Bottle-mounted dispenser
Bottle-top dispensers dispense liquids directly from the reagent bottle, precisely and without repeated pipetting. LT Laborhandel offers the BRAND Dispensette S in analogue and digital versions, with and without a recirculation valve (RDV), equally suitable for organic and aqueous solutions. You can find further equipment in the Liquid Handling category. We’d be happy to discuss which model is best suited to your application.
Brand Dispensette S Bottle-Top Dispenser, Digital, 2.5-25 ml, with Recirculation Valve, DE-M, 4600351
Anyone in the laboratory who repeatedly needs to prepare larger quantities of buffer wants to be able to read the volume without estimating the scale by eye. With 2.5 to 25 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.Accuracy and graduationAccuracy is 0.5 %/125 µl, the coefficient of variation figure 0.1 %/25 µl, the graduation 0.1 ml. These values apply to all volumes set within the range 2.5 to 25 ml and were determined according to the general test procedure for piston-stroke devices.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Recirculation functionThis version has a recirculation valve. Excess liquid can thus be returned to the stock bottle without opening the discharge tube or removing the bottle. This is practical with expensive or hazardous reagents, for example when a calibration check needs several back-weighings or when too much volume was dispensed by mistake.Mounting and handlingThe Dispensette S Digital is mounted directly on the stock bottle using the bottle adapter supplied, and the telescopic filling tube can be shortened to the bottle height. The mounting key is part of the scope of delivery and is needed when changing the valve or discharge tube. After fitting, the device is drawn up and dispensed into a waste container several times until there are no more air bubbles in the system, after which it is ready for use.Media compatibilityThe range of media includes aggressive reagents, highly concentrated acids such as phosphoric or sulphuric acid, salt solutions and many organic solvents. By contrast, hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids must not be dispensed. The yellow Organic variant is intended for concentrated hydrochloric and nitric acid, THF and trifluoroacetic acid; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time around 2 hours in the closed autoclave. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Distinction within the Dispensette S standard seriesThe three versions of the Dispensette S standard series differ in the way the volume is set, not in accuracy. Anyone who changes more often between volumes within the stated range gets on fastest with the Digital display. Anyone who is comfortable with a mechanical scale saves on purchase cost with the Analog version. And anyone who permanently needs only one volume gets by most easily with the Fix version.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 2.5 to 25 ml intended?Typical uses include reagent addition for larger sample series, this volume range is intended for such applications.Typical applicationsPreparing larger quantities of bufferDilution series in the ml rangeReagent addition for larger sample seriesTechnical detailsLineBrand Dispensette S, DigitalVolume2.5 to 25 mlGraduation0.1 mlAccuracy0.5 %/125 µlCoefficient of variation0.1 %/25 µlRecirculation valveyesMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavability121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time around 2 hours in the closed autoclaveMarkingDE-MManufacturer article no.4600351Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tube including recirculation tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support via our procurement service.
Brand Dispensette S Bottle-Top Dispenser, Digital, 5-50 ml, without Recirculation Valve, DE-M, 4600360
Anyone who repeatedly has to portion media in the microbiology laboratory wants to be able to read the volume without estimating the scale by eye. With 5 to 50 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.Without recirculation valveThis version works without a recirculation valve. The design is therefore simpler, with one less moving part in the dispensing path. For applications where every dispensed volume goes directly into the target vessel and no return is needed, this slimmer design is sufficient.Mounting and handlingThe bottle adapter from the scope of delivery is screwed onto the stock bottle, and the telescopic filling tube can be shortened to the bottle height. Before first use, the device is drawn up and dispensed into a waste container several times until the system is free of air bubbles. The mounting key is needed later when changing the valve or discharge tube.Media compatibilitySuitable for aggressive reagents, concentrated alkalis and acids such as phosphoric acid or sulphuric acid, salt solutions and many organic solvents. Not suitable for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids. The yellow Dispensette S Organic is intended for concentrated hydrochloric and nitric acid, THF and trifluoroacetic acid; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: steam sterilisation at 121 °C and 2 bar gauge pressure for at least 15 minutes according to DIN EN 285, followed by about 2 hours of cooling time in the closed autoclave. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Distinction within the Dispensette S standard seriesWithin the Dispensette S standard series, Digital, Analog and Fix differ mainly in volume setting. Digital shows the set volume on the mechanical counter and is suitable when different values are often needed within the range. Analog achieves the same accuracy via a scale on the cylinder without a counter. Fix dispenses only a single, factory-adjusted volume and thus reduces the risk of accidental changes. Anyone who constantly needs the same volume range and no variation gets by more cheaply and with simpler handling with a Fix version.Accuracy and graduationAccuracy is 0.5 %/250 µl, the coefficient of variation 0.1 %/50 µl, the graduation 0.2 ml. These values apply to all volumes set within the range 5 to 50 ml and were determined according to the general test procedure for piston-stroke devices.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 5 to 50 ml intended?Typical uses include the preparation of culture solutions and buffers in larger batches.Typical applicationsMedia portioning in the microbiology laboratoryFilling larger quantities of reagentPreparing culture solutions and buffers in larger batchesTechnical detailsLineBrand Dispensette S, DigitalVolume5 to 50 mlGraduation0.2 mlAccuracy0.5 %/250 µlCoefficient of variation0.1 %/50 µlRecirculation valvenoMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavabilitysteam sterilisation at 121 °C and 2 bar gauge pressure for at least 15 minutes according to DIN EN 285, followed by about 2 hours of cooling time in the closed autoclaveMarkingDE-MManufacturer article no.4600360Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support via our procurement service.
Brand Dispensette S Organic bottle-top dispenser, Analog, 1-10 ml, with recirculation valve, DE-M, 4630141
In standardised digestion procedures with concentrated nitric acid, daily venting should not cost any reagent. The Brand Dispensette S Organic Analog with recirculation valve (1 to 10 ml) returns excess volume to the stock bottle instead of discarding it via the discharge tube. At 1-10 ml the graduation is 0.2 ml, the accuracy is 0.5 %/50 µl and the coefficient of variation is 0.1 %/10 µl.Typical applicationsThe yellow colour code identifies the Organic series in the Brand range. Typical applications for 1-10 ml:Venting before standardised digestion with concentrated nitric acid, without reagent lossrecurring addition of organic solvents, with excess volume returnedfixed THF dispensing in synthesis, with refilling without lossAnalog version and selection guideThe volume is set using the volume adjustment screw with indicator arrow: loosen the screw by three quarters of a turn, slide the indicator arrow to the scale value, and tighten the screw again. Once set, the value stays until deliberately changed. Analog devices can be adjusted without tools via Easy Calibration. Matching bottle adapters for GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 are included, and the filling tube can be adjusted to 125-240 mm.With a fixed but expensive acid volume in routine work, the recirculation valve pays off when venting. For inexpensive media, the version without recirculation valve is sufficient.Materials and autoclavabilityWetted parts are made of borosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter). The device is autoclavable under the following conditions: 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclave. Tantalum as the valve spring material, together with the fluoroplastics ETFE, FEP, PFA and PTFE, makes the Organic series suitable for organic solvents and some concentrated acids, but not for alkaline solutions and salt solutions.The Dispensette S Organic is not suitable for alkaline solutions, salt solutions, carbon disulphide, explosive liquids and media that attack borosilicate glass, such as hydrofluoric acid. For alkaline solutions and salt solutions, the Dispensette S in red (standard) is the suitable series, and for trace analysis with a selectable valve spring of platinum-iridium or tantalum, the Dispensette S Trace Analysis.Assembly and changing to a different stock bottle are done with the supplied mounting key and the telescopic filling tube, which can be adjusted to the respective bottle height. The bottle adapter included in the scope of delivery fits the respective GL45-compatible thread and makes the dispenser usable regardless of the specific stock bottle.Accuracy at a glanceFor 1-10 ml: graduation 0.2 ml, accuracy 0.5 %/50 µl, coefficient of variation 0.1 %/10 µl. The DE-M marking in the product name refers to conformity assessment under German weights and measures law; it does not replace a calibration certificate.Other volumes in the Analog versionIf you need a range other than 1-10 ml, you will find it within the Analog version of the Dispensette S Organic:VolumeAccuracyMPN (without recirculation valve)0.5-5 ml0.5 %/25 µl46301302.5-25 ml0.5 %/125 µl46301505-50 ml0.5 %/250 µl463016010-100 ml0.5 %/500 µl4630170Frequently asked questionsWhat is the recirculation valve needed for?It allows the dispensing system to be vented before first use without losing any reagent: air and excess volume go back into the stock bottle via the recirculation tube instead of into waste. This is particularly relevant with expensive or environmentally relevant solvents.How is the Analog version adjusted in the 1-10 ml range?With Easy Calibration this can be done without additional tools; a changed factory adjustment is shown by a red marking.Technical detailsVersionAnalogRecirculation valveyes, incl. recirculation tubeVolume range1-10 mlGraduation0.2 mlAccuracy (A)0.5 %/50 µlCoefficient of variation (CV)0.1 %/10 µlColour codeyellow (Organic)Valve springTantalumWetted materialsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter)Autoclavableyes, 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclaveThreadGL45Adapter/filling tubeAdapters: GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40; filling tube 125-240 mm; incl. recirculation tubeScope of delivery1 Dispensette S Organic bottle-top dispenser for GL45 threaded bottlesDischarge tube with recirculation valve, including recirculation tubeTelescopic filling tubeMounting keyBottle adapter matching the volume rangeQuality certificateOperating instructionsDistinction within the Dispensette S familyYellow colour code means: suitable for organic solvents and for concentrated hydrochloric acid and nitric acid. For alkaline solutions and the other acids, the red standard Dispensette S still applies. For trace analysis with a selectable valve spring of platinum-iridium or tantalum, the Dispensette S Trace Analysis is available separately.Individual requirements & procurement serviceWe provide support via our own procurement service with suitable bottle adapters, spare parts and further volume ranges of this series.
