or to the altitude without calibrating. It is possible to return to the factory adjustment.
Typical applications
- Transferring samples and reagents in the range 2 to 20 µL into vessels
- Dilution series with frequently changing volumes
- Aliquoting from stock solutions
- Work in which the set volume is to remain unchanged for longer periods
- Long pipetting series with a single control element
Autoclaving and resistance
The pipette may go into the autoclave in the assembled state at 121 °C and 1 bar for 20 minutes, upper and lower part together. No additional disinfectants or sodium hypochlorite are used. Filter sleeve and protective filter, where present on the model, are autoclaved separately. The pipette is UV-resistant at 254 nm. According to Eppendorf, chemical resistance is high, and special lower parts are available for aggressive chemicals. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.
Technical details
| Feature | Value |
|---|---|
| Series | Eppendorf Reference 2, mechanical |
| Type | Single-channel pipette, adjustable volume |
| Volume range | 2 to 20 µL |
| Step size | 0.02 µL |
| Operation | One-button operation |
| Display | four-digit, with magnifier window and volume lock |
| Colour code | light grey |
| Matching tip | epT.I.P.S. 0.5 to 20 µL L |
| Autoclavable | fully, 121 °C, 1 bar, 20 minutes |
| UV resistance | 254 nm |
| Operating conditions | +5 °C to +40 °C, 10 to 95 % relative humidity |
| Storage | -5 °C to +45 °C |
| Standard | Conformity with ISO 8655 according to Eppendorf |
| Manufacturer | Eppendorf |
| Manufacturer number | 4924000037 |
Measurement deviations
For this pipette, Eppendorf specifies 3 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.
| Test volume | Systematic error | Random error |
|---|---|---|
| 2 µL | ±3 % / ±0.06 µL | ±1.5 % / ±0.03 µL |
| 10 µL | ±1 % / ±0.1 µL | ±0.6 % / ±0.06 µL |
| 20 µL | ±0.8 % / ±0.16 µL | ±0.3 % / ±0.06 µL |
Scope of delivery
- Pipette
- Operating instructions
- Certificate
- 1 adjustment seal for temporary adjustment
- 2 adjustment seals for factory adjustment
- Pipette grease
Depending on the model, further parts are included, for example an epT.I.P.S. Box 2.0 or a sample bag with epT.I.P.S., a locking ring for deactivating the spring loading, a filter sleeve with filter inserts and a pipette wrench.
Accessories and procurement
The Pipette Carousel 2 and the Pipette Stand 2 from Eppendorf are also available. Further epT.I.P.S. are procured by the procurement service on request.
| Colour: | Grey |
|---|---|
| Number of channels: | 1-channel |
| Operation: | mechanical |
| Volume range: | 2 µl - 20 µl |
| Volume setting: | variable |