Skip to main content Skip to search Skip to main navigation

Memmert holder for water canister B62010 for ICH climate chamber, sizes 110 and 260

ⓘ  This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.

Product information "Memmert holder for water canister B62010 for ICH climate chamber, sizes 110 and 260"

The holder B62010 is intended for a water canister of 2.5 litres and is mounted on the rear wall of the unit. For size 750 it is part of the standard equipment of the ICH climate chamber. Here it is listed for sizes 110 and 260. The size corresponds to the number in the unit name, for example ICH110 or ICH260.

According to Memmert, a hot steam generator humidifies the interior and evaporates water from a canister in metered amounts for this purpose. The table shows the compatible models.

Typical applications

Examples in the compatible units:

  • Stability testing of pharmaceutical products according to ICH, WHO, EMA and ASEAN requirements, for example in the ICH110
  • Stability tests for cosmetic products with temperature requirements below 0 °C, for example in the ICH110
  • Stability testing according to ICH and GMP, for example in the ICH260

Suitable for

ModelSizeInterior volume (l)
ICH110110108
ICH260260256

Technical details

Mountingon the rear wall of the unit
Water canister2.5 litres

Scope of delivery

  • 1 holder for water canister (2.5 litres)

Individual requirements & procurement service

For water canisters and for questions about compatibility with units not listed in the table, our procurement service accepts enquiries.

Skip product gallery

Fits

Topseller
Memmert climate chamber ICH110, 108 litres, humidity control 10 to 80 % rh
Memmert climate chamber ICH110, 108 litres, humidity control 10 to 80 % rh
Manufacturer number: ICH110

