WTW SenTix 20 plastic pH electrode with gel electrolyte, S7 connector, 103630

ⓘ  This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.

Product information "WTW SenTix 20 plastic pH electrode with gel electrolyte, S7 connector, 103630"

Measuring pH in wastewater, aquariums or swimming pools should not depend on a refilling routine. The WTW SenTix 20 features a plastic shaft and a gel electrolyte which, according to WTW, is not refilled. The electrode is low-maintenance. The pH measuring range extends from 0 to 14, and it can be used at sample temperatures of 0 to 80 °C.

Gel electrolyte and fibre junction

The shaft is made of PPE/PS, is 120 mm long and has a diameter of 12 mm. The membrane is cylindrical; its resistance at 25 °C is less than 1 GΩ. According to WTW, the fibre junction prevents blockages. There is no need to monitor or top up the electrolyte level. If the electrolyte is meant to be refillable, the SenTix 51 and 52 with liquid electrolyte and a ceramic junction in a plastic shaft are the alternative.

Connection and temperature measurement

The SenTix 20 has an S7 plug head and is supplied without a cable. Depending on the measuring instrument, one of the WTW connection cables AS/DIN (1 m, 108110), AS/DIN-3 (3 m, 108112) or AS/BNC (1 m, 108114) fits. If there is no built-in sensor, the temperature is entered on the measuring instrument or measured using an external sensor. The gel electrodes in this range differ in plug, cable length and temperature sensor. You should therefore establish which input the measuring instrument has before placing your order.

Typical applications according to WTW

When taking samples from water bodies, at the edge of a pool or from a wastewater pipe, what counts is an electrode that is quickly ready for use. WTW names the following media for this series:

  • Electroplating effluent, industrial wastewater and wastewater in general
  • Aquarium and swimming pool water
  • Groundwater, lake water, surface water and seawater
  • Household cleaners

Storage and care

Before the first measurement, remove the wetting cap; gas bubbles behind the membrane can be removed by shaking. For short measurement breaks, immerse the electrode in reference electrolyte (3 mol/l KCl, Ag+-free). Overnight and for longer periods, it stays in the wetting cap, filled with the same electrolyte. According to WTW, storing the electrode dry or in deionised water can cause permanent damage. If the cap has dried out, the electrode needs at least 24 hours in reference electrolyte. As with any pH electrode, strong acids and alkalis, hydrofluoric acid, organic solvents, oils, fats and proteins shorten its service life.

Technical details

TypepH electrode, analogue, gel electrolyte
Shaft materialPlastic (PPE/PS)
Shaft length / Shaft diameter120 mm / 12 mm
ElectrolyteGel, non-refillable
Reference systemSilver/silver chloride
JunctionFibre
Membrane shapeCylindrical
pH measuring range0 to 14
Temperature range0 to 80 °C
Membrane resistance< 1 GΩ at 25 °C
Temperature sensorNone
ConnectionS7 plug head
CableNo cable

Scope of delivery

  • 1 WTW SenTix 20 pH electrode with wetting cap
  • No connection cable in the scope of delivery

Accessories and procurement service

Connection cables (AS/DIN, AS/DIN-3, AS/BNC), reference electrolyte KCl 3 mol/l for the wetting cap and buffer solutions for calibration are also available. Enquiries regarding other SenTix models or larger quantities go through our procurement service.