Skip to main content Skip to search Skip to main navigation

Binder M 115 Drying and Heating Oven with forced air circulation, 113 l, up to 300 °C, 9010-0372

Product information "Binder M 115 Drying and Heating Oven with forced air circulation, 113 l, up to 300 °C, 9010-0372"

The Binder M 115 drying oven expands the M Classic.Line series by offering greater usable volume without compromising on test accuracy. With an internal capacity of 113 litres and a temperature range from 23 °C above room temperature up to 300 °C, the unit is suitable for material testing and ageing tests where larger quantities of samples or multiple test specimens need to be processed simultaneously.

Programmable test sequences via the touchscreen

The intuitive touchscreen controller offers interval and real-time programming, allowing multi-stage temperature profiles to be stored for compliance with test standards or internal quality assurance requirements. The integrated Ethernet interface and internal data logger enable test runs to be documented and analysed without the need to connect additional external recording devices.

Rapid heating and high temperature accuracy

Thanks to APT.line technology with enhanced heating power, the M 115 achieves a spatial temperature deviation of just 1.0 ± K and a temporal deviation of 0.2 ± K at 150 °C. The heating time to 150 °C is 11 minutes. With an air change rate of 105 times per hour at 100 °C, the forced-air circulation system ensures uniform heating even when the 113-litre interior is heavily loaded.

Typical areas of application

  • Material testing and ageing tests in quality assurance and development
  • Drying of larger sample quantities and batches of laboratory glassware
  • Multi-stage temperature programmes for standardised tests
  • Heat treatment of material samples in industry

Particularly when several test specimens need to be aged or dried in parallel in quality assurance, the larger capacity of the M 115 compared to the more compact M 56 becomes apparent, without any need to compromise on heating rate or temperature accuracy.

Selection guide: choosing the right size from the M Series

With a capacity of 113 litres, the M 115 sits between the compact M 56 and the larger models, the M 260 and M 720. You can find the complete range of this series in the LT Laborhandel range of climate chambers and incubators.

ModelUseful volume, external dimensions (W x D x H), weight
M 5659 l, 560 x 596 x 622 mm, 43 kg
M 115113 l, 710 x 636 x 732 mm, 58 kg
M 260256 l, 810 x 786 x 962 mm, 86 kg
M 720735 l, 1,160 x 816 x 1,590 mm, 170 kg

If several test specimens are to be aged or dried simultaneously, but a floor-standing unit is not yet required, the M 115 is usually the most practical choice within the range.

Distinguishing feature: M or FP – depending on the level of documentation required

The M 115’s touchscreen controller, featuring an internal data logger and Ethernet interface, enables comprehensive documentation of test runs, for example for quality assurance reports in accordance with standard requirements. If this level of documentation is not required, the Binder FP 115 drying and heating oven – which is identical in construction – covers the same temperature ramp functions with a simpler controller.

Technical details

Temperature range23 °C above room temperature to 300 °C
Usable volume113 l
Spatial temperature variation (at 150 °C)1.0 ± K
Temporal temperature deviation (at 150 °C)0.2 ± K
Heating time to 150 °C11 min
Air change rate (at 100 °C)105 times/h
Energy consumption at 100 °C250 Wh/h
Energy consumption at 150 °C410 Wh/h
Sound pressure level46 dB(A)
Rated voltage230 V
Rated power2.4 kW
External dimensions (W x H x D)710 x 732 x 636 mm

Contents

  • 1x Binder M 115 drying and heating cabinet, 230 V (9010-0372)
  • Standard insert racks
  • User manual

Frequently asked questions before purchase

How accurately does the M 115 control the temperature?
At 150 °C, the M 115 achieves a spatial temperature deviation of just 1.0 ± K and a temporal deviation of 0.2 ± K.

What is the energy consumption of the M 115?
At 100 °C, energy consumption is 250 Wh/h; at 150 °C, it is 410 Wh/h.

How quickly does the M 115 heat up?
The heating time to 150 °C is 11 minutes.

What are the external dimensions of the M 115?
The external dimensions are 710 x 732 x 636 mm, with a weight of 58 kg.

Customised requirements & procurement service

Further accessories are available for the M 115, such as additional shelf grids, calibration certificates and maintenance contracts of varying scope. Do you require customised configurations, spare parts or advice on selecting the right test chamber for your application? LT Laborhandel will be happy to assist you via our procurement service.

Volume: 113 l