Anyone who needs to carry out stability tests not only at moderate temperatures but also at temperatures around and below freezing can rarely avoid a compressor-based climate chamber. With an internal volume of 108 litres, the Memmert ICH110 climate chamber covers a temperature range from -10 to +60 °C and is, according to the manufacturer, designed for stability testing in accordance with ICH, WHO, EMA and ASEAN guidelines, as well as for test environments with GMP, GLP and GCCP requirements; it is controlled via a CFC-free cooling/heating system using the refrigerant R290.Forced air circulation with an air-jacket temperature control system instead of PeltierUnlike the Peltier-cooled HPPeco chambers, the ICH110 operates with an air turbine that can be electronically controlled in 10 % increments and an air-jacket temperature control system that gently distributes heat around the interior without the test material being directly affected by an evaporator. Cooling is provided by an energy-saving, CFC-free cooling/heating system using the refrigerant R290, whilst a highly efficient automatic defrost system prevents icing during continuous operation. Without humidity, the operating range extends from -10 to +60 °C; however, Memmert expressly points out that the cabinet is not intended for long-term storage at sub-zero temperatures and that the glass door may ice up during continuous operation in the sub-zero range. With humidity and/or light, the operating range is restricted to +10 to +60 °C.Humidity control and ControlCOCKPIT TwinDISPLAYRelative humidity can be actively controlled between 10 and 80 % rh, with a display resolution of 0.1 % and a setting accuracy of 0.5 %. Humidification is provided by a hot steam generator, supplied via an external water canister with a connecting hose and a self-priming pump; a fixed water connection is not required. Two DIN Class A Pt100 sensors in a 4-wire configuration monitor each other and automatically take over the function of the other sensor in the event of a fault. The ICH110 is operated via the ControlCOCKPIT TwinDISPLAY with two TFT colour graphic displays, and data is recorded via Ethernet or USB using the AtmoCONTROL software. Selectable temperature-humidity combinations are based on the operating range diagram in the data sheet; continuous, condensation-free operation is possible only within these combinations. You can find an overview of the entire Memmert range of climate chambers and incubators in the Climate Chambers & Incubators category.Comparison: ICH110 or HPP110eco constant climate chamber?In the same 108-litre volume class, Memmert offers the Memmert HPP110eco constant climate chamber as a Peltier-cooled alternative without a compressor or conventional refrigerant. The HPP110eco covers a temperature range of 0 to 70 °C, manages with a connected load of around 420 W and does not need an automatic defrost function; however, its temperature range does not extend into sub-zero temperatures. Those running test programmes at temperatures below 0 °C, or who prefer compressor-based cooling with defined defrost cycles, are better served by the ICH110 with its higher connected load of around 1,350 W.Installation, water connection and disposalA minimum clearance of 15 cm from the wall, a minimum clearance of 20 cm from the ceiling and a minimum clearance of 5 cm at the sides must be maintained. Unlike the HPPeco range, the permissible ambient temperature for the ICH110 is 15 to 28 °C, with a restricted temperature range up to 34 °C, at a maximum relative humidity of 70 % (non-condensing), and a permissible installation altitude of up to 2,000 m above sea level. The supplied water canister with connecting hose provides the water supply for humidity control; a fixed water connection in the installation room is not required. For disposal as waste electrical and electronic equipment, Memmert is registered with the Stiftung Elektro-Altgeräte Register (Stiftung EAR) under WEEE registration number DE 66812464.Which equipment for which test purposeFor documented, validatable test runs, a USB-to-Ethernet adapter is recommended, together with AtmoCONTROL or myChamber software licences, which according to the manufacturer can be FDA-compliant for 21 CFR Part 11 environments if required. If the cabinet is operated unattended, a dry contact for the building management system, a MobileALERT SMS alert system and an additional Pt100 sensor with its own excess temperature protection can be fitted. Where several user groups work on the unit, a lockable door and a USB user ID stick for the TwinDISPLAY are available as options; for monitoring the air turbine, fan speed monitoring is also available.Typical applicationsWith an operating range of -10 to +60 °C and active humidity control between 10 and 80 % rh, the Memmert ICH110 climate chamber is designed for test programmes with