Larger beakers, several flasks side by side or batches above 10 litres need a work surface that also supports this load across its area, not just a powerful heater. For this, the IKA C-MAG HS 10 (0003581400) comes with a 260 x 260 millimetre ceramic plate, considerably larger than that of the C-MAG HS 7, combined with 1500 watts of heating power and a stirring capacity of up to 15 litres of water.

Large ceramic work surface for greater vessel variety

With 260 x 260 millimetres, the ceramic plate offers considerably more room than the 180 x 180 millimetre surface of the C-MAG HS 7, for example for wide crystallising dishes, large round-bottom flasks or several smaller vessels at the same time. The heating power of 1500 watts covers a temperature range of 50 to 500 degrees Celsius, set via a rotary knob with an accuracy of 5 kelvin and shown on an LED display. A fixed safety circuit limits the plate temperature to a maximum of 550 degrees Celsius regardless of the setpoint temperature.

Stirring up to 15 litres, load up to 20 kilograms

As with the C-MAG HS 7, the stirring drive covers a speed range of 100 to 1500 revolutions per minute, set via a six-step scale, and stirring bars up to 80 millimetres in length can be used. The higher permissible load of 20 kilograms makes it possible to place additional stand material, reflux condensers or double-jacketed reaction vessels on the plate alongside the stirred material without exhausting the limit values.

Expandable with external temperature measurement

Via the connection socket according to DIN 12878, an ETS-D5 contact thermometer can be retrofitted if required, in order to measure the temperature directly in the medium instead of only at the plate surface. The sensor itself is not part of the scope of delivery of the C-MAG HS 10 and must be procured separately if required.

Higher heating power for faster heating times

With 1500 instead of 1000 watts, the C-MAG HS 10 delivers more heating power than the C-MAG HS 7, distributed over a larger area, which reduces the time to reach the setpoint temperature at a comparable fill level. Especially with larger quantities of water or several vessels heated at the same time, the difference in power is noticeable in everyday laboratory work, without anything having to be changed in the operating logic compared with the smaller model.

Typical applications

With a large work surface and increased heating power, the C-MAG HS 10 is technically suited for:

  • Preparing and heating larger volumes up to 15 litres
  • Stirring or heating several smaller vessels on one plate at the same time
  • Batches with larger crystallising dishes or wide round-bottom flasks
  • Routine processes in which fast heating through higher heating power saves time
  • Laboratory workstations with changing vessel size without changing the base device

Selection guide within the C-MAG series

Within the C-MAG family, the HS 10 marks the largest work surface and highest heating power among the models with analogue operation:

ModelPlate sizeStirring capacity (H2O)Heating powerOperation
C-MAG HS 10 (this device)260 x 260 mm15 l1500 WAnalogue scale, LED setpoint temperature
C-MAG HS 7180 x 180 mm10 l1000 WAnalogue scale, LED setpoint temperature
C-MAG HS 7 control180 x 180 mm20 l1000 WLCD, PT1000/ETS-D5/ETS-D6, RS232, USB
C-MAG HP 7180 x 180 mm10 l (heating only)1000 WAnalogue scale, LED setpoint temperature

Anyone who needs documented temperature control in the medium or interfaces is better served by the C-MAG HS 7 control, even if its plate area is smaller. Anyone who, on the other hand, is mainly looking for space on the work surface and heating power, without needing digital functions, will find the largest area of the series in the HS 10.

Differences from the nearest C-MAG models

The IKA C-MAG HS 7 covers most standard batches up to 10 litres with the smaller 180 x 180 millimetre plate and 1000 watts of heating power and is the more compact alternative. The IKA C-MAG HS 7 control brings, with a smaller plate, a higher stirring capacity of 20 litres as well as a digital display and interfaces. Anyone who only needs to heat but not stir will find, with the IKA C-MAG HP 7 a pure heating plate in the same form factor as the HS 7.

