Not every workstation needs a stirrer as well, for example when stirring is done externally and a water bath is only to be temperature-controlled or a vessel is only to be heated. The IKA C-MAG HP 7 (0003581800) is a hotplate without magnetic stirring function, with 1000 watts of heating power, a ceramic surface measuring 180 x 180 millimetres and a heating temperature range of 50 to 500 degrees Celsius. It is technically derived from the proven C-MAG HS series, but without the stirring drive.

1000 watts of heating power without stirring function

The ceramic plate transfers the heating power directly to the vessel placed on it and covers a temperature range of 50 to 500 degrees Celsius, set with a rotary knob with an accuracy of 5 Kelvin. According to the data sheet, the heating rate is 5 Kelvin per minute, a guide value for estimating how quickly a given volume of water reaches the set temperature. As no stirring drive is fitted, the otherwise usual speed scale is omitted and operation is limited to setting the temperature. According to the manufacturer, a volume of up to 10 litres of water can be heated with it.

Can be extended with external temperature measurement in the medium

Via the connection socket according to DIN 12878, an ETS-D5 contact thermometer can be retrofitted to measure the temperature directly in the medium instead of only at the plate surface, which is practical for oil baths, for example, or when an externally driven stirrer is already part of the setup. The sensor itself is not included in the scope of delivery.

Compact design for integration into existing setups

With dimensions of 220 x 105 x 330 millimetres and a weight of 4.4 kilograms, the HP 7 can be integrated into existing experimental setups without taking up much space, for example underneath a stand with a separate stirrer or as a plain heat source for an oil bath, without having to allow extra space for a stirring unit. Protection class IP 21 protects against vertically falling water drops.

Easy integration into existing setups

Because the electronics of the HP 7 are designed exclusively for the heating function, operation is reduced to a single rotary knob for the set temperature, with no scale or control for a speed that does not exist anyway. This makes the unit an uncomplicated addition to setups in which a separate stirrer, for example an overhead stirrer with its own stand, is already available and only a reliable heat source underneath is missing.

Typical applications

As a hotplate without stirring function, the C-MAG HP 7 is technically suited for:

  • Heating vessels and oil baths without a simultaneous need for stirring
  • Combination with separately driven stirrers, for example overhead stirrers
  • Temperature control of reaction blocks or carrier plates from the IKA accessories range
  • Simple heat source in teaching and training laboratories
  • Replacement purchase for workstations where a separate stirrer is already available

Selection guide: hotplate only or heating magnetic stirrer

Within the C-MAG family, IKA basically distinguishes between HS models with stirring and heating and HP models with heating function only:

ModelStirringVolume (H2O)Heating powerPlate size
C-MAG HP 7 (this unit)no10 l1000 W180 x 180 mm
C-MAG HP 4no5 l250 W100 x 100 mm
C-MAG HS 7yes, 100 to 1500 rpm10 l1000 W180 x 180 mm
C-MAG HS 10yes, 100 to 1500 rpm15 l1500 W260 x 260 mm

If stirring is done anyway or a stirrer is not needed at all, the hotplate only saves purchase costs compared with an HS model with the same heating rating. As soon as stirring and heating are required together in one unit, one of the HS models is the more suitable choice.

Differences from the heating magnetic stirrers and the smaller HP 4

The IKA C-MAG HP 4 covers smaller volumes of up to 5 litres with a smaller plate area and 250 watts of heating power and does not have a connection for an external contact thermometer. If stirring is required in addition to heating, the IKA C-MAG HS 7 and the IKA C-MAG HS 10 offer the same heating technology with an integrated stirring drive. For larger heating surfaces of up to 260 x 260 millimetres, IKA also offers the C-MAG HP 10 as a hotplate only, and for smaller batches the C-MAG HS 4 is available as a more compact alternative with stirring function.

