Memmert SF750 Hot-Air Steriliser, 749 L, Class IIb medical device

Product information "Memmert SF750 Hot-Air Steriliser, 749 L, Class IIb medical device"

The Memmert SF750 hot-air steriliser is a Class IIb medical device (in accordance with MDD 93/42/EEC, transitional provisions until 31 December 2028 pursuant to (EU) 2023/607) designed for the sterilisation of medical materials using dry heat at atmospheric pressure. With an internal chamber volume of 749 litres and a temperature setting range of +20 to +250 °C, the unit is suitable for large batches and high throughput in central sterilisation departments, hospitals and industrial applications.

Precise temperature control with SetpointWAIT

A 1 Pt100 DIN Class A sensor in a 4-wire configuration measures the temperature with an accuracy of ±0.1 °C up to 99.9 °C and ±0.5 °C from 100 °C onwards. The SetpointWAIT function only starts the sterilisation time once the setpoint temperature has actually been reached – ensuring validatable, reproducible cycles. The air turbine is electronically controlled, adjustable in 10 per cent increments and low-noise; in addition, electronically controlled fresh air and exhaust air dampers ensure controlled air exchange.

Robust construction and safety

The interior is made of stainless steel with deep-drawn ribbing and is heated on all four sides; the fully insulated stainless steel door locks via a 2-point compression lock. For safety, the unit monitors the temperature electronically and additionally via a mechanical temperature limiter (DIN 12880 Class 1), which triggers at around 20 °C above the maximum temperature. An integrated self-diagnostic system automatically detects faults. The housing is mounted on castors that can be moved and locked in place, allowing for flexible use even with larger units.

Operation, interfaces and documentation

The SF750 is controlled via the ControlCOCKPIT SingleDISPLAY: an adaptive digital PID microprocessor controller with a high-resolution TFT colour graphic display and a digital timer (1 min to 99 days). Log data can be read, managed and organised via the Ethernet interface (a time-limited trial version is available for download); a USB stick containing the AtmoCONTROL software is available as an accessory on request. The programme sequence remains stored even after a power cut – this significantly simplifies documentation for quality management.

Typical applications

As a Class IIb medical device, the SF750 is designed for the sterilisation of medical materials using dry heat at atmospheric pressure – typical applications include:

  • Sterilisation of surgical instruments in clinics and hospitals
  • Reprocessing of instruments in doctors’ and dentists’ surgeries
  • Sterilisation of laboratory glassware and accessories in microbiological and pharmaceutical laboratories
  • Practice and hospital hygiene with documented, validatable processes

Technical details

Internal volume749 litres
Internal dimensions (W×H×D)1040 × 1200 × 600 mm
External dimensions (W×H×D)1224 × 1720 × 784 mm (+56 mm depth for door handle)
Temperature range+20 to +250 °C
Temperature accuracy±0.1 °C (up to 99.9 °C) / ±0.5 °C (from 100 °C)
Sensors1 Pt100 DIN Class A in 4-wire configuration
Ventilationelectronically controlled, adjustable in 10 % increments, low-noise
Fresh air/exhaust airPre-heated fresh air is introduced via an electronically adjustable exhaust air damper; exhaust air outlet with throttle valve, electronically controlled
ControlControlCOCKPIT SingleDISPLAY, TFT colour graphic display, digital PID microprocessor controller
TimerDigital countdown timer with target time display, adjustable from 1 minute to 99 days
Safety functionSetpointWAIT (start only once the setpoint temperature has been reached)
Temperature monitoringElectronic + mechanical temperature limiter (DIN 12880 Class 1), approx. 20 °C above maximum temperature
Interior materialStainless steel with deep-drawn ribbing, 4-sided circulation heating
DoorFully insulated stainless steel doors with 2-point locking (compression door seal), lockable
Rear panelGalvanised sheet steel
InstallationCan be moved and locked in place, on castors
Max. load300 kg total / 30 kg per drawer
Max. number of shelves14
InterfacesEthernet, USB (with AtmoCONTROL software)
Voltage/Power400 V and 3 x 230 V neutral, 50/60 Hz approx. 7000 W
Installation requirementsThe distance between the wall and the rear of the unit must be at least 15 cm. The distance to the ceiling must not be less than 20 cm, and the lateral distance to the wall or to an adjacent unit must not be less than 5 cm. Max. 2,000 m above sea level.
Ambient conditions+5 ºC to +40 ºC, max. 80 per cent non-condensing
Packaging dimensions1330 x 1910 x 1050 mm
Net weight/Gross weightapprox. 217 kg / approx. 288 kg
CertificationsCE (LGA, 0197), VDE, UL
Medical device classificationClass IIb in accordance with MDD 93/42/EEC

Scope of delivery

  • 1x Memmert SF750 hot-air steriliser (basic unit)
  • 2 stainless steel wire racks, electropolished
  • 1x factory calibration certificate (calibrated at +160°C)

Regulatory information

Manufacturer’s WEEE registration number (Memmert GmbH + Co. KG, Stiftung EAR): DE 66812464.

Customised requirements & procurement service

Do you require additional accessories such as further stainless steel grating panels, a USB stick with AtmoCONTROL software or a bespoke calibration? Our procurement service will be happy to assist you with special requests and spare parts.

Volume: 749 l