N₂ pressure-reducing valve according to DIN EN ISO 2503
Including gas cylinder monitor
For ICO NextGen CO₂ incubators
Suitable for 4 Memmert models in sizes 50, 105, 180 and 240
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Memmert N₂ pressure-reducing valve E61022 for CO₂ incubator ICO, option T6 required"
The N₂ pressure-reducing valve E61022 requires option T6. It is made according to DIN EN ISO 2503 and is supplied including a gas cylinder monitor. It is intended for the ICO NextGen CO₂ incubators in sizes 50, 105, 180 and 240. The size corresponds to the number in the unit name, for example ICO50 or ICO105.
The table shows the compatible models.
Typical applications
Typical uses in the compatible units:
Entry into active humidity or O₂ control via options K7 and T6, for example in the ICO50
Microbiological, pharmaceutical and biotechnological research requiring documented climate conditions, for example in the ICO105
Incubation of larger sample quantities or several test series at the same time, for example in the ICO180
Pre-order: The ICO50 is part of the new ICO NextGen generation. It is available as a pre-order.
The Memmert ICO50 NextGen CO₂ incubator offers an internal volume of 56 litres within a compact footprint. This makes it the entry point into the new NextGen platform for laboratories that regularly incubate cell cultures without sacrificing too much floor space. The series completely replaces the previous ICO generation from 2012, featuring a new operating concept and updated model sizes.
One touchscreen instead of two displays
Whereas the previous generation featured two separate TFT displays, the ICO50 NextGen combines actual and target values, as well as parameter trends, on a single 6.86-inch IPS touchscreen with multi-touch functionality (480 x 1280 pixels). Temperature, CO₂ and the optional humidity and O₂ readings are thus displayed on a single screen rather than two.
Temperature and CO₂ control
The temperature can be set from +20 to +50 °C; the operating range extends from at least 5 °C above room temperature up to +50 °C, with a setting accuracy of 0.1 °C. At 37 °C, the temporal temperature fluctuation is ±0.1 K, and the spatial fluctuation is ±0.3 K. CO₂ control covers 0 to 20 % CO₂ as standard, with a setting accuracy of 0.1 % and a temporal fluctuation of ±0.2 % CO₂. Temperature and CO₂ are the two parameters that can be controlled as standard on the ICO50.
Humidity and O₂ as an extension
The scope of delivery includes a stainless-steel water tray. Users wishing to actively control relative humidity can upgrade with Option K7 to a range of 40 to 98 % rh, including a rh cut-off function, with a setting accuracy of 0.1 % rh. Humidification is handled by a self-priming micro-dosing pump with a hot steam generator, whilst dehumidification is managed by a diaphragm pump; the unit also features an integrated self-diagnostic system with audible and visual fault indicators. For hypoxic applications, Option T6 (requires Option K7) controls the oxygen concentration via nitrogen injection within the range of 1 to 20 % O₂, with an accuracy of 0.1 %.
Sterilisation without removing sensors
A pre-programmed cycle sterilises the interior in 60 minutes at +180 °C without the need to remove the sensors beforehand. This saves time in day-to-day laboratory work between two different culture batches.
Inner chamber, door and shelves
The deep-drawn interior is made of stainless steel grade 1.4301 (ASTM 304). The fully insulated stainless steel door closes with a 2-point compression lock and features an internal glass door. A stainless steel perforated shelf is supplied as standard; up to 4 shelves can be fitted, with a maximum load of 15 kg per shelf and 50 kg per unit. According to the manufacturer, a glass door option (K4) is not available for the ICO50, unlike the larger models ICO105, ICO180 and ICO240.
Interfaces and software
The ICO50 NextGen features USB-C and Ethernet LAN. The chargeable software application myChamber LIMS is available for connection to a LIMS or other data management system, whilst the connectivity package for the myChamber Monitoring App is available for permanent remote monitoring. Users requiring electronic signatures according to 21 CFR Part 11 of the US FDA can add the FDAQ1 basic licence for AtmoCONTROL FDA and myChamber Control FDA. None of the three software options are included as standard.
Operation and connected load specifications
The ICO50 NextGen is rated for 230 V, 50/60 Hz; Option X2 converts it to 115 V at no extra cost. Power consumption is approximately 1,200 W. The textured stainless steel housing measures 548 x 628 x 519 mm (width x height x depth), plus an additional 50 mm for the door handle. The internal dimensions are 400 x 425 x 330 mm. The net weight is 53 kg; when packed, it weighs 66 kg.
