Skip to main content Skip to search Skip to main navigation

Restek Rtx-1301 GC Capillary Column, 30 m, 0.53 mm ID, 3.00 µm, 16085

Product information "Restek Rtx-1301 GC Capillary Column, 30 m, 0.53 mm ID, 3.00 µm, 16085"

The Rtx-1301 is a capillary column with a low to medium polarity phase and intermediate polarity. This version is 30 m long, with an inner diameter of 0.53 mm and a film thickness of 3.00 µm, and the support tube is made of fused silica. With 0.53 mm ID it is a wide-bore column.

Phase, bleed and detectors

The phase carries the USP designation G43. Column bleed is low, even with sensitive detectors such as ECD and MSD. For some sizes the phase is also available as Integra-Guard columns with a built-in guard column.

Other columns for solvent analysis

Residual solvents are also on the application list of the Rxi-5ms, and solvent impurities on that of the Rxi-1ms. Both have 0.25 mm inner diameter and a considerably higher temperature range.

ColumnPhaseDimensions and temperature
Rtx-1301 (this page)low to medium polarity, intermediate polarity30 m, 0.53 mm ID, 3.00 µm, -20 to 240 °C
Rxi-5msDiphenyl dimethyl polysiloxane30 m, 0.25 mm ID, 0.25 µm, -60 to 330/350 °C
Rxi-1msDimethyl polysiloxane30 m, 0.25 mm ID, 0.25 µm, -60 to 330/350 °C

Mind the temperature limit

For this item, the temperature range -20 °C to 240 °C applies. The Rtx-1301 family has different maximum temperatures depending on the dimension. When transferring a method, therefore compare the final temperature of the method with 240 °C.

Equivalents at a glance

Anyone switching from another brand will find the phase under the following designations:

ManufacturerComparable phases
AgilentCP-Select 624 CB, DB-1301, DB-624, DB-624UI, DB-Select 624 UI
PhenomenexZB-624
Quadrex007-1301, 007-624, 007-502
Supelco/Millipore SigmaSPB-624

Dimensions

Length 30 m, inner diameter 0.53 mm and film thickness 3.00 µm are to be checked together with the phase when matching against columns from other manufacturers. Among the comparable phases above are several 624 types.

Typical applications

  • General-purpose column for alcohols
  • Beverages
  • Residual solvents
  • Volatile organic compounds

Volatile organic compounds (VOCs) are substances with a low boiling point, and residual solvents are solvent residues, for example from manufacturing processes. Alcohols are organic compounds with one or more hydroxyl groups.

On the detectors: ECD is the electron capture detector, MSD the mass selective detector.

Technical details

ManufacturerRestek
PhaseRtx-1301
Phase typeLow to medium polarity
PolarityIntermediate
USP phaseG43
Length30 m
Inner diameter0.53 mm
Film thickness3.00 µm
Column materialFused silica
Temperature range-20 °C to 240 °C
Packaging unit1 piece
UNSPSC41115710
Part number16085

Scope of delivery

One capillary column, single.

Guard columns, liners and further accessories are separate items.

Individual requirements and procurement service

Restek offers the Rtx-1301 in further dimensions. LT procures it on request, as well as other phases, liners and accessories, by Restek part number if desired. Quantity and delivery address help with the quote. Matching Restek liners and reference standards can be ordered in the same request. Anyone who needs several columns or accessories can combine everything in one request.