explicit reference to standards.Stability testing of pharmaceutical products in accordance with ICH, WHO, EMA and ASEAN guidelinesTest environments with GMP and GLP requirements in quality control (according to the manufacturer)Test procedures with GCCP requirements in clinical research (according to the manufacturer)Stability testing of cosmetic products with temperature requirements below 0 °CFrequently asked questions about the Memmert ICH110 climate chamberWhich testing standards is the ICH110 designed to meet?According to the manufacturer, the ICH110 is designed for stability testing in accordance with ICH, WHO, EMA and ASEAN standards, as well as for test environments with GMP, GLP and GCCP requirements; however, the data sheet does not specify individual standard numbers.How does the ICH110 differ from the HPP110eco constant climate chamber?The ICH110 uses compressor-based cooling with the refrigerant R290 and covers a temperature range of -10 to +60 °C, whilst the HPP110eco operates using a Peltier element without a compressor or refrigerant, covering a range of 0 to 70 °C.Can the ICH110 be operated continuously at sub-zero temperatures?No, according to the manufacturer’s specifications, the cabinet is not intended for long-term storage at sub-zero temperatures; during continuous operation below freezing point, the glass door may become iced up.What humidity range can the ICH110 control?Actively between 10 and 80 % RH, with a setting accuracy of 0.5 % and a display resolution of 0.1 %.How many samples will fit in the ICH110?Two shelves are included as standard; a total of up to five shelves, each with a maximum load of 20 kg, can be fitted, with the total load not exceeding 150 kg.How is calibration carried out?A calibration certificate is supplied as standard (reference values: 10 °C and 37 °C, 60 % RH at 30 °C); in addition, you can calibrate three freely selectable values for temperature and humidity yourself. We also arrange DAkkS-accredited calibration and IQ/OQ/PQ services.What is included in the scope of delivery?Factory calibration certificate, fully insulated stainless steel door with 2-point locking, inner glass door, humidity-tight silicone grommet, 2 electropolished stainless steel grid shelves, and a water canister with connecting hose.Technical detailsAdjustable temperature range-10 to 60 °COperating temperature range without humidity-10 to 60 °C (not suitable for long-term storage at sub-zero temperatures)Operating temperature range with humidity/light10 to 60 °CTemperature setting accuracy0.1 °CTemperature sensor2x Pt100, DIN Class A, 4-wire measurementAdjustable humidity range10 to 80 % rhHumidity display resolution0.1 %Humidity setting accuracy0.5 %Internal volume108 lInternal dimensions (W x H x D)560 x 480 x 400 mm (depth minus 33 mm for the fan)External dimensions of the housing (W x H x D)745 x 1,233 x 585 mmNet weightapprox. 109 kgConnection 230 V50/60 Hz, approx. 1,350 WConnection 115 V50/60 Hz, approx. 1,350 WMaximum number of shelves5Shelves included in the scope of delivery2Max. load on unit150 kgMax. load per shelf20 kgHousing materialTextured stainless steel housing, fully galvanised sheet steel rear panelRefrigerantR290, CFC-freeControlControlCOCKPIT TwinDISPLAY, PID microprocessor controller, 2 TFT colour graphic displaysTimer1 minute to 99 days, digital countdown timerPermissible ambient temperature15 to 28 °C (limited to 34 °C)Permissible relative humiditymax. 70 % rel., non-condensingMaximum installation altitude2,000 mCountry of originFederal Republic of GermanyMarkingsCE, EAC, UL test markScope of delivery1x Memmert ICH110 climate chamberFactory calibration certificate (10 °C and 37 °C, 60 % rh at 30 °C)Fully insulated stainless steel door with 2-point locking mechanism (compression door lock)Inner glass doorMoisture-tight silicone feed-through (internal diameter 40 mm) with silicone plug2x stainless steel grid shelves, electropolishedWater canister including connection hoseRegulatory informationThe Memmert ICH110 climate chamber is registered with the Stiftung Elektro-Altgeräte Register (Stiftung EAR) under WEEE registration number DE 66812464.Individual requirements & procurement serviceOptions available for the ICH110 include fan speed monitoring, an additional Pt100 sensor with its own excess temperature protection, and a lockable door. For data acquisition, a USB-to-Ethernet adapter as well as AtmoCONTROL and myChamber software licences are available; according to the manufacturer, FDA-compliant licences are also available. In addition, we arrange calibration, IQ/OQ/PQ and maintenance services, including those accredited by DAkkS. Do you require any of these accessories, a special configuration or assistance in selecting the right size for your application? Through our procurement service, we will be happy to assist you with procurement and configuration.

