Eppendorf Research plus multichannel pipette, 12-channel, 10–100 µL, yellow, 3125000044
€869.00
% Manufacturer's RRP: €879.00 1% below manufacturer's RRP
- Mechanical 12-channel pipette, 10 to 100 µL, step size 0.1 µL
- Fixed tip cone spacing 9 mm for 96-well plates
- Colour code yellow for epT.I.P.S. 2 to 200 µL
- Four-digit volume display, air cushion
- Fully autoclavable at 121 °C, UV-resistant at 254 nm
- Conforms to ISO 8655 according to Eppendorf, 3 test volumes with measurement deviation specified
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Eppendorf Research plus multichannel pipette, 12-channel, 10–100 µL, yellow, 3125000044"
With a microtitre plate, the spacing of the wells determines the choice of pipette. The Eppendorf Research plus 12-channel pipette for 10 to 100 µL has a fixed tip cone spacing of 9 mm and therefore fits 96-well plates. One stroke serves 12 positions. The pipette is mechanical, works with an air cushion and is fully autoclavable.
Fixed grid
The tip cone spacing is the distance between the centres of adjacent tip cones. For this pipette it cannot be adjusted. Anyone who has to transfer between tubes and plate or between different plate formats will find a variant with adjustable tip cone spacing in the Research plus Move It.
Tips and colour code
Matching tips are epT.I.P.S. 2 to 200 µL. According to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S., and here the colour code yellow applies. The pipette is an open system, and tips from other manufacturers are possible. The measurement deviations apply only with original epT.I.P.S.
Volume and operation
The volume is set mechanically in steps of 0.1 µL and read on the four-digit volume display. Volume selection, pipetting and tip ejection are handled by separate controls. Whether the tip cone is spring-loaded depends on the model.
Typical applications
- Loading 96-well plates with samples, reagents or media
- Serial dilutions across several plate columns
- Transferring samples from plate to plate when both plates have the same grid
- Assay preparations in which every column is treated identically
- Serial screening with many plates, in which a single-channel pipette would be too slow
Adjustment and autoclaving
The pipette can be adjusted temporarily. 5 adjustment seals and an adjustment tool (hex key) are supplied for this purpose. It is possible to return to the factory adjustment without calibration. The entire pipette may go into the autoclave at 121 °C and 1 bar for 20 minutes. Disinfectants and decontamination agents are wiped off beforehand. It is UV-resistant at 254 nm, and according to Eppendorf the chemical resistance is high. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.
Technical details
| Feature | Value |
|---|---|
| Series | Eppendorf Research plus, mechanical |
| Type | Multichannel pipette, adjustable volume |
| Channels | 12 |
| Volume range | 10 to 100 µL |
| Step size | 0.1 µL |
| Display | four-digit volume display |
| Tip cone spacing | 9 mm, fixed |
| Plate grid | 96-well plates |
| Colour code | yellow |
| Matching tip | epT.I.P.S. 2 to 200 µL |
| Autoclavable | fully, 121 °C, 1 bar, 20 minutes |
| UV resistance | 254 nm |
| Operating conditions | +5 °C to +40 °C, 10 to 95 % relative humidity |
| Storage | -5 °C to +45 °C |
| Standard | Conformity with ISO 8655 according to Eppendorf |
| Manufacturer | Eppendorf |
| Manufacturer number | 3125000044 |
Measurement deviations
For this pipette, Eppendorf specifies 3 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.
| Test volume | Systematic error | Random error |
|---|---|---|
| 10 µL | ±3 % / ±0.3 µL | ±2 % / ±0.2 µL |
| 50 µL | ±1 % / ±0.5 µL | ±0.8 % / ±0.4 µL |
| 100 µL | ±0.8 % / ±0.8 µL | ±0.3 % / ±0.3 µL |
Scope of delivery
- Pipette
- Operating instructions
- Certificate
- Adjustment tool (hex key)
- 5 adjustment seals for temporary adjustment
- Pipette grease
Depending on the model, further parts are included, for example an epT.I.P.S. Box 2.0, locking rings for deactivating the spring loading, an O-ring tool or an unlocking tool.
Accessories and procurement
Pipette Carousel 2 and Pipette Stand 2 from Eppendorf are also available. Tips for the suitable plate format and further accessories are procured by the procurement service on request.
| Colour: | Yellow |
|---|---|
| Number of channels: | 12-channel |
| Operation: | mechanical |
| Volume range: | 10 µl - 100 µl |
| Volume setting: | variable |