IKA myPlate, magnetic stirrer without heating, customisable glass surface, 0025005156
€317.25
% Manufacturer's RRP: €423.00 25% below manufacturer's RRP
- Magnetic stirrer without a heating function for thermolabile samples
- Customisable interchangeable frame beneath the glass plate
- Maximum hydrodynamic stirring capacity of 1.5 L
- Powerful rotational dynamics up to 2500 rpm
- Solid real glass base with a diameter of 135 mm
- Capacitive touch slider and digital LED display
- High level of occupational health and safety protection thanks to IP 54 rating
- Manufacturer’s part number (MPN): 0025005156 | EAN: 4053411047672
Product information "IKA myPlate, magnetic stirrer without heating, customisable glass surface, 0025005156"
Electromagnetic Rotational Kinematics and Fluid Mechanics
The homogeneous mixing of aqueous or low-viscosity matrices on a laboratory scale requires a compact, high-frequency power transmission system. The IKA myPlate operates as a purely electromagnetic stirrer (without a thermodynamic heating unit) and is designed for a hydrodynamic working capacity of up to 1.5 L (based on water). The brushless drive generates a continuously variable rotating magnetic field that synchronises the rotor in the reaction vessel at a frequency of 0 to 2,500 revolutions per minute. This asymmetrically wide speed range creates a massive axial flow vortex. The resulting centrifugal forces and shear stresses maximise molecular mass transfer (mixing kinetics) and completely eliminate fluid dynamic dead zones in the beaker or Erlenmeyer flask.
Amorphous glass matrix and optical system architecture
The materials science architecture of the large mounting surface (Ø 135 mm) is based on a monolithic layer of tempered real glass. This amorphous silicate structure guarantees absolute inertness towards highly aggressive chemical reagents, strong acids or alkalis, which would irreversibly corrode conventional plastic housings in the event of a spill. A distinctive feature of this chassis’s design is the integrated, tool-free removable insert frame. This allows the instrument’s surface to be visually customised by inserting individual printed media, without blocking the magnetic field lines or compromising the metrological enclosure. As the system is thermodynamically decoupled, thermal denaturation of thermolabile samples is physically impossible.
Metrological cybernetics and capacitive interface control
The mechanical drive train is implemented via an electronically commutated motor (EC motor). The absence of mechanical sliding contacts eliminates tribological wear, reduces power consumption to a minimum of 4 W and qualifies the system for continuous operation without thermal stress. Metrological control of the process is carried out via a capacitive sensor keypad (touch slider) and a digital LED display. The integrated sensor technology translates the manual swiping gesture instantly into an incremental adjustment of the rotational speed and provides seamless visual feedback on the rotational kinematics.
Technical details
Kinematics & Fluid Mechanics
- Process principle: Electromagnetic rotation
- Maximum stirring volume (H₂O): 1.5 L
- Speed range: 0 – 2,500 rpm
- Speed display: Digital LED display
- Speed adjustment: Capacitive touch slider
- Maximum stir bar length: 30 mm
- Motor power input / output: 4 W / 2 W
- Motor type: Electronically commutated DC motor (EC motor)
Materials Science & Systems Architecture
- Base material: Tempered real glass (amorphous silicate matrix)
- Modular design: Integrated interchangeable frame for visual customisation
- Base dimensions: Ø 135 mm
- System dimensions (W x H x D): 152 x 30 x 164 mm
- Machine weight: 0.5 kg
- Housing material: High-performance plastic with real glass cover
Safety & environmental conditions
- Permissible ambient temperature range: 5 – 40 °C
- Permissible relative humidity: max. 80 %
- Protection class (to DIN EN 60529): IP 54 (protection against dust and splashing water)
- Thermal influence: None, as it is a purely kinetic unit without a heating matrix
Electrical & Infrastructure
- Voltage / frequency (mains adaptor): 100 – 240 V / 50/60 Hz
- DC input on the unit: 12 V
- Current consumption: 300 mA
Contents of delivery
- 1 x IKA myPlate magnetic stirrer
- 1 x mains power supply (including adapter)
- 1 x blank paper insert for personalisation
Important note: Magnetic stirring rods for hydrodynamic energy transfer into the fluid are essential for operation and are not included in the scope of delivery! Due to the magnetic pole spacing within the chassis, only stirring rods with a maximum length of 30 mm may be used to prevent asymmetric flow separation (decoupling).
Individual requirements & accessories
The IKA myPlate generates a rotating magnetic field but, without a suitable rotor, does not induce any mechanical flow vectors. For maximum efficiency in 1.5 L beakers, we recommend using cylindrical, PTFE-coated IKAFLON magnetic stirring rods (max. 30 mm in length). To retrieve the magnetic stir bars without contamination after homogenisation, you will also need a PTFE magnetic stir bar retriever. Please contact our procurement service at any time for the fluid-dynamically correct configuration of your stirring setup.