Brand Dispensette S Bottle-Top Dispenser, Digital, 1-10 ml, with Recirculation Valve, DE-M, 4600341
Anyone in the laboratory who repeatedly needs a routine reagent addition wants to be able to read the volume without estimating the scale by eye. With 1 to 10 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.Media compatibilityThe red standard version tolerates a wide range of reagents: concentrated acids such as phosphoric acid and sulphuric acid, concentrated alkalis, salt solutions and numerous organic solvents. Excluded are hydrofluoric acid as well as hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids. Anyone who regularly dispenses concentrated hydrochloric or nitric acid should choose the yellow Dispensette S Organic; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: sterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours of cooling time in the closed device. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Distinction within the Dispensette S standard seriesWithin the Dispensette S standard series, Digital, Analog and Fix differ mainly in volume setting. Digital shows the set volume on the mechanical counter and is suitable when different values are often needed within the range. Analog achieves the same accuracy via a scale on the cylinder without a counter. Fix dispenses only a single, factory-adjusted volume and thus reduces the risk of accidental changes. Anyone who constantly needs the same volume range and no variation gets by more cheaply and with simpler handling with a Fix version.Accuracy and graduationAccuracy is 0.5 %/50 µl, the coefficient of variation figure 0.1 %/10 µl, the graduation 0.05 ml. These values apply to all volumes set within the range 1 to 10 ml and were determined according to the general test procedure for piston-stroke devices.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Recirculation functionThis version has a recirculation valve. Excess liquid can thus be returned to the stock bottle without opening the discharge tube or removing the bottle. This is practical with expensive or hazardous reagents, for example when a calibration check needs several back-weighings or when too much volume was dispensed by mistake.Mounting and handlingThe bottle adapter from the scope of delivery is screwed onto the stock bottle, and the telescopic filling tube can be shortened to the bottle height. Before first use, the device is drawn up and dispensed into a waste container several times until the system is free of air bubbles. The mounting key is needed later when changing the valve or discharge tube.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 1 to 10 ml intended?Typical uses include recurring additions in analysis series, this volume range is intended for such applications.Typical applicationsRoutine reagent addition in the laboratoryBuffer preparation in common volumesrecurring additions in analysis seriesTechnical detailsLineBrand Dispensette S, DigitalVolume1 to 10 mlGraduation0.05 mlAccuracy0.5 %/50 µlCoefficient of variation0.1 %/10 µlRecirculation valveyesMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavabilitySterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours of cooling time in the closed deviceMarkingDE-MManufacturer article no.4600341Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tube including recirculation tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support via our procurement service.
Brand seripettor bottle-top dispenser, 1-10 ml, 4720140
The seripettor 1-10 ml is a bottle-top dispenser for repeated dosing directly from the stock bottle, without the need for a pipette. The valve block with discharge tube is pre-assembled onto the GL45 thread; dosing is controlled by the stroke of the actuator.Autoclavable except for two componentsThe valve block, filling tube, discharge tube and valves are autoclavable at 121 °C, 2 bar, for at least 15 minutes according to DIN EN 285, following removal of the actuator and dosing unit. The actuator unit and dosing unit themselves are not autoclavable. For sterile batch processing, this means that the part of the dispenser in contact with the medium can be steam-sterilised without having to replace the entire device.Suitable for aqueous and mildly corrosive solutionsSuitable for aqueous solutions such as buffer solutions, detergents, anti-foaming agents, culture media, vitamin solutions and hydrogen peroxide; for agar culture media up to 60 °C; for weakly concentrated or diluted non-oxidising acids and alkalis such as caustic soda, potassium hydroxide or ammonia, as well as for polar solvents such as ethanol, methanol and acetylacetone. Hydrofluoric acid is not suitable.Error limits for the 1-10 ml rangeFor the 1-10 ml range, Brand specifies an accuracy of 1.2 % / 120 µl and a coefficient of variation of 0.2 % / 20 µl, with a graduation of 0.2 ml. This middle volume range covers most standard dosages in cell culture and buffer preparation without the need to switch between two instruments.Typical applicationsPreparation of buffer solutions and culture media in routine quantitiesDispensing agar culture media up to 60 °C directly from the stock bottleRecurring dispensing operations in cell culture with an autoclavable valve blockWorkstations with a fixed bottle size, where the dispenser remains permanently installedSelection guide: Volume and mediaWith a range of 1 to 10 ml, this stage covers most standard dispensing requirements in cell culture and buffer preparation, bridging the gap between the fine 0.2-2 ml stage and the larger 2.5-25 ml stage for culture vessels. The standard seripettor is suitable for sodium hydroxide, potassium hydroxide, ammonia and other aqueous media; hydrofluoric acid is excluded for all three ranges. Users who regularly dispense concentrated hydrochloric acid or acetone should switch to the ‘pro’ version within the same volume range.seripettor versus Dispensette SThe seripettor is designed for a fixed filling tube and a fixed workstation with recurring dispensing operations, whilst a Dispensette S is designed for a freely adjustable single volume. For media beyond the seripettor’s suitability, such as organic solvents, a Dispensette S Organic from our range is the more suitable alternative.Technical detailsVolume range1-10 mlGraduation0.2 mlAccuracy1.2 % / 120 µlCoefficient of variation0.2 % / 20 µlConnection threadGL45AutoclavabilityValve block, filling tube, discharge tube, valves: yes, 121 °C, 2 bar, DIN EN 285; actuation and dosing unit: noMaterialsPP, PE, EPDM. Actuation unit: PC; return spring: spring steel; dosing unit: PE/PP; valve block: PP; valves: PP/EPDM; discharge tube: PP; filling tubes: PP; cannula cap: PP.Application and maintenanceThe valve block with discharge tube is pre-assembled on the thread and is screwed onto the stock bottle using one of the three PP bottle adaptors (GL 32, GL 38, S 40). Before the first dispensing operation and after each change of fluid, the dispenser must be vented, as with any piston dispenser, by repeatedly actuating the dispensing unit until no air bubbles are visible in the filling tube. The filling tube is a fixed length of 250 mm and is not telescopic; the device is therefore particularly suitable for use with a fixed bottle size at the workstation. Two dispensing units are included, so there is no need to reorder immediately in the event of a fault or when switching between two media. For sterile batch processing, the valve block, filling tube, discharge tube and valves can be autoclaved after removing the actuator and dosing unit; thereafter, simply vent the system again before the next batch.Scope of deliveryseripettor actuator unitValve block with discharge tube (pre-assembled) for GL45 threaded bottlesFilling tube, 250 mm, fixed2 dosing units3 PP bottle adaptors (GL 32, GL 38, S 40)Mounting keyOperating instructionsFrequently asked questionsIs the valve block autoclavable?Yes, the valve block, filling tube, discharge tube and valves can be autoclaved at 121 °C, 2 bar, for at least 15 minutes according to DIN EN 285, after the actuator and dosing unit have been removed.What is the seripettor 1-10 ml not suitable for?Hydrofluoric acid; this is expressly excluded according to the manufacturer’s specifications.Which bottle thread fits the seripettor?GL45 directly; GL 32, GL 38 and S 40 are also compatible via a PP adapter.What distinguishes the standard seripettor from the seripettor pro?The standard model is designed for aqueous and mildly corrosive media, whilst the Pro model is additionally designed for concentrated hydrochloric acid, acetone and UV-sensitive media.Individual requirements and procurement serviceYou can enquire about additional dosing units, bottle adaptors or other accessories for the seripettor range on our service page. Please contact us via our service page.
Brand seripettor bottle-top dispenser, 2.5-25 ml, 4720150
The seripettor 2.5-25 ml is a bottle-top dispenser for repeated dosing directly from the supply bottle, without the need for a pipette. The valve block with discharge tube is pre-assembled onto the GL45 thread; dosing is controlled by the stroke of the actuator.Autoclavable except for two componentsThe valve block, filling tube, discharge tube and valves are autoclavable at 121 °C, 2 bar, for at least 15 minutes according to DIN EN 285, following removal of the actuator and dosing units. The actuator unit and dosing unit themselves are not autoclavable. For sterile batch processing, this means that the part of the dispenser in contact with the medium can be steam-sterilised without having to replace the entire device.Suitable for aqueous and mildly corrosive solutionsSuitable for aqueous solutions such as buffer solutions, detergents, anti-foaming agents, culture media, vitamin solutions and hydrogen peroxide; for agar culture media up to 60 °C; for weakly concentrated or diluted non-oxidising acids and alkalis such as sodium hydroxide solution, potassium hydroxide solution or ammonia, as well as for polar solvents such as ethanol, methanol and acetylacetone. Hydrofluoric acid is not suitable.Error limits for the 2.5-25 ml rangeFor the 2.5-25 ml range, Brand specifies an accuracy of 1.2 % / 300 µl and a coefficient of variation of 0.2 % / 50 µl, with a graduation of 0.5 ml.Typical applicationsFilling larger culture vessels with culture medium in a single strokeDispensing larger portions of buffer solution in routine preparationBatch processing with an autoclavable valve block for higher volume requirementsWorkstations where it would otherwise be necessary to top up several times using a smaller modelSelection guide: Volumes and mediaThe 2.5-25 ml stage is the largest in the seripettor range and is designed for dispensing operations where more than 10 ml per stroke is required, such as when filling larger culture vessels. For smaller volumes, 0.2-2 ml and 1-10 ml stages are available. Sodium hydroxide, potassium hydroxide and ammonia are also suitable for this stage; hydrofluoric acid is excluded. Those requiring concentrated hydrochloric acid as well will find the same volume stage available as the seripettor pro.seripettor versus Dispensette SThe seripettor dispenses repeatedly from a permanently mounted bottle, whereas a Dispensette S allows for a freely adjustable volume per stroke. For media that exceed the seripettor’s suitability, such as organic solvents, a Dispensette S Organic from our range is recommended.Technical detailsVolume range2.5-25 mlGraduation0.5 mlAccuracy1.2 % / 300 µlCoefficient of variation0.2 % / 50 µlConnection threadGL45AutoclavabilityValve block, filling tube, discharge tube, valves: yes, 121 °C, 2 bar, DIN EN 285; actuating and dosing unit: noMaterialsPP, PE, EPDM. Actuation unit: PC; return spring: spring steel; dosing unit: PE/PP; valve block: PP; valves: PP/EPDM; discharge tube: PP; filling tubes: PP; cannula cap: PP.Application and maintenanceThe valve block with discharge tube is pre-assembled on the thread and is screwed onto the supply bottle using one of the three PP bottle adaptors (GL 32, GL 38, S 40). Before the first dispensing operation and after each change of fluid, the dispenser must be vented, as with any piston dispenser, by repeatedly actuating the dosing unit until no air bubbles are visible in the filling tube. The filling tube has a fixed length of 250 mm and is not telescopic; the device is therefore particularly suitable for use with a fixed bottle size at the workstation. Two dosing units are included, so there is no need to reorder immediately in the event of a fault or when switching between two media. For sterile batch processing, the valve block, filling tube, discharge tube and valves can be autoclaved after removing the actuator and dosing unit; thereafter, simply vent the system again before the next batch.Scope of deliveryseripettor actuator unitValve block with discharge tube (pre-assembled) for GL45 threaded bottlesFilling tube, 250 mm, fixed2 dosing units3 PP bottle adaptors (GL 32, GL 38, S 40)Mounting keyOperating instructionsFrequently asked questionsIs the valve block autoclavable?Yes, the valve block, filling tube, discharge tube and valves can be autoclaved at 121 °C, 2 bar, for at least 15 minutes according to DIN EN 285, after the actuator and dosing units have been removed.What is the seripettor 2.5-25 ml not suitable for?Hydrofluoric acid; this is expressly excluded according to the manufacturer’s specifications.Which bottle thread fits the seripettor?GL45 directly; GL 32, GL 38 and S 40 are also compatible via the PP adaptors supplied.What distinguishes the standard seripettor from the seripettor pro?The standard is designed for aqueous and mildly corrosive media, whilst the pro is additionally designed for concentrated hydrochloric acid, acetone and UV-sensitive media.Individual requirements and procurement serviceYou can enquire about additional dosing units, bottle adaptors or other accessories for the seripettor range via our procurement service. Please contact us via our service page.
