Product information "IKA OVEN 125 control dry glass, drying oven, 0020003996"

Programmed cycles up to 300 °C, during which the sample can be viewed: this is what the IKA OVEN 125 control dry glass (0020003996) is designed for. It is a drying oven with forced air circulation, a 125 l interior, two TFT displays and a glass door. Technically, it is identical to the OVEN 125 control dry; only the door and weight differ.

Glass door and forced air circulation

According to IKA, the glass door allows for better observation of the samples. The fan circulates the air and switches off as soon as the door is opened. The stainless steel interior is illuminated, so that the sample can be clearly seen even when the door is closed. The oven weighs 89 kg and measures 700 x 825 x 650 mm (W x H x D) externally.

Controls and profiles

The operating range starts at room temperature plus 5 °C and ends at 300 °C; settings and displays are in 0.1 K increments. IKA specifies a temperature stability of ±0.5 K at 150 °C in the centre of the chamber. Two TFT displays show the process parameters. Temperature profiles and individual user profiles are created via the user interface; the real-time clock allows the start time to be delayed. The timer runs from 1 to 142,560 minutes.

Connections

Test parameters are written directly to a USB stick. There is also a USB-B port, an RS-232 interface and a connection for an additional sensor capable of controlling the temperature within the test material. The sensor is not included in the scope of delivery. A cable feed-through at the rear feeds measurement leads into the cabinet.

Safety

The safety circuit is adjustable from 50 to 320 °C. IKA specifies one Class 1 device (TB) and a second Class 3.1 device (TWW) according to DIN 12880.

Loading

The chamber, measuring 550 x 525 x 450 mm (W x H x D), can accommodate up to 6 grid shelves, each with a maximum load of 30 kg. Two grid shelves and two tilt protection units are included.

Typical applications

  • Running temperature profiles and checking the condition of the samples through the glass door without interrupting the cycle
  • Curing and drying coatings at temperatures up to 300 °C
  • Ageing tests with a temperature programme, the progress of which is saved to a USB stick or via the interfaces
  • Runs with a delayed start, for example so that the chamber is hot when work begins
  • Lectures and practical sessions where the sample needs to remain visible

Connection and installation

The cabinet is operated at 220 to 240 V at 50/60 Hz. The heating power is 2,400 W, the power consumption is 2,500 W, and in standby mode it is 2 W. The permissible ambient temperature is 5 to 40 °C and relative humidity up to 80 %, the degree of protection is IP 20. Weighing 89 kg, the cabinet requires a suitably load-bearing installation site.

Differences from the control dry

The IKA OVEN 125 control dry has a closed door and weighs 82 kg, whilst the control dry glass version weighs 89 kg. According to the data sheet, the heating power, interior, safety circuit and interfaces are identical. If temperatures up to 250 °C are sufficient and forced air circulation is not required, the OVEN 125 basic dry glass is the simpler choice.

Technical details

Internal volume125 l
Operating temperatureRoom temperature +5 °C to 300 °C
Safety circuitadjustable from 50 to 320 °C
Setting and display resolution0.1 K
Temperature stability (150 °C, centre of chamber)±0.5 K
Heat transferForced air circulation with fan; fan switches off when the door is open
Display2 TFT displays
Timer1 to 142,560 minutes, LCD display, real-time clock with delayed start
InteriorStainless steel, illuminated
Inner chamber working area (W x H x D)550 x 525 x 450 mm
Grid shelvesmax. 6; max. load per grid shelf: 30 kg
Air outlet opening (internal diameter)48 mm
Cable feed-throughat the rear, for measurements in the oven or in the test material
DoorGlass door
Thermal safety devices according to DIN 12880TB Class 1, additionally TWW Class 3.1
InterfacesUSB-B (saving to USB stick), RS 232, connection for additional sensor
Dimensions (W x H x D)700 x 825 x 650 mm
Weight89 kg
Permissible ambient temperature5 to 40 °C
Permissible relative humiditymax. 80 %
Degree of protection according to DIN EN 60529IP 20
Voltage, frequency220 to 240 V, 50/60 Hz
Heating power2,400 W
Power consumption2,500 W, 2 W on standby

Scope of delivery

  • 1 x IKA OVEN 125 control dry glass drying oven
  • 2 x grid shelves (IO T 1.00)
  • 2 x tilt protection units
  • 1 x screwdriver for adjusting the temperature limiter
  • 1 x USB cable (A to B)
  • 1 x calibration certificate at 160 °C

An additional sensor for temperature control within the test material is not included in the scope of delivery.

Regulatory information

The device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer IKA is DE 66784213. Information on returning old appliances can be found on our page Environment and disposal.

Warranty

IKA manufacturer’s warranty: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.

Frequently asked questions

How long does the warranty last?
IKA manufacturer’s warranty: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.

What is the difference between control dry glass and control dry?
It has a glass door. This makes the cabinet heavier, at 89 kg instead of 82 kg. The temperature range up to 300 °C, forced air circulation, displays and interfaces are the same.

Where are the test parameters stored?
Directly on a USB stick. The oven also has a USB-B port and an RS-232 interface.

Is the sensor for control in the test material included?
No. The connection is provided, but the sensor is not included in the scope of delivery.

Individual requirements and procurement service

We arrange for additional grid shelves, a sensor for temperature control within the test material or other accessories on request. The procurement service will record your requirements.