Skip to main content Skip to search Skip to main navigation

IKA PETTE vario 1-10 ml single-channel pipette, variable, autoclavable, 0020011218

ⓘ  This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.

Product information "IKA PETTE vario 1-10 ml single-channel pipette, variable, autoclavable, 0020011218"

Anyone who switches between different volumes in the laboratory does not reach for a separate pipette for each quantity. With an adjustable range of 1,000 to 10,000 µl in 10 µl steps, the IKA PETTE vario 1-10 ml covers the largest volume range of the PETTE vario series. As an air cushion pipette with mechanical operation, it works without a battery or power supply. The red-coded device weighs only 108 grams and can be fully autoclaved at 121 °C.

Variable volume from 1 to 10 millilitres

The nominal volume is 10,000 µl, and the setting can be varied between 1,000 and 10,000 µl in steps of 10 µl each. At nominal volume, the accuracy according to IKA (ISO 8655) is ±60 µl or ±0.6 %, and the precision is ±15 µl or ±0.15 %. At 50 % of the nominal volume (5,000 µl), accuracy and precision are ±40 µl (±0.8 %) and ±10 µl (±0.2 %), and at 10 % of the nominal volume (1,000 µl) they are ±30 µl (±3 %) and ±6 µl (±0.6 %).

Autoclavable for sterile applications

The piston is made of PPSU, a plastic that withstands repeated autoclave cycles at 121 °C. This allows the pipette to be sterilised completely instead of only changing the tip, which is relevant in microbiological or cell-culture-related work when cross-contamination between different batches has to be ruled out. Unlike pipettes that can only be sterilised at the tip cone, the complete device can be placed in the autoclave here.

Ergonomics through interchangeable handles

Three interchangeable handles of different shape and different material are included in the scope of delivery. Anyone who uses the pipette over longer periods or at high frequency can thus choose the handle that sits most comfortably for their own hand and way of working, instead of adapting to a single fixed shape. Especially in serial work with many consecutive pipetting operations, a suitable handle shape makes itself felt in the wrist. At a weight of only 108 grams and dimensions of 30 x 222 x 63 mm, the pipette remains light and handy overall.

Typical applications

With a volume range of 1 to 10 ml, the PETTE vario mainly covers larger dispensing volumes for which smaller pipettes would need several strokes:

  • Preparing and diluting larger reagent quantities in routine analysis
  • Precise variable dispensing in the range of 1 to 10 ml for different applications
  • Preparation of sterile batches with subsequent autoclaving of the pipette
  • Use in laboratories with a documented calibration obligation according to ISO 8655
  • Production of dilution series in the millilitre range for sample preparation

Selection guide: volume ranges of the PETTE vario series

The PETTE vario is available from IKA in several volume ranges, which differ in nominal volume and setting range but all work on the same mechanical operating principle.

Volume rangeMPN
0.1 to 2 µl0020011210
0.5 to 10 µl0020011211
2 to 20 µl0020011213
10 to 100 µl0020011214
20 to 200 µl0020011215
100 to 1,000 µl0020011216
0.5 to 5 ml0020011217
1 to 10 ml (this product)0020011218

For larger volumes such as preparing buffers or dilutions, the 1 to 10 ml version described here is suitable, and for microlitre ranges one of the smaller volume ranges from the same series is recommended. All variants share the same mechanical operating principle and the same autoclavability, so a laboratory with several volume ranges can rely on a uniform operating concept.

Technical details

DesignAir cushion pipette, air cushion
Operationmechanical
Volumevariable, 1,000 to 10,000 µl
Number of channels1
Colour codeRed
Nominal volume10,000 µl
Increment10 µl
Accuracy at nominal volume±60 µl / ±0.6 %
Precision at nominal volume±15 µl / ±0.15 %
Accuracy at 50 % of nominal volume±40 µl / ±0.8 %
Precision at 50 % of nominal volume±10 µl / ±0.2 %
Accuracy at 10 % of nominal volume±30 µl / ±3 %
Precision at 10 % of nominal volume±6 µl / ±0.6 %
Standardaccording to ISO 8655
Autoclavableyes, at 121 °C
Piston materialPPSU
Permissible ambient temperature range5 to 40 °C
Permissible relative humidity90 %
Dimensions (W x H x D)30 x 222 x 63 mm
Weight0.108 kg

Scope of delivery

  • 1 x IKA PETTE vario 1-10 ml
  • 3 x interchangeable handles (different shapes and materials)

Pipette tips are not included in the scope of delivery and are procured separately to suit the volume range.

Distinction from the neighbouring series

If the same volume is always pipetted, a fixed-volume pipette from the IKA PETTE fix series is often the simpler choice, for example the version with 1,000 µl fixed volume. Anyone who wants to fill several wells of a microtitre plate at the same time will find the multichannel series with the PETTE multi 12-channel as the suitable alternative. All pipettes in the range are grouped together in the category Pipettes.

