IKA OVEN 125 control dry glass, drying oven, 0020003996
€3,498.00
% Manufacturer's RRP: €4,664.00 25% below manufacturer's RRP
- Drying oven with forced air circulation and glass door, 125 l stainless steel interior
- Room temperature plus 5 °C to 300 °C, temperature stability ±0.5 K at 150 °C
- Two TFT displays, temperature and user profiles
- Illuminated interior; fan switches off when the door is open
- USB-B, RS 232, data storage on USB stick, connection for additional sensor
- Safety circuit adjustable from 50 to 320 °C
- 3-year manufacturer’s warranty upon registration within 90 days
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "IKA OVEN 125 control dry glass, drying oven, 0020003996"
Programmed cycles up to 300 °C, during which the sample can be viewed: this is what the IKA OVEN 125 control dry glass (0020003996) is designed for. It is a drying oven with forced air circulation, a 125 l interior, two TFT displays and a glass door. Technically, it is identical to the OVEN 125 control dry; only the door and weight differ.
Glass door and forced air circulation
According to IKA, the glass door allows for better observation of the samples. The fan circulates the air and switches off as soon as the door is opened. The stainless steel interior is illuminated, so that the sample can be clearly seen even when the door is closed. The oven weighs 89 kg and measures 700 x 825 x 650 mm (W x H x D) externally.
Controls and profiles
The operating range starts at room temperature plus 5 °C and ends at 300 °C; settings and displays are in 0.1 K increments. IKA specifies a temperature stability of ±0.5 K at 150 °C in the centre of the chamber. Two TFT displays show the process parameters. Temperature profiles and individual user profiles are created via the user interface; the real-time clock allows the start time to be delayed. The timer runs from 1 to 142,560 minutes.
Connections
Test parameters are written directly to a USB stick. There is also a USB-B port, an RS-232 interface and a connection for an additional sensor capable of controlling the temperature within the test material. The sensor is not included in the scope of delivery. A cable feed-through at the rear feeds measurement leads into the cabinet.
Safety
The safety circuit is adjustable from 50 to 320 °C. IKA specifies one Class 1 device (TB) and a second Class 3.1 device (TWW) according to DIN 12880.
Loading
The chamber, measuring 550 x 525 x 450 mm (W x H x D), can accommodate up to 6 grid shelves, each with a maximum load of 30 kg. Two grid shelves and two tilt protection units are included.
Typical applications
- Running temperature profiles and checking the condition of the samples through the glass door without interrupting the cycle
- Curing and drying coatings at temperatures up to 300 °C
- Ageing tests with a temperature programme, the progress of which is saved to a USB stick or via the interfaces
- Runs with a delayed start, for example so that the chamber is hot when work begins
- Lectures and practical sessions where the sample needs to remain visible
Connection and installation
The cabinet is operated at 220 to 240 V at 50/60 Hz. The heating power is 2,400 W, the power consumption is 2,500 W, and in standby mode it is 2 W. The permissible ambient temperature is 5 to 40 °C and relative humidity up to 80 %, the degree of protection is IP 20. Weighing 89 kg, the cabinet requires a suitably load-bearing installation site.
Differences from the control dry
The IKA OVEN 125 control dry has a closed door and weighs 82 kg, whilst the control dry glass version weighs 89 kg. According to the data sheet, the heating power, interior, safety circuit and interfaces are identical. If temperatures up to 250 °C are sufficient and forced air circulation is not required, the OVEN 125 basic dry glass is the simpler choice.
Technical details
| Internal volume | 125 l |
|---|---|
| Operating temperature | Room temperature +5 °C to 300 °C |
| Safety circuit | adjustable from 50 to 320 °C |
| Setting and display resolution | 0.1 K |
| Temperature stability (150 °C, centre of chamber) | ±0.5 K |
| Heat transfer | Forced air circulation with fan; fan switches off when the door is open |
| Display | 2 TFT displays |
| Timer | 1 to 142,560 minutes, LCD display, real-time clock with delayed start |
| Interior | Stainless steel, illuminated |
| Inner chamber working area (W x H x D) | 550 x 525 x 450 mm |
| Grid shelves | max. 6; max. load per grid shelf: 30 kg |
| Air outlet opening (internal diameter) | 48 mm |
| Cable feed-through | at the rear, for measurements in the oven or in the test material |
| Door | Glass door |
| Thermal safety devices according to DIN 12880 | TB Class 1, additionally TWW Class 3.1 |
| Interfaces | USB-B (saving to USB stick), RS 232, connection for additional sensor |
| Dimensions (W x H x D) | 700 x 825 x 650 mm |
| Weight | 89 kg |
| Permissible ambient temperature | 5 to 40 °C |
| Permissible relative humidity | max. 80 % |
| Degree of protection according to DIN EN 60529 | IP 20 |
| Voltage, frequency | 220 to 240 V, 50/60 Hz |
| Heating power | 2,400 W |
| Power consumption | 2,500 W, 2 W on standby |
Scope of delivery
- 1 x IKA OVEN 125 control dry glass drying oven
- 2 x grid shelves (IO T 1.00)
- 2 x tilt protection units
- 1 x screwdriver for adjusting the temperature limiter
- 1 x USB cable (A to B)
- 1 x calibration certificate at 160 °C
An additional sensor for temperature control within the test material is not included in the scope of delivery.
Regulatory information
The device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer IKA is DE 66784213. Information on returning old appliances can be found on our page Environment and disposal.
Warranty
IKA manufacturer’s warranty: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.
Frequently asked questions
How long does the warranty last?
IKA manufacturer’s warranty: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.
What is the difference between control dry glass and control dry?
It has a glass door. This makes the cabinet heavier, at 89 kg instead of 82 kg. The temperature range up to 300 °C, forced air circulation, displays and interfaces are the same.
Where are the test parameters stored?
Directly on a USB stick. The oven also has a USB-B port and an RS-232 interface.
Is the sensor for control in the test material included?
No. The connection is provided, but the sensor is not included in the scope of delivery.
Individual requirements and procurement service
We arrange for additional grid shelves, a sensor for temperature control within the test material or other accessories on request. The procurement service will record your requirements.