Skip to main content Skip to search Skip to main navigation

Memmert holder for water canister B49092 for HPPeco constant climate chamber, sizes 110 and 260

ⓘ  This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.

Product information "Memmert holder for water canister B49092 for HPPeco constant climate chamber, sizes 110 and 260"

The holder B49092 takes a water canister and is mounted on the rear wall of the unit. For sizes 110 to 750 the canister holds 2.5 litres, for sizes 1060, 1400 and 2200 it holds 10 litres. For sizes 410, 750, 1060, 1400 and 2200 the holder is part of the standard equipment. Here it is listed for the HPPeco constant climate chambers in sizes 110 and 260. The size corresponds to the number in the unit name, for example HPP110eco or HPP260eco.

According to Memmert, the HPPeco increases the humidity by evaporating water from a canister and feeding it into the interior. The table shows the compatible models.

Typical applications

Typical uses in the compatible units:

  • Stability studies of individual active substance batches according to ICH Q1A in pharmaceutical quality assurance, for example in the HPP110eco
  • Stability tests for cosmetic formulations on a smaller development scale, for example in the HPP110eco
  • Parallel stability studies of several active substance batches according to ICH Q1A, for example in the HPP260eco

Suitable for

ModelSizeInterior volume (l)
HPP110eco110108
HPP260eco260256

Technical details

Mountingon the rear wall of the unit
Water canister for sizes 110 to 7502.5 litres
Water canister for sizes 1060, 1400 and 220010 litres

Scope of delivery

  • 1 holder for water canister

Individual requirements & procurement service

For water canisters, for the holder in other sizes and for questions about compatibility, our procurement service accepts enquiries.

Skip product gallery

Fits

Memmert constant climate chamber HPP110eco, 108 litres, Peltier technology without a compressor
Memmert constant climate chamber HPP110eco, 108 litres, Peltier technology without a compressor
Manufacturer number: HPP110eco