Technical details

Number of heating positions1
Heating power1000 W
Heating temperature range50 to 500 °C, rotary knob, setting accuracy 5 K
Connection for external temperature sensorETS-D5 (DIN 12878)
Volume max.10 l
Heating rate5 K/min
Surface materialCeramic
Surface dimensions180 x 180 mm
Permissible relative humidity80 %
Dimensions (W x H x D)220 x 105 x 330 mm
Weight4.4 kg
Protection classIP 21 (DIN EN 60529)
Mains connection230 V, 50/60 Hz, 1005 W (other voltage variants 120 V / 100 V available)

Scope of delivery

  • 1 x IKA C-MAG HP 7 Hotplate (0003581800)

Stirring bars are not included, as the C-MAG HP 7 has no stirring function. An external temperature sensor such as the ETS-D5 is likewise not included in the scope of delivery.

Use, installation, maintenance and disposal

With protection class IP 21, the C-MAG HP 7 is protected against vertically falling water drops and is designed for operation in a fume hood or on a stable, level laboratory bench at up to 80 percent relative humidity. As no stirrer is fitted, the plate is particularly suitable for installation underneath separate stirring drives or stands. Sufficient clearance for cables and accessories should be ensured here. The ceramic surface is chemically resistant but should be allowed to cool before cleaning. At the end of its service life, the hotplate, as an electrical appliance, does not belong in household waste but in separate collection of waste electrical equipment; the manufacturer's WEEE registration number is DE 66784213.

Cost logic: when it pays to do without a stirring function

If a separate stirrer, for example an overhead stirrer, is already in use, or if no stirring is needed for the application at all, the hotplate only saves noticeable purchase costs compared with an HS model with identical heating power, without compromising on the actual heating function. This applies in particular when several workstations with different stirrers are to use the same heating power, for example in practical course rooms with permanently mounted stands. For standard workstations where stirring and heating are typically needed together, an HS model is usually the more economical overall solution, because it makes an additional stirrer unnecessary.

Individual requirements & procurement service

For the C-MAG HP 7, suitable original accessories are available on request, such as the ETS-D5 contact thermometer, stand material, carrier plates, oil bath attachments and reaction blocks of different volumes. Through our procurement service we also support you with spare parts, calibrations and the assembly of several workstations with uniform accessories. For further information and contact options, see lt-laborhandel.com/service.

Frequently asked questions

Can the C-MAG HP 7 also stir?
No, the HP 7 is a hotplate without magnetic stirring drive. The HS models of the C-MAG series are available for this.

Is an external temperature sensor included in the scope of delivery?
No, the connection socket according to DIN 12878 is present, but an ETS-D5 contact thermometer has to be purchased separately.

How does the HP 7 differ from the smaller HP 4?
With 1000 instead of 250 watts, the HP 7 offers a considerably higher heating power, a larger plate of 180 x 180 millimetres and, in addition, a connection for an external contact thermometer, which the HP 4 does not have.

What is the maximum volume that can be heated?
According to the manufacturer, up to 10 litres of water.

Is the HP 7 suitable for an oil bath?
The hotplate itself is designed for direct heat transfer to vessels placed on it. For oil bath applications, IKA offers suitable oil bath attachments in its accessories range, which can be placed on the 180 x 180 millimetre plate.

Does accessory equipment from the HS series also fit the HP 7?
Carrier plates, reaction blocks and oil bath attachments from the IKA accessories range are designed for the 180 x 180 millimetre surface of the HP 7 and are generally also compatible with other C-MAG models of the same plate size, for example the C-MAG HS 7.

How is the C-MAG HP 7 disposed of properly?
As an electrical appliance, it belongs at a collection point for waste electrical equipment rather than in household waste. The manufacturer's WEEE registration number is given in the section Use, installation, maintenance and disposal.

Skip product gallery

Matching accessories

Discount
IKA ETS-D5 electronic contact thermometer with touchscreen, –20 °C to +400 °C, 0025008371
IKA ETS-D5 electronic contact thermometer with touchscreen, –20 °C to +400 °C, 0025008371
Herstellernummer: 0025008371

