Skip to main content Skip to search Skip to main navigation

Brand Titrette Bottle-Top Burette, 25 ml, with RS232 Interface, DE-M, 4760251

Product information "Brand Titrette Bottle-Top Burette, 25 ml, with RS232 Interface, DE-M, 4760251"

The Titrette 25 ml with an RS232 interface has the same error limit as the standard version, but also features a data interface. This allows the titration value to be transferred directly to a PC or a titration log, rather than having to type it out from the display.

RS232 instead of manual transfer

The 25 ml model is also used where titration results are documented electronically. Via the RS232 interface, the consumption value can be transferred directly to a PC without having to copy it manually from the display.

Error limits of the 25 ml version

For 25 ml, Brand specifies an accuracy of 0.07 % / 18 µl and a coefficient of variation of 0.025 % / 6 µl, identical to the Titrette without a PC interface in the same volume range. The RS232 interface does not affect dosing accuracy; it merely extends the output of the measured value.

Typical applications

  • Routine titrations with electronic recording of the consumption value
  • Connection to titration or LIMS software via the serial interface
  • Quality assurance with documented, traceable measurement results
  • Workstations carrying out several titration runs per day, where manual data transfer is time-consuming

Selection guide: RS232 for the 25 ml volume range

With the 25 ml model, an electronic connection to LIMS or Excel analysis via RS232 is often worthwhile. Those who do not require data transfer can save on additional costs by opting for the standard version without a PC interface; 10 ml and 50 ml options are available for smaller or larger consumption volumes. In laboratories with strict quality requirements, this allows for seamless documentation of which consumption value corresponds to which sample, without the risk of transcription errors.

Titrette RS232 versus glass burette and Dispensette

A 25 ml Class A glass burette requires the value read to be transferred manually to the log; the Titrette RS232 transmits it directly. The Titrette also differs from a Dispensette in its operating principle: a fixed repeat dose as opposed to continuous accumulation up to the end point. This accumulation is at the heart of titration: it is not a fixed volume that counts, but the volume consumed up to the point at which the reaction reaches the end point, and it is precisely this point that the RS232 interface records electronically.

Technical details

Volume range25 ml
Accuracy0.07 % / 18 µl
Coefficient of variation0.025 % / 6 µl
PC interfaceRS232
Connection threadGL45
MarkingDE-M
Power supply2 AAA/UM4/LR03 micro batteries

Use and maintenance

The Titrette screws directly onto the stock bottle of the titrant via one of the three PP bottle adaptors supplied (GL 32, S 40, NS 29/32); the telescopic filling tube can be adjusted to bottle heights between 170 and 330 mm. Before first use and after each bottle change, the system must be vented, as with any piston burette, to ensure that no air bubbles in the cylinder affect the dosing accuracy. The recirculation tube allows any accidentally dispensed excess titrant to be returned to the bottle, rather than having to restart the titration. Two brown-tinted light-protection windows shield light-sensitive titrants without the need to cover the bottle completely. The counter is powered by two AAA/UM4/LR03 micro-batteries, which can be replaced without tools as soon as the display indicates a low battery voltage. A mains connection is not required; the device remains operational even at workstations without a socket.

Scope of delivery

  • Titrette bottle-top burette for GL45-threaded bottles
  • Marked DE-M
  • Quality certificate
  • Telescopic filling tube, 170 to 330 mm
  • Recirculation tube
  • 2 micro batteries (AAA/UM4/LR03)
  • 3 PP bottle adaptors (GL 32, S 40, NS 29/32)
  • 2 brown-tinted light-protection windows

Frequently asked questions

  • What data does the RS232 interface output? The titration consumption value, according to the manufacturer, for direct transfer to a PC or analysis software.
  • How accurately does the Titrette dispense 25 ml via RS232? Accuracy: 0.07 % or 18 µl; coefficient of variation: 0.025 % or 6 µl, identical to the version without a PC interface.
  • Which bottle threads are compatible with the Titrette? GL45 directly; via a PP adapter, also GL 32, S 40 and NS 29/32.
  • What is included in the scope of delivery? The Titrette with RS232 interface, telescopic filling tube, recirculation tube, three bottle adaptors, two micro-batteries and a quality certificate.

Individual requirements and procurement service

You can enquire about suitable bottle adaptors, replacement filling tubes or other accessories for the Titrette range on our service page. Contact us via our procurement service.

Operation: mechanical
Volume range: 25 ml (fixed)
Volume setting: variable