Calibration and autoclaving

Unlike with electronic pipettes, disposal through the collection of waste electrical equipment does not apply to the PETTE vario, as it is a purely mechanical device without electronics. For documented calibration according to ISO 8655, the IKA calibration software IPCS is available, with which test results can be recorded and evaluated directly. When autoclaving, the temperature of 121 °C specified by the manufacturer applies as the upper limit. After the cycle, the pipette should cool down and dry completely before its next use. Between calibration intervals, a visual inspection for damage to the piston and tip cone is advisable, especially after frequent autoclaving.

Individual requirements & procurement service

In addition to suitable tips (Tip xl, as bag or box) and filter tips, further handle variants for the PETTE vario such as PETTE.GR.1 and PETTE.GR.45 as well as the IPCS calibration software are also available. Even for larger order quantities for entire laboratory teams, it is worth consulting us, for example to procure volume ranges and handle variants uniformly across the team. Do you need a different volume range from the PETTE vario series, a specific handle or support with calibration? Our procurement service supports you with procurement and configuration.

Frequently asked questions

Which volume range can be set?
1,000 to 10,000 µl (1 to 10 ml) in steps of 10 µl, the nominal volume is 10,000 µl.

Is the pipette autoclavable?
Yes, fully at 121 °C, the piston is made of the autoclavable plastic PPSU.

Are pipette tips included in the scope of delivery?
No, tips are procured separately to suit the volume range.

How accurate is the pipette at nominal volume?
According to IKA (ISO 8655), the accuracy is ±60 µl or ±0.6 % and the precision is ±15 µl or ±0.15 %. At 10 % of the nominal volume, both values widen in relative terms to ±3 % and ±0.6 % respectively, which has to be taken into account for very small partial volumes within the range.

How many handles are included?
Three interchangeable handles of different shape and different material for different hand sizes and ways of working.

Does the pipette need batteries or a power supply?
No, the PETTE vario works purely mechanically as an air cushion pipette, without an electrical connection.

How often should the pipette be calibrated?
The manufacturer does not specify a fixed interval. Calibration according to ISO 8655 at regular intervals defined in the QM system is usual, supported by the IKA calibration software IPCS.

Skip product gallery

Matching pipette tips

Discount
IKA Tip xl 10 ml Pipettenspitzen für IKA PETTE 1-10 ml
IKA Tip xl 10 ml Pipette Tips for IKA PETTE 1-10 ml

The IKA PETTE vario 1-10 ml covers the upper volume range of the IKA pipette family and needs a correspondingly sized tip for it. IKA Tip xl tips are transparent, fitted with calibration rings and designed for the millilitre range up to 10 ml. They come in a bag for ongoing use and in a box for ordered removal at the bench.The bag provides 1000 tips in ten packs of 100. The box provides 250 tips sorted compactly for daily use at the pipetting station. Both packaging forms are non-sterile, transparent and made of autoclavable polypropylene. The large tip opening suits transferring and dosing larger liquid volumes, for example when preparing stock solutions or growth media.CompatibilityOfficial accessory for the IKA PETTE vario 1-10 ml (0020011218). The tips also fit the IKA PETTE MacroKit (0010014029), which covers the range from 100 µl to 10 ml.Technical detailsIKA Tip xl bag1000 pcs. (10 x 100), non-sterile, transparent, with calibration rings, autoclavable polypropyleneIKA Tip xl box250 pcs./box, non-sterile, transparent, with calibration rings, autoclavable polypropyleneScope of delivery1 x IKA Tip xl packaging unit in the selected version (bag or box).Individual requirements & procurement serviceFor smaller volumes we also carry the matching IKA Tip l tips for the IKA PETTE 0.5-5 ml and the IKA Tip 1000 µl tips for the IKA PETTE 100-1,000 µl. Our procurement service advises on the right packaging form for your sample throughput.

Variants from €130.50
Sale price: €137.75 Manufacturer's RRP: €145.00 5% below manufacturer's RRP
Skip product gallery

Fits

Discount
IKA Inkubationsschüttler KS 4000 ic control (mit Kühlung)
IKA KS 4000 ic control Incubating Shaker (with Cooling Coil for External Recirculating Chiller), 0003510100
Manufacturer number: 0003510100

