Memmert SF450plus Hot-Air Steriliser, 449 L, TwinDISPLAY – Class IIb medical device
€5,480.00
Available, delivery time: 3 – 5 Wochen
- Class IIb medical device (449-litre capacity).
- TwinDISPLAY & 2x Pt100 sensors (redundancy).
- HeatBALANCE: Adjustable top/bottom heat distribution.
- Mobile on lockable castors (standard).
- Forced convection (adjustable) for uniformity.
- Validatable sterilisation thanks to SetpointWAIT.
- MPN: SF450plus
Product information "Memmert SF450plus Hot-Air Steriliser, 449 L, TwinDISPLAY – Class IIb medical device"
The Memmert SF450plus hot-air steriliser is a Class IIb medical device (in accordance with MDD 93/42/EEC, transitional provisions until 31 December 2028 pursuant to (EU) 2023/607) designed for the sterilisation of medical materials using dry heat at atmospheric pressure. With an internal chamber volume of 449 litres and a temperature setting range of +20 to +250 °C, the unit is suitable for large batches and high throughput in central sterilisation departments, hospitals and industrial applications.
Precise temperature control with SetpointWAIT and HeatBALANCE
Two Pt100 sensors measure the temperature redundantly using the 4-wire measurement method (DIN Class A) with an accuracy of ±0.1 °C up to 99.9 °C and ±0.5 °C from 100 °C onwards: if one sensor fails, the second takes over automatically – ensuring additional process reliability. The SetpointWAIT function only starts the sterilisation time once the setpoint temperature has actually been reached. By adjusting the heat output distribution between the upper and lower heating groups from -50% to +50%, the heat output distribution between the upper and lower heating groups can be adjusted by -50% to +50% to adapt the heat distribution to different loads. The air turbine is electronically controlled, adjustable in 10% increments, low-noise and segment-specific; in addition, electronically controlled fresh air and exhaust air dampers ensure controlled air exchange.
Robust construction and enhanced safety
The interior is made of stainless steel with deep-drawn ribbing and is heated on all four sides; the fully insulated stainless steel door locks via a two-point compression latch. For safety, a mechanical temperature limiter (DIN 12880 Class 1) monitors the unit, triggering at around 20 °C above the maximum temperature – this can also be selected as a temperature selector monitor (Protection Class 3.1) or a temperature selector limiter (Protection Class 2) directly on the display. The additional AutoSAFETY function automatically monitors over- and under-temperature conditions at a freely selectable margin from the setpoint and triggers a visual and audible alarm in the event of a deviation. An integrated self-diagnostic system automatically detects faults. The housing is mounted on castors that can be moved and locked in place, allowing for flexible use even with larger units.
Operation, interfaces and documentation
The SF450plus is controlled via the ControlCOCKPIT TwinDISPLAY: an adaptive digital PID microprocessor controller with two high-resolution TFT colour graphic displays and a digital timer (1 min to 99 days). Programmes can be programmed, managed and transferred via the Ethernet interface or via USB using the AtmoCONTROL software – the programme sequence remains stored even after a power cut. This significantly simplifies documentation for quality management.
Typical applications
As a Class IIb medical device, the SF450plus is designed for the sterilisation of medical materials using dry heat at atmospheric pressure – typical applications include:
- Sterilisation of surgical instruments in clinics and hospitals
- Reprocessing of instruments in doctors’ and dentists’ surgeries
- Sterilisation of laboratory glassware and accessories in microbiological and pharmaceutical laboratories
- Practice and hospital hygiene with documented, validatable processes
Technical details
| Internal volume | 449 litres |
| Internal dimensions (W×H×D) | 1040 × 720 × 600 mm |
| External dimensions (W×H×D) | 1224 × 1247 × 784 mm (+56 mm depth for door handle) |
| Temperature range | +20 to +250 °C |
| Temperature accuracy | ±0.1 °C (up to 99.9 °C) / ±0.5 °C (from 100 °C) |
| Sensors | 2 Pt100 sensors, DIN Class A, in a 4-wire configuration for mutual monitoring and automatic failover in the event of a fault |
| Ventilation | Electronically controlled, adjustable in 10 % increments, low-noise, segment-specific |
| Fresh air/exhaust air | Addition of preheated fresh air via an electronically adjustable exhaust air damper; exhaust air connection with throttle valve, electronically controllable |
| Control | ControlCOCKPIT TwinDISPLAY, 2 TFT colour graphic displays, digital PID microprocessor controller |
| Timer | Digital countdown timer with target time display, adjustable from 1 min to 99 days |
| Safety function | SetpointWAIT (start only once the setpoint temperature has been reached) + HeatBALANCE (heat distribution -50% to +50%) |
| Temperature monitoring | Mechanical temperature limiter (DIN 12880 Class 1) + selectable temperature monitor/limiter + AutoSAFETY (over/under-temperature monitoring, visual/audible alarm) |
| Interior material | Stainless steel with deep-drawn ribbing, 4-sided circulation heating |
| Door | Fully insulated stainless steel doors with 2-point locking (compression door seal), lockable |
| Rear panel | Galvanised sheet steel |
| Installation | Can be moved and locked in place, on castors |
| Max. load | 300 kg total / 30 kg per drawer |
| Max. number of shelves | 8 |
| Interfaces | Ethernet, USB (with AtmoCONTROL software) |
| Voltage/Power | 400 V and 3 x 230 V neutral, 50/60 Hz approx. 5800 W |
| Installation requirements | The distance between the wall and the rear of the unit must be at least 15 cm. The distance to the ceiling must not be less than 20 cm, and the lateral distance to the wall or to an adjacent unit must not be less than 5 cm. Max. 2,000 m above sea level. |
| Ambient conditions | +5 ºC to +40 ºC, max. 80 per cent non-condensing |
| Packaging dimensions | 1330 x 1440 x 1050 mm |
| Net weight/Gross weight | approx. 161 kg / approx. 227 kg |
| Certifications | CE (LGA, 0197), VDE, UL |
| Medical device classification | Class IIb in accordance with MDD 93/42/EEC |
Scope of delivery
- 1x Memmert SF450plus hot-air steriliser (basic unit)
- 2 stainless steel wire racks, electropolished
- 1x factory calibration certificate (calibrated at +160°C)
Regulatory information
Manufacturer’s WEEE registration number (Memmert GmbH + Co. KG, Stiftung EAR): DE 66812464.
Customised requirements & procurement service
Do you require additional accessories such as further stainless steel grating panels, a USB stick with AtmoCONTROL software or a bespoke calibration? Our procurement service will be happy to assist you with special requests and spare parts.
| Volume: | 449 l |
|---|