For stability testing in accordance with ICH Q1A (according to the manufacturer), or to expand existing testing capacity, the Memmert HPP110eco constant-climate chamber offers controlled temperature and controlled humidity in an internal volume of 108 litres. Heating and cooling are provided by a Peltier element in the rear wall, without the need for a compressor or conventional refrigerant.Peltier cooling without a compressor or refrigerantUnlike conventional climate chambers with compressor cooling, the HPP110eco operates using a Peltier heating and cooling system based on the heat pump principle. The element is located in the rear wall and handles both heating and cooling; there is no need for a separate refrigerant or a CFC circuit. Depending on the operating mode, the chamber covers 0 to 70 °C without humidity control or 5 to 70 °C with active humidity control; when light is applied, the operating range narrows to 15 to 40 °C. Two DIN Class A Pt100 sensors in a 4-wire configuration monitor each other and automatically take over the function of the other sensor in the event of a fault.Humidity control and ControlCOCKPIT TwinDISPLAYRelative humidity can be controlled between 10 and 90 % rh with a setting accuracy of 0.5 % rh; humidification is provided by a hot steam generator, whilst dehumidification is achieved via a cold trap using Peltier technology. The system is supplied via an external water canister with a connecting hose; a fixed water connection is not required, which also makes it easier to set up the unit away from a water mains supply. The HPP110eco is operated via the ControlCOCKPIT TwinDISPLAY, comprising two high-resolution TFT colour graphic displays for the simultaneous display of temperature and humidity, with a choice of languages including German, English, French and Chinese. The SetpointWait function only starts the actual test period once the temperature and humidity have actually reached the setpoint, a detail that ensures reproducible start times for time-critical stability protocols.Selection guide: Choosing the right model from the HPPeco rangeThe HPP110eco is the smallest of the four constant-climate chambers from the HPPeco series compared here and is suitable for laboratories starting out with just a few batches per test run or looking to supplement an existing larger chamber with a compact unit for special tests. With up to 5 shelves and a maximum load capacity of 150 kg, it is sufficient for smaller sample quantities; for a greater number of parallel runs, it is worth considering its larger counterparts:Memmert Constant-Climate Chamber HPP110eco108 litres, 560 x 480 x 400 mm, approx. 64 kg, up to 5 shelvesMemmert Constant-Climate Chamber HPP260eco256 litres, 640 x 800 x 500 mm, approx. 94 kg, up to 9 shelvesMemmert Constant-Climate Chamber HPP410eco384 litres, 640 x 1,200 x 500 mm, approx. 134 kg, up to 14 shelvesMemmert Constant-Climate Chamber HPP750eco749 litres, 1,040 x 1,200 x 600 mm, approx. 197 kg, up to 14 shelvesAnyone who regularly requires more than 5 shelves at the same time or stores several batches in parallel under different ICH conditions is usually better served by the Memmert Constant-Climate Chamber HPP260eco or the Memmert Constant-Climate Chamber HPP410eco; technically, the control system, safety features and humidity system are identical across all four sizes. You can find an overview of the entire Memmert range of climate chambers and incubators in the ‘Climate Chambers & Incubators’ category.Choosing between the HPPeco and the ICH110?If you also require temperatures below 0 °C or prefer compressor-based cooling with automatic defrosting, the Memmert ICH110 climate chamber offers a suitable alternative in the same 108-litre volume class. The ICH110 cools and heats via an air-jacket temperature control system using the CFC-free refrigerant R290 and covers an operating range from -10 to +60 °C; however, at around 1,350 W, it requires a noticeably higher connected load than the HPP110eco at around 420 W. On the other hand, for those working between 0 and 70 °C without a compressor or refrigerant and with lower energy requirements, the Peltier technology of the HPP110eco is the better choice.Installation, water connection and disposalFor operation, a minimum clearance of 15 cm from the wall, a minimum clearance of 20 cm from the ceiling and a minimum clearance of 5 cm at the sides must be maintained; installation is permitted at altitudes of up to 2,000 m above sea level at ambient temperatures of 16 to 40 °C and a maximum relative humidity of 70 %, non-condensing. Humidity is supplied via the water canister supplied with the unit, which includes a connection hose and a self-priming pump; a fixed water connection in the installation room is not required. At the end of its service life, the HPP110eco must be disposed of as waste electrical and electronic equipment; Memmert is listed with the Stiftung Elektro-Altgeräte Register (Stiftung EAR) under WEEE registration number DE 66812464.Which equipment for which test purposeBefore placing an order, it is worth considering what additional equipment the chamber requires beyond the basic configuration. For documented, validatable test runs, a USB-to-Ethernet adapter for data transfer and AtmoCONTROL or myChamber software licences are suitable; on request, these are also available in the AtmoCONTROL FDA version for environments subject to 21 CFR Part 11. For unattended runs overnight or at weekends, a potential-free contact for connection to a central building management system or a MobileALERT SMS alert system are recommended. If the chamber is to be shared amongst several user groups with different access rights, a lockable door with a security