Technical details

Number of stirring positions1
Max. stirring capacity (H2O)15 l
Maximum load20 kg
Motor power output1.5 W
Speed range100 to 1500 rpm, scale 0 to 6
Stirring bar length max.80 mm
Heating power1500 W
Heating temperature range50 to 500 °C, rotary knob, setting accuracy 5 K
Safety circuit fixed550 °C
Connection for external temperature sensorETS-D5 (DIN 12878)
Work surface materialCeramic
Work surface dimensions260 x 260 mm
Permissible relative humidity80 %
Dimensions (W x H x D)300 x 105 x 415 mm
Weight6 kg
Degree of protectionIP 21 (DIN EN 60529)
Mains connection230 V, 50/60 Hz, 1520 W (further voltage variants 120 V / 100 V available)

Scope of delivery

  • 1 x IKA C-MAG HS 10 magnetic stirrer with heating (0003581400)
  • 1 x IKAFLON 20 magnetic stirring bar
  • 1 x IKAFLON 30 magnetic stirring bar
  • 1 x IKAFLON 40 magnetic stirring bar

An external temperature sensor such as the ETS-D5 is not included in the scope of delivery.

Use, installation, maintenance and disposal

With degree of protection IP 21, the C-MAG HS 10 is protected against vertically falling drip water and designed for operation in the fume hood or on a stable, level laboratory bench at up to 80 percent relative humidity. Because of the larger work surface and higher heating power, sufficient distance to flammable materials, solvent bottles and adjacent devices should be planned when setting up, particularly with continuous operation with several vessels on the plate. The ceramic surface is chemical-resistant, but the device should cool down and be disconnected from the mains before cleaning. The fixed safety circuit at 550 degrees Celsius additionally protects against overheating. At the end of its service life, the device does not belong in household waste as electrical equipment but in separate waste electrical equipment collection; the manufacturer's WEEE registration number is DE 66784213.

Investment logic: when the larger work surface pays off

Anyone who regularly works with vessels that become tight on a 180 x 180 millimetre plate, or who wants to heat several smaller vessels at the same time, gains noticeable flexibility with the 260 x 260 millimetre plate of the HS 10, without having to place a second, smaller device next to it. For standard batches up to 10 litres, where vessel size is irrelevant, the more compact and somewhat cheaper C-MAG HS 7 is usually sufficient. If a documented temperature measured in the medium is also required, the investment should go into the control version with the smaller plate rather than into the pure area enlargement of the HS 10.

Individual requirements & procurement service

For the C-MAG HS 10, suitable original accessories such as the ETS-D5 contact thermometer, stand material, protective covers, oil bath attachments and further magnetic stirring bars are available on request. Through our procurement service we also support you with spare parts, calibrations and the compilation of several workstations with uniform accessories. Further information and contact options can be found at lt-laborhandel.com/service.

Frequently asked questions

How much larger is the work surface compared with the C-MAG HS 7?
The plate of the HS 10 measures 260 x 260 millimetres compared with 180 x 180 millimetres for the HS 7, so considerably larger vessels or several vessels fit on the surface at the same time.

Can the C-MAG HS 10 also be used for stirring only, without heating?
Yes, speed and heating temperature are set via two separate controls and work independently of each other.

What is the maximum load on the work surface?
20 kilograms, which includes additional stand material or accessories on the plate and is thus above the 15 kilograms of the smaller C-MAG HS 7.

Is external temperature measurement in the medium possible?
Via the connection socket according to DIN 12878, an ETS-D5 contact thermometer can be retrofitted, which, however, must be procured separately.

Which stirring bars are included in the scope of delivery?
Three IKAFLON magnetic stirring bars of 20, 30 and 40 millimetres, suitable for bar lengths up to 80 millimetres.

How is the C-MAG HS 10 disposed of properly?
As electrical equipment, it belongs at a waste electrical equipment collection point instead of in household waste, and the manufacturer's WEEE registration number is given in the section Use, installation, maintenance and disposal.

Skip product gallery

Matching accessories

Discount
IKA ETS-D5 electronic contact thermometer with touchscreen, –20 °C to +400 °C, 0025008371
IKA ETS-D5 electronic contact thermometer with touchscreen, –20 °C to +400 °C, 0025008371
Herstellernummer: 0025008371

