Brand Dispensette S Organic bottle-top dispenser, Analog, 10-100 ml, with recirculation valve, DE-M, 4630171
€618.00
- Volume range 10-100 ml
- Analog version, Easy Calibration
- with recirculation valve, including recirculation tube
- Colour code yellow, for organic solvents and concentrated HCl/HNO3
- Accuracy 0.5 %/500 µl, coefficient of variation 0.1 %/100 µl
- Tantalum valve spring
- autoclavable at 121 °C, 2 bar, min. 15 minutes
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Brand Dispensette S Organic bottle-top dispenser, Analog, 10-100 ml, with recirculation valve, DE-M, 4630171"
With large batches of up to 100 ml of organic solvent, venting before the first dispensing should not cost any reagent. The Brand Dispensette S Organic Analog with recirculation valve (10 to 100 ml) returns excess volume to the stock bottle via the recirculation tube. At 10-100 ml the graduation is 1 ml, the accuracy is 0.5 %/500 µl and the coefficient of variation is 0.1 %/100 µl.
Typical applications
The yellow colour code identifies the Organic series in the Brand range. For 10-100 ml, in practice these include:
- Venting before dispensing large batches of organic solvent, without reagent loss
- large-volume decanting with excess volume returned in cleaning steps
Analog version and selection guide
The volume is set using the volume adjustment screw with indicator arrow: loosen the screw by three quarters of a turn, slide the indicator arrow to the scale value, and tighten the screw again. Once set, the value stays until deliberately changed. Analog devices can be adjusted without tools via Easy Calibration. Matching bottle adapters for GL 32-33, GL 38, S 40 are included, and the filling tube can be adjusted to 170-330 mm.
With large volumes of expensive solvents, the recirculation valve is particularly noticeable through loss-free venting. For inexpensive media in the same range, the version without recirculation valve is sufficient.
Materials and autoclavability
Wetted parts are made of borosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter). The device is autoclavable under the following conditions: 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclave. Tantalum as the valve spring material, together with the fluoroplastics ETFE, FEP, PFA and PTFE, makes the Organic series suitable for organic solvents and some concentrated acids, but not for alkaline solutions and salt solutions.
The Dispensette S Organic is not suitable for alkaline solutions, salt solutions, carbon disulphide, explosive liquids and media that attack borosilicate glass, such as hydrofluoric acid. For alkaline solutions and salt solutions, the Dispensette S in red (standard) is the suitable series, and for trace analysis with a selectable valve spring of platinum-iridium or tantalum, the Dispensette S Trace Analysis.
Assembly and changing to a different stock bottle are done with the supplied mounting key and the telescopic filling tube, which can be adjusted to the respective bottle height. The bottle adapter included in the scope of delivery fits the respective GL45-compatible thread and makes the dispenser usable regardless of the specific stock bottle.
Accuracy at a glance
For 10-100 ml: graduation 1 ml, accuracy 0.5 %/500 µl, coefficient of variation 0.1 %/100 µl. The DE-M marking in the product name refers to conformity assessment under German weights and measures law; it does not replace a calibration certificate.
Other volumes in the Analog version
If you need a range other than 10-100 ml, you will find it within the Analog version of the Dispensette S Organic:
| Volume | Accuracy | MPN |
| 0.5-5 ml | 0.5 %/25 µl | 4630130 (without recirculation valve), 4630131 (with recirculation valve) |
| 1-10 ml | 0.5 %/50 µl | 4630140 (without recirculation valve), 4630141 (with recirculation valve) |
| 2.5-25 ml | 0.5 %/125 µl | 4630150 (without recirculation valve), 4630151 (with recirculation valve) |
| 5-50 ml | 0.5 %/250 µl | 4630160 (without recirculation valve), 4630161 (with recirculation valve) |
Frequently asked questions
What is the recirculation valve needed for?
It allows the dispensing system to be vented before first use without losing any reagent: air and excess volume go back into the stock bottle via the recirculation tube instead of into waste. This is particularly relevant with expensive or environmentally relevant solvents.
How is the Analog version adjusted in the 10-100 ml range?
With Easy Calibration this can be done without additional tools; a changed factory adjustment is shown by a red marking.
Technical details
| Version | Analog |
| Recirculation valve | yes, incl. recirculation tube |
| Volume range | 10-100 ml |
| Graduation | 1 ml |
| Accuracy (A) | 0.5 %/500 µl |
| Coefficient of variation (CV) | 0.1 %/100 µl |
| Colour code | yellow (Organic) |
| Valve spring | Tantalum |
| Wetted materials | Borosilicate glass, Al2O3 ceramic, ETFE, FEP, PFA, PTFE, tantalum, PP (screw cap/bottle adapter) |
| Autoclavable | yes, 121 °C, 2 bar, at least 15 minutes according to DIN EN 285, cooling time approx. 2 hours in the closed autoclave |
| Thread | GL45 |
| Adapter/filling tube | Adapters: GL 32-33, GL 38, S 40; filling tube 170-330 mm; incl. recirculation tube |
Scope of delivery
- 1 Dispensette S Organic bottle-top dispenser for GL45 threaded bottles
- Discharge tube with recirculation valve, including recirculation tube
- Telescopic filling tube
- Mounting key
- Bottle adapter matching the volume range
- Quality certificate
- Operating instructions
Distinction within the Dispensette S family
For the medium dispensed here, the yellow Organic series is suitable. For alkaline solutions or most other acids, the red standard Dispensette S would be the suitable choice instead. For trace analysis with a selectable valve spring of platinum-iridium or tantalum, the Dispensette S Trace Analysis is available separately.
Individual requirements & procurement service
Additional requirements for bottle adapters, spare valves or further volume ranges of the Dispensette S Organic can be clarified via our procurement service.
| Display type: | Analogue |
|---|---|
| Operation: | mechanical |
| Recirculation valve: | with recirculation valve |
| Volume range: | 10 ml - 100 ml |
| Volume setting: | variable |