Memmert SN160plus Hot-Air Steriliser, 161 L, Natural Convection, TwinDISPLAY – Class IIb medical device
€3,039.00
Available, delivery time: 3 – 5 Wochen
- Class IIb medical device (natural convection).
- TwinDISPLAY & 2x Pt100 sensors (redundancy).
- 161-litre capacity for turbulence-free sterilisation.
- HeatBALANCE: Adjustable top/bottom heat distribution.
- Process reliability thanks to SetpointWAIT.
- Hygienic stainless steel interior.
- MPN: SN160plus
Product information "Memmert SN160plus Hot-Air Steriliser, 161 L, Natural Convection, TwinDISPLAY – Class IIb medical device"
The Memmert SN160plus hot-air steriliser sterilises medical materials using dry heat at atmospheric pressure – as a Class IIb medical device (in accordance with MDD 93/42/EEC), it is suitable for hospital laboratories, microbiological and pharmaceutical laboratories, as well as larger medical practices with regular sterilisation requirements. With an internal capacity of 161 litres and a temperature range of +20 °C to +250 °C, the unit is particularly suitable for the reliable sterilisation of multiple batches of instruments, vessels or powders during day-to-day practice or laboratory operations. The combination of certified medical device classification and a validatable sterilisation process supports the traceability and documentation requirements that are standard in the quality management systems of medical practices, hospitals and laboratories.
Natural convection instead of forced air circulation
Unlike the Memmert SF series, the SN160plus operates using natural ventilation rather than an electronically controlled recirculation fan. Preheated fresh air is introduced via an electronically adjustable exhaust air damper, whilst an exhaust air outlet with an adjustable throttle valve ensures controlled air exchange – entirely without any active air movement inside the chamber. This makes the SN series the preferred choice wherever powders, granules or light, exposed instruments could be stirred up or contaminated by a forced air flow.
Precise temperature control with SetpointWAIT
The TwinDISPLAY version, the SN160plus, provides additional safeguards for this process: two independent Pt100 sensors using a 4-wire measurement method monitor the temperature in a redundant configuration – if one sensor fails, the second seamlessly takes over control. The SetpointWAIT function only starts the sterilisation time once the setpoint temperature has actually been reached – ensuring validatable, reproducible cycles, as required for quality management documentation in dental and clinical hygiene, as well as in microbiological and pharmaceutical laboratories.
Safety and Features
- Electronic temperature monitoring plus mechanical temperature limiter, protection class 1 (DIN 12880)
- Self-diagnostic system for fault detection, visual and audible alarms
- AutoSAFETY: additional integrated over- and under-temperature monitoring
- HeatBALANCE: heating power distribution individually adjustable from -50% to +50%
- Controller: TwinDISPLAY, adaptive multifunctional digital PID microprocessor controller with high-resolution TFT colour graphic display
- Digital countdown timer with target time setting, adjustable from 1 minute to 99 days
Operation, interfaces and documentation
Programmes can be managed and logger data read out and archived via the Ethernet interface or, optionally, via a USB stick using the AtmoCONTROL software – the programme sequence remains stored even after a power cut. This significantly facilitates comprehensive documentation in quality management, a criterion that is particularly important for validatable sterilisation processes in hospitals and laboratories. The built-in self-diagnostic system reports faults at an early stage via visual and audible alarms, so that deviations from the target process are not only noticed at the end of a sterilisation cycle, but can be detected and documented immediately.
Typical areas of application
- Sterilisation of instruments in medical practices and hospital hygiene
- Sterilisation of powders, granules and bulk materials without air movement inside the chamber
- Reprocessing of laboratory glassware and open vessels in microbiological and pharmaceutical laboratories
- Validatable, documented sterilisation cycles in quality management
This allows a large batch of instruments or vessels to be sterilised reliably and with full traceability in a single operation whilst the hospital or laboratory is in operation, without sensitive items being displaced by air flow.
Technical details
| Internal chamber volume | 161 litres |
| Internal dimensions (W×H×D) | 560 x 720 x 400 mm |
| External dimensions (W×H×D) | 745 x 1104 x 584 mm (+56 mm depth for door handle) |
| Temperature range | +20 °C to +250 °C |
| Temperature accuracy | ±0.1 °C (up to 99.9 °C) / ±0.5 °C (from 100 °C) |
| Sensors | 2 Pt100 sensors, DIN Class A, in a 4-wire configuration (cross-monitoring) |
| Convection | Natural ventilation (no circulation fan) |
| Fresh air/exhaust air | Electronically adjustable exhaust air damper, exhaust air outlet with adjustable throttle valve |
| Control | TwinDISPLAY, digital PID microprocessor controller, TFT colour graphic display |
| Timer | Digital, 1 minute to 99 days |
| Safety function | SetpointWAIT (start only once the setpoint temperature has been reached) |
| Temperature monitoring | Electronic + mechanical temperature limiter (DIN 12880 Class 1) |
| Max. load | 210 kg total / 20 kg per shelf |
| Max. number of shelves | 8 |
| Interfaces | Ethernet, USB (with AtmoCONTROL software) |
| Voltage/Power | 230 V/50/60 Hz at approx. 3200 W or 115 V/50/60 Hz at approx. 1800 W |
| Installation requirements | Min. 15 cm clearance from the rear wall, 20 cm clearance from the ceiling, 5 cm clearance at the sides; max. installation height 2,000 m |
| Environmental conditions | +5 °C to +40 °C, max. 80% relative humidity (non-condensing) |
| Packaging dimensions | 830 x 1,300 x 800 mm |
| Net weight/Gross weight | approx. 96 kg / approx. 122 kg |
| Certifications | CE (LGA, 0197), VDE, UL |
| Medical device classification | Class IIb in accordance with MDD 93/42/EEC |
Scope of delivery
- 1x Memmert SN160plus hot-air steriliser (basic unit)
- 2x stainless steel wire racks (electropolished)
- 1x factory calibration certificate (at +160 °C)
Regulatory information
WEEE registration number (manufacturer Memmert): DE 66812464. As an electrical appliance, the SN160plus falls under the ElektroG (WEEE Directive) – registration is held by the manufacturer Memmert, as they are the first to place the appliance on the German market, not by LT Laborhandel as the distribution partner.
Customised requirements & procurement service
Do you require additional accessories such as further stainless steel grids, a bespoke calibration or spare parts? Our procurement service will be happy to assist you with any special enquiries regarding the SN160plus.
| Volume: | 161 l |
|---|