Other sizes in the ICO NextGen series
In addition to the ICO50 (56 litres), we offer the ICO105 (108 litres), the ICO180 (177 litres, successor to the previous ICO150) and the ICO240 (243 litres), each featuring the same operating concept and the same control parameters.
Typical applications
With controlled temperature and CO₂ concentration, the ICO50 NextGen is suitable for:
Routine incubation of cell cultures at individual workstations or in smaller laboratories
Microbiological and cell biology research where space is limited
Laboratory operations involving frequent changes of culture batches, thanks to the built-in sterilisation function
Getting started with active humidity or O₂ control via the K7 and T6 options
Technical details
Internal volume56 litres
Internal dimensions (W x H x D)400 x 425 x 330 mm (depth minus 37.5 mm for the fan)
Cabinet dimensions (W x H x D)548 x 628 x 519 mm (plus 50 mm door handle)
Interior materialStainless steel grade 1.4301 (ASTM 304), deep-drawn
Temperature setting range+20 to +50 °C
Operating temperature rangeat least 5 °C above room temperature up to +50 °C
Temperature accuracy0.1 °C (temporal variation at 37 °C ±0.1 K, spatial ±0.3 K)
CO₂ control0 to 20 % CO₂, accuracy 0.1 %, temporal variation ±0.2 % CO₂
Humidity control (Option K7)40 to 98 % rh and rh-Off, accuracy 0.1 % rh
O₂ control (Option T6, requires K7)1 to 20 % O₂, accuracy 0.1 %
Control unit6.86" IPS touchscreen (480 x 1280 pixels), multi-touch
DoorFully insulated stainless steel door, 2-point locking, internal glass door
Shelves1x stainless steel perforated shelf as part of the scope of delivery, up to 4 possible
Max. load50 kg total / 15 kg per shelf
Installation4 adjustable feet
InterfacesUSB-C, Ethernet LAN
Factory calibration certificate+37 °C, 5 % CO₂ (standard; with option K7 additionally 90 % rh, with K7 and T6 additionally 10 % O₂)
Voltage/Power230 V, 50/60 Hz, approx. 1,200 W (Option X2: 115 V at no extra cost)
Net weight/Gross weight53 kg / 66 kg
Scope of delivery
1x Memmert ICO50 NextGen CO₂ incubator (basic unit)
1x stainless steel perforated shelf
1x stainless steel water tray
1x CO₂ connection set (hose with connector and hose clamp)
1x factory calibration certificate (+37 °C, 5 % CO₂)
Not included in the scope of delivery: active humidity control (Option K7), O₂ control (Option T6) and the water canister with connection hose (only when Option K7 is ordered) are additional options, as are the software licences for myChamber LIMS, the Monitoring App and FDAQ1.
Regulatory information
Manufacturer’s WEEE registration number (Memmert GmbH + Co. KG, Stiftung EAR): DE 66812464. The ICO50 NextGen is not a medical device. Memmert is discontinuing the separate, previous ICOmed medical device series (last order 6 November 2026); according to Memmert, the ICO NextGen is currently undergoing testing and qualification to also meet the requirements for medical applications; this is an announcement, not an approval that has already been granted.
Individual requirements and procurement service
Memmert units bought from us are covered for three years from delivery: the first 12 months are followed by a 24-month warranty under Memmert’s terms, handled through us. Your statutory rights remain unaffected. Our procurement service is available to assist you with additional stainless steel perforated shelves, the K7 (active humidity control) or T6 (O₂ control) options, a stacking kit for two ICO50 units of the same size, or a bespoke calibration. As factory options, Memmert also offers DAkkS calibration according to DKD-R 5-7, IQ/OQ documents and IQ/OQ qualification. We order these with the device on request.
Pre-order: The ICO105 is part of the new ICO NextGen series. It is available as a pre-order.
With an internal volume of 108 litres, the Memmert ICO105 NextGen CO₂ incubator is a medium-sized model in the new NextGen series, offering, according to Memmert, one litre more capacity than the previous ICO105 from the 2012 generation. For laboratories that incubate several culture batches in parallel or require more space than the entry-level ICO50 offers, this size provides ample capacity without having to opt for the next larger model straight away.