Brand Dispensette S Analog, with recirculation valve, bottle-top dispenser (0.1 to 100 ml), 0.5 ml to 5 ml
The classic model with added efficiency: BRAND Dispensette S Analog (with recirculation valve) The BRAND Dispensette S Analog is the proven standard for precise dispensing directly from the stock bottle. In this version, the device is fitted with a recirculation valve as standard. This small but crucial feature simplifies your workflow during venting: instead of wasting valuable reagent by discarding it into a beaker, you simply return it to the bottle whilst venting. This can save reagent. Simple, Safe, Analogue The ‘S’ generation stands for ‘Safe, Simple, Efficient’. Analogue adjustment: The desired volume is set using a mechanical slide control with an internal rack. This ensures a secure setting that cannot be accidentally altered, even during hectic operation. Smooth operation: Thanks to advanced piston and cylinder materials, the piston glides almost effortlessly. Suction and ejection require minimal force. This is pleasant during long dispensing series. Flexibility: The valve block can be rotated through 360°, so you can always align the dispensing tube perfectly with the bottle’s label. Recirculation valve: how it works A simple turn of the valve is all it takes: ‘Back-dosing’ position: The piston is moved to remove air bubbles from the cylinder. The liquid flows back into the bottle. This means less splashing and less wastage. ‘Dosing’ position: Once the cylinder is free of air bubbles, switch the valve over and dispense precisely into your container. Universal use (colour code: red) The Dispensette S covers a very wide range of media. It is suitable for corrosive reagents such as concentrated acids (e.g. H₃PO₄, H₂SO₄), alkalis (e.g. NaOH, KOH), salt solutions and many organic solvents. (Exception: For hydrofluoric acid, please use the Trace Analysis version). Technical data Model: Dispensette S Analog Special feature: Includes a recirculation valve Adjustment type: Analogue (slider) Volume range: 0.5 ml to 5 ml Materials in contact with the medium: borosilicate glass, Al₂O₃ ceramic, platinum-iridium, ETFE, FEP, PFA, PP (screw cap) Operating limits: Vapour pressure: max. 600 mbar Viscosity: max. 500 mm²/s Temperature: max. +40 °C Density: max. 2.2 g/cm³ Autoclavable: Yes, completely at 121 °C (without disassembly) DE-M marking under German measurement and verification law: Yes Scope of delivery 1 x BRAND Dispensette S Analog (volume 0.5 ml to 5 ml) 1 x recirculation valve (already fitted) 1 x dispensing cannula 1 x telescopic suction tube (adjustable in length, suitable for the nominal volume) 1 x assembly key 1 x adapter set for various bottle threads (polypropylene) (For 1, 2, 5, 10 ml: GL 24 to 25, GL 28/S 28, GL 32 to 33, GL 38) (For 25, 50, 100 ml: GL 32 to 33, GL 38, S 40) 1 x quality certificate 1 x operating instructions Individual requirements & accessories Do you have the right storage bottle? Bottles: Also available are laboratory bottles with a GL 45 thread (standard) in clear glass or amber glass (light-protective). Extensions: For particularly deep containers, we offer extended suction tubes and flexible discharge hoses (for batch dispensing). Please contact our procurement service for spare parts or specialist accessories.
Brand Dispensette S Bottle-Top Dispenser, Digital, 0.2-2 ml, without Recirculation Valve, DE-M, 4600320
Anyone in the laboratory who repeatedly needs to prepare calibration standards wants to be able to read the volume without estimating the scale by eye. With 0.2 to 2 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.Media compatibilityThe red standard version is suitable for aggressive reagents, concentrated alkalis and acids such as phosphoric acid or sulphuric acid, salt solutions and many organic solvents. Not suitable for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids. The yellow Dispensette S Organic is intended for concentrated hydrochloric and nitric acid, THF and trifluoroacetic acid; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: steam sterilisation at 121 °C and 2 bar gauge pressure for at least 15 minutes according to DIN EN 285, followed by about 2 hours of cooling time in the closed autoclave. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Distinction within the Dispensette S standard seriesCompared with the Fix version of the same series, the Digital variant allows the volume to be chosen freely within the stated range, read from the counter rather than from a scale as with Analog. For workstations with constantly changing target volumes this is the more practical route, whereas for a single fixed value the simpler Fix version is sufficient.Accuracy and graduationAccuracy is 0.5 %/10 µl, the coefficient of variation figure 0.1 %/2 µl, the graduation 0.01 ml. These values apply to all volumes set within the range 0.2 to 2 ml and were determined according to the general test procedure for piston-stroke devices.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Without recirculation valveThis version works without a recirculation valve. The design is therefore simpler, with one less moving part in the dispensing path. For applications where every dispensed volume goes directly into the target vessel and no return is needed, this slimmer design is sufficient.Mounting and handlingAfter screwing on the matching bottle adapter and shortening the telescopic filling tube to the bottle height, the next step is venting: draw in and dispense into a waste container several times until no more air bubbles are visible. The mounting key supplied is used for later valve changes.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 0.2 to 2 ml intended?Typical uses include the spiking of samples with defined very small amounts, this volume range is intended for such applications.Typical applicationsPreparing calibration standardssmall reagent additions in titrationSpiking of samples with defined very small amountsTechnical detailsLineBrand Dispensette S, DigitalVolume0.2 to 2 mlGraduation0.01 mlAccuracy0.5 %/10 µlCoefficient of variation0.1 %/2 µlRecirculation valvenoMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavabilitysteam sterilisation at 121 °C and 2 bar gauge pressure for at least 15 minutes according to DIN EN 285, followed by about 2 hours of cooling time in the closed autoclaveMarkingDE-MManufacturer article no.4600320Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support through our own procurement service.
Brand Dispensette S Bottle-Top Dispenser, Digital, 0.2-2 ml, with Recirculation Valve, DE-M, 4600321
Anyone in the laboratory who repeatedly needs to prepare calibration standards wants to be able to read the volume without estimating the scale by eye. With 0.2 to 2 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.AutoclavabilityThe complete device is autoclavable: 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time around 2 hours in the closed autoclave. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Distinction within the Dispensette S standard seriesThe three versions of the Dispensette S standard series differ in the way the volume is set, not in accuracy. Anyone who changes more often between volumes within the stated range gets on fastest with the Digital display. Anyone who is comfortable with a mechanical scale saves on purchase cost with the Analog version. And anyone who permanently needs only one volume gets by most easily with the Fix version.Accuracy and graduationAccuracy is 0.5 %/10 µl, the coefficient of variation figure 0.1 %/2 µl, the graduation 0.01 ml. These values apply to all volumes set within the range 0.2 to 2 ml and were determined according to the general test procedure for piston-stroke devices.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Recirculation functionThis version has a recirculation valve. Excess liquid can thus be returned to the stock bottle without opening the discharge tube or removing the bottle. This is practical with expensive or hazardous reagents, for example when a calibration check needs several back-weighings or when too much volume was dispensed by mistake.Mounting and handlingThe Dispensette S Digital is mounted directly on the stock bottle using the bottle adapter supplied, and the telescopic filling tube can be shortened to the bottle height. The mounting key is part of the scope of delivery and is needed when changing the valve or discharge tube. After fitting, the device is drawn up and dispensed into a waste container several times until there are no more air bubbles in the system, after which it is ready for use.Media compatibilityThe range of media includes aggressive reagents, highly concentrated acids such as phosphoric or sulphuric acid, salt solutions and many organic solvents. By contrast, hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids must not be dispensed. The yellow Organic variant is intended for concentrated hydrochloric and nitric acid, THF and trifluoroacetic acid; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 0.2 to 2 ml intended?Typical uses include the spiking of samples with defined very small amounts, this volume range is intended for such applications.Typical applicationsPreparing calibration standardssmall reagent additions in titrationSpiking of samples with defined very small amountsTechnical detailsLineBrand Dispensette S, DigitalVolume0.2 to 2 mlGraduation0.01 mlAccuracy0.5 %/10 µlCoefficient of variation0.1 %/2 µlRecirculation valveyesMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavability121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time around 2 hours in the closed autoclaveMarkingDE-MManufacturer article no.4600321Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tube including recirculation tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support via our procurement service.
Brand Dispensette S Organic bottle-top dispenser, Digital, 1-10 ml, with recirculation valve, DE-M, 4630341
Concentrated nitric acid and organic solvents are media where a dispensing mishap should not simply go down the drain. The Brand Dispensette S Organic Digital with recirculation valve (1 to 10 ml) can be vented before the first dispensing without losing any reagent. At 1-10 ml the graduation is 0.05 ml, the accuracy is 0.5 %/50 µl and the coefficient of variation is 0.1 %/10 µl.Typical applicationsThe yellow colour code identifies the Organic series in the Brand range. Typical applications for 1-10 ml:Venting before dispensing concentrated nitric acid in sample digestion, without reagent lossAdding organic solvents in extraction, with excess volume returnedDispensing varying amounts of THF in synthesis, where any excess goes back into the bottle instead of into wasteDigital version and selection guideThe volume is set using the volume adjustment wheel with mechanical counter and can be quickly readjusted between individual dispensing steps. Digital devices can be adjusted without tools via Easy Calibration. Matching bottle adapters for GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 are included, and the filling tube can be adjusted to 125-240 mm.With nitric acid or organic solvents in larger quantities, the recirculation valve pays off in daily venting, because no reagent is discarded. For non-critical, inexpensive media in the same range, the version without a recirculation valve is sufficient.Materials and autoclavabilityWetted parts are made of borosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter). The device is autoclavable under the following conditions: 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclave. Tantalum as the valve spring material, together with the fluoroplastics ETFE, FEP, PFA and PTFE, makes the Organic series suitable for organic solvents and some concentrated acids, but not for alkaline solutions and salt solutions.The Dispensette S Organic is not suitable for alkaline solutions, salt solutions, carbon disulphide, explosive liquids and media that attack borosilicate glass, such as hydrofluoric acid. For alkaline solutions and salt solutions, the Dispensette S in red (standard) is the suitable series, and for trace analysis with a selectable valve spring of platinum-iridium or tantalum, the Dispensette S Trace Analysis.Assembly and changing to a different reservoir bottle are done with the supplied mounting tool and the telescopic filling tube, which can be adjusted to the respective bottle height. The bottle adapter included in the scope of delivery fits the respective GL45-compatible thread and makes the dispenser usable regardless of the specific reservoir bottle.Accuracy at a glanceFor 1-10 ml: graduation 0.05 ml, accuracy 0.5 %/50 µl, coefficient of variation 0.1 %/10 µl. The DE-M marking in the product name refers to conformity assessment under German weights and measures law; it does not replace a calibration certificate.Other volumes in the digital versionIn addition to 1-10 ml, further volume ranges are available within the Dispensette S Organic Digital:VolumeAccuracyMPN (without recirculation valve)0.5-5 ml0.5 %/25 µl46303302.5-25 ml0.5 %/125 µl46303505-50 ml0.5 %/250 µl4630360Frequently asked questionsWhat is the recirculation valve needed for?It allows the dispensing system to be vented before first use without losing any reagent: air and excess volume go back into the reservoir bottle via the recirculation tube instead of into waste. This is particularly relevant with expensive or environmentally relevant solvents.How is the digital version adjusted in the 1-10 ml range?Via Easy Calibration, without tools. A changed factory adjustment is indicated by a red marking on the device.Technical detailsVersionDigitalRecirculation valveyes, incl. recirculation tubeVolume range1-10 mlGraduation0.05 mlAccuracy (A)0.5 %/50 µlCoefficient of variation (CV)0.1 %/10 µlColour codeyellow (Organic)Valve springTantalumWetted materialsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter)Autoclavableyes, 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclaveThreadGL45Adapter/filling tubeAdapters: GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40; filling tube 125-240 mm; incl. recirculation tubeScope of delivery1 Dispensette S Organic bottle-top dispenser for GL45 threaded bottlesDischarge tube with recirculation valve, including recirculation tubeTelescopic filling tubeMounting toolBottle adapter matching the volume rangeQuality certificateOperating instructionsDistinction within the Dispensette S familyFor the medium dispensed here, the yellow Organic series is suitable. For alkaline solutions or most other acids, the red standard Dispensette S would be called for instead. For trace analysis with a selectable valve spring of platinum-iridium or tantalum, the Dispensette S Trace Analysis is available separately.Individual requirements & procurement serviceAdditional requirements for bottle adapters, spare valves or further volume ranges of the Dispensette S Organic can be clarified via our procurement service.