The new IKA ETS-D5 electronic contact thermometer (MPN 0025008371) completely redefines precision, safety and ease of use in laboratory thermal analysis. Developed as a high-performance mechatronic control unit for demanding laboratory processes, this instrument takes over active, direct temperature control of the medium once connected. It controls the heating power of a coupled magnetic stirrer by intelligently switching the heating plate on and off, whilst the stirrer itself acts as a redundant monitoring unit for the preset safety limits. The ETS-D5 thus transforms any compatible workstation into a future-proof, high-precision control centre for reproducible experimental series. Integrated safety architecture for risk-free processes From a process engineering perspective, the ETS-D5 offers a comprehensive range of sophisticated protective functions that contribute significantly to laboratory safety and risk minimisation. The system features an adjustable sensor timeout, which is triggered immediately if the probe is inadvertently outside the liquid medium. Precise temperature drop detection reacts dynamically to unexpected thermal gradients, whilst setpoint monitoring (Delta T) immediately stops temperature control if the target value is exceeded by a critical margin. To prevent operator errors in multi-user operation, the maximum settable temperature can be strictly limited via a setpoint limit. In the event of a transient fault, the heating circuit remains permanently switched off to protect personnel and the sample matrix. Optimised PID control and application-specific modes The instrument’s control technology ensures absolutely stable temperature control without thermal overshoot. Coupled with a high-precision, interchangeable PT1000 temperature sensor of tolerance class A, the system covers a wide operating range from –20 °C to +400 °C. Three application-specific temperature control modes ensure maximum flexibility in day-to-day laboratory work: ‘Fast’ for ultra-fast heating cycles, ‘Precise’ for working at the minimum tolerance limit, and a specialised synthesis block mode that is perfectly tailored to the thermodynamic requirements of chemical syntheses. For highly sensitive organic or biological sample structures, the heating rate can also be precisely reduced in percentage increments. Ergonomic touch-screen control concept and documentation The instrument’s exterior breaks away from complicated analogue designs and features a user-friendly, clear touchscreen display for intuitive parameter configuration during continuous operation. The almost completely enclosed system reliably protects the internal electronic components from aggressive vapours and liquids in the harsh everyday laboratory environment. A future-proof, integrated USB-C interface also enables the rapid, error-free export of all transient measurement data to a PC, thereby ensuring seamless documentation, validation and traceability of your processes in accordance with modern GLP standards. Technical details Measurement system & control characteristics Sensor type: PT1000 (DIN IEC 751 Class A), easily replaceable Temperature measurement range: –20 °C to +400 °C Measurement and setpoint resolution: 0.1 K Temperature measurement accuracy: ±0.2 K + tolerance of the PT1000 sensor Control accuracy in the medium: ±0.5 K (validated with 500 ml of water in a 600-ml beaker) Temperature control modes: Fast, Precise (highest accuracy), Synthesis block-optimised Heating rate: Individually adjustable in percentage steps for sensitive samples Control algorithm: Optimised PID control to prevent overshoot Safety & monitoring functions Sensor timeout: Detects the absence of the sensor in the medium (time-adjustable) Temperature drop detection: Automatic response to unexpected temperature drops Setpoint monitoring (Delta T): Shuts off the heating function if the Delta T limit is exceeded Setpoint Limitation: Software-based limitation of the maximum settable temperature Safe-Temp & Emergency Protection: Immediate safety shutdown of the heating circuit in the event of a fault; the stirrer remains deactivated Operation, Interfaces & Geometry Display technology: User-friendly, flat touchscreen for intuitive operation Digital interface: USB-C for direct data transfer and software connection to a PC Connector to the main unit: DIN 45322 (MAS6 standard) Dimensions (width x height x depth): 52 x 36 x 385 mm Minimum probe insertion depth: 20 mm Net weight: 0.156 kg (156 grams) Environmental data & electrical specifications Protection class according to DIN EN 60529: IP 54 (dust- and splash-proof) Operating voltage / DC voltage: 8 to 16 V= Current consumption: 100 mA Permissible ambient temperature: +5 to +40 degrees Celsius Permissible relative humidity: Up to 80 per cent Contents of the package 1 x IKA ETS-D5 electronic contact thermometer (MPN: 0025008371) 1 x PT1000 temperature probe (standard version) 1 x USB-C connection cable 1 x Detailed operating instructions / safety guide Individual Requirements & Accessories To ensure optimal utilisation of the intelligent ETS-D5 control centre, we offer a complementary range of original system peripherals: Specialised probes for corrosive media: Optional interchangeable sensors made from robust special-purpose glass (H66.51) or featuring a highly chemically resistant protective coating (H66.53) for safe operation in acids and alkalis. Mechanical mounts: Precisely fitting extension cables for flexible spatial extension of the measuring station, as well as sturdy IKA support rods and cross-couplings for vibration-free stand locking above the sample point. Compatible stirring systems: Ideal as a metrological upgrade for IKA magnetic stirrers without integrated primary temperature control, to establish a redundant, independent medium safety circuit. Use our technical B2B procurement service to configure your measuring stations.

Sale price: €295.80 Manufacturer's RRP: €348.00 15% below manufacturer's RRP