A touchscreen instead of two separate screens
Instead of the previous TwinDISPLAY with two separate TFT screens, the ICO105 NextGen displays actual and target values as well as parameter trends on a 6.86-inch IPS touchscreen with multi-touch functionality (480 x 1280 pixels).
Temperature and CO₂ control
The temperature can be set from +20 to +50 °C; the operating range extends from at least 5 °C above room temperature up to +50 °C, with a setting accuracy of 0.1 °C. At 37 °C, the temporal temperature fluctuation is ±0.1 K, and the spatial fluctuation is ±0.3 K. CO₂ control covers 0 to 20 % CO₂ as standard, with a setting accuracy of 0.1 % and a temporal fluctuation of ±0.2 % CO₂.
Humidity and O₂ as an extension
A stainless-steel water tray is supplied as standard. Option K7 extends the ICO105 to include active humidity control from 40 to 98 % rh, including a ‘rh off’ function, with a setting accuracy of 0.1 % rh, utilising a self-priming micro-dosing pump with a hot steam generator for humidification and a diaphragm pump for dehumidification. Option T6 (requires Option K7) additionally controls the oxygen concentration via nitrogen injection in the range 1 to 20 % O₂, with an accuracy of 0.1 %.
Glass doors and battery storage as additional options
Unlike the smaller ICO50, the ICO105 offers Option K4: two internal doors with glass panels instead of the solid stainless-steel door, which is practical for a quick glance inside the unit without altering the internal climate. Also available as an option is an integrated battery storage unit (Option C2), which allows the display unit to continue operating without interruption in the event of a power cut, ensuring seamless documentation of all parameters even during a power cut.
Sterilisation without removing sensors
A pre-programmed cycle sterilises the interior in 60 minutes at +180 °C without the need to remove the sensors beforehand.
Interior, door and shelves
The deep-drawn interior is made of stainless steel grade 1.4301 (ASTM 304). The fully insulated stainless steel door closes with a 2-point compression lock and features an internal glass door. A stainless steel perforated shelf is supplied as standard; up to 5 shelves can be fitted, with a maximum load of 15 kg per shelf and 75 kg per unit.
Interfaces and software
The ICO105 NextGen features USB-C and Ethernet LAN. The chargeable software application myChamber LIMS is available for connection to a LIMS, whilst the connectivity package for the myChamber Monitoring App is available for permanent remote monitoring. For electronic signatures according to 21 CFR Part 11, the basic licence FDAQ1 for AtmoCONTROL FDA and myChamber Control FDA can be added. None of the three options is included as standard.
Operation and connected load specifications
The ICO105 NextGen is rated for 230 V, 50/60 Hz; Option X2 converts it to 115 V at no extra cost, and the power consumption is approximately 1,450 W. The textured stainless steel housing measures 708 x 683 x 589 mm (width x height x depth), plus a 50 mm allowance for the door handle; the internal dimensions are 560 x 480 x 400 mm. The net weight is 70 kg; when packed, it weighs 85 kg.
Other sizes in the ICO NextGen series
In addition to the ICO105 (108 litres), we offer the ICO50 (56 litres) for smaller batches, as well as the ICO180 (177 litres, according to Memmert the successor to the previous ICO150) and the ICO240 (243 litres) for higher throughput, each featuring the same operating concept.