Anyone who lets cell cultures or microbiological samples shake unattended overnight needs temperature control that also works below room temperature. The IKA KS 4000 ic control combines an orbital shaking motion with PID-controlled heating up to 80 °C and a built-in cooling coil. Together with an externally connected circulation chiller, the 90 litre internal chamber reaches temperatures down to room temperature minus 10 °C. Without this chiller, the device works as an incubating shaker with heating, entirely without active cooling.PID control from minus 10 to 80 °CTwo PT1000 temperature sensors and an integrated PID controller hold the set temperature with a setting accuracy of 0.1 K. With a vessel containing 0.5 litre of water, 22 °C room temperature and 37 °C set temperature, the control accuracy is ±0.5 K and the temperature stability is ±0.05 K. With 0.2 litre of water at 25 °C room temperature and 37 °C set temperature, the stability falls to ±0.1 K. Spread over five vessels of 0.5 litre each, the homogeneity in the interior is ±0.5 K. A large LED display shows speed and temperature, and an additional connection socket in the working space takes a further PT1000 sensor, for example the supplied PT 1000.60 made of stainless steel.Cooling coil and external circulation chiller belong togetherThe KS 4000 ic control has no compressor of its own and no refrigerant circuit of its own. The built-in cooling coil needs an externally connected circulation chiller, and IKA names models such as the RC 2 lite, the RC 2 basic or the RC 2 control for this. We also offer the IKA RC 5 control for this purpose, with 1,400 watt cooling capacity down to minus 30 °C. Without a connected chiller, the temperature range remains limited to room temperature up to 80 °C. Anyone who knows from the outset that work will only be done above room temperature saves the chiller and chooses the comparable KS 4000 i control (ident no. 0003510000), which has no cooling coil.20 kilograms shaking load at 20 millimetre orbitThe orbital motion has a shaking stroke of 20 millimetres and carries up to 20 kilograms of shaking material including attachment. The speed ranges from 10 to 500 revolutions per minute, adjustable in steps of 1 rpm, with a deviation of ±5 rpm. The motor draws 82 watts and delivers 24 watts, designed for a duty cycle of 100 %. The electronic timer covers 0 to 999 hours, optionally in timer or continuous operation, with a 7-segment LED display for the remaining time.Safety and everyday operationIn the event of a fault, the device switches off automatically, and likewise when the hood is opened during operation. The controls have an antimicrobial coating, and a drip tray with a drain hose at the back of the device catches spilled liquid. Via the RS-232 interface, the KS 4000 ic control can be connected to the laboratory device software labworldsoft, for documenting temperature, speed and time. The housing is made of powder-coated sheet steel, the polyester front film.Typical applicationsMicrobiological cultures with a cooling requirement below room temperatureCell cultivation with tight tolerances for temperature stability and homogeneityUnmonitored shaking operation overnight or over the weekendDocumented temperature control via labworldsoft in quality-assured laboratoriesTechnical detailsType of motionorbital, shaking stroke 20 mmPermissible shaking weight (incl. attachment)20 kgSpeed range10 to 500 rpm, steps 1 rpm, deviation ±5 rpmMotor power input / output82 W / 24 WHeating power1,000 WTemperature range (with external circulation chiller)Room temp. -10 °C to 80 °CControl accuracy / stability (0.5 l, 37 °C)±0.5 K / ±0.05 KHomogeneity (5 vessels 0.5 l, 37 °C)±0.5 KTimerelectronic, 0 to 999 h, timer and continuous operationWorking area internal chamber (W x H x D)440 x 440 x 352 mmTotal volume internal chamber90 lHousing material / front filmPowder-coated sheet steel / polyester filmRS 232 interfaceyesIP ratingIP 30 (DIN EN 60529)Dimensions (W x H x D)580 x 520 x 750 mmWeight55 kgConnected load230 V, 50/60 Hz, 1,120 W, fuse 2x T10A 250VScope of delivery1 x KS 4000 ic control1 x PT 1000.60 temperature sensor, stainless steel4 x clamping screws short (for fixing the attachment)2 x clamping screws long (for fixing the attachment)Attachments such as the universal attachment or retaining clips are not included and must be ordered together with the device to suit the application. An external circulation chiller for the cooling function is likewise not part of the scope of delivery.Regulatory informationThis device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer, IKA, is DE 66784213. Information on the return of old appliances can be found on our page Environment and disposal.Selection guide and serviceIf you need a smaller internal chamber, the KS 3000 ic control (ident no. 0003940100) offers the same cooling principle with a built-in cooling coil, but only 50 litres of volume, a permissible shaking weight of up to 7.5 kilograms and an additional USB-B interface. IKA grants a manufacturer's warranty of 2 years for the KS 4000, extended to 5 years with registration at ika.com/register within 90 days of purchase. As an electrical device, the KS 4000 ic control falls under the WEEE directive and must not be disposed of with household waste at the end of its life. Via our procurement service, circulation chillers, attachments and further accessories can be ordered together to suit the application.

Sale price: €6,729.00 Manufacturer's RRP: €8,972.00 25% below manufacturer's RRP