Skip to main content Skip to search Skip to main navigation

Memmert stacking kit B42114 for HCP150 humidity chamber

ⓘ  This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.

Product information "Memmert stacking kit B42114 for HCP150 humidity chamber"

The B42114 stacking kit is intended for two units of the same size and consists of stacking corners, a connecting plate for the rear and two wall brackets. It is suitable for the HCP150 humidity chamber. For this size, the base frame B33508 can only be used for stacked units together with this stacking kit.

Suitable for

ModelSize
HCP150150

Scope of delivery

  • 1 stacking kit (stacking corners, connecting plate for the rear, 2 wall brackets)
Skip product gallery

Fits

Memmert Humidity Chamber HCP150, 156 l, +18 to +90 °C, 20 to 95 % rh
Memmert Humidity Chamber HCP150, 156 l, +18 to +90 °C, 20 to 95 % rh
Manufacturer number: HCP150

Ten shelves in 156 litres: the Memmert Humidity Chamber HCP150 is the third of four sizes in the HCP series and, with 700 mm internal height, considerably taller than the HCP105 with 480 mm at the same internal area of 560 x 400 mm. Externally it measures 719 x 1,070 x 591 mm plus 56 mm door handle. Temperature (+18 to +90 °C) and relative humidity (20 to 95 % rh, also rh-Off) are controlled by the ControlCOCKPIT TwinDISPLAY.Ten levels, 120 kg total loadAs standard, two stainless steel perforated trays are in the interior made of stainless steel 1.4301 (ASTM 304), and a maximum of ten shelves fit in. 15 kg apply per shelf, and 120 kg for the whole unit. The net weight is approx. 90 kg, and the connected load at 230 V approx. 1,800 W. The permanently installed parts include a heated inner glass door behind the fully insulated stainless steel door (2-point locking) and a humidity-tight silicone feedthrough with 40 mm inner diameter in the rear wall, centre left.Humidity from the canisterA water canister with connection hose is part of the scope of delivery. A self-priming pump supplies the water, the germ barrier works with hot steam generation, and dehumidification runs via a sterile filter. Only demineralised or fully deionised water comes into question, with 5 to 10 µS/cm conductivity and a pH value of 5 to 7. For alternatives for the water supply, such as a connection to the domestic water supply, we advise on request. Humidity can be set to an accuracy of 0.5 % rh, and temperature to 0.1 °C. Against condensate, heating on six sides, door heating and rear wall heating are at work.Control and data retentionThe TwinDISPLAY forms the ControlCOCKPIT: an adaptive, digital PID microprocessor controller with two high-resolution TFT colour graphic displays. Programs are created with the AtmoCONTROL software and reach the chamber via Ethernet or USB. The countdown clock covers 1 minute to 99 days, and SetpointWAIT waits for the setpoint temperature before starting the process time. Three values each for temperature and humidity are available for calibration. In the event of a power failure, the program sequence is saved. The menu languages range from German through Polish and Hungarian to Chinese.Protective functionsTwo Pt100 sensors (DIN class A, 4-wire measurement) monitor each other and step in for one another in the event of a fault. AutoSAFETY switches the heating off when the freely selectable interval to the setpoint is exceeded and alarms visually and acoustically when exceeded or fallen below. The self-diagnosis system concerns the temperature and humidity control. The permissible environment is 10 to 30 °C at a maximum of 70 % rel. humidity (non-condensing) and an altitude up to 2,000 m above sea level. The chamber is transported upright. It needs 15 cm to the wall at the back, 20 cm to the ceiling and 5 cm at the sides.Between HCP105 and HCP240The HCP105 has the same internal area, but only six shelves and 90 kg total load. The HCP240 (241 l, twelve shelves, 140 kg) is 600 mm wide and 500 mm deep inside. Anyone looking for a larger volume in a climate chamber with a different range will find 256 l at -10 to +60 °C and 10 to 80 % rh in the ICH260. The HCP150, by contrast, covers +18 to +90 °C and 20 to 95 % rh.Typical applicationsApplications of the HCP series include:Environmental testingEnvironmental simulationsAccelerated lifetime tests85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78Technical detailsInterior volume156 lInternal dimensions (W x H x D)560 x 700 x 400 mm (D less 35 mm for fan)External dimensions (W x H x D)719 x 1,070 x 591 mm (D plus 56 mm door handle)Net weightapprox. 90 kgShelves10 maximum, 2 perforated trays as standardPermissible load120 kg unit, 15 kg per shelfTemperature, setting range+18 to +90 °CTemperature, working range7 °C above room temperature to +90 °CTemperature, setting accuracy0.1 °CHumidity, setting range20 to 95 % rh and rh-OffHumidity, setting accuracy0.5 % rhSensors2x Pt100, DIN class A, 4-wire measurementDisplay and controllerTwinDISPLAY, adaptive PID microprocessor controller, 2x TFTWater quality5 to 10 µS/cm, pH 5 to 7, demineralised or fully deionisedMains connection 230 V50/60 Hz, approx. 1,800 WInterfacesEthernet LAN and USBInstallation conditions10 to 30 °C, max. 70 % rel. (non-condensing), up to 2,000 m above sea levelMarkingsCE, VDE GS, cMETusOther sizes in the seriesAll four sizes of the HCP series share the temperature and humidity range and differ in volume:ModelInternal volumeSetting temperatureHumidity rangeHCP5056 l+18 to +90 °C20 to 95 % rhHCP105107 l+18 to +90 °C20 to 95 % rhHCP150 (this page)156 l+18 to +90 °C20 to 95 % rhHCP240241 l+18 to +90 °C20 to 95 % rhScope of deliveryMemmert Humidity Chamber HCP150 (basic unit)2 stainless steel perforated traysFactory calibration certificate (measuring room centre of usable space), 60 °C at 75 % rhAdditional heated glass door insideFully insulated stainless steel door with 2-point locking (compression door lock)Humidity-tight silicone feedthrough, inner diameter 40 mm, rear wall, centre leftWater canister including connection hoseRegulatory informationThe unit is an electrical device within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer Memmert GmbH + Co. KG is DE 66812464. Notes on returning old appliances can be found on our page Environment and disposal.Individual requirements and procurement serviceFor the HCP150 there are factory options, specified when ordering, and suitable accessories. Which variants are available for your application, we clarify with Memmert on request. The same applies to calibrations and qualification documents. Write to us with what the chamber is to achieve. We will prepare a quotation with the suitable equipment. As factory options, Memmert also offers DAkkS calibration according to DKD-R 5-7, IQ/OQ documents and IQ/OQ qualification. We order these with the device on request.

Manufacturer's RRP: €9,706.00