Typical applications
With controlled temperature and CO₂ concentration, as well as an optional glass door, the ICO105 NextGen is suitable for:
Parallel incubation of multiple culture batches in medium-sized laboratories
Microbiological, pharmaceutical and biotechnological research requiring documented environmental conditions
Laboratory operations where visual monitoring via glass doors (Option K4) reduces the change in climate when the door is opened
Processes requiring complete documentation even in the event of a power cut (Option C2)
Technical details
Internal volume108 litres
Internal dimensions (W x H x D)560 x 480 x 400 mm (depth minus 37.5 mm for the fan)
Cabinet dimensions (W x H x D)708 x 683 x 589 mm (plus 50 mm door handle)
Interior materialStainless steel grade 1.4301 (ASTM 304), deep-drawn
Temperature setting range+20 to +50 °C
Operating temperature rangeat least 5 °C above room temperature up to +50 °C
Temperature accuracy0.1 °C (temporal variation at 37 °C ±0.1 K, spatial ±0.3 K)
CO₂ control0 to 20 % CO₂, accuracy 0.1 %, temporal variation ±0.2 % CO₂
Humidity control (Option K7)40 to 98 % rh and rh-Off, accuracy 0.1 % rh
O₂ control (Option T6, requires K7)1 to 20 % O₂, accuracy 0.1 %
Control unit6.86" IPS touchscreen (480 x 1280 pixels), multi-touch
DoorFully insulated stainless steel door, 2-point locking, internal glass door (optional: 2 doors with glass cut-outs, Option K4)
Shelves1x stainless steel perforated shelf as part of the scope of delivery, up to 5 possible
Max. load75 kg total / 15 kg per shelf
Installation4 adjustable feet
InterfacesUSB-C, Ethernet LAN
Factory calibration certificate+37 °C, 5 % CO₂ (standard; with option K7 additionally 90 % rh, with K7 and T6 additionally 10 % O₂)
Voltage/Power230 V, 50/60 Hz, approx. 1,450 W (Option X2: 115 V at no extra charge)
Net weight/Gross weight70 kg / 85 kg
Scope of delivery
1x Memmert ICO105 NextGen CO₂ incubator (basic unit)
1x stainless steel perforated shelf
1x stainless steel water tray
1x CO₂ connection set (hose with connector and hose clamp)
1x factory calibration certificate (+37 °C, 5 % CO₂)
Not included in the scope of delivery: active humidity control (Option K7), O₂ control (Option T6), glass doors (Option K4), the battery storage unit (Option C2) and the water canister with connection hose (only when Option K7 is ordered) are additional options, as are the software licences for myChamber LIMS, the Monitoring App and FDAQ1.
Regulatory information
Manufacturer’s WEEE registration number (Memmert GmbH + Co. KG, Stiftung EAR): DE 66812464. The ICO105 NextGen is not a medical device. Memmert is discontinuing the separate, previous ICOmed medical device series (last order 6 November 2026); according to Memmert, the ICO NextGen is currently undergoing testing and qualification to also meet the requirements for medical applications; this is an announcement, not an approval that has already been granted.
Individual requirements and procurement service
Memmert units bought from us are covered for three years from delivery: the first 12 months are followed by a 24-month warranty under Memmert’s terms, handled through us. Your statutory rights remain unaffected. Our procurement service can assist you with additional stainless steel perforated shelves, the K7, T6, K4 or C2 options, a stacking set for two ICO105 units of the same size (item no. B72335) or a bespoke calibration. As factory options, Memmert also offers DAkkS calibration according to DKD-R 5-7, IQ/OQ documents and IQ/OQ qualification. We order these with the device on request.
Pre-order: The ICO180 is part of the new ICO NextGen range. It is available as a pre-order.
The Memmert ICO180 NextGen CO₂ incubator takes the place of the previous ICO150 in the new size range, but with an internal volume of 177 litres, it offers significantly more space than its predecessor, which had a volume of 156 litres. Those who have previously used the ICO150 for larger sample quantities will find the ICO180 offers noticeably more space, whilst occupying a comparable position between the medium-sized ICO105 and the large ICO240.
A touchscreen instead of two displays
Instead of the previous TwinDISPLAY with two separate TFT screens, the ICO180 NextGen displays actual and target values as well as parameter trends on a 6.86-inch IPS touchscreen with multi-touch functionality (480 x 1280 pixels).
Temperature and CO₂ control
The temperature can be set from +20 to +50 °C; the operating range extends from at least 5 °C above room temperature up to +50 °C, with a setting accuracy of 0.1 °C. At 37 °C, the temporal temperature fluctuation is ±0.1 K, and the spatial fluctuation is ±0.3 K. CO₂ control covers 0 to 20 % CO₂ as standard, with a setting accuracy of 0.1 % and a temporal fluctuation of ±0.2 % CO₂.
Humidity and O₂ as an extension
A stainless-steel water tray is supplied as standard. Option K7 extends the ICO180 to include active humidity control from 40 to 98 % rh, including a ‘rh off’ function, with a setting accuracy of 0.1 % rh, utilising a self-priming micro-dosing pump with a hot steam generator for humidification and a diaphragm pump for dehumidification. Option T6 (requires Option K7) additionally controls the oxygen concentration via nitrogen injection in the range 1 to 20 % O₂, with an accuracy of 0.1 %.
