Skip to main content Skip to search Skip to main navigation

Brand Dispensette S Bottle-Top Dispenser, Digital, 0.1-1 ml, without Recirculation Valve, DE-M, 4600310

Product information "Brand Dispensette S Bottle-Top Dispenser, Digital, 0.1-1 ml, without Recirculation Valve, DE-M, 4600310"

Anyone in the laboratory who repeatedly needs trace additions of colour reagents in photometry wants to be able to read the volume without estimating the scale by eye. With 0.1 to 1 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 percent or nitric acid above 30 percent.

Digital counter

The digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.

Without recirculation valve

This version works without a recirculation valve. The design is therefore simpler, with one less moving part in the dispensing path. For applications where every dispensed volume goes directly into the target vessel and no return is needed, this slimmer design is sufficient.

Mounting and handling

The Dispensette S Digital is mounted directly on the stock bottle using the bottle adapter supplied, and the telescopic filling tube can be shortened to the bottle height. The mounting key is part of the scope of delivery and is needed when changing the valve or discharge tube. After fitting, the device is drawn up and dispensed into a waste container several times until there are no more air bubbles in the system, after which it is ready for use.

Media compatibility

The red standard version tolerates a wide range of reagents: concentrated acids such as phosphoric acid and sulphuric acid, concentrated alkalis, salt solutions and numerous organic solvents. Excluded are hydrofluoric acid as well as hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids. Anyone who regularly dispenses concentrated hydrochloric or nitric acid should choose the yellow Dispensette S Organic; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.

Autoclavability

The complete device is autoclavable: sterilisation to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours of cooling time in the closed device. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.

Distinction within the Dispensette S standard series

The three versions of the Dispensette S standard series differ in the way the volume is set, not in accuracy. Anyone who changes more often between volumes within the stated range gets on fastest with the Digital display. Anyone who is comfortable with a mechanical scale saves on purchase cost with the Analog version. And anyone who permanently needs only one volume gets by most easily with the Fix version.

Accuracy and graduation

Accuracy is 0.5 %/5 µl, the coefficient of variation figure 0.1 %/1 µl, the graduation 0.005 ml. These values apply to all volumes set within the range 0.1 to 1 ml and were determined according to the general test procedure for piston-stroke devices.

Frequently asked questions

Can the counter be reset to zero?
Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.

Which bottle sizes fit the Dispensette S Digital?
According to the accessories table, the adapters GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.

For which work step is the volume range 0.1 to 1 ml intended?
Typical uses include the addition of very small amounts of reagent in serial analysis, the range thus covers an application window in which a smaller or larger volume of the Digital series would no longer fit.

Typical applications

  • Trace additions of colour reagents in photometry
  • Indicator drops in titration
  • Addition of very small amounts of reagent in serial analysis

Technical details

LineBrand Dispensette S, Digital
Volume0.1 to 1 ml
Graduation0.005 ml
Accuracy0.5 %/5 µl
Coefficient of variation0.1 %/1 µl
Recirculation valveno
Media compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 percent, nitric acid above 30 percent
Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapter
AutoclavabilitySterilisation to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours of cooling time in the closed device
MarkingDE-M
Manufacturer article no.4600310

Scope of delivery

  • Bottle-top dispenser for GL45 threaded bottles
  • Discharge tube
  • Telescopic filling tube
  • Mounting key
  • Bottle adapter matching the volume
  • Quality certificate
  • Operating manual

Individual requirements and procurement service

For additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, LT Laborhandel provides support through its own procurement service at lt-laborhandel.com/service.

Display type: Digital
Operation: mechanical
Recirculation valve: without recirculation valve
Volume range: 0.1 ml - 1 ml
Volume setting: variable