Skip to main content Skip to search Skip to main navigation

Brand Dispensette S Bottle-Top Dispenser, Fix, 5 ml, with recirculation valve, DE-M, 4600231

ⓘ  This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.

Product information "Brand Dispensette S Bottle-Top Dispenser, Fix, 5 ml, with recirculation valve, DE-M, 4600231"

Where a buffer is always added in the same quantity, an adjustable volume is not needed and tends to get in the way. The Dispensette S Fix with 5 ml dispenses exactly this one volume, without a scale and without the Easy-Calibration function. Anyone who wants to rule out accidental adjustment, for example when staff change at a workstation, benefits from this reduced design. Like the other Dispensette S versions, the Fix is mounted directly on the reagent bottle and belongs to the same standard series with the red colour code.

Fixed volume instead of an adjustment wheel

Dispensing with no counter and no adjustment mechanism reduces the number of moving parts in the dispensing path. This makes handling simpler than with the Digital version and suits routine filling of a fixed volume in quality control, where changing the target volume never happens anyway. Especially when staff change at a workstation, the fixed volume reduces the risk of an incorrectly set scale, because the Fix version simply has no scale.

Recirculation function

With the recirculation valve, dispensed liquid can be returned to the reservoir bottle without removing the device. On a fixed-volume device this is mainly useful when checking accuracy by back-weighing, because the dispensing cycle can be repeated without filling a new vessel each time.

Assembly and handling

Initial set-up begins with screwing on the bottle adapter and shortening the telescopic filling tube to the height of the bottle. Dispensing into a waste vessel is then repeated several times until there are no more air bubbles in the system. The supplied mounting tool is used for later valve replacement.

Media suitability

The red standard version tolerates a wide range of reagents: concentrated acids such as phosphoric acid and sulphuric acid, concentrated alkaline solutions, salt solutions and numerous organic solvents. Excluded are hydrofluoric acid as well as hydrochloric acid above 20 %, nitric acid above 30 %, THF, trifluoroacetic acid, carbon disulphide and explosive liquids. Anyone who regularly dispenses concentrated hydrochloric or nitric acid should choose the yellow Dispensette S Organic; for hydrofluoric acid, Brand recommends the Dispensette S Trace Analysis with platinum-iridium valve spring.

Autoclavability

The complete device is autoclavable: sterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by about 2 hours of cooling time in the closed device. For sterile workplaces, for example when preparing microbiological culture media, the Dispensette S Fix can therefore be re-sterilised before every batch.

Fix or Digital

For changing volumes within the same range, the Digital version with counter or the Analog version with scale is the better choice. If, on the other hand, it is certain that only this one volume will ever be needed, the Fix saves operating steps and avoids accidental adjustment.

Accuracy without a scale

Accuracy and coefficient of variation are 0.5 %/25 µl and 0.1 %/5 µl respectively. The Fix version has no scale graduation; the fixed volume is adjusted at the factory and is not set on the device. Anyone who still wants to check the accuracy does so by back-weighing with an analytical balance; the procedure is the same whether the volume is fixed or adjustable.

Frequently asked questions

Can the volume of the Fix be changed afterwards?
No, the volume is adjusted at the factory and cannot be set on the device, unlike the Digital or Analog version of the same series.

Which bottle sizes fit the Dispensette S Fix?
According to the accessories table, the adapters GL 24-25, GL28/S 28, GL 32-33, GL 38, S 40 fit. The telescopic filling tube can be shortened to the respective bottle height.

Why 5 ml as a fixed volume and not an adjustable range?
Because the work step this device is intended for always needs the same volume, the fixed volume saves one operating step compared with an adjustable version.

Typical applications

  • Adding a buffer in the same quantity every time
  • Routine filling of a fixed volume in quality control

Technical details

SeriesBrand Dispensette S, Fix
Volume5 ml (fixed volume)
Scale graduationnot present, fixed volume adjusted at the factory
Accuracy0.5 %/25 µl
Coefficient of variation0.1 %/5 µl
Recirculation valveyes
Media suitabilityStandard version, red, not for hydrofluoric acid, hydrochloric acid above 20 %, nitric acid above 30 %
Materials of wetted partsBorosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, platinum-iridium and PP on the screw cap and bottle adapter
AutoclavabilitySterilisation according to DIN EN 285: 121 °C, 2 bar, holding time at least 15 minutes, followed by about 2 hours of cooling time in the closed device
MarkingDE-M
Manufacturer part no.4600231

Scope of delivery

  • Bottle-top dispenser for GL45 threaded bottles
  • Discharge tube including recirculation tube
  • Telescopic filling tube
  • Mounting tool
  • Bottle adapter matching the volume
  • Quality certificate
  • Operating instructions

Individual requirements & procurement service

For further fixed volumes from the Dispensette S Fix series or suitable bottle adapters, we provide support via our own procurement service.

Display type: Fixed
Operation: mechanical
Recirculation valve: with recirculation valve
Volume range: 5 ml (fixed)
Volume setting: fixed