Six shelves and two glass doors optional
With up to 6 possible shelves, the ICO180 offers more loading flexibility than the smaller models in the series; 2 stainless steel perforated shelves are supplied as standard. Option K4 equips the interior with two glass-panelled doors instead of the solid stainless steel door, allowing a quick view inside the unit without completely altering the internal climate. An integrated battery storage unit (Option C2) keeps the display unit running without interruption in the event of a power cut, ensuring seamless documentation even during an outage.
Sterilisation without removing sensors
A pre-programmed cycle sterilises the interior in 60 minutes at +180 °C without the need to remove the sensors beforehand.
Interior and door
The deep-drawn interior is made of stainless steel grade 1.4301 (ASTM 304). The fully insulated stainless steel door closes with a 2-point compression lock and features an internal glass door; maximum load: 15 kg per shelf and 90 kg per unit.
Interfaces and software
The ICO180 NextGen features USB-C and Ethernet LAN. The chargeable software application myChamber LIMS is available for connection to a LIMS, whilst the connectivity package for the myChamber Monitoring App is available for permanent remote monitoring. For electronic signatures according to 21 CFR Part 11, the basic licence FDAQ1 for AtmoCONTROL FDA and myChamber Control FDA can be added. None of the three options is included as standard.
Operation and connected load specifications
The ICO180 NextGen is rated for 230 V, 50/60 Hz; Option X2 converts it to 115 V at no extra charge, and the power consumption is approximately 1,550 W. The textured stainless steel housing measures 748 x 793 x 689 mm (width x height x depth), plus a 50 mm allowance for the door handle; the internal dimensions are 600 x 590 x 500 mm. The net weight is 98 kg; when packed, it weighs 116 kg. Anyone wishing to stack two ICO180 units on top of one another can use a stacking kit (item no. B64732) or a mobile stacking kit with a raised base (item no. B68476).
Other sizes in the ICO NextGen series
In addition to the ICO180 (177 litres), we offer the ICO50 (56 litres) and the ICO105 (108 litres) for smaller batches, as well as the ICO240 (243 litres) for the highest throughput, each featuring the same operating concept.
Typical applications
With its large internal volume, controlled temperature and CO₂ concentration, the ICO180 NextGen is suitable for:
Incubation of larger sample volumes or multiple experimental runs simultaneously
Microbiological, pharmaceutical and biotechnological research with higher throughput
Laboratory operations where glass doors (Option K4) allow visual monitoring without a complete change in the internal climate
Stacked configuration of multiple units where floor space is limited (stacking kit accessory)
Technical details
Internal volume177 litres
Internal dimensions (W x H x D)600 x 590 x 500 mm (depth minus 37.5 mm for the fan)
Cabinet dimensions (W x H x D)748 x 793 x 689 mm (plus 50 mm door handle)
Interior materialStainless steel grade 1.4301 (ASTM 304), deep-drawn
Temperature setting range+20 to +50 °C
Operating temperature rangeat least 5 °C above room temperature up to +50 °C
Temperature accuracy0.1 °C (temporal variation at 37 °C ±0.1 K, spatial ±0.3 K)
CO₂ control0 to 20 % CO₂, accuracy 0.1 %, temporal variation ±0.2 % CO₂
Humidity control (Option K7)40 to 98 % rh and rh-Off, accuracy 0.1 % rh
O₂ control (Option T6, requires K7)1 to 20 % O₂, accuracy 0.1 %
Control unit6.86" IPS touchscreen (480 x 1280 pixels), multi-touch
DoorFully insulated stainless steel door, 2-point locking, internal glass door (optional: 2 doors with glass cut-outs, Option K4)
Shelves2x stainless steel perforated shelves included in the scope of delivery, up to 6 possible
Max. load90 kg total / 15 kg per shelf
Installation4 adjustable feet
InterfacesUSB-C, Ethernet LAN
Factory calibration certificate+37 °C, 5 % CO₂ (standard; with option K7 additionally 90 % rh, with K7 and T6 additionally 10 % O₂)
Voltage/Power230 V, 50/60 Hz, approx. 1,550 W (Option X2: 115 V at no extra cost)
Net weight/Gross weight98 kg / 116 kg
Scope of delivery
1x Memmert ICO180 NextGen CO₂ incubator (basic unit)
2x stainless steel perforated shelves
1x stainless steel water tray
1x CO₂ connection set (hose with connector and hose clamp)
1x factory calibration certificate (+37 °C, 5 % CO₂)
Not included in the scope of delivery: active humidity control (Option K7), O₂ control (Option T6), glass doors (Option K4), battery storage (Option C2), stacking kits and the water canister with connection hose (only when option K7 is ordered) are additional options, as are the software licences for myChamber LIMS, the Monitoring App and FDAQ1.