Brand Dispensette S Bottle-Top Dispenser, Digital, 0.1-1 ml, without Recirculation Valve, DE-M, 4600310
Anyone in the laboratory who repeatedly needs trace additions of colour reagents in photometry wants to be able to read the volume without estimating the scale by eye. With 0.1 to 1 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Without recirculation valveThis version works without a recirculation valve. The design is therefore simpler, with one less moving part in the dispensing path. For applications where every dispensed volume goes directly into the target vessel and no return is needed, this slimmer design is sufficient.Mounting and handlingThe Dispensette S Digital is mounted directly on the stock bottle using the bottle adapter supplied, and the telescopic filling tube can be shortened to the bottle height. The mounting key is part of the scope of delivery and is needed when changing the valve or discharge tube. After fitting, the device is drawn up and dispensed into a waste container several times until there are no more air bubbles in the system, after which it is ready for use.Media compatibilityThe red standard version tolerates a wide range of reagents: concentrated acids such as phosphoric acid and sulphuric acid, concentrated alkalis, salt solutions and numerous organic solvents. Excluded are hydrofluoric acid as well as hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids. Anyone who regularly dispenses concentrated hydrochloric or nitric acid should choose the yellow Dispensette S Organic; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: sterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours of cooling time in the closed device. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Distinction within the Dispensette S standard seriesThe three versions of the Dispensette S standard series differ in the way the volume is set, not in accuracy. Anyone who changes more often between volumes within the stated range gets on fastest with the Digital display. Anyone who is comfortable with a mechanical scale saves on purchase cost with the Analog version. And anyone who permanently needs only one volume gets by most easily with the Fix version.Accuracy and graduationAccuracy is 0.5 %/5 µl, the coefficient of variation figure 0.1 %/1 µl, the graduation 0.005 ml. These values apply to all volumes set within the range 0.1 to 1 ml and were determined according to the general test procedure for piston-stroke devices.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 0.1 to 1 ml intended?Typical uses include the addition of very small amounts of reagent in serial analysis, this volume range is intended for such applications.Typical applicationsTrace additions of colour reagents in photometryIndicator drops in titrationAddition of very small amounts of reagent in serial analysisTechnical detailsLineBrand Dispensette S, DigitalVolume0.1 to 1 mlGraduation0.005 mlAccuracy0.5 %/5 µlCoefficient of variation0.1 %/1 µlRecirculation valvenoMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavabilitySterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours of cooling time in the closed deviceMarkingDE-MManufacturer article no.4600310Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support through our own procurement service.
Brand Dispensette S Bottle-Top Dispenser, Digital, 5-50 ml, with Recirculation Valve, DE-M, 4600361
Anyone in a microbiology laboratory who has to portion media repeatedly wants to be able to read the volume without estimating the scale by eye. With 5 to 50 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.Mounting and handlingAfter screwing on the matching bottle adapter and shortening the telescopic filling tube to the bottle height, the next step is venting: draw in and dispense into a waste container several times until no more air bubbles are visible. The mounting key supplied is used for later valve changes.Media compatibilityThe range of media includes aggressive reagents, highly concentrated acids such as phosphoric or sulphuric acid, salt solutions and many organic solvents. By contrast, hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids must not be dispensed. The yellow Organic variant is intended for concentrated hydrochloric and nitric acid, THF and trifluoroacetic acid; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time around 2 hours in the closed autoclave. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Distinction within the Dispensette S standard seriesCompared with the Fix version of the same series, the Digital variant allows the volume to be chosen freely within the stated range, read from the counter rather than from a scale as with Analog. For workstations with constantly changing target volumes this is the more practical route, whereas for a single fixed value the simpler Fix version is sufficient.Accuracy and graduationAccuracy is 0.5 %/250 µl, the coefficient of variation 0.1 %/50 µl, the graduation 0.2 ml. These values apply to all volumes set within the range 5 to 50 ml and were determined according to the general test procedure for piston-stroke devices.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Recirculation functionThis version has a recirculation valve. Excess liquid can thus be returned to the stock bottle without opening the discharge tube or removing the bottle. This is practical with expensive or hazardous reagents, for example when a calibration check needs several back-weighings or when too much volume was dispensed by mistake.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 5 to 50 ml intended?Typical uses include the preparation of culture solutions and buffers in larger batches, this volume range is intended for such applications.Typical applicationsMedia portioning in the microbiology laboratoryFilling larger quantities of reagentPreparing culture solutions and buffers in larger batchesTechnical detailsLineBrand Dispensette S, DigitalVolume5 to 50 mlGraduation0.2 mlAccuracy0.5 %/250 µlCoefficient of variation0.1 %/50 µlRecirculation valveyesMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavability121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time around 2 hours in the closed autoclaveMarkingDE-MManufacturer article no.4600361Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tube including recirculation tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support via our procurement service.
Brand seripettor pro bottle-top dispenser, 1-10 ml, 4720440
The seripettor pro 1-10 ml is the chemical-resistant version of the bottle-top dispenser, featuring materials that are suitable for use with media beyond the aqueous and mildly corrosive media handled by the standard seripettor. The valves and discharge tube are made from materials including platinum-iridium, borosilicate glass and ETFE.Extended media compatibility thanks to different materialsIn addition to the range of aqueous and mildly corrosive media handled by the standard seripettor, the seripettor pro is suitable for acids such as concentrated hydrochloric acid, for polar solvents such as acetone, and for UV-sensitive media. It is not suitable for concentrated or oxidising acids (with the exception of hydrochloric acid), hydrofluoric acid, hydrogen peroxide (which decomposes catalytically on platinum-iridium), non-polar and halogenated hydrocarbons, suspensions, explosive liquids and carbon disulphide.UV-protected actuator unitThe PPO/PEI actuator unit with UV protection and the Hastelloy return spring distinguish the seripettor pro from the standard version with spring steel. When dispensing moderate volumes of light-sensitive reagents, this design prevents the actuator unit itself from becoming a weak point in the workflow.Error limits for the 1-10 ml rangeFor the 1-10 ml range, Brand specifies an accuracy of 1.2 % / 120 µl and a coefficient of variation of 0.2 % / 20 µl, with a graduation of 0.2 ml. These values correspond to those of the standard seripettor in the same volume range; the change in materials does not affect dosing accuracy.Typical applicationsDispensing acids and organic solvents in routine quantitiesPreparing UV-sensitive reagents directly from the stock bottleWorkstations where the standard seripettor is not suitable due to media compatibility issuesSelection guide: Volume and mediaWith a range of 1 to 10 ml, the seripettor pro covers the medium volume range for more aggressive media, falling between the fine 0.2-2 ml range and the larger 2.5-25 ml range. Concentrated hydrochloric acid, acetone and UV-sensitive media are equally suitable for all three pro ranges; hydrofluoric acid remains excluded. Those who only dispense aqueous and mildly corrosive media, such as caustic soda or ammonia, will find the standard seripettor sufficient within the same volume range.seripettor pro versus Dispensette SDue to its design, the seripettor pro remains a bottle-top dispenser with a telescopic filling tube; it is not a pipette and does not offer an adjustable single volume as with a Dispensette S. For media outside the pro’s suitability range, such as hydrofluoric acid, a Dispensette S with appropriate materials from our range is the alternative.Technical detailsVolume range1-10 mlGraduation0.2 mlAccuracy1.2 % / 120 µlCoefficient of variation0.2 % / 20 µlConnection threadGL45MaterialsPP, PE, borosilicate glass, Al2O3 ceramic, ETFE, PFA, FEP, PTFE, platinum-iridium. Actuator unit: PPO/PEI with UV protection; return spring: Hastelloy; dosing unit: PE/PP; valve block: PP; valves: ETFE/borosilicate glass/Al2O3/platinum-iridium; discharge tube: PTFE/ETFE/FEP/PFA/borosilicate glass/Al2O3/platinum-iridium; filling tubes (telescopic): FEP/PTFE; cannula cap: PP.Use and maintenanceUnlike the standard seripettor, the filling tube on the seripettor pro is telescopic and can be adjusted from 125 to 240 mm, accommodating different bottle heights at the same workstation. The valve block with discharge tube is pre-assembled on the thread and is screwed onto the stock bottle using one of the three PP bottle adaptors (GL 32, GL 38, S 40). Before first use and whenever the medium is changed, the system must be vented by actuating the dosing unit several times until no air bubbles are visible in the filling tube; this is particularly important when switching between aqueous and more aggressive media. Two dosing units are included, so there is no need to reorder immediately when switching between two different media.Scope of deliveryseripettor pro actuator unitValve block with discharge tube (pre-assembled) for GL45 threaded bottlesTelescopic filling tube, 125 to 240 mm2 dosing units3 PP bottle adaptors (GL 32, GL 38, S 40)Mounting keyInstructions for useNo information on the autoclavability of the seripettor pro is provided; the manufacturer’s specifications regarding autoclavability apply expressly to the standard seripettor only.Frequently asked questionsIs the seripettor pro autoclavable?No details are provided; the manufacturer’s specifications regarding autoclavability apply only to the standard seripettor.What is the seripettor pro 1-10 ml not suitable for?Hydrofluoric acid, hydrogen peroxide, non-polar and halogenated hydrocarbons, as well as suspensions and explosive liquids.Which bottle thread fits the seripettor pro?GL45 directly; via PP adaptors also GL 32, GL 38 and S 40.Why is the actuator unit UV-protected?It is made of PPO/PEI so that even light-sensitive media can be dispensed, for which a standard version would not be suitable.Individual requirements and procurement serviceThrough our procurement service, you can request additional dosing units, bottle adaptors or other accessories for the seripettor pro range. Contact us via our service page.
