Eppendorf Xplorer Multichannel Pipette, 8-channel, 50–1,200 µL, green, 4861000163
- Electronic 8-channel pipette, 50 to 1,200 µL, step size 1 µL
- Fixed tip cone spacing 9 mm for 96-well plates
- Colour code green for epT.I.P.S. 50 to 1,250 µL
- 5 pipetting modes, colour display with multifunction rocker
- Lithium-polymer battery, lower part autoclavable at 121 °C
- Conforms to ISO 8655 according to Eppendorf, 4 test volumes with measurement deviation specified
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Eppendorf Xplorer Multichannel Pipette, 8-channel, 50–1,200 µL, green, 4861000163"
A multichannel pipette fills as many wells in one operation as it has channels. The Eppendorf Xplorer 8-channel pipette for 50 to 1,200 µL has 8 channels and a fixed tip cone spacing of 9 mm. This fits 96-well plates. A motor moves the pistons of all channels simultaneously.
Fixed tip cone spacing for 96-well plates
The tip cone spacing is the distance between the centres of adjacent tip cones. For this pipette it is 9 mm and cannot be adjusted. The tips therefore sit in the grid of the plate, and each channel carries its own tip. According to Eppendorf, the colour of the pipette corresponds to the colour of the matching epT.I.P.S. Matching tips: epT.I.P.S. 50 to 1,250 µL, colour code green.
Anyone who switches between plate formats with different grids needs a pipette with adjustable tip cone spacing. For this, Eppendorf offers the Xplorer plus Move It.
Typical applications
- Loading 96-well plates with samples, reagents or media
- Preparing dilution series across a plate
- Transferring samples between plates with the same grid
- Filling rows or columns without pipetting individually
- Repeated plate work in which a manual multichannel pipette causes fatigue
Operation
Control is via the colour display and multifunction rocker. The rocker follows the principle ‘up is up, down is down’. The motor does the pipetting itself, and the hand only triggers it. The pipette has five pipetting modes (Pip, Dis, Ads, P/M and Man) and eight speed settings. Volumes are set with a step size of 1 µL. The display is available in nine languages. Adjustment is possible according to liquid type, altitude and extended tips, with 1, 2 or 3 points.
Battery, power supply and autoclaving
The lithium-polymer battery (3.7 V, 750 mAh) takes approx. 3 hours to charge. According to the data sheet, one charge lasts for up to 8 hours of use. Work can continue while the pipette is on the power supply. The lower part can be autoclaved at 121 °C and 1 bar for 20 minutes, the upper part cannot. The pipette is UV-resistant at 254 nm. The power supply takes 100 to 240 V ±10 % at 50 to 60 Hz and delivers 5 V at 1 A. Mains plug adaptors of types A, C, G and I are included. Software updates can be installed via Micro-USB. The pipette is operated at +5 °C to +40 °C and 10 to 95 % relative humidity. For storage, Eppendorf specifies -5 °C to +45 °C.
Technical details
| Feature | Value |
|---|---|
| Series | Eppendorf Xplorer, electronic |
| Channels | 8 |
| Volume range | 50 to 1,200 µL |
| Step size | 1 µL |
| Tip cone spacing | 9 mm, fixed |
| Plate grid | 96-well plates |
| Colour code | green |
| Matching tip | epT.I.P.S. 50 to 1,250 µL |
| Pipetting modes | 5 |
| Speed settings | 8 |
| Display | Colour display, 9 languages |
| Battery | Lithium-polymer, 3.7 V, 750 mAh, charging time approx. 3 hours |
| Power supply | 100 to 240 V ±10 %, 50 to 60 Hz, with mains plug adaptors |
| Autoclavable | Lower part, 121 °C, 1 bar, 20 minutes |
| Operating conditions | +5 °C to +40 °C, 10 to 95 % relative humidity |
| Storage | -5 °C to +45 °C |
| Standard | Conformity with ISO 8655 according to Eppendorf |
| Manufacturer | Eppendorf |
| Manufacturer number | 4861000163 |
Measurement deviations
For this pipette, Eppendorf specifies 4 test volumes. According to Eppendorf, the values apply only with original epT.I.P.S. Eppendorf determines them gravimetrically according to ISO 8655, with 10 determinations per volume and water according to ISO 3696. The systematic error describes how far the mean value deviates from the set volume. The random error describes the scatter of the individual values.
| Test volume | Systematic error | Random error |
|---|---|---|
| 50 µL | ±8 % / ±4 µL | ±1.2 % / ±0.6 µL |
| 120 µL | ±6 % / ±7.2 µL | ±0.9 % / ±1.08 µL |
| 600 µL | ±2.7 % / ±16.2 µL | ±0.4 % / ±2.4 µL |
| 1,200 µL | ±1.2 % / ±14.4 µL | ±0.3 % / ±3.6 µL |
Scope of delivery
- Pipette
- Power supply with mains plug adaptors
- Operating instructions
- Quick guide
- Certificate
- Pipette grease
Depending on the model, further parts are included, for example locking rings for deactivating the spring loading, an O-ring tool or an unlocking tool. Pipette tips are not included in the scope of delivery.
Accessories and procurement
The Charger 2 charger stand and the Charger Carousel 2 charging carousel are also available. Both charge the pipette via charging contacts. The procurement service helps with tips and other Eppendorf accessories on request.
| Colour: | Green |
|---|---|
| Number of channels: | 8-channel |
| Operation: | electronic |
| Volume range: | 50 µl - 1200 µl |
| Volume setting: | variable |