lock or a USB user ID stick for the TwinDISPLAY can be added. For the installation itself, there is also a choice of a castor frame, levelling feet, a stacking kit for space-saving combinations of several chambers, and a levelling or mobile base frame.Typical applicationsWith an internal volume of 108 litres, Peltier cooling and active humidity control, the Memmert HPP110eco constant-climate chamber is particularly in demand where compact test capacity is required for recurring but not high-volume test series.Stability studies of individual batches of active ingredients in accordance with ICH Q1A in pharmaceutical quality assuranceStability tests for cosmetic formulations on a smaller development scaleSupplementary test chamber alongside a larger HPPeco chamber for special conditions or peak capacity requirementsMaterial testing in industrial quality assuranceEnvironmental testing from freezing point upwards in research and developmentFrequently asked questions about the Memmert HPP110eco constant-climate chamberWhat temperature and humidity range does the HPP110eco cover?Depending on the operating mode, 0 to 70 °C without humidity or 5 to 70 °C with active humidity control between 10 and 90 % rh; with light exposure, the operating range is restricted to 15 to 40 °C.Does the chamber require a fixed water connection?No. Humidity is supplied via the water canister supplied with the unit, complete with a connecting hose; a self-priming pump delivers the distilled water as required.How many samples can fit into the HPP110eco?Two shelves are included as standard; a total of up to five shelves, each with a maximum load of 20 kg, can be fitted, though the total load must not exceed 150 kg.Is the HPP110eco suitable for ICH stability testing?Yes, according to the manufacturer’s specifications, the chamber is designed for stability studies in accordance with ICH guidelines (Q1A) as well as for stability tests in the cosmetics and food industries.What distinguishes the HPP110eco from the Memmert ICH110 climate chamber?The HPP110eco uses a Peltier element to cool between 0 and 70 °C without a compressor or refrigerant, whilst the ICH110 operates with a compressor-based refrigeration cycle (R290) and also covers a range down to -10 °C.What software is available for documentation and validation?The chamber can be managed via the Ethernet interface using the AtmoCONTROL software; the AtmoCONTROL FDA licence version is also available for environments subject to 21 CFR Part 11.How is calibration carried out?A calibration certificate is supplied as standard (reference values: 25 °C at 60 % rh and 40 °C at 75 % rh); in addition, three freely selectable values each for temperature and humidity can be calibrated by the user. We arrange suitable services for DAkkS-accredited calibrations as well as IQ/OQ/PQ.Technical detailsAdjustable temperature range (without light, without humidity)0 to 70 °CAdjustable temperature range (with humidity)5 to 70 °COperating temperature range with light15 to 40 °CTemperature setting accuracy0.1 °CTemperature sensor2x Pt100, DIN Class A, 4-wire measurementAdjustable humidity range10 to 90 % rhHumidity setting accuracy0.5 % rhInternal volume108 lInternal dimensions (W x H x D)560 x 480 x 400 mm (depth minus 32 mm for the fan)External dimensions of the housing (W x H x D)745 x 864 x 555 mmNet weightapprox. 64 kgConnection 230 V50/60 Hz, approx. 420 WConnection 115 V50/60 Hz, approx. 420 WShelves maximum5Shelves in scope of delivery2Max. load on unit150 kgMax. load per shelf20 kgHousing materialTextured stainless steel housing, fully galvanised sheet steel rear panelControlControlCOCKPIT TwinDISPLAY, PID microprocessor controller, 2 TFT colour graphic displaysTimer1 minute to 99 days, digital countdown timerPermissible ambient temperature16 to 40 °CPermissible relative humiditymax. 70 % rel., non-condensingMaximum installation altitude2,000 mMarkingsCE, EAC, UL marksScope of delivery1x Memmert Constant-Climate Chamber HPP110ecoStandard factory calibration certificate (25 °C / 60 % rh, 40 °C / 75 % rh)Fully insulated stainless steel door with 2-point locking (compression door lock)Inner glass doorMoisture-proof silicone feed-through (internal diameter 18 mm) with silicone plug2x stainless steel grid shelf, electropolishedWater canister including connection hoseRegulatory informationThe Memmert HPP110eco constant-climate chamber is registered with the Stiftung Elektro-Altgeräte Register (Stiftung EAR) under WEEE registration number DE 66812464.Installation in a wall openingFor fixed installation in a wall opening, Memmert offers a flush-fit unit. It covers the gap between the unit and the wall opening with stainless steel and is available with air slots (B29734) or without air slots (B29735). According to Memmert, the installation situation must be clarified technically beforehand. The flush-fit unit is therefore available on request through our procurement service.Individual requirements & procurement serviceOptional extras available for the HPP110eco include a castor frame with a supply air filter, levelling feet, a stacking kit for operating multiple chambers one on top of the other, and a levelling or mobile base frame. For data acquisition, a USB-to-Ethernet adapter and AtmoCONTROL and myChamber software licences are available; licences for 21 CFR Part 11 (AtmoCONTROL FDA) are also available. In addition, we arrange calibration, IQ/OQ/PQ and maintenance services, including DAkkS calibration on request. Do you require any of these accessories, a special configuration, or assistance in selecting the right size for your application? Through our procurement service, we will be happy to assist you with procurement and configuration.