Brand Dispensette S Bottle-Top Dispenser, Digital, 1-10 ml, without Recirculation Valve, DE-M, 4600340
Anyone in the laboratory who repeatedly needs a routine reagent addition wants to be able to read the volume without estimating the scale by eye. With 1 to 10 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.Mounting and handlingThe Dispensette S Digital is mounted directly on the stock bottle using the bottle adapter supplied, and the telescopic filling tube can be shortened to the bottle height. The mounting key is part of the scope of delivery and is needed when changing the valve or discharge tube. After fitting, the device is drawn up and dispensed into a waste container several times until there are no more air bubbles in the system, after which it is ready for use.Media compatibilitySuitable for aggressive reagents, concentrated alkalis and acids such as phosphoric acid or sulphuric acid, salt solutions and many organic solvents. Not suitable for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids. The yellow Dispensette S Organic is intended for concentrated hydrochloric and nitric acid, THF and trifluoroacetic acid; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: steam sterilisation at 121 °C and 2 bar gauge pressure for at least 15 minutes according to DIN EN 285, followed by about 2 hours of cooling time in the closed autoclave. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Distinction within the Dispensette S standard seriesThe three versions of the Dispensette S standard series differ in the way the volume is set, not in accuracy. Anyone who changes more often between volumes within the stated range gets on fastest with the Digital display. Anyone who is comfortable with a mechanical scale saves on purchase cost with the Analog version. And anyone who permanently needs only one volume gets by most easily with the Fix version.Accuracy and graduationAccuracy is 0.5 %/50 µl, the coefficient of variation figure 0.1 %/10 µl, the graduation 0.05 ml. These values apply to all volumes set within the range 1 to 10 ml and were determined according to the general test procedure for piston-stroke devices.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Without recirculation valveThis version works without a recirculation valve. The design is therefore simpler, with one less moving part in the dispensing path. For applications where every dispensed volume goes directly into the target vessel and no return is needed, this slimmer design is sufficient.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 1 to 10 ml intended?Typical uses include recurring additions in analysis series, this volume range is intended for such applications.Typical applicationsRoutine reagent addition in the laboratoryBuffer preparation in common volumesrecurring additions in analysis seriesTechnical detailsLineBrand Dispensette S, DigitalVolume1 to 10 mlGraduation0.05 mlAccuracy0.5 %/50 µlCoefficient of variation0.1 %/10 µlRecirculation valvenoMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavabilitysteam sterilisation at 121 °C and 2 bar gauge pressure for at least 15 minutes according to DIN EN 285, followed by about 2 hours of cooling time in the closed autoclaveMarkingDE-MManufacturer article no.4600340Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support via our procurement service.
Brand Dispensette S Organic bottle-top dispenser, Digital, 1-10 ml, without recirculation valve, DE-M, 4630340
When carrying out acid digestion of smaller sample volumes, 1 ml of concentrated hydrochloric acid is often added initially; for larger batches, a greater volume may be added in the same step. The Brand Dispensette S Organic Digital covers this range, from 1 to 10 ml, in a single device. For volumes of 1-10 ml, the graduation is 0.05 ml, the accuracy is 0.5 %/50 µl, and the coefficient of variation is 0.1 %/10 µl.Typical applicationsThe colour code ‘Yellow’ identifies the Organic series within the Brand range. Typical applications for 1-10 ml:Addition of approximately 1 ml of concentrated hydrochloric acid during the acid digestion of small sample quantitiesDosing of organic solvents during liquid-liquid extractionAddition of varying quantities of THF during reaction optimisation in synthesisDigital version and selection guideThe volume is set using the volume adjustment wheel with a mechanical counter and can be quickly readjusted between individual dosing steps. Digital devices can be adjusted without tools using Easy Calibration. Suitable bottle adaptors for GL 24-25, GL 28/S 28, GL 32-33, GL 38 and S 40 are included; the suction tube can be adjusted to 125-240 mm.If the volume is changed between several values in the range of 1 to 10 ml within a digestion protocol, the counter on the digital version clearly displays the current value. If, on the other hand, the same volume of hydrochloric acid is always used, the simpler analogue version is sufficient.Materials and autoclavabilityParts in contact with the medium are made of borosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum and PP (screw cap/bottle adapter). The device is autoclavable under the following conditions: 121 °C, 2 bar, for at least 15 minutes according to DIN EN 285, with a cooling time of approx. 2 hours in a closed autoclave. The use of tantalum as the valve spring material, together with the fluoroplastics ETFE, FEP, PFA and PTFE, makes the Organic series suitable for use with organic solvents and certain concentrated acids; however, it is not suitable for alkalis or salt solutions.The Dispensette S Organic is not suitable for alkalis, salt solutions, carbon disulphide, explosive liquids or media that attack borosilicate glass, such as hydrofluoric acid. For alkalis and salt solutions, the Dispensette S in red (standard) is the suitable series; for trace analysis with a selectable valve spring made of platinum-iridium or tantalum, the Dispensette S Trace Analysis is recommended.Installation and switching to a different supply bottle are carried out using the supplied mounting key and the telescopic suction tube, which can be adjusted to the height of the respective bottle. The bottle adapter included in the scope of delivery fits the relevant GL45-compatible thread, allowing the dispenser to be used regardless of the specific storage bottle.Accuracy at a glanceFor 1-10 ml: graduation 0.05 ml, accuracy 0.5 %/50 µl, coefficient of variation 0.1 %/10 µl. The DE-M marking in the product name refers to conformity assessment under German weights and measures law; it does not replace a calibration certificate.Other volumes in the digital versionIf you require a range beyond 1-10 ml, you will find it within the digital version of the Dispensette S Organic:VolumeAccuracyMPN (without recirculation valve)0.5-5 ml0.5 %/25 µl46303302.5-25 ml0.5 %/125 µl46303505-50 ml0.5 %/250 µl4630360Frequently asked questionsCan this model be retrofitted with a recirculation valve?According to the manufacturer, the version with a recirculation valve has its own order number and comes with its own discharge tube including a recirculation tube; it is not a retrofit option for the version without a recirculation valve.How is the digital version adjusted in the 1-10 ml range?With Easy Calibration, this can be done without any additional tools; a changed factory adjustment is indicated by a red marking.Technical detailsModelDigitalRecirculation valvenoVolume range1-10 mlGraduation0.05 mlAccuracy (A)0.5 %/50 µlCoefficient of variation (CV)0.1 %/10 µlColour codeyellow (Organic)Valve springTantalumMaterials in contact with the mediumBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter)AutoclavableYes, 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in a closed autoclaveThreadGL45Adapter/suction tubeAdapters: GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40; suction tube 125-240 mmScope of delivery1 Dispensette S Organic bottle-top dispenser for GL45-threaded bottlesDischarge tube without recirculation valveTelescopic suction tubeMounting keyBottle adaptor suitable for the relevant volume rangeQuality certificateOperating instructionsDistinction within the Dispensette S familyThe choice between red and yellow depends solely on the medium: Organic (yellow) is suitable for the organic solvents described here and for concentrated hydrochloric acid/nitric acid, whilst the standard version (red) is suitable for alkalis and most other acids. The Dispensette S Trace Analysis is available separately for trace analysis, with a choice of valve spring made from platinum-iridium or tantalum.Individual requirements and procurement serviceSuitable bottle adaptors, spare parts and further volume ranges for the Dispensette S Organic can be requested via our procurement service.
Brand Dispensette S Bottle-Top Dispenser, Fix, 10 ml, without recirculation valve, DE-M, 4600240
Where a fixed volume is filled in larger series, an adjustable volume is not needed and tends to get in the way. The Dispensette S Fix with 10 ml dispenses exactly this one volume, without a scale and without the Easy-Calibration function. Anyone who wants to rule out accidental adjustment, for example when staff change at a workstation, benefits from this reduced design. Like the other Dispensette S versions, the Fix is mounted directly on the reagent bottle and belongs to the same standard series with the red colour code.Assembly and handlingThe Dispensette S Fix is screwed onto the reservoir bottle using the supplied bottle adapter, and the telescopic filling tube can be shortened to the right length. Before first use, the system is drawn up several times and emptied into a waste vessel until no more air bubbles are visible. The mounting tool in the scope of delivery is needed for valve replacement.Media suitabilitySuitable for aggressive reagents, concentrated alkaline solutions and acids such as phosphoric acid or sulphuric acid, salt solutions and many organic solvents. Not suitable for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids. The yellow Dispensette S Organic is intended for concentrated hydrochloric and nitric acid, THF and trifluoroacetic acid; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: steam sterilisation at 121 °C and 2 bar gauge pressure for at least 15 minutes according to DIN EN 285, followed by about 2 hours of cooling time in the closed autoclave. For sterile workplaces, for example when preparing microbiological culture media, the Dispensette S Fix can therefore be re-sterilised before every batch.Fix or DigitalFor changing volumes within the same range, the Digital version with counter or the Analog version with scale is the better choice. If, on the other hand, it is certain that only this one volume will ever be needed, the Fix saves operating steps and avoids accidental adjustment.Accuracy without a scaleAccuracy and coefficient of variation are 0.5 %/50 µl and 0.1 %/10 µl respectively. The Fix version has no scale graduation; the fixed volume is adjusted at the factory and is not set on the device. Anyone who still wants to check the accuracy does so by back-weighing with an analytical balance; the procedure is the same whether the volume is fixed or adjustable.Fixed volume instead of an adjustment wheelDispensing with no counter and no adjustment mechanism reduces the number of moving parts in the dispensing path. This makes handling simpler than with the Digital version and suits adding media to a constant target value, where changing the target volume never happens anyway. Especially when staff change at a workstation, the fixed volume reduces the risk of an incorrectly set scale, because the Fix version simply has no scale.Without recirculation valveWithout a recirculation valve, the design is reduced to the essentials. For a fixed-volume device that always dispenses the same quantity anyway, this simpler design is entirely sufficient in many routines.Frequently asked questionsCan the volume of the Fix be changed afterwards?No, the volume is adjusted at the factory and cannot be set on the device, unlike the Digital or Analog version of the same series.Which bottle sizes fit the Dispensette S Fix?According to the accessories table, the adapters GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.Why 10 ml as a fixed volume and not an adjustable range?Because the work step this device is intended for always needs the same volume, the fixed volume saves one operating step compared with an adjustable version.Typical applicationsFilling a fixed volume in larger seriesAdding media to a constant target valueTechnical detailsSeriesBrand Dispensette S, FixVolume10 ml (fixed volume)Scale graduationnot present, fixed volume adjusted at the factoryAccuracy0.5 %/50 µlCoefficient of variation0.1 %/10 µlRecirculation valvenoMedia suitabilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on the screw cap and bottle adapterAutoclavabilitysteam sterilisation at 121 °C and 2 bar gauge pressure for at least 15 minutes according to DIN EN 285, followed by about 2 hours of cooling time in the closed autoclaveMarkingDE-MManufacturer part no.4600240Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tubeTelescopic filling tubeMounting toolBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements & procurement serviceFor further fixed volumes from the Dispensette S Fix series or suitable bottle adapters, we provide support via our own procurement service.
