Anyone who repeatedly pipettes the same volume does not need a variable setting, but rather a reliable preset that cannot be accidentally adjusted. The yellow Eppendorf Research plus 200 µL is designed precisely for this purpose: a fixed volume of 200 µL, a spring-loaded tip cone for effortless tip attachment, and a low weight within the Eppendorf pipette range. The pipette is suitable for routine procedures where the same volume is dispensed over many repetitions. A typical example is the washing step in ELISA diagnostics, where the same volume of wash buffer is added to each well, often several times in succession across an entire plate.

Typical applications

The Eppendorf Research plus 200 µL is suitable, amongst other things, for:

  • ELISA washing steps, where the same volume of wash buffer is dispensed into each well
  • Standard procedures in molecular biology
  • Dilution series and reagent dispensing in routine laboratories
  • Sample aliquoting into reaction vessels

Features and handling

All Research-plus pipettes up to 1 mL are fitted with a spring-loaded tip cone, which reduces the force required when changing tips. The pipette is one of the lightest in the Eppendorf range, which makes a noticeable difference to user comfort during long pipetting runs. The lower section, featuring a Fortron PerfectPiston piston, can be quickly dismantled without tools for maintenance and cleaning.

Eppendorf provides a user adjustment feature for the Research-plus range, known as secondary adjustment, which allows the pipette to be set for a liquid other than water without permanently altering the factory setting.

Selection guide within the Research-plus range

Within the fixed-preset Research-plus models, there are several volumes to choose from. The following overview shows adjacent fixed-volume versions from the same range, each with its own colour code and manufacturer’s number:

VolumeColour codeMPN
200 µLblue3124000091
50 µLyellow3124000067
20 µLyellow3124000040
500 µLblue3124000113

The appropriate volume for each individual case depends on the actual sample quantities and reagent volumes involved in the respective step. Selecting a volume that is too large reduces relative accuracy at the lower end of the scale, whilst selecting a volume that is too small necessitates several pipetting steps instead of a single one.

This model belongs to the yellow tip family (2 to 200 µL), which also includes the fixed-volume models 20 µL, 25 µL, 50 µL and 100 µL, as well as the variable-volume models 2–20 µL, 10–100 µL and 20–200 µL.

A comparison of Research plus, Reference 2 and Xplorer

Research plus, Reference 2 and Xplorer together form the Eppendorf manual pipette family, but differ significantly in terms of operation. Research plus adjusts the volume mechanically via a setting wheel, without any electronics at all. Reference 2, on the other hand, uses a digital display with one-button operation and is particularly suitable for workstations where volumes change frequently. Xplorer and Xplorer plus feature electronic, programmable pipetting, are battery-operated and, in the Plus version, offer additional functions such as dilution or sequential dispensing. Research plus, on the other hand, stands out as the lightest of the three ranges and the easiest to handle during continuous use.

Differentiation within the Research plus range

If this pipette’s volume range does not fully meet your requirements, it is worth looking at neighbouring Research plus models, for example the Eppendorf Research plus G pipette, single-channel, fixed, 200 µL, blue, 3124000091 Eppendorf Research plus G pipette, single-channel, fixed, 50 µL, yellow, 3124000067. This allows you to put together a suitable combination of several volume ranges without having to switch to a different product line.

Use, storage and maintenance

121 °C, 1 bar overpressure, 20 minutes: the pipette can be autoclaved whilst fully assembled; the lower section does not need to be dismantled for this, only the filter sleeve and protective filter are placed separately in the autoclave. There is no need to re-lubricate the pistons afterwards, although a gravimetric check is still advisable. Without transport packaging, the recommended storage conditions are between –5 and 45 degrees Celsius and 10 to 95 per cent relative humidity; during operation, the conditions are 5 to 40 degrees Celsius within the same humidity range. The relevant Eppendorf authorised partner is the point of contact for warranty matters, excluding wear parts and damage resulting from misuse or the unauthorised opening of the upper part.

Fixed volume or variable setting

Fixed-volume pipettes are ideal for work steps that always require the same volume, for example, routine dispensing in diagnostics or standardised sample preparation. As there is no adjustment wheel, there is no need to check the set value before each use, which saves time and prevents operating errors caused by accidental turning. For workstations with varying volume requirements, the Research-plus range offers suitable variable models. During the ELISA washing step, the volume remains constant across the entire plate and throughout multiple wash cycles; a fixed preset makes this repetitive step quicker and less prone to errors than readjusting before each cycle.

Frequently Asked Questions

Is the Eppendorf Research plus 200 µL autoclavable?
Yes. The upper and lower parts can be autoclaved together at 121 degrees Celsius and 1 bar overpressure for 20 minutes without the lower part needing to be dismantled. The filter sleeve and protective filter are autoclaved separately.

Is re-lubrication necessary after autoclaving?
No, according to the manufacturer, there is no need to re-grease the pistons after autoclaving. However, a gravimetric check of accuracy afterwards is recommended.

Can the volume of the 200 µL version be adjusted?
No, this version has a fixed, preset volume of 200 µL and no adjustment wheel for selecting the volume. If you require different volumes within the same range, you will find suitable variable models in the Research plus range.

Which pipette tips are compatible with the Eppendorf Research plus 200 µL?
According to the operating instructions: epT.I.P.S. yellow 53 mm (2–200 µL).

Is the pipette an in vitro diagnostic?
According to the operating instructions, the Research-plus range is designed for the low-contamination transfer of liquids, including samples from the human body and reagents within the context of an in vitro diagnostic application as defined by Directive 98/79/EC.

To whom should warranty claims be addressed?
To the relevant Eppendorf authorised dealer. Excluded from the warranty are damages resulting from misuse, unauthorised opening of the upper section, and wear and tear of typical wear parts.

Can the pipette be readjusted if it deviates from the factory setting?
According to the manufacturer, secondary calibration is provided for the Research-plus range. Details are set out in a separate Eppendorf calibration document, the full text of which was not available at the time of writing.

What does the IVD marking on the Research-plus range signify?
The user manual generically refers to the pipette as an in vitro diagnostic device within the meaning of Directive 98/79/EC, for the entire Research-plus range. No product-specific confirmation was available at the time of writing.

Technical details

RangeEppendorf Research plus
Modelfix
Volume200 µL
Colour codeyellow
Compatible pipette tipepT.I.P.S. yellow 53 mm (2–200 µL)
Test volume 200 µLSystematic measurement error 0.6% / 1.2 µLRandom measurement error 0.2% / 0.4 µL
StandardTested in accordance with ISO 8655

Contents

  • 1 Eppendorf Research plus single-channel pipette (200 µL, yellow)

Individual requirements & procurement service

For suitable pipette tips, spare parts or additional volume ranges from the Research plus range, LT Laborhandel provides support via its own procurement service at lt-laborhandel.de/service.

Colour: Yellow
Number of channels: 1-channel
Operation: mechanical
Volume range: 200 µl (fixed)
Volume setting: fixed