Kern ACJ 80-4M analytical balance 82 g / 0.0001 g
€1,233.00
% Manufacturer's RRP: €1,370.00 10% below manufacturer's RRP
- Weighing range 82 g, readability 0.0001 g
- Reproducibility 0.0002 g, linearity ± 0.0003 g
- Minimum load 0.01 g, verification value e = 0.001 g, stabilisation time 3 s
- LCD display, glass draught shield, internal automatic adjustment, units g and mg
- RS-232 and USB device, die-cast aluminium and plastic housing
- Conformity assessment under NAWI (2014/31/EU) optional ex works, item no. 965-201
Product information "Kern ACJ 80-4M analytical balance 82 g / 0.0001 g"
The Kern ACJ is an analytical balance with a single-cell weighing system, a glass draught shield and an internal automatic adjustment. Four models weigh from 82 g to 320 g and read to 0.0001 g (0.1 mg). The verification value is e = 0.001 g for all models, the accuracy class is I. Anyone who uses the balance in applications subject to mandatory verification should order the optional conformity assessment under the NAWI Directive (2014/31/EU) ex works along with it.
The same accuracy in four weighing ranges
Readability, reproducibility (0.0002 g), linearity (± 0.0003 g), minimum load (0.01 g) and stabilisation time (3 s) are the same for all four models. The choice therefore depends on the maximum weight to be weighed: the ACJ 80-4M weighs up to 82 g, the ACJ 100-4M up to 120 g, the ACJ 200-4M up to 220 g and the ACJ 300-4M up to 320 g. The three larger models also display carats (ct), whilst the ACJ 80-4M displays only g and mg.
Adjustment and documentation
The internal automatic adjustment adjusts the balance when the temperature changes by 2 °C or more and additionally every 4 h. This does not replace a calibration certificate, which is available separately (see below). The four-digit balance identification number is freely programmable and is printed on the adjustment report. A high-stability mode and other filter settings are available as a dosing aid. When formulating, the balance numbers the mixture components and prints them with number and weight value; tare and print are combined on one key for this. After each standstill of the balance, the data go automatically to a PC or printer via RS-232 or USB device.
Functions and design
The ACJ counts pieces (minimum unit weight 1 mg under laboratory conditions, 10 mg under standard conditions), determines percentages and density, adds up formulation components with Net-Total and measures with tolerance range. The LCD display has digits 14 mm high. The stainless steel weighing pan has a diameter of 91 mm. The weighing chamber behind the glass draught shield measures 174 x 162 x 227 mm. The spirit level and adjustable feet are used for levelling. The housing is made of die-cast aluminium and plastic.
Typical applications
- Pharmacies: weighing in formulation components with a numbered printout
- Food analysis: percentage and density determination
- Environmental analysis: sample weighing with balance ID in the adjustment report
- Chemical industry: preparing solutions
- Research and development: weighing in portions in the milligram range
Models at a glance
| Model | Weighing range (Max) | Readability (d) | Verification value (e) | Minimum load (Min) | Reproducibility | Linearity | Stabilisation time | Units |
|---|---|---|---|---|---|---|---|---|
| ACJ 80-4M | 82 g | 0.0001 g | 0.001 g | 0.01 g | 0.0002 g | ± 0.0003 g | 3 s | g, mg |
| ACJ 100-4M | 120 g | 0.0001 g | 0.001 g | 0.01 g | 0.0002 g | ± 0.0003 g | 3 s | g, mg, ct |
| ACJ 200-4M | 220 g | 0.0001 g | 0.001 g | 0.01 g | 0.0002 g | ± 0.0003 g | 3 s | g, mg, ct |
| ACJ 300-4M | 320 g | 0.0001 g | 0.001 g | 0.01 g | 0.0002 g | ± 0.0003 g | 3 s | g, mg, ct |
Technical details
These values apply to all models. Deviating values are given in the model table.
| Weighing system | Single cell |
| Accuracy class | I |
| Weighing pan | Stainless steel, Ø 91 mm |
| Weighing chamber (W x D x H) | 174 x 162 x 227 mm |
| Display | LCD, digit height 14 mm |
| Interfaces | RS-232 (standard), USB device |
| Housing | Die-cast aluminium, plastic |
| Housing dimensions (W x D x H) | 213 x 333 x 338 mm |
| Net weight | approx. 7 kg |
| Power supply | Plug-in mains adaptor, 110 V to 230 V AC |
| Ambient temperature | 10 °C to 30 °C |
| Humidity | 20 % to 85 % |
| Conformity assessment under NAWI (2014/31/EU) | optional, available ex works only, item no. 965-201 |
| DAkkS calibration certificate | can be ordered separately, item no. 963-101 |
| Warranty (manufacturer) | 36 months according to Kern, excluding wear parts |
Conformity assessment and calibration
A conformity assessment under the NAWI Directive (2014/31/EU) is optional (item no. 965-201). It can only be ordered ex works together with the balance; according to Kern, a subsequent conformity assessment is not possible. To place an order, Kern needs the full address of the installation site. A DAkkS calibration certificate (item no. 963-101) can be ordered separately. The confirmation of manufacturer specification (969-517) is only available in conjunction with the DAkkS calibration certificate.
Scope of delivery
- Kern ACJ analytical balance with stainless steel weighing pan (Ø 91 mm) and glass draught shield
- Working protective cover
- Plug-in mains adaptor with country adaptors for EU, AUS, UK, US and CH
Warranty
According to Kern & Sohn, these devices come with a 3-year warranty. Kern grants 3 years on products with a list price of €500 or more and 2 years on products below that and on components; wear parts such as batteries and rechargeable batteries are excluded. Warranty repairs are carried out by Kern or by a Kern dealer.
Downloads
Regulatory information
As electrical devices, the balances fall under the ElektroG. The manufacturer Kern & Sohn GmbH is registered under the WEEE registration number DE 80821200. How to return old appliances is described on the page Environment and disposal.
Individual requirements and procurement service
Dust cover (ABS-A08), working protective covers (ACS-A02, ACS-A02S05 with 5 pieces), ionisers (ABP-A01, YBI-01A), density determination kit (YDB-03), anti-vibration table (YPS-03), anti-vibration plates (YPS-04, YPS-05), thermal printers (YKC-01, YKH-01), dot-matrix printer (YKG-01), needle printer (YKT-01), RS232 Bluetooth adapter (YKI-02), RS232 Ethernet converters (YKI-10, YKI-11), RS232 WLAN converter (YKI-12), RS-232 interface cable (MLB-A05) and USB 2.0 cable (DBS-A04) are also available. For the ACJ 100-4M, Kern also lists the test weight 316-07 (OIML class E2, nominal value 100 g, compact form, polished stainless steel) and the Safety Set 315-107-103 with weights of 5 g (E2) and 100 g (E2). Enquiries are handled via our procurement service.
| Weighing range (Max): | 82 g |
|---|---|
| Readability (d): | 0.0001 g |
| Verifiable: | yes |
| Design: | ACJ 80-4M (82 g / 0,0001 g) |
| Power supply: | Mains operation |