Manufacturer's RRP: €8,709.00
Memmert climate chamber ICH260, 256 l, -10 to +60 °C, 10 to 80 % rh
Memmert climate chamber ICH260, 256 l, -10 to +60 °C, 10 to 80 % rh
Manufacturer number: ICH260

The Memmert climate chamber ICH260 has 256 litres of interior and is the middle one of the three ICH sizes. It cools with a compressor, controls temperature from -10 to +60 °C and actively controls humidity from 10 to 80 % rh, with humidification and dehumidification. Operation is via the ControlCOCKPIT TwinDISPLAY. The unit stands mobile on castors, and the external dimensions are 824 x 1,552 x 685 mm (W x H x D).Compressor cooling and air jacket temperature controlCooling and heating is by a compressor system that works with the refrigerant R290 (propane) and is CFC-free. An automatic defrost is included. The interior is temperature-controlled via an air jacket system, and the thermal jacket is separated from the interior, so that no evaporator-related drying out of the material occurs. An electronically controllable air turbine can be set in 10 % steps.Temperature and humidityWithout humidity, the working range extends from -10 °C to +60 °C, with humidity from +10 °C to +60 °C. At sub-zero temperatures the chamber is not suitable for permanent storage, and in continuous operation the glass door can ice up. Humidity is displayed with a resolution of 0.1 % and can be set to an accuracy of 0.5 %, temperature to 0.1 °C. A hot steam generator humidifies, and humidity is supplied with distilled water from an external container via a self-priming pump, with a water canister with connection hose included. Alternatively there is a central water supply for the domestic water connection, with filter cartridges (ZWVR6) or without (ZWVR7). Without filter cartridges, only demineralised, fully deionised water with 5 to 10 μS/cm conductivity and a pH value between 5 and 7 is to be used.Interior, loading and installationThe stainless steel interior measures 640 x 800 x 500 mm (W x H x D), and the depth is reduced by 33 mm for the fan. Two stainless steel grid shelves are included, and up to 9 shelves are possible, with 20 kg each and 200 kg total load. The housing outside is made of textured stainless steel, the rear wall is fully galvanised, and the net weight is approx. 160 kg. The chamber is connected with 230 V, 50/60 Hz and draws approx. 1,350 W. The environment may be 15 to 28 °C warm, with a restricted temperature range up to 34 °C, at a maximum of 70 % rel. humidity, non-condensing. Installation altitude up to 2,000 m above sea level.Control and safetyThe TwinDISPLAY works with two Pt100 sensors of DIN class A in 4-wire measurement, which monitor each other and take over the function of the other in the event of a fault. SetpointWAIT starts the process time only when the setpoint temperature is reached, and the countdown clock runs from 1 minute to 99 days. Programs are transferred via Ethernet or USB with the AtmoCONTROL software, and the program sequence remains saved in the event of a power failure. A mechanical temperature limiter of protection class 1 according to DIN 12880 switches the heating off at approx. 10 °C above the maximum chamber temperature. On the display, an adjustable temperature monitor of protection class 3.3 or an adjustable temperature limiter of protection class 2 can also be selected. AutoSAFETY switches the heating off when exceeded and the cooling unit when fallen below, and a self-diagnosis system as well as visual and acoustic alarm are added.Selection guide: ICH260, other ICH sizes and the HPPecoThe ICH110 has 108 l at the same temperature and humidity ranges, and the ICH750 749 l with up to 14 shelves and 30 kg per shelf. The ICH260 sits in between with up to 9 shelves (ICH110: 5), and 20 kg per shelf are permitted as on the ICH110. Compared with the Peltier chamber HPP260eco, which also has 256 l, the ranges differ: the HPP260eco sets 0 to +70 °C without humidity, and with humidity +5 to +70 °C at up to 90 % rh. The ICH260 sets -10 to +60 °C, and with humidity it works from +10 to +60 °C at up to 80 % rh.Typical applicationsThe ICH260 is a climate chamber for stability testing, including within these frameworks:Stability testing according to ICH and GMPStability testing according to WHO, EMA, ASEAN, GLP and GCCPTechnical detailsSetting temperature range-10 to +60 °CWorking temperature range without humidity-10 °C to +60 °CWorking temperature range with humidity+10 °C to +60 °CTemperature setting accuracy0.1 °CHumidity range10 to 80 % rh, active humidification and dehumidificationHumidity display resolution / setting accuracy0.1 % / 0.5 %Cooling/heating systemCompressor, refrigerant R290 (propane), CFC-free, automatic defrostTemperature controlAir jacket temperature control system, air turbine electronically controllable in 10 % stepsTemperature sensor2x Pt100, DIN class A, 4-wire measurement, mutual monitoringControlControlCOCKPIT TwinDISPLAY, adaptive PID microprocessor controller, 2x TFT colour graphic displayInternal volume256 lInternal dimensions (W x H x D)640 x 800 x 500 mm (depth less 33 mm for fan)External dimensions (W x H x D)824 x 1,552 x 685 mm (depth plus 56 mm door handle)Shelves maximum / in scope of delivery9 / 2Max. load unit / per shelf200 kg / 20 kgInstallationmobile and lockable, on castorsConnection230 V, 50/60 Hz, approx. 1,350 WPermissible environment15 to 28 °C (up to 34 °C with restricted temperature range), max. 70 % non-condensing, max. 2,000 m above sea levelWeight net / gross (carton)approx. 160 kg / approx. 217 kgDimensions with carton (W x H x D)930 x 1,760 x 930 mmMarkingCEOther sizes in the seriesThe ICH climate chamber is available in three sizes from 108 to 749 litres, all with TwinDISPLAY:ModelInternal volumeSetting temperatureHumidity rangeICH110108 l-10 to +60 °C10 to 80 % rhICH260 (this page)256 l-10 to +60 °C10 to 80 % rhICH750749 l-10 to +60 °C10 to 80 % rhScope of delivery1x Memmert climate chamber ICH260Factory calibration certificate (+10 °C and +37 °C, 60 % rh at +30 °C)Inner glass doors and fully insulated stainless steel doors with 2-point locking (compression door lock)Humidity-tight silicone feedthrough at the back, inner diameter 40 mm, with silicone sealing plug2x stainless steel grid shelf, electropolishedWater canister with connection hoseRegulatory informationThe unit is an electrical device within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer Memmert GmbH + Co. KG is DE 66812464. Notes on returning old appliances can be found on our page Environment and disposal. The climate chamber cools with the refrigerant R290 (propane).Individual requirements and procurement serviceAvailable as factory options for the ICH260 are, among others, an interior socket, lateral feedthroughs with 23 mm and a silicone feedthrough with 40 mm inner diameter, 4-20 mA current interfaces for temperature, humidity and up to three Pt100 sensors, a fan speed monitoring with heating shutdown, a compressed air drying, a lockable door, a potential-free contact for fault messages, a door-open detection and MobileALERT by SMS. Accessories include stainless steel grid shelves, perforated trays and drip trays, a USB-Ethernet adapter, an Ethernet cable, the USB user ID stick, the FDA basic licence for AtmoCONTROL FDA and an external measuring device for temperature and humidity. Calibrations, IQ/OQ documents, on-site qualifications and maintenance contracts can be requested. For individual requirements, we will advise you personally.