IKA OVEN 125 control dry, drying oven, 0020003990
€3,108.75
% Manufacturer's RRP: €4,145.00 25% below manufacturer's RRP
- Drying oven with forced air circulation and a 125 l stainless steel interior
- Room temperature plus 5 °C to 300 °C, resolution 0.1 K
- Two TFT displays, temperature and user profiles
- Real-time clock with delayed start, data storage on USB stick
- USB-B, RS 232 and connection for an additional sensor
- Safety circuit adjustable from 50 to 320 °C
- 3-year manufacturer’s warranty upon registration within 90 days
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "IKA OVEN 125 control dry, drying oven, 0020003990"
The IKA OVEN 125 control dry (0020003990) is a drying oven with forced air circulation and a 125 l interior that heats up to 300 °C. Two TFT displays show the process parameters, whilst temperature profiles and user profiles are created via the user interface. It is the version of the OVEN 125 series designed for scheduled runs, higher temperatures and the recording of test data. The basic dry, on the other hand, heats up to 250 °C and operates using natural convection.
Forced air circulation and temperature
The oven operates with forced air circulation. The fan switches off automatically when the door is opened. The operating range extends from room temperature plus 5 °C to 300 °C; the resolution for setting and display is 0.1 K. IKA specifies the temperature stability as ±0.5 K at 150 °C in the centre of the chamber. According to IKA, thanks to its insulation, the unit has a very large internal volume relative to its overall size and a uniform spatial temperature distribution; odour emissions and operating costs are also reduced.
Displays, profiles and real-time clock
The two TFT displays show the most important process parameters simultaneously. Temperature profiles and individual user profiles are entered via the user interface. The real-time clock allows for a delayed start and the digital documentation of runs. The timer can be set from 1 to 142,560 minutes, which equates to 99 days.
Interfaces and measurements in the test material
Test parameters can be saved directly to a USB stick; there is also a USB-B port and an RS-232 interface. A further port is intended for an additional sensor, which is used to control the temperature directly within the test material. This sensor is not included in the scope of delivery. The cabinet features a rear cable feed-through for measurements inside the oven or within the test material. The stainless steel interior is illuminated.
Safety circuit
The safety circuit is adjustable from 50 to 320 °C. According to DIN 12880, IKA specifies a Class 1 thermal safety device (TB) and a second Class 3.1 device (TWW). In the product description, IKA also specifies a adjustable temperature limiter (TWB) according to DIN 12880. According to IKA, the temperature profile can be monitored independently of the safety temperature.
Loading and installation
The chamber measures 550 x 525 x 450 mm (W x H x D). It can accommodate up to 6 grid shelves, each with a maximum load of 30 kg. The cabinet measures 700 x 825 x 650 mm (W x H x D) externally and weighs 82 kg. The permissible ambient temperature is 5 to 40 °C and relative humidity up to 80 %, the degree of protection is IP 20. The air outlet has an internal diameter of 48 mm.
Connection
The cabinet is powered by 220 to 240 V at 50/60 Hz. The heating power is 2,400 W, the power consumption is 2,500 W, and in standby mode it is 2 W. Before installation, the fuse rating of the socket and the load-bearing capacity of the installation site should be checked.
Typical applications
- Drying and tempering up to 300 °C, where the basic dry model stops at 250 °C
- Ageing tests with a temperature profile that is set across several stages and can be recalled
- Time-delayed start-up cycles, for example to ensure the chamber has reached the required temperature by the start of work
- Measurements taken directly within the test material, provided an additional sensor is connected
- Documented test runs in quality control and research, with data saved to a USB stick or via the interfaces
Choice within the OVEN 125 range
For those drying up to 250 °C and requiring simple operation without profiles, the OVEN 125 basic dry is the simpler option. The control dry is worthwhile from 250 °C upwards, for profile runs and when data needs to be stored. With a glass door, it is available as the OVEN 125 control dry glass.
Technical details
| Internal volume | 125 l |
|---|---|
| Operating temperature | Room temperature +5 °C to 300 °C |
| Safety circuit | adjustable from 50 to 320 °C |
| Setting and display resolution | 0.1 K |
| Temperature stability (150 °C, centre of chamber) | ±0.5 K |
| Heat transfer | Forced air circulation with fan; fan switches off when the door is open |
| Display | 2 TFT displays |
| Timer | 1 to 142,560 minutes, LCD display, real-time clock with delayed start |
| Interior | Stainless steel, illuminated |
| Inner chamber working area (W x H x D) | 550 x 525 x 450 mm |
| Grid shelves | max. 6; max. load per grid shelf: 30 kg |
| Air outlet opening (internal diameter) | 48 mm |
| Cable feed-through | at the rear, for measurements in the oven or in the test material |
| Thermal safety devices according to DIN 12880 | TB Class 1, additionally TWW Class 3.1 |
| Interfaces | USB-B (saving to USB stick), RS 232, connection for additional sensor |
| Dimensions (W x H x D) | 700 x 825 x 650 mm |
| Weight | 82 kg |
| Permissible ambient temperature | 5 to 40 °C |
| Permissible relative humidity | max. 80 % |
| Degree of protection according to DIN EN 60529 | IP 20 |
| Voltage, frequency | 220 to 240 V, 50/60 Hz |
| Heating power | 2,400 W |
| Power consumption | 2,500 W, 2 W on standby |
Scope of delivery
- 1 x IKA OVEN 125 control dry drying oven
- 2 x grid shelves (IO T 1.00)
- 2 x tilt protection units
- 1 x screwdriver for adjusting the temperature limiter
- 1 x USB cable (A to B)
- 1 x calibration certificate at 160 °C
An additional sensor for temperature control within the test material is not included in the scope of delivery.
Regulatory information
The device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer IKA is DE 66784213. Information on returning old appliances can be found on our page Environment and disposal.
Warranty
IKA manufacturer’s warranty: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.
Frequently asked questions
How long is the warranty valid for?
IKA manufacturer’s warranty: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.
Where are the test parameters stored?
Directly on a USB stick. The unit also has a USB-B port and an RS-232 interface.
Can the temperature of the test material be controlled?
Yes, via the connection for an additional sensor. The sensor is not included in the scope of delivery.
What happens to the fan when the door is open?
The fan switches off automatically when the door is open.
How heavy is the cabinet?
82 kg with external dimensions of 700 x 825 x 650 mm (W x H x D).
Individual requirements and procurement service
For additional grid shelves, a suitable sensor or other accessories for the OVEN 125 control dry, we accept enquiries via our procurement service.