The new IKA ETS-D5 electronic contact thermometer (MPN 0025008371) completely redefines precision, safety and ease of use in laboratory thermal analysis. Developed as a high-performance mechatronic control unit for demanding laboratory processes, this instrument takes over active, direct temperature control of the medium once connected. It controls the heating power of a coupled magnetic stirrer by intelligently switching the heating plate on and off, whilst the stirrer itself acts as a redundant monitoring unit for the preset safety limits. The ETS-D5 thus transforms any compatible workstation into a future-proof, high-precision control centre for reproducible experimental series. Integrated safety architecture for risk-free processes From a process engineering perspective, the ETS-D5 offers a comprehensive range of sophisticated protective functions that contribute significantly to laboratory safety and risk minimisation. The system features an adjustable sensor timeout, which is triggered immediately if the probe is inadvertently outside the liquid medium. Precise temperature drop detection reacts dynamically to unexpected thermal gradients, whilst setpoint monitoring (Delta T) immediately stops temperature control if the target value is exceeded by a critical margin. To prevent operator errors in multi-user operation, the maximum settable temperature can be strictly limited via a setpoint limit. In the event of a transient fault, the heating circuit remains permanently switched off to protect personnel and the sample matrix. Optimised PID control and application-specific modes The instrument’s control technology ensures absolutely stable temperature control without thermal overshoot. Coupled with a high-precision, interchangeable PT1000 temperature sensor of tolerance class A, the system covers a wide operating range from –20 °C to +400 °C. Three application-specific temperature control modes ensure maximum flexibility in day-to-day laboratory work: ‘Fast’ for ultra-fast heating cycles, ‘Precise’ for working at the minimum tolerance limit, and a specialised synthesis block mode that is perfectly tailored to the thermodynamic requirements of chemical syntheses. For highly sensitive organic or biological sample structures, the heating rate can also be precisely reduced in percentage increments. Ergonomic touch-screen control concept and documentation The instrument’s exterior breaks away from complicated analogue designs and features a user-friendly, clear touchscreen display for intuitive parameter configuration during continuous operation. The almost completely enclosed system reliably protects the internal electronic components from aggressive vapours and liquids in the harsh everyday laboratory environment. A future-proof, integrated USB-C interface also enables the rapid, error-free export of all transient measurement data to a PC, thereby ensuring seamless documentation, validation and traceability of your processes in accordance with modern GLP standards. Technical details Measurement system & control characteristics Sensor type: PT1000 (DIN IEC 751 Class A), easily replaceable Temperature measurement range: –20 °C to +400 °C Measurement and setpoint resolution: 0.1 K Temperature measurement accuracy: ±0.2 K + tolerance of the PT1000 sensor Control accuracy in the medium: ±0.5 K (validated with 500 ml of water in a 600-ml beaker) Temperature control modes: Fast, Precise (highest accuracy), Synthesis block-optimised Heating rate: Individually adjustable in percentage steps for sensitive samples Control algorithm: Optimised PID control to prevent overshoot Safety & monitoring functions Sensor timeout: Detects the absence of the sensor in the medium (time-adjustable) Temperature drop detection: Automatic response to unexpected temperature drops Setpoint monitoring (Delta T): Shuts off the heating function if the Delta T limit is exceeded Setpoint Limitation: Software-based limitation of the maximum settable temperature Safe-Temp & Emergency Protection: Immediate safety shutdown of the heating circuit in the event of a fault; the stirrer remains deactivated Operation, Interfaces & Geometry Display technology: User-friendly, flat touchscreen for intuitive operation Digital interface: USB-C for direct data transfer and software connection to a PC Connector to the main unit: DIN 45322 (MAS6 standard) Dimensions (width x height x depth): 52 x 36 x 385 mm Minimum probe insertion depth: 20 mm Net weight: 0.156 kg (156 grams) Environmental data & electrical specifications Protection class according to DIN EN 60529: IP 54 (dust- and splash-proof) Operating voltage / DC voltage: 8 to 16 V= Current consumption: 100 mA Permissible ambient temperature: +5 to +40 degrees Celsius Permissible relative humidity: Up to 80 per cent Contents of the package 1 x IKA ETS-D5 electronic contact thermometer (MPN: 0025008371) 1 x PT1000 temperature probe (standard version) 1 x USB-C connection cable 1 x Detailed operating instructions / safety guide Individual Requirements & Accessories To ensure optimal utilisation of the intelligent ETS-D5 control centre, we offer a complementary range of original system peripherals: Specialised probes for corrosive media: Optional interchangeable sensors made from robust special-purpose glass (H66.51) or featuring a