ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Memmert base frame B33509, 130 mm high, for HCP240 humidity chamber"
The base frame B33509 is 130 mm high and intended for the HCP240 humidity chamber. According to Memmert, for size 240 it can only be used for stacked units together with the B48129 stacking kit. The levelling base frame with a height of 622 mm is available as B33506.
The Memmert Humidity Chamber HCP240 is the largest version of the HCP series: 241 litres of internal volume, up to twelve shelves, 140 kg permissible total load. The housing measures 759 x 1,180 x 691 mm externally plus 56 mm door handle, and the interior 600 x 810 x 500 mm (depth less 35 mm for the fan). The chamber sets +18 to +90 °C and 20 to 95 % rh, optionally with rh-Off, and is controlled via the ControlCOCKPIT TwinDISPLAY.Weight, dimensions and connectionAt approx. 110 kg net weight, the HCP240 is the heaviest HCP. Connection is with 230 V and 50/60 Hz at approx. 1,840 W. Two stainless steel perforated trays are inserted from the factory, and 15 kg apply per shelf. The interior is made of stainless steel 1.4301 (ASTM 304). A heated inner glass door sits behind the fully insulated stainless steel door, which closes with 2-point locking. In the rear wall (centre left), a humidity-tight silicone feedthrough with 40 mm inner diameter leads supply lines into the interior, and a silicone plug closes it.Humidification and dehumidificationHumidification is from an external container with a self-priming pump. A water canister and the connection hose are included in the scope of delivery. An integrated germ barrier uses hot steam generation, and a sterile filter takes care of dehumidification. The water must be demineralised or fully deionised, with 5 to 10 µS/cm and a pH value of 5 to 7. Setting accuracy: 0.5 % rh for humidity, 0.1 °C for temperature. To avoid condensate formation, door and rear wall are additionally heated, in addition to the all-round heating on six sides. We will tell you about further options for the water supply on request.Programs, calibration values and languagesAtmoCONTROL writes and transfers programs via Ethernet or USB. Three freely selectable values each for temperature and humidity can be calibrated. The countdown clock is set between 1 minute and 99 days, and SetpointWAIT begins the process time only at the setpoint temperature. Temperature appears in Celsius or Fahrenheit, and there are also time zones and the changeover between summer and winter time. Operation is possible in nine languages, including German, English, Spanish, French and Italian. After a power failure, the saved program sequence is available.Alarm and self-diagnosisThe Pt100 sensors (two of them, DIN class A, 4-wire measurement) check each other, and if one sensor fails, the other continues to work. The AutoSAFETY monitoring "ASF" follows the setpoint at an interval that can be freely selected. Exceeding and falling below trigger a visual and acoustic alarm, and when exceeded the heating also switches off. The self-diagnosis system serves to find faults in temperature and humidity control. Permissible are 10 to 30 °C room temperature at a maximum of 70 % rel. humidity without condensation and an installation altitude up to 2,000 m above sea level. Also to be observed are at least 15 cm distance to the rear wall, 20 cm to the ceiling and 5 cm at the sides.Placement in the HCP seriesThe next smaller HCP150 has 156 l, ten shelves and 120 kg total load. The HCP240 is above it with 241 l, twelve shelves and 140 kg. For more volume or operation near or below room temperature, the ICH260 climate chamber is the alternative from a different series: 256 l, setting temperature range -10 to +60 °C, humidity 10 to 80 % rh in the range +10 to +60 °C. The HCP240, by contrast, reaches up to +90 °C and up to 95 % rh.Typical applicationsThe HCP series is intended for the following areas of use:Environmental testingEnvironmental simulationsAccelerated lifetime tests85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78Technical detailsInternal volume241 lInternal dimensions (W x H x D)600 x 810 x 500 mm (D less 35 mm for fan)External dimensions (W x H x D)759 x 1,180 x 691 mm (D plus 56 mm door handle)Weight (net)approx. 110 kgShelvesup to 12, 2 perforated trays in scope of deliveryLoad capacity140 kg total, 15 kg per shelfTemperature range (setting)+18 to +90 °CTemperature range (working range)7 °C above room temperature to +90 °CTemperature accuracy (setting)0.1 °CHumidity range (setting)20 to 95 % rh and rh-OffHumidity accuracy (setting)0.5 % rhSensors2x Pt100, DIN class A, 4-wire measurement, redundantControlTwinDISPLAY, PID microprocessor controller with 2 TFT colour graphic displaysWaterdemineralised or fully deionised, 5 to 10 µS/cm, pH 5 to 7Voltage and power230 V, 50/60 Hz, approx. 1,840 WData connectionsEthernet LAN, USBOperating environment10 to 30 °C, max. 70 % rel., non-condensing, up to 2,000 m above sea levelMarkingCE, VDE GS, cMETusOther sizes in the seriesThe HCP series comprises four sizes, and the HCP240 is at the upper end:ModelInternal volumeSetting temperatureHumidity rangeHCP5056 l+18 to +90 °C20 to 95 % rhHCP105107 l+18 to +90 °C20 to 95 % rhHCP150156 l+18 to +90 °C20 to 95 % rhHCP240 (this page)241 l+18 to +90 °C20 to 95 % rhScope of deliveryMemmert Humidity Chamber HCP240Stainless steel perforated tray, 2 piecesFactory calibration certificate for 60 °C at 75 % rh (measuring room centre of usable space)Heated inner glass doorFully insulated stainless steel door, 2-point locking (compression door lock)Silicone feedthrough, humidity-tight, 40 mm inner diameter, rear wall, centre leftWater canister with connection hoseRegulatory informationThe unit is an electrical device within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer Memmert GmbH + Co. KG is DE 66812464. Notes on returning old appliances can be found on our page Environment and disposal.Individual requirements and procurement serviceFor the HCP240, factory options are available that are specified when ordering, as well as accessories and calibration and qualification services. We coordinate the current scope with Memmert on request. Tell us how you want to use the chamber, and we will advise you personally and prepare a non-binding quotation. As factory options, Memmert also offers DAkkS calibration according to DKD-R 5-7, IQ/OQ documents and IQ/OQ qualification. We order these with the device on request.