Manufacturer's RRP: €9,271.00
Topseller
Memmert constant climate chamber HPP260eco, 256 litres, Peltier technology without a compressor
Memmert constant climate chamber HPP260eco, 256 litres, Peltier technology without a compressor
Manufacturer number: HPP260eco

As soon as a single stability study develops into an ongoing test programme involving several formulations, a small chamber is often no longer sufficient. With an internal volume of 256 litres and up to 9 shelves, the Memmert HPP260eco constant-climate chamber offers significantly more capacity than the smallest model in the range, without compromising on temperature and humidity control: 0 to 70 °C without humidity, 5 to 70 °C with active humidity control between 10 and 90 % rh, regulated via a Peltier heating and cooling system without a compressor and without conventional refrigerant.Peltier cooling for parallel test runsLike all four sizes in the HPPeco range, the HPP260eco heats and cools via a Peltier element integrated into the rear wall, operating on the heat pump principle. There is no need for a separate refrigeration circuit with conventional refrigerant. Two DIN Class A Pt100 sensors in a 4-wire configuration monitor each other and automatically take over the function of the other sensor in the event of a fault, a relevant safety detail for a chamber that typically runs continuously for several weeks at a time. The temperature setting accuracy is 0.1 °C; when exposed to light, the operating range is restricted to 15 to 40 °C.Humidity control and ControlCOCKPIT TwinDISPLAYRelative humidity can be set between 10 and 90 % rh with an accuracy of 0.5 % rh; a hot steam generator humidifies the chamber, whilst a Peltier-based cold trap dehumidifies it. The water supply is provided by an external canister with a connecting hose and a self-priming pump; a fixed water connection is not required. The HPP260eco is controlled via the ControlCOCKPIT TwinDISPLAY with two TFT colour graphic displays; test runs are managed and documented via the Ethernet interface and the AtmoCONTROL software. The SetpointWait function only starts the test time once both the temperature and humidity have reached the setpoint, which helps ensure the comparability of results when multiple formulations are running in parallel.Selection guide: Choosing the right model size in the HPPeco rangeWith a capacity of 256 litres, the HPP260eco sits between the compact entry-level model and the two larger chambers in the series:Memmert Constant-Climate Chamber HPP110eco108 litres, 560 x 480 x 400 mm, approx. 64 kg, up to 5 shelvesMemmert Constant-Climate Chamber HPP260eco256 litres, 640 x 800 x 500 mm, approx. 94 kg, up to 9 shelvesMemmert Constant-Climate Chamber HPP410eco384 litres, 640 x 1,200 x 500 mm, approx. 134 kg, up to 14 shelvesMemmert Constant-Climate Chamber HPP750eco749 litres, 1,040 x 1,200 x 600 mm, approx. 197 kg, up to 14 shelvesIf 9 shelves are consistently insufficient for the planned test programmes, it is worth considering the Memmert HPP410eco constant-climate chamber with a capacity of 384 litres and 14 shelves. On the other hand, if you only test individual batches occasionally, the more compact Memmert HPP110eco constant climate chamber is often the more cost-effective solution; technically, the four models differ mainly in volume, dimensions, weight and connected load. You can find an overview of the entire Memmert range of climate chambers and incubators in the Climate Chambers & Incubators category.Choosing between the HPPeco and the ICH110?For test programmes that also require temperatures below 0 °C or compressor-based cooling with automatic defrosting, the Memmert ICH110 climate chamber is the suitable alternative, although, at 108 litres, it falls into a smaller volume class than the HPP260eco. The ICH110 covers a range from -10 to +60 °C and uses the CFC-free R290 refrigerant; however, its connected load of around 1,350 W is significantly higher than the HPP260eco’s approximately 420 W. As long as the test range is between 0 and 70 °C, the Peltier technology of the HPP260eco remains the more energy-efficient choice.Installation, water connection and disposalA minimum distance of 15 cm from the wall, a minimum distance of 20 cm from the ceiling and a minimum distance of 5 cm from the side must be maintained; the unit may be installed at altitudes of up to 2,000 m above sea level at ambient temperatures of 16 to 40 °C and a maximum relative humidity of 70 %, non-condensing. The supplied water canister with connecting hose supplies the humidity control system; a fixed water connection in the installation room is not required. For disposal as waste electrical and electronic equipment, Memmert is registered with the Stiftung Elektro-Altgeräte Register (Stiftung EAR) under WEEE registration number DE 66812464.Which equipment for which test purposeFor validated, documented test runs, a USB-to-Ethernet adapter is suitable in combination with AtmoCONTROL or myChamber software licences; according to the manufacturer, an FDA-compliant version for 21 CFR Part 11 environments is available on request. Where several test series are running in parallel with different user groups, a lockable door and a USB user ID stick can be added to the TwinDISPLAY. For unattended runs, a potential-free contact for connection to a central control system and a MobileALERT SMS alert system are available as options. For installation, a castor frame with a supply air filter, levelling feet and a levelling or mobile