Regulatory information
Manufacturer’s WEEE registration number (Memmert GmbH + Co. KG, Stiftung EAR): DE 66812464. The ICO180 NextGen is not a medical device. Memmert is discontinuing the separate, previous ICOmed medical device series (last order 6 November 2026); according to Memmert, the ICO NextGen is currently undergoing testing and qualification to also meet the requirements for medical applications; this is an announcement, not an approval that has already been granted.
Individual requirements and procurement service
Memmert units bought from us are covered for three years from delivery: the first 12 months are followed by a 24-month warranty under Memmert’s terms, handled through us. Your statutory rights remain unaffected. Our procurement service can assist you with additional stainless steel perforated shelves, the K7, T6, K4 or C2 options, a stacking kit for stacking two ICO180 units on top of one another, or a bespoke calibration. As factory options, Memmert also offers DAkkS calibration according to DKD-R 5-7, IQ/OQ documents and IQ/OQ qualification. We order these with the device on request.
Pre-order: The ICO240 is part of the new ICO NextGen series. It is available as a pre-order.
With an internal volume of 243 litres, the Memmert ICO240 NextGen CO₂ incubator is the largest model in the new series, offering two litres more capacity than the previous ICO240 from the 2012 generation. With up to 9 possible shelves, it is suitable for laboratories with high sample throughput or multiple users who load the same incubator simultaneously.
A touchscreen display instead of two screens
Instead of the previous ControlCOCKPIT TwinDISPLAY with two separate TFT screens, the ICO240 NextGen displays actual and setpoint values as well as parameter trends on a 6.86-inch IPS touchscreen with multi-touch functionality (480 x 1280 pixels).
Temperature and CO₂ control
The temperature can be set from +20 to +50 °C; the operating range extends from at least 5 °C above room temperature to +50 °C, with a setting accuracy of 0.1 °C. At 37 °C, the temporal temperature fluctuation is ±0.1 K, and the spatial fluctuation is ±0.3 K. CO₂ control covers 0 to 20 % CO₂ as standard, with a setting accuracy of 0.1 % and a temporal fluctuation of ±0.2 % CO₂.
Humidity and O₂ as an extension
A stainless-steel water tray is supplied as standard. Option K7 extends the ICO240 to include active humidity control from 40 to 98 % rh, including a ‘rh off’ function, with a setting accuracy of 0.1 % rh, utilising a self-priming micro-dosing pump with a hot steam generator for humidification and a diaphragm pump for dehumidification. Option T6 (requires Option K7) additionally controls the oxygen concentration via nitrogen injection in the range 1 to 20 % O₂, with an accuracy of 0.1 %.
Nine shelves and three glass doors optional
With up to 9 possible shelves, the ICO240 has the largest loading capacity in the series; 2 stainless steel perforated shelves are included as standard, with a maximum load of 15 kg per shelf and 135 kg per unit in total. Option K4 equips the interior with three glass-panelled doors instead of the solid stainless steel door, the highest number in the series for this size, which is practical when several users wish to keep an eye on different areas without having to open the entire door every time. An integrated battery storage unit (Option C2) keeps the display unit running without interruption in the event of a power cut.
Sterilisation without removing sensors
A pre-programmed cycle sterilises the interior in 60 minutes at +180 °C without the need to remove the sensors beforehand. This simplifies switching between different culture batches in day-to-day laboratory work.
Interior and door
The deep-drawn interior is made of stainless steel grade 1.4301 (ASTM 304). The fully insulated stainless steel door closes with a 2-point compression lock and features an internal glass door.
Interfaces and software
The ICO240 NextGen features USB-C and Ethernet LAN. The chargeable software application myChamber LIMS is available for connection to a LIMS, whilst the connectivity package for the myChamber Monitoring App is available for permanent remote monitoring. For electronic signatures according to 21 CFR Part 11, the basic licence FDAQ1 for AtmoCONTROL FDA and myChamber Control FDA can be added. None of the three options is included as standard.
