Product information "WTW Technical buffer solution TPL 4, pH 4.01, 250 ml, 108800"

At the acidic end of the pH scale, the technical buffer solution pH 4 provides the second fixed reference point for the calibration of pH electrodes. The WTW technical buffer solution pH 4.01 is used in conjunction with pH 7 and pH 10 for 2- or 3-point calibration, thereby covering the acidic measurement range, which plays a key role in many applications in industry, water analysis and research. It is available in three container sizes ranging from 50 ml to 1,000 ml, so that it can meet both occasional requirements in small laboratories and regular consumption where frequent calibration is required.

Potassium hydrogen phthalate as the buffer substance

Potassium hydrogen phthalate is used as the buffer system; it is one of the most common substances for acidic reference buffer solutions. At 20 °C, the pH value is 4.01, with an accuracy of ± 0.03 pH. This tolerance is narrow enough to achieve comparable, reproducible calibration results even when using multiple electrodes and measuring instruments in the laboratory, regardless of which team member carries out the calibration.

Why an acidic calibration point is important

Calibration in the neutral range alone says little about how precisely an electrode measures outside pH 7. If the actual sample deviates significantly from the neutral range, as is often the case with acidic process solutions, foodstuffs or environmental samples, a second calibration point at pH 4 ensures that the slope of the electrode is correctly recorded over a wider range. Combined with pH 7 and pH 10, this results in a complete 3-point calibration that delivers reliable measurement results even when sample values fluctuate significantly.

WTW, a brand of Xylem

The buffer solution is supplied by WTW, an established brand in pH measurement technology and electrochemistry, which is now part of Xylem. Many laboratories already rely on WTW measuring instruments and electrodes; the technical buffer solution is designed to complement these as a matched calibration solution. However, it can generally be used with any pH electrode and any pH meter, regardless of the manufacturer; the calibration is not tied to a specific measuring instrument.

Pack sizes of the technical buffer solution pH 4

Select the appropriate pack size above: STP 4 as a 50-ml bottle for economical use or as a supplement in an electrode case; TPL 4 with 250 ml for routine laboratory use; and TEP 4 with 1,000 ml for frequent calibration requirements or multiple measuring points.

ModelVolume
STP 450 ml
TPL 4250 ml
TEP 41,000 ml

Storage, shelf life and handling

At 20 °C, the buffer solution has a density of 1.01 g/cm³ and a melting point of -1.6 °C. Unopened, it has a shelf life of 3 years when stored at 15 to 25 °C. It is not classified under GHS/CLP and is not a dangerous good, which simplifies storage, handling and dispatch in everyday laboratory work without the need for additional dangerous goods labelling.

Avoiding contamination

To ensure that calibration remains reliable throughout the entire shelf life, buffer solution that has been removed should not be poured back into the bottle. Even small amounts of contamination from the measurement environment or from the electrode can alter the pH value of the remaining solution and distort subsequent calibrations; the phthalate buffer is particularly sensitive to foreign ions in the acidic range. For daily use, it is therefore advisable to use a small calibration vessel into which only as much buffer solution is poured as is required for the current calibration. The bottle itself should be kept tightly sealed and stored at a temperature between 15 and 25 °C to ensure that the documented accuracy of ± 0.03 pH is maintained until the end of the three-year shelf life.

Typical applications

The technical buffer solution pH 4 is used wherever pH electrodes need to measure reliably in the acidic range, not only for a one-off calibration but as an integral part of ongoing quality assurance:

  • Acidic calibration point in industrial process control, e.g. for cleaning and process solutions
  • Water analysis and environmental samples with low pH values
  • Food- and beverage-related laboratory applications involving acidic samples
  • Research and teaching, as a second reference point alongside pH 7 and pH 10
  • Commissioning and functional testing of new pH electrodes prior to first use

Technical details

Buffer systemPotassium hydrogen phthalate
pH value at 20 °C4.01
Accuracy± 0.03 pH
Density at 20 °C1.01 g/cm³
Melting point-1.6 °C
Shelf life when unopened3 years
Storage temperature15 to 25 °C
GHS/CLP classificationNot classified, not a dangerous good

Scope of delivery

  • 1 bottle of WTW technical buffer solution pH 4.01 in the selected container size (50 ml, 250 ml or 1,000 ml)

Individual requirements & procurement service

For complete 3-point calibration, there is also the same technical buffer solution with pH 7.00 and, in trace quality, with pH 10.01, as well as suitable pH electrodes. For larger quantities, custom container sizes or enquiries regarding the appropriate calibration solution, our procurement service will be happy to assist you.

Buffer type: Technical
Contents: 250 ml
pH value: 4