WTW SenTix Ag silver electrode for argentometry, liquid electrolyte, S7 plug-in head, 103664
€293.00
% Manufacturer's RRP: €325.00 9% below manufacturer's RRP
- Silver electrode made of glass, 120 mm long, 12 mm in diameter
- Silver cylinder cap as a measuring element
- Reference electrolyte 2 mol/l KNO3 with 0.001 mol/l KCl, refillable
- Ceramic junction
- Temperature range -5 to 100 °C
- S7 plug head, connection cable selectable separately
- For argentometry in the laboratory
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "WTW SenTix Ag silver electrode for argentometry, liquid electrolyte, S7 plug-in head, 103664"
The WTW SenTix Ag is a silver electrode made of glass with an S7 plug head for laboratory use. WTW lists it as a special redox electrode for argentometry. The shaft is 120 mm long and has a diameter of 12 mm; the junction is made of ceramic. The reference electrolyte can be refilled.
Measuring element and reference system
The measuring element is a silver cylinder cap, the reference electrolyte is 2 mol/l KNO3 with 0.001 mol/l KCl. The measured quantity is the voltage in mV; this electrode does not have a pH measuring range. The electrode can be used at sample temperatures of -5 to 100 °C. A temperature sensor is not fitted. The refill opening remains open during measurement. For redox measurements, WTW offers the SenTix ORP in the same shaft.
Dedicated electrolyte for the silver electrode
The SenTix Ag does not use the KCl electrolyte of the pH and redox electrodes. WTW specifies the reference electrolyte ELY/ORP/AG (250 ml, 109735) for this electrode. According to the instructions, it is refilled with a suitable pipette. The electrolyte level is at least 2 cm above the sample level, so it needs to be checked before each measurement.
Typical applications according to WTW
- Argentometry in the laboratory
- Precipitation titrations using silver ions, for example the determination of chloride
Connection, storage and care
Before the first measurement, remove the wetting cap; gas bubbles behind the membrane can be removed by shaking. The electrode has an S7 plug head and is supplied without a cable. Depending on the measuring instrument, one of the WTW connection cables AS/DIN (1 m, 108110), AS/DIN-3 (3 m, 108112) or AS/BNC (1 m, 108114) fits. During short measurement breaks, the electrode is immersed in reference electrolyte. Overnight and for longer periods, it stays in the wetting cap, filled with reference electrolyte, with the refill opening closed. According to WTW, storing it dry or in deionised water can cause permanent damage. If the cap has dried out, the electrode needs at least 24 hours in reference electrolyte.
Technical details
| Type | silver electrode, analogue |
| Measuring element | silver cylinder cap |
| Measured quantity | Voltage in mV |
| Shaft material | Glass |
| Shaft length / shaft diameter | 120 mm / 12 mm |
| Reference electrolyte | 2 mol/l KNO3 with 0.001 mol/l KCl, refillable |
| Junction | Ceramic |
| Temperature range | -5 to 100 °C |
| Temperature sensor | None |
| Connection | S7 plug head |
| Cable | No cable |
Scope of delivery
- 1 WTW SenTix Ag electrode with wetting cap
- No connection cable in the scope of delivery
Accessories and procurement service
Connection cables (AS/DIN, AS/DIN-3, AS/BNC) and the reference electrolyte ELY/ORP/AG are also available. Enquiries regarding other SenTix electrodes go through the procurement service.