base frame are also available, along with accessories for the water supply.Typical applicationsWith an internal volume of 256 litres and up to 9 shelves, the Memmert HPP260eco constant-climate chamber is suitable for laboratories that test multiple formulations or batches in parallel under controlled ICH conditions.Parallel stability studies of several active ingredient batches in accordance with ICH Q1AStability testing for cosmetic and food formulations during ongoing developmentMaterial testing in industrial quality assurance involving a large volume of samplesEnvironmental testing from freezing point upwards in research and developmentFrequently asked questions about the Memmert HPP260eco constant-climate chamberWhat temperature and humidity range does the HPP260eco cover?Depending on the operating mode, 0 to 70 °C without humidity or 5 to 70 °C with active humidity control between 10 and 90 % rh; when light exposure is applied, the operating range is restricted to 15 to 40 °C.Does the chamber require a fixed water connection?No. Humidity is supplied via the water canister supplied with the unit, which includes a connection hose and a self-priming pump.How many samples can fit into the HPP260eco?Two shelves are included as standard; a total of up to nine shelves, each with a maximum load of 20 kg, can be used, provided the total load does not exceed 200 kg.When does it make sense to switch to the HPP410eco?If you regularly require more than 9 shelves at the same time or a total load exceeding 200 kg, the HPP410eco, with a capacity of 384 litres and up to 14 shelves, offers greater capacity whilst retaining the same control technology.What distinguishes the HPP260eco from the Memmert ICH110 climate chamber?The HPP260eco cools between 0 and 70 °C using a Peltier element without a compressor or refrigerant, whilst the ICH110 operates with a compressor-based refrigeration cycle (R290) and also covers a range down to -10 °C, albeit with an internal volume of only 108 litres.What software is available for documentation and validation?The HPP260eco can be managed and read via Ethernet using the AtmoCONTROL software; for environments subject to 21 CFR Part 11, Memmert also offers, according to the manufacturer, an FDA-compliant licence option.How is calibration carried out?A calibration certificate is supplied as standard (reference values: 25 °C at 60 % rh and 40 °C at 75 % rh); in addition, three freely selectable values each for temperature and humidity can be calibrated by the user. We also arrange DAkkS-accredited calibration and IQ/OQ/PQ services.Technical detailsAdjustable temperature range (without light, without humidity)0 to 70 °CAdjustable temperature range (with humidity)5 to 70 °COperating temperature range with light15 to 40 °CTemperature setting accuracy0.1 °CTemperature sensor2x Pt100, DIN Class A, 4-wire measurementAdjustable humidity range10 to 90 % rhHumidity setting accuracy0.5 % rhInternal volume256 lInternal dimensions (W x H x D)640 x 800 x 500 mm (depth minus 32 mm for the fan)External dimensions of the housing (W x H x D)824 x 1,183 x 655 mmNet weightapprox. 94 kgConnection 230 V50/60 Hz, approx. 420 WConnection 115 V50/60 Hz, approx. 420 WShelves maximum9Shelves in scope of delivery2Max. load capacity200 kgMax. load per shelf20 kgHousing materialTextured stainless steel housing, fully galvanised sheet steel rear panelControlControlCOCKPIT TwinDISPLAY, PID microprocessor controller, 2 TFT colour graphic displaysTimer1 minute to 99 days, digital countdown timerPermissible ambient temperature16 to 40 °CPermissible relative humiditymax. 70 % rel., non-condensingMaximum installation altitude2,000 mMarkingsCE, EAC, UL marksScope of delivery1x Memmert Constant-Climate Chamber HPP260ecoStandard factory calibration certificate (25 °C / 60 % rh, 40 °C / 75 % rh)Fully insulated stainless steel door with 2-point locking (compression door lock)Inner glass doorMoisture-tight silicone feed-through (internal diameter 18 mm) with silicone plug2x stainless steel grid shelf, electropolishedWater canister including connection hoseRegulatory informationThe Memmert HPP260eco constant-climate chamber is registered with the Stiftung Elektro-Altgeräte Register (Stiftung EAR) under WEEE registration number DE 66812464.Installation in a wall openingFor fixed installation in a wall opening, Memmert offers a flush-fit unit. It covers the gap between the unit and the wall opening with stainless steel and is available with air slots (B29738) or without air slots (B29739). According to Memmert, the installation situation must be clarified technically beforehand. The flush-fit unit is therefore available on request through our procurement service.Individual requirements & procurement serviceFor the HPP260eco, the following are available, amongst other things: a castor frame with supply air filter, levelling feet, a levelling or mobile base frame, and additional accessories relating to the water supply. For data acquisition, a USB-Ethernet adapter and AtmoCONTROL and myChamber software licences are available; according to the manufacturer, FDA-compliant licences are also available. In addition, we arrange calibration, IQ/OQ/PQ and maintenance services, some of which are DAkkS-accredited. Do you require any of these accessories, a special configuration or assistance in selecting the appropriate size for your application? Through our procurement service, we will be happy to assist you with procurement and configuration.

Manufacturer's RRP: €10,761.00