Brand Dispensette S Organic bottle-top dispenser, Analog, 5-50 ml, with recirculation valve, DE-M, 4630161
When decanting larger quantities of an expensive organic solvent, nothing should be lost when venting, even with a fixed Analog setting. The Brand Dispensette S Organic Analog with recirculation valve (5 to 50 ml) returns excess volume to the stock bottle. At 5-50 ml the graduation is 1 ml, the accuracy is 0.5 %/250 µl and the coefficient of variation is 0.1 %/50 µl.Typical applicationsThe yellow colour code identifies the Organic series in the Brand range. Typical applications for 5-50 ml:Venting before decanting larger quantities of organic solvent, without reagent lossrecurring dichloromethane dispensing, with excess volume returnedstandardised addition of concentrated hydrochloric acid, with refilling without lossAnalog version and selection guideThe volume is set using the volume adjustment screw with indicator arrow: loosen the screw by three quarters of a turn, slide the indicator arrow to the scale value, and tighten the screw again. Once set, the value stays until deliberately changed. Analog devices can be adjusted without tools via Easy Calibration. Matching bottle adapters for GL 32-33, GL 38, S 40 are included, and the filling tube can be adjusted to 170-330 mm.With repeated decanting of expensive solvents, the recirculation valve pays off when venting. For inexpensive media, the Analog version without recirculation valve is sufficient.Materials and autoclavabilityWetted parts are made of borosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter). The device is autoclavable under the following conditions: 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclave. Tantalum as the valve spring material, together with the fluoroplastics ETFE, FEP, PFA and PTFE, makes the Organic series suitable for organic solvents and some concentrated acids, but not for alkaline solutions and salt solutions.The Dispensette S Organic is not suitable for alkaline solutions, salt solutions, carbon disulphide, explosive liquids and media that attack borosilicate glass, such as hydrofluoric acid. For alkaline solutions and salt solutions, the Dispensette S in red (standard) is the suitable series, and for trace analysis with a selectable valve spring of platinum-iridium or tantalum, the Dispensette S Trace Analysis.Assembly and changing to a different stock bottle are done with the supplied mounting key and the telescopic filling tube, which can be adjusted to the respective bottle height. The bottle adapter included in the scope of delivery fits the respective GL45-compatible thread and makes the dispenser usable regardless of the specific stock bottle.Accuracy at a glanceFor 5-50 ml: graduation 1 ml, accuracy 0.5 %/250 µl, coefficient of variation 0.1 %/50 µl. The DE-M marking in the product name refers to conformity assessment under German weights and measures law; it does not replace a calibration certificate.Other volumes in the Analog versionIn addition to 5-50 ml, further volume ranges are available within the Dispensette S Organic Analog:VolumeAccuracyMPN (without recirculation valve)0.5-5 ml0.5 %/25 µl46301301-10 ml0.5 %/50 µl46301402.5-25 ml0.5 %/125 µl463015010-100 ml0.5 %/500 µl4630170Frequently asked questionsWhat is the recirculation valve needed for?It allows the dispensing system to be vented before first use without losing any reagent: air and excess volume go back into the stock bottle via the recirculation tube instead of into waste. This is particularly relevant with expensive or environmentally relevant solvents.How is the Analog version adjusted in the 5-50 ml range?Via Easy Calibration, without tools. A changed factory adjustment is indicated by a red marking on the device.Technical detailsVersionAnalogRecirculation valveyes, incl. recirculation tubeVolume range5-50 mlGraduation1 mlAccuracy (A)0.5 %/250 µlCoefficient of variation (CV)0.1 %/50 µlColour codeyellow (Organic)Valve springTantalumWetted materialsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter)Autoclavableyes, 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclaveThreadGL45Adapter/filling tubeAdapters: GL 32-33, GL 38, S 40; filling tube 170-330 mm; incl. recirculation tubeScope of delivery1 Dispensette S Organic bottle-top dispenser for GL45 threaded bottlesDischarge tube with recirculation valve, including recirculation tubeTelescopic filling tubeMounting keyBottle adapter matching the volume rangeQuality certificateOperating instructionsDistinction within the Dispensette S familyThe choice of series depends on the medium being dispensed: the Organic series (yellow) is intended for the organic solvents and acids listed above, and the standard Dispensette S (red) for alkaline solutions and most other acids. For trace analysis with a selectable valve spring of platinum-iridium or tantalum, the Dispensette S Trace Analysis is available separately.Individual requirements & procurement serviceIf additional accessories are needed, such as a bottle adapter for a different thread, spare valves or a longer filling tube, our procurement service can help.
Brand Dispensette S Organic bottle-top dispenser, Digital, 5-50 ml, with recirculation valve, DE-M, 4630361
When transferring larger quantities of organic solvents from the reservoir bottle, excess should not end up in the waste. The Brand Dispensette S Organic Digital with recirculation valve (5 to 50 ml) can be primed without reagent loss, excess volume returns via the recirculation tube. At 5-50 ml, the graduation is 0.2 ml, the accuracy is 0.5 %/250 µl, the coefficient of variation is 0.1 %/50 µl.Typical applicationsThe yellow colour code identifies the Organic series in the Brand range. Typical applications for 5-50 ml:Priming before transferring larger quantities of organic solvent, without reagent lossDispensing organic solvents in extraction steps with recirculation of excess volumeAdding concentrated hydrochloric acid in digestion procedures with subsequent loss-free replenishmentDigital version and selection guideThe volume is set via the volume setting wheel with a mechanical counter and can be quickly readjusted between individual dispensing steps. Digital instruments are adjustable without tools via Easy Calibration. Matching bottle adapters for GL 32-33, GL 38, S 40 are included, the filling tube can be adjusted to 170-330 mm.When transferring larger quantities of expensive solvents, the recirculation valve pays for itself through loss-free priming. For inexpensive routine media in the same range, the version without a recirculation valve is sufficient.Materials and autoclavabilityWetted parts consist of borosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter). The instrument is autoclavable under the following conditions: 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclave. Tantalum as valve spring material, together with the fluoroplastics ETFE, FEP, PFA and PTFE, makes the Organic series suitable for organic solvents and several concentrated acids, but not for alkalis and salt solutions.The Dispensette S Organic is not suitable for alkalis, salt solutions, carbon disulfide, explosive liquids and media that attack borosilicate glass such as hydrofluoric acid. For alkalis and salt solutions, the Dispensette S in red (standard) is the appropriate series, for trace analysis with a selectable valve spring made of platinum-iridium or tantalum, the Dispensette S Trace Analysis.Assembly and changing to another reservoir bottle are carried out using the supplied mounting key and the telescopic filling tube, which can be adjusted to the respective bottle height. The bottle adapter included in the scope of delivery fits the respective GL45-compatible thread and makes the dispenser usable independently of the specific reservoir bottle.Accuracy at a glanceFor 5-50 ml: graduation 0.2 ml, accuracy 0.5 %/250 µl, coefficient of variation 0.1 %/50 µl. The DE-M marking in the product name refers to conformity assessment under German weights and measures law; it does not replace a calibration certificate.Other volumes in the Digital versionIn addition to 5-50 ml, the Digital version of the Dispensette S Organic covers further ranges:VolumeAccuracyMPN (without recirculation valve)0.5-5 ml0.5 %/25 µl46303301-10 ml0.5 %/50 µl46303402.5-25 ml0.5 %/125 µl4630350Frequently asked questionsWhat is the recirculation valve used for?It allows priming of the dispensing system before the first use without reagent loss: air and excess volume return via the recirculation tube into the reservoir bottle instead of into the waste. This is particularly relevant with expensive or environmentally relevant solvents.How is the Digital version in the 5-50 ml range adjusted?Easy Calibration makes this possible without tools, an adjustment deviating from the factory setting is made visible by a red mark.Technical detailsVersionDigitalRecirculation valveyes, incl. recirculation tubeVolume range5-50 mlGraduation0.2 mlAccuracy (A)0.5 %/250 µlCoefficient of variation (CV)0.1 %/50 µlColour codeyellow (Organic)Valve springTantalumWetted materialsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter)Autoclavableyes, 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclaveThreadGL45Adapter/filling tubeAdapter: GL 32-33, GL 38, S 40; filling tube 170-330 mm; incl. recirculation tubeScope of delivery1 Dispensette S Organic bottle-top dispenser for GL45 threaded bottlesDischarge tube with recirculation valve, including recirculation tubeTelescopic filling tubeMounting keyBottle adapters suitable for the volume rangeQuality certificateOperating instructionsDifferentiation within the Dispensette S familyThose who, as here, work with organic solvents or concentrated hydrochloric acid and nitric acid are well served by the yellow Organic series, not by the red standard Dispensette S. For trace analysis with a selectable valve spring made of platinum-iridium or tantalum, the Dispensette S Trace Analysis is available separately.Individual requirements & procurement serviceFor suitable bottle adapters, spare parts such as valves or filling tubes as well as for further volume ranges from the Dispensette S Organic series, we provide support via our own procurement service.
