Eppendorf Research plus single-channel pipette, variable, 1–10 mL, turquoise, 3123000080
€279.00
Available, delivery time: 1-3 days
- Variable volume range 1–10 mL
- Increment 0.01 mL
- Colour code: turquoise
- Spring-loaded tip cone, requires minimal operating force
- Autoclavable at 121 °C for 20 minutes
- epT.I.P.S. turquoise 165 mm (1–10 mL)
Product information "Eppendorf Research plus single-channel pipette, variable, 1–10 mL, turquoise, 3123000080"
Varying sample volumes within the same volume range require a pipette that can be adjusted quickly and without the need for tools. The Eppendorf Research plus single-channel pipette, in its variable 1–10 mL turquoise version, meets precisely this need, with 0.01 mL increments and a spring-loaded tip cone that reduces the effort required to attach tips. It is designed for workstations where dilution series or different sample volumes are used in the same batch.
Typical applications
The Eppendorf Research plus 1–10 mL is suitable, amongst other things, for:
- Preparing larger volumes of buffers and media
- Dilution of stock solutions
- Filling test tubes and culture flasks
- Decanting during sample preparation in routine laboratories
Features and handling
For volumes up to 1 mL, Eppendorf’s Research-plus range features a spring-loaded tip cone, which makes attaching and ejecting the pipette tip noticeably easier. The low weight of the Research-plus range is particularly noticeable in terms of ease of use during extensive pipetting runs. The lower section, featuring a Fortron PerfectPiston, can be quickly dismantled without tools for maintenance and cleaning.
Eppendorf provides a user adjustment feature for the Research-plus range, known as secondary adjustment, which allows the pipette to be set for a liquid other than water without permanently altering the factory setting.
Selection guide within the Research-plus range
The volume ranges vary significantly across the variable Research-plus models. The following overview shows neighbouring variable models from the same range:
| Volume | Colour code | MPN |
| 2–20 µL | light grey | 3123000098 |
| 2–20 µL | yellow | 3123000039 |
| 30–300 µL | orange | 3123000101 |
| 100–1000 µL | blue | 3123000063 |
The appropriate volume in each individual case depends on the actual sample quantities and reagent volumes involved in the respective step. Selecting a volume that is too large reduces relative accuracy at the lower end of the scale, whilst selecting a volume that is too small necessitates several pipetting steps instead of a single one.
Comparing Research plus, Reference 2 and Xplorer
Anyone choosing between the three Eppendorf manual pipette ranges should first consider the operation. The Research plus is adjusted via a mechanical adjustment wheel, with no electronics and no display, making it robust and low-maintenance. The Reference 2 replaces the adjustment wheel with a single-button operation featuring a digital display, which is practical for laboratories with frequently changing volumes and multiple users sharing the same instrument. The Xplorer and Xplorer Plus go one step further, pipetting electronically programmed sequences, including password protection on the Plus model. For a clearly defined volume range in routine work, the mechanical Research Plus range remains the simplest choice.
Differentiation within the Research plus range
If the volume range of this pipette does not fully meet your requirements, it is worth looking at neighbouring Research plus models, for example the Eppendorf Pipette Research plus G, single-channel, variable, 2–20 µL, light grey, epT.I.P.S. box, 3123000098 Eppendorf Pipette Research plus G, single-channel, variable, 2–20 µL, yellow, epT.I.P.S. box, 3123000039. This allows you to put together a suitable combination of several volume ranges without having to switch to a different product line.
Use, storage and maintenance
The upper and lower sections can be autoclaved together at 121 °C and 1 bar overpressure for 20 minutes; it is not necessary to dismantle the lower section for this. The filter sleeve and protective filter are autoclaved separately. No re-lubrication is required after autoclaving; a gravimetric accuracy check is recommended afterwards. The pipette is stored without transport packaging at temperatures between –5 and 45 degrees Celsius and relative humidity of 10 to 95 per cent; during operation, the temperature range is 5 to 40 degrees Celsius within the same humidity range. Warranty claims are handled via the relevant Eppendorf authorised partner; claims are excluded for damage resulting from misuse, unauthorised opening of the upper section, and wear and tear on typical wear parts.
Fixed volume or variable setting
Anyone who switches between several volumes within the same range in their day-to-day work – for example, when carrying out dilution series or handling different sample volumes per batch – will find a variable-volume pipette more flexible than using several fixed-volume devices. For a single, recurring value, however, a fixed-volume pipette from the Research-plus range is the better choice, as it prevents the adjustment wheel from being turned in the first place.
Frequently asked questions
Is the Eppendorf Research plus 1–10 mL autoclavable?
Yes. The upper and lower sections can be autoclaved together at 121 degrees Celsius and 1 bar overpressure for 20 minutes without the lower section needing to be dismantled. The filter sleeve and protective filter are autoclaved separately.
Is re-greasing necessary after autoclaving?
No, according to the manufacturer, there is no need to re-grease the pistons after autoclaving. However, it is still recommended to carry out a gravimetric check of the accuracy afterwards.
How is the volume set on the variable model?
Via the mechanical adjustment wheel on the pipette head, without a display or electronics. The set value is retained until the next adjustment.
Which pipette tips are compatible with the Eppendorf Research plus 1–10 mL?
According to the operating instructions, epT.I.P.S. turquoise 165 mm (1–10 mL).
Is the pipette an in vitro diagnostic device?
According to the operating instructions, the Research plus range is designed for the low-contamination transfer of liquids, including samples from the human body and reagents within the context of an in vitro diagnostic application as defined by Directive 98/79/EC.
To whom should warranty claims be addressed?
To the relevant Eppendorf authorised dealer. Excluded are damages resulting from misuse, unauthorised opening of the upper part, and wear and tear of typical wear parts.
Can the pipette be readjusted if it deviates from the factory setting?
According to the manufacturer, secondary calibration is provided for the Research-plus range. Details are set out in a separate Eppendorf calibration document, the full text of which was not available at the time of writing.
What does the IVD marking on the Research-plus range signify?
The user manual generically refers to the pipette as an in vitro diagnostic device within the meaning of Directive 98/79/EC, for the entire Research-plus range. No product-specific confirmation was available at the time of writing.
Technical details
| Range | Eppendorf Research plus | |
| Model | variable | |
| Volume | 1–10 mL | |
| Increment | 0.01 mL | |
| Colour code | turquoise | |
| Compatible pipette tip | epT.I.P.S. turquoise 165 mm (1–10 mL) | |
| Test volume 1.0 mL | Systematic measurement error 3.0%/30 µL | Random measurement error 0.6%/6 µL |
| Test volume 5.0 mL | Systematic measurement error: 0.8%/40 µL | Random measurement error 0.2%/10 µL |
| Test volume 10.0 mL | Systematic measurement error 0.6%/60 µL | Random measurement error 0.15%/15 µL |
| Standard | Test in accordance with ISO 8655 |
Contents
- 1 Eppendorf Research plus single-channel pipette (1–10 mL, turquoise)
Individual requirements & procurement service
For suitable pipette tips, spare parts or additional volume ranges from the Research plus range, LT Laborhandel provides support via its own procurement service at lt-laborhandel.de/service.
| Colour: | Turquoise |
|---|---|
| Number of channels: | 1-channel |
| Operation: | mechanical |
| Volume range: | 1 ml - 10 ml |
| Volume setting: | variable |