The WTW SenTix Ag is a silver electrode made of glass with an S7 plug head for laboratory use. WTW lists it as a special redox electrode for argentometry. The shaft is 120 mm long and has a diameter of 12 mm; the junction is made of ceramic. The reference electrolyte can be refilled.

Measuring element and reference system

The measuring element is a silver cylinder cap, the reference electrolyte is 2 mol/l KNO3 with 0.001 mol/l KCl. The measured quantity is the voltage in mV; this electrode does not have a pH measuring range. The electrode can be used at sample temperatures of -5 to 100 °C. A temperature sensor is not fitted. The refill opening remains open during measurement. For redox measurements, WTW offers the SenTix ORP in the same shaft.

Dedicated electrolyte for the silver electrode

The SenTix Ag does not use the KCl electrolyte of the pH and redox electrodes. WTW specifies the reference electrolyte ELY/ORP/AG (250 ml, 109735) for this electrode. According to the instructions, it is refilled with a suitable pipette. The electrolyte level is at least 2 cm above the sample level, so it needs to be checked before each measurement.

Typical applications according to WTW

  • Argentometry in the laboratory
  • Precipitation titrations using silver ions, for example the determination of chloride

Connection, storage and care

Before the first measurement, remove the wetting cap; gas bubbles behind the membrane can be removed by shaking. The electrode has an S7 plug head and is supplied without a cable. Depending on the measuring instrument, one of the WTW connection cables AS/DIN (1 m, 108110), AS/DIN-3 (3 m, 108112) or AS/BNC (1 m, 108114) fits. During short measurement breaks, the electrode is immersed in reference electrolyte. Overnight and for longer periods, it stays in the wetting cap, filled with reference electrolyte, with the refill opening closed. According to WTW, storing it dry or in deionised water can cause permanent damage. If the cap has dried out, the electrode needs at least 24 hours in reference electrolyte.

Technical details

Typesilver electrode, analogue
Measuring elementsilver cylinder cap
Measured quantityVoltage in mV
Shaft materialGlass
Shaft length / shaft diameter120 mm / 12 mm
Reference electrolyte2 mol/l KNO3 with 0.001 mol/l KCl, refillable
JunctionCeramic
Temperature range-5 to 100 °C
Temperature sensorNone
ConnectionS7 plug head
CableNo cable

Scope of delivery

  • 1 WTW SenTix Ag electrode with wetting cap
  • No connection cable in the scope of delivery

Accessories and procurement service

Connection cables (AS/DIN, AS/DIN-3, AS/BNC) and the reference electrolyte ELY/ORP/AG are also available. Enquiries regarding other SenTix electrodes go through the procurement service.