Brand Dispensette S Bottle-Top Dispenser, Digital, 2.5-25 ml, without Recirculation Valve, DE-M, 4600350
Anyone in the laboratory who repeatedly needs to prepare larger quantities of buffer wants to be able to read the volume without estimating the scale by eye. With 2.5 to 25 ml, the Dispensette S Digital covers exactly this need and shows the set value on the mechanical counter. The colour code red stands for the standard version, suitable for a wide range of acids, alkalis and solvents, but not for hydrofluoric acid, hydrochloric acid above 20 % or nitric acid above 30 %.Distinction within the Dispensette S standard seriesCompared with the Fix version of the same series, the Digital variant allows the volume to be chosen freely within the stated range, read from the counter rather than from a scale as with Analog. For workstations with constantly changing target volumes this is the more practical route, whereas for a single fixed value the simpler Fix version is sufficient.Accuracy and graduationAccuracy is 0.5 %/125 µl, the coefficient of variation figure 0.1 %/25 µl, the graduation 0.1 ml. These values apply to all volumes set within the range 2.5 to 25 ml and were determined according to the general test procedure for piston-stroke devices.Digital counterThe digital counter allows fine, reproducible volume setting via the setting wheel. Unlike a Fix version, the volume can be chosen freely within the stated range, which saves time with changing batches in the same volume window because no second device is needed.Without recirculation valveThis version works without a recirculation valve. The design is therefore simpler, with one less moving part in the dispensing path. For applications where every dispensed volume goes directly into the target vessel and no return is needed, this slimmer design is sufficient.Mounting and handlingAfter screwing on the matching bottle adapter and shortening the telescopic filling tube to the bottle height, the next step is venting: draw in and dispense into a waste container several times until no more air bubbles are visible. The mounting key supplied is used for later valve changes.Media compatibilityThe red standard version tolerates a wide range of reagents: concentrated acids such as phosphoric acid and sulphuric acid, concentrated alkalis, salt solutions and numerous organic solvents. Excluded are hydrofluoric acid as well as hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids. Anyone who regularly dispenses concentrated hydrochloric or nitric acid should choose the yellow Dispensette S Organic; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe complete device is autoclavable: sterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours of cooling time in the closed device. This means the Dispensette S Digital can also be used where sterile conditions are required for reagent dispensing, for example with microbiological culture media.Frequently asked questionsCan the volume be set freely?Yes, the setting wheel allows any volume within the stated range to be set, and the counter shows the value currently set.Which bottle sizes fit the Dispensette S Digital?According to the accessories table, the adapters GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.For which work step is the volume range 2.5 to 25 ml intended?Typical uses include reagent addition for larger sample series, this volume range is intended for such applications.Typical applicationsPreparing larger quantities of bufferDilution series in the ml rangeReagent addition for larger sample seriesTechnical detailsLineBrand Dispensette S, DigitalVolume2.5 to 25 mlGraduation0.1 mlAccuracy0.5 %/125 µlCoefficient of variation0.1 %/25 µlRecirculation valvenoMedia compatibilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on screw cap and bottle adapterAutoclavabilitySterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours of cooling time in the closed deviceMarkingDE-MManufacturer article no.4600350Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tubeTelescopic filling tubeMounting keyBottle adapter matching the volumeQuality certificateOperating instructionsIndividual requirements and procurement serviceFor additional bottle adapters, replacement valves or further volumes from the Dispensette S Digital series, we provide support via our procurement service.
Brand Dispensette S bottle-top dispenser, Fix, 10 ml, with recirculation valve, DE-M, 4600241
Where dispensing a fixed volume in large series is required in the laboratory, an adjustable volume is not necessary, rather in the way. The Dispensette S Fix with 10 ml dispenses precisely this one volume, without a scale and without an Easy-Calibration function. Those wishing to eliminate accidental adjustment, for example with changing personnel at the workstation, benefit from this streamlined design. Like the other Dispensette S versions, the Fix is mounted directly on the reagent bottle and is part of the same standard series with a red colour code.Media compatibilityThe red standard version tolerates a wide spectrum of reagents: concentrated acids such as phosphoric acid and sulfuric acid, concentrated alkalis, salt solutions, and numerous organic solvents. Excluded are hydrofluoric acid as well as hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulfide, and explosive liquids. Anyone who regularly dispenses concentrated hydrochloric or nitric acid opts for the yellow Dispensette S Organic; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe entire instrument is autoclavable: sterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours cooling time in the closed instrument. For sterile workstations, such as in the preparation of microbiological culture media, the Dispensette S Fix can thus be resterilised before each batch.Fix or DigitalThose who switch between multiple volumes in daily operations are better served with Digital or Analog. The Fix is suitable where the same volume is required unchanged over long periods, for example in standardised routine procedures with fixed specifications.Accuracy without scaleAccuracy and coefficient of variation are 0.5 %/50 µl and 0.1 %/10 µl, respectively. There is no scale division on the Fix version; the fixed volume is factory-adjusted and is not set on the instrument. Those who nevertheless wish to check accuracy do so by gravimetric testing with an analytical balance; the procedure is independent of whether the volume is fixed or adjustable.Fixed volume instead of adjustment wheelDispensing with a counter and adjustment mechanism reduces the number of moving parts in the dispensing path. This makes handling easier than with the Digital version and is suitable for media addition with a constant target value, where changing the target volume does not occur anyway. Particularly with changing personnel at a workstation, the fixed volume reduces the source of error of an inadvertently misadjusted scale, because this scale simply does not exist on the Fix version.Recirculation functionWith the recirculation valve, dispensed liquid can be guided back into the supply bottle without removing the instrument. On a fixed-volume instrument, this is particularly useful when checking accuracy by gravimetric testing, because the dispensing process can be repeated without filling a new vessel each time.Mounting and handlingThe instrument is mounted using the appropriate bottle adapter, and the telescopic filling tube is cut to the height of the supply bottle. Before the first dispensing, the system is primed by repeatedly drawing up and dispensing into a waste vessel. The mounting key is included for subsequent valve replacement.Frequently asked questionsCan the volume on the Fix be changed subsequently?No, the volume is factory-adjusted and cannot be adjusted on the instrument, unlike with the Digital or Analog version of the same series.Which bottle sizes fit the Dispensette S Fix?According to the accessories table, the adapters GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be cut to the respective bottle height.Why 10 ml as a fixed volume and not an adjustable range?Because the operating step for which this instrument is intended permanently requires the same volume, the fixed volume saves an operating step compared to an adjustable version.Typical applicationsDispensing a fixed volume in large seriesMedia addition with constant target valueTechnical detailsLineBrand Dispensette S, FixVolume10 ml (fixed volume)Scale divisionnot present, fixed volume factory-adjustedAccuracy0.5 %/50 µlCoefficient of variation0.1 %/10 µlRecirculation valveyesMedia compatibilitystandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsborosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium, and PP on screw cap and bottle adapterAutoclavabilitysterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by around 2 hours cooling time in the closed instrumentMarkingDE-MManufacturer article no.4600241Scope of deliveryBottle-top dispenser for GL45 threaded bottlesDischarge tube including recirculation tubeTelescopic filling tubeMounting keyBottle adapters matching the volumeQuality certificateOperating instructionsIndividual requirements & procurement serviceFor other fixed volumes from the Dispensette S Fix series or suitable bottle adapters, we provide support via our procurement service.
Brand Dispensette S Organic bottle-top dispenser, Analog, 1-10 ml, without Recirculation Valve, DE-M, 4630140
For acid digestion using a fixed volume of concentrated hydrochloric or nitric acid, the setting does not need to be checked again for each sample. Once set, the Brand Dispensette S Organic Analog (1 to 10 ml) remains at the selected value. For volumes of 1-10 ml, the graduation is 0.2 ml, the accuracy is 0.5 %/50 µl, and the coefficient of variation is 0.1 %/10 µl.Typical applicationsThe colour code ‘Yellow’ identifies the Organic series within the Brand range. Typical applications for 1-10 ml:fixed dosing of concentrated hydrochloric acid in standardised digestion proceduresconsistent addition of organic solvents during liquid-liquid extractionrecurring addition of THF during standardised synthesis stepsAnalog version and selection guideThe volume is set using the volume adjustment screw with indicator arrow: loosen the screw by three-quarters of a turn, move the indicator arrow to the scale value, then tighten the screw again. Once set, the value remains fixed until deliberately adjusted. Analog instruments can be adjusted tool-free via Easy Calibration. Bottle adaptors for GL 24-25, GL28/S 28, GL 32-33, GL 38 and S 40 are included; the filling tube can be adjusted to 125-240 mm.For a digestion protocol requiring a consistent acid volume, the mechanical Analog version is sufficient. If the volume varies between sample series, the Digital version with a counter is more practical.Materials and autoclavabilityParts in contact with the medium are made of borosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum and PP (screw cap/bottle adapter). The device is autoclavable under the following conditions: 121 °C, 2 bar, for at least 15 minutes according to DIN EN 285, with a cooling time of approx. 2 hours in a closed autoclave. The use of tantalum as the valve spring material, together with the fluoroplastics ETFE, FEP, PFA and PTFE, makes the Organic series suitable for use with organic solvents and certain concentrated acids; however, it is not suitable for alkalis or saline solutions.The Dispensette S Organic is not suitable for alkalis, salt solutions, carbon disulphide, explosive liquids or media that attack borosilicate glass, such as hydrofluoric acid. For alkalis and salt solutions, the Dispensette S in red (standard) is the suitable series; for trace analysis with a selectable valve spring made of platinum-iridium or tantalum, the Dispensette S Trace Analysis is the suitable series.Installation and switching to a different stock bottle are carried out using the supplied mounting key and the telescopic filling tube, which can be adjusted to the height of the respective bottle. The bottle adapter included in the scope of delivery fits the relevant GL45-compatible thread, allowing the dispenser to be used regardless of the specific stock bottle.Accuracy at a glanceFor 1-10 ml: graduation 0.2 ml, accuracy 0.5 %/50 µl, coefficient of variation 0.1 %/10 µl. The DE-M marking in the product name refers to conformity assessment under German weights and measures law; it does not replace a calibration certificate.Other volumes in the Analog versionThe Analog version of the Dispensette S Organic covers further ranges in addition to 1-10 ml:VolumeAccuracyMPN (without recirculation valve)0.5-5 ml0.5 %/25 µl46301302.5-25 ml0.5 %/125 µl46301505-50 ml0.5 %/250 µl463016010-100 ml0.5 %/500 µl4630170Frequently asked questionsCan this version be retrofitted without a recirculation valve?According to the manufacturer, the version with a recirculation valve has its own order number and comes with its own discharge tube including a recirculation tube; it is not a retrofit option for the version without a recirculation valve.How is the Analog version adjusted in the 1-10 ml range?Easy Calibration allows this to be done without tools; any adjustment deviating from the factory setting is indicated by a red mark.Technical detailsVersionAnalogRecirculation valveNoVolume range1-10 mlGraduation0.2 mlAccuracy (R)0.5 %/50 µlCoefficient of variation (CV)0.1 %/10 µlColour codeyellow (Organic)Valve springTantalumMaterials in contact with the mediumBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter)AutoclavableYes, 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in a closed autoclaveThreadGL45Adapter/filling tubeAdapters: GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40; filling tube 125-240 mmScope of delivery1 Dispensette S Organic bottle-top dispenser for GL45-threaded bottlesDischarge tube without recirculation valveTelescopic filling tubeMounting keyBottle adaptor suitable for the relevant volume rangeQuality certificateOperating instructionsDifferentiation within the Dispensette S rangeFor the medium being dispensed here, the yellow Organic series is suitable. For alkalis or most other acids, the red Standard Dispensette S would be the suitable choice instead. For trace analysis, with a choice of valve spring made from platinum-iridium or tantalum, the Dispensette S Trace Analysis is available separately.Individual requirements and procurement serviceAny additional requirements for bottle adaptors, replacement valves or further volume ranges of the Dispensette S Organic can be arranged via our procurement service.