Operation and connected load specifications
The ICO240 NextGen is rated for 230 V, 50/60 Hz; Option X2 converts it to 115 V at no extra cost; power consumption is approximately 1,750 W, the highest figure in the series. The textured stainless steel housing measures 748 x 1013 x 689 mm (width x height x depth), plus a 50 mm allowance for the door handle; the internal dimensions are 600 x 810 x 500 mm. The net weight is 113 kg; when packed, it weighs 132 kg; delivery and installation should be planned accordingly.
Other sizes in the ICO NextGen series
In addition to the ICO240 (243 litres), we offer the ICO50 (56 litres) and the ICO105 (108 litres) for smaller applications, as well as the ICO180 (177 litres, successor to the previous ICO150), each featuring the same operating concept and the same control parameters.
Typical applications
With the largest internal volume in the range, as well as controlled temperature and CO₂ concentration, the ICO240 NextGen is suitable for:
High sample throughput or multiple parallel test series in a single unit
Microbiological, pharmaceutical and biotechnological research requiring a large amount of space
Laboratory operations with multiple users who can access specific areas via the optional glass doors (Option K4, 3 doors)
Laboratory operations involving frequently changing culture batches, thanks to the integrated sterilisation function
Technical details
Internal volume243 litres
Internal dimensions (W x H x D)600 x 810 x 500 mm (depth minus 37.5 mm for the fan)
Cabinet dimensions (W x H x D)748 x 1013 x 689 mm (plus 50 mm door handle)
Interior materialStainless steel grade 1.4301 (ASTM 304), deep-drawn
Temperature setting range+20 to +50 °C
Operating temperature rangeat least 5 °C above room temperature up to +50 °C
Temperature accuracy0.1 °C (temporal variation at 37 °C ±0.1 K, spatial ±0.3 K)
CO₂ control0 to 20 % CO₂, accuracy 0.1 %, temporal variation ±0.2 % CO₂
Humidity control (Option K7)40 to 98 % rh and rh-Off, accuracy 0.1 % rh
O₂ control (Option T6, requires K7)1 to 20 % O₂, accuracy 0.1 %
Control unit6.86" IPS touchscreen (480 x 1280 pixels), multi-touch
DoorFully insulated stainless steel door, 2-point locking, internal glass door (optional: 3 doors with glass cut-outs, Option K4)
Shelves2x stainless steel perforated shelves included in the scope of delivery, up to 9 possible
Max. load135 kg total / 15 kg per shelf
Installation4 adjustable feet
InterfacesUSB-C, Ethernet LAN
Factory calibration certificate+37 °C, 5 % CO₂ (standard; with option K7 additionally 90 % rh, with K7 and T6 additionally 10 % O₂)
Voltage/Power230 V, 50/60 Hz, approx. 1,750 W (Option X2: 115 V at no extra charge)
Net weight/Gross weight113 kg / 132 kg
Scope of delivery
1x Memmert ICO240 NextGen CO₂ incubator (basic unit)
2x stainless steel perforated shelves
1x stainless steel water tray
1x CO₂ connection set (hose with connector and hose clamp)
1x factory calibration certificate (+37 °C, 5 % CO₂)
Not included in the scope of delivery: active humidity control (Option K7), O₂ control (Option T6), glass doors (Option K4), battery storage (Option C2), stacking kits and the water canister with connection hose (only when option K7 is ordered) are additional options, as are the software licences for myChamber LIMS, the Monitoring App and FDAQ1.
Regulatory information
Manufacturer’s WEEE registration number (Memmert GmbH + Co. KG, Stiftung EAR): DE 66812464. The ICO240 NextGen is not a medical device. Memmert is discontinuing the separate, previous ICOmed medical device series (last order 6 November 2026); according to Memmert, the ICO NextGen is currently undergoing testing and qualification to also meet the requirements for medical applications; this is an announcement, not an approval that has already been granted.
Individual requirements and procurement service
Memmert units bought from us are covered for three years from delivery: the first 12 months are followed by a 24-month warranty under Memmert’s terms, handled through us. Your statutory rights remain unaffected. Our procurement service can assist you with additional stainless steel perforated shelves (options K7, T6, K4 or C2), a stacking set for placing two ICO240 units on top of one another, or a bespoke calibration. As factory options, Memmert also offers DAkkS calibration according to DKD-R 5-7, IQ/OQ documents and IQ/OQ qualification. We order these with the device on request.