BRAND Dispensette S Analog, without recirculation valve, bottle-top dispenser (0.1 to 100 ml), 0.2 ml to 2 ml
The tried-and-tested standard: BRAND Dispensette S Analog (without back-dosing valve) The BRAND Dispensette S Analog is used for dispensing directly from the laboratory bottle. In this standard version (without back-dispensing valve), it is robustly built. It is suitable for applications where the venting volume is not critical or is routinely discarded. S-Class: Safe, Fast, Simple The ‘S’ generation has been optimised to make everyday laboratory work easier: Analogue adjustment: The volume is set using a mechanical slider on the scale. An internal rack and pinion mechanism locks the setting securely in place: nothing shifts, even when subjected to vibrations. Minimal operating force required: Aspiration and discharge are noticeably easier than with previous models. This reduces physical strain, particularly during long dispensing runs. Direct dispensing: This version features a single discharge channel. Dispensing takes place immediately after the cylinder has been filled. Universal chemical resistance (colour code: red) The Dispensette S Analog is suitable for a very wide range of media, including: Corrosive acids: e.g. H₃PO₄, H₂SO₄ (conc.), HCl. Alkalis: e.g. NaOH, KOH. Salt solutions & buffers. Polar solvents: e.g. ethanol, methanol, acetylacetone. (Note: This unit is not suitable for hydrofluoric acid (HF); for this, you will need the Trace Analysis version.) Robust construction The device does not use sealing rings on the piston (floating piston system), which minimises wear and prevents crystallisation. For cleaning or sterilisation, the dispenser is fully autoclavable at 121 °C without the need for disassembly. Technical data Model: Dispensette S Analogue Version: Standard (without recirculation valve) Adjustment type: Analogue (slider control) Volume range: 0.2 ml to 2 ml Materials in contact with the medium: borosilicate glass, Al₂O₃ ceramic, platinum-iridium, ETFE, FEP, PFA, PP (screw cap) Operating limits: Vapour pressure: max. 600 mbar Viscosity: max. 500 mm²/s Temperature: max. +40 °C Density: max. 2.2 g/cm³ Autoclavable: Yes, completely (121 °C) DE-M marking under German measurement and verification law: Yes Scope of delivery 1 x BRAND Dispensette S Analog (volume 0.2 ml to 2 ml) 1 x discharge tube (standard, without valve) 1 x telescopic filling tube (length-adjustable, suitable for the nominal volume) 1 x mounting key 1 x adapter set for various bottle threads (polypropylene) (For 1, 2, 5, 10 ml: GL 24 to 25, GL 28/S 28, GL 32 to 33, GL 38) (For 25, 50, 100 ml: GL 32 to 33, GL 38, S 40) 1 x quality certificate 1 x user guide Individual requirements & accessories Do you require laboratory bottles or spare parts? Bottle holder: A bottle holder is recommended, particularly for small volumes (1 to 5 ml) in small bottles, to ensure they stand securely. Drying tubes: A drying tube (available separately) can be connected for media sensitive to moisture or CO₂. Please contact our procurement service.
Brand Dispensette S bottle-top dispenser, Fix, 1 ml, without recirculation valve, DE-M, 4600210
Where recurring addition of the exact same small volume is required in the laboratory, an adjustable volume is not necessary, rather getting in the way. The Dispensette S Fix with 1 ml dispenses precisely this one volume, without a scale and without an Easy-Calibration function. Anyone wishing to eliminate accidental adjustment, for example with changing personnel at the workstation, benefits from this reduced design. Like the other Dispensette S versions, the Fix is mounted directly on the reagent bottle and is part of the same standard series with a red colour code.Fixed volume instead of adjustment wheelOmitting a counter and adjustment mechanism reduces the number of moving parts in the dispensing path. This makes handling easier than with the digital version and is suitable for reagent addition in routine analysis without risk of adjustment, where changing the target volume does not occur anyway. Especially with changing personnel at a workstation, the fixed volume reduces the source of error of an accidentally incorrectly set scale, because this scale simply does not exist on the Fix version.Without recirculation valveWithout a recirculation valve, the design is reduced to the essentials. For a fixed-volume instrument that always dispenses the same quantity anyway, this simpler design is completely sufficient in many routines.Mounting and handlingThe Dispensette S Fix is screwed onto the stock bottle using the supplied bottle adapter, and the telescopic filling tube can be cut to the appropriate length. Before first use, the system is primed several times and discharged into a waste container until no air bubbles are visible. The mounting key included in the scope of delivery is used for valve replacement.Media compatibilityThe red standard version tolerates a wide spectrum of reagents: concentrated acids such as phosphoric acid and sulfuric acid, concentrated alkalis, saline solutions, and numerous organic solvents. Excluded are hydrofluoric acid as well as hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulfide, and explosive liquids. Anyone who regularly dispenses concentrated hydrochloric or nitric acid can opt for the yellow Dispensette S Organic; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.AutoclavabilityThe entire instrument is autoclavable: sterilisation according to DIN EN 285: 121 °C, 2 bar, hold time at least 15 minutes, followed by around 2 hours cooling time in the closed instrument. For sterile workplaces, for instance in the preparation of microbiological culture media, the Dispensette S Fix can thus be resterilised before each batch.Fix or DigitalIf a workstation occasionally requires a different volume within the same range, a Dispensette S Digital with an adjustable counter or an Analog version with a scale on the cylinder is the more suitable choice. The Fix has advantages where a volume is permanently fixed: fewer operating steps and no risk of adjustment.Accuracy without a scaleAccuracy and coefficient of variation are 0.5 %/5 µl and 0.1 %/1 µl respectively. There is no scale division on the Fix version, the fixed volume is factory-adjusted and is not set on the instrument. Anyone who nevertheless wishes to check the accuracy does so by gravimetric testing with an analytical balance, the procedure is independent of whether the volume is fixed or adjustable.Frequently asked questionsCan the volume on the Fix be changed subsequently?No, the volume is factory-adjusted and cannot be adjusted on the instrument, unlike the Digital or Analog versions of the same series.Which bottle sizes fit the Dispensette S Fix?According to the accessories table, the adapters GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be cut to the respective bottle height.Why 1 ml as a fixed volume and not an adjustable range?Because the work step for which this instrument is intended permanently requires the same volume, the fixed volume saves an operating step compared to an adjustable version.Typical applicationsrepetitive addition of the same small volumereagent addition in routine analysis without risk of adjustmentTechnical detailsLineBrand Dispensette S, FixVolume1 ml (fixed volume)Scale divisionnone, fixed volume factory-adjustedAccuracy0.5 %/5 µlCoefficient of variation0.1 %/1 µlRecirculation valvenoMedia compatibilitystandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %Materials of wetted partsborosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium, and PP on screw cap and bottle adapterAutoclavabilitysterilisation according to DIN EN 285: 121 °C, 2 bar, hold time at least 15 minutes, followed by around 2 hours cooling time in the closed instrumentMarkingDE-MManufacturer article no.4600210Scope of deliverybottle-top dispenser for GL45 threaded bottlesdischarge tubetelescopic filling tubemounting keybottle adapter matching the volumequality certificateoperating instructionsIndividual requirements & procurement serviceFor other fixed volumes from the Dispensette S Fix series or suitable bottle adapters, we provide support through our procurement service.
Brand Dispensette S Organic bottle-top dispenser, Analog, 2.5-25 ml, with recirculation valve, DE-M, 4630151
For a fixed reaction volume with tetrahydrofuran or concentrated nitric acid, priming the analog version should not waste any reagent. The Brand Dispensette S Organic Analog with recirculation valve (2.5 to 25 ml) returns excess volume via the recirculation tube. At 2.5-25 ml, the graduation is 0.5 ml, the accuracy is 0.5 %/125 µl, and the coefficient of variation is 0.1 %/25 µl.Typical applicationsThe yellow colour code identifies the Organic series in the Brand range. Typical applications for 2.5-25 ml:priming before preparing fixed THF reaction volumes, without loss of reagentrecurrent addition of concentrated nitric acid with recirculation of excess volumeAnalog version and selection guideThe volume is set via the volume setting screw with indicator pointer: loosen the screw by three-quarters of a turn, slide the indicator pointer to the scale value, tighten the screw again. Once set, the value remains fixed until intentionally changed. Analog instruments can be adjusted without tools via Easy Calibration. Bottle adapters for GL 32-33, GL 38, S 40 are included, and the filling tube can be adjusted to 170-330 mm.For a fixed but expensive solvent volume, the recirculation valve saves reagent during daily priming. For inexpensive standard media, the version without recirculation valve is sufficient.Materials and autoclavabilityWetted parts consist of borosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter). The instrument is autoclavable under the following conditions: 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclave. Tantalum as valve spring material together with the fluoroplastics ETFE, FEP, PFA and PTFE makes the Organic series suitable for organic solvents and some concentrated acids, but not for alkalis and salt solutions.The Dispensette S Organic is not suitable for alkalis, salt solutions, carbon disulfide, explosive liquids and media that attack borosilicate glass, such as hydrofluoric acid. For alkalis and salt solutions, the Dispensette S in red (standard) is the appropriate series, for trace analysis with a selectable valve spring made of platinum-iridium or tantalum, the Dispensette S Trace Analysis.Mounting and changing to a different supply bottle are carried out using the supplied mounting key and the telescopic filling tube, which can be adjusted to the respective bottle height. The bottle adapter included in the scope of delivery fits the respective GL45-compatible thread and makes the dispenser usable independently of the specific supply bottle.Accuracy at a glanceFor 2.5-25 ml: graduation 0.5 ml, accuracy 0.5 %/125 µl, coefficient of variation 0.1 %/25 µl. The DE-M marking in the product name refers to conformity assessment under German weights and measures law; it does not replace a calibration certificate.Other volumes in the analog versionIn addition to 2.5-25 ml, the analog version of the Dispensette S Organic covers further ranges:VolumeAccuracyMPN (without recirculation valve)0.5-5 ml0.5 %/25 µl46301301-10 ml0.5 %/50 µl46301405-50 ml0.5 %/250 µl463016010-100 ml0.5 %/500 µl4630170Frequently asked questionsWhat is the recirculation valve used for?It allows priming of the dispensing system before the first use without losing reagent: air and excess volume return to the supply bottle via the recirculation tube instead of into the waste. This is particularly relevant for expensive or environmentally relevant solvents.How is the analog version adjusted in the 2.5-25 ml range?Easy Calibration makes this possible without tools, an adjustment deviating from the factory setting is made visible by a red mark.Technical detailsVersionAnalogRecirculation valveyes, incl. recirculation tubeVolume range2.5-25 mlGraduation0.5 mlAccuracy (A)0.5 %/125 µlCoefficient of variation (CV)0.1 %/25 µlColour codeyellow (Organic)Valve springtantalumWetted materialsborosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter)Autoclavableyes, 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclaveThreadGL45Adapter/filling tubeadapters: GL 32-33, GL 38, S 40; filling tube 170-330 mm; incl. recirculation tubeScope of delivery1 Dispensette S Organic bottle-top dispenser for GL45 threaded bottlesdischarge tube with recirculation valve, including recirculation tubetelescopic suction tubemounting toolbottle adapters suitable for the volume rangequality certificateoperating instructionsDifferentiation within the Dispensette S familyThe Organic series (yellow) is designed for the media described here. For alkalis or other acids outside this list, the standard Dispensette S (red) is the correct series. For trace analysis with a selectable valve spring made of platinum-iridium or tantalum, the Dispensette S Trace Analysis is available separately.Individual requirements & procurement serviceFor bottle adapters, spare parts and other volume ranges of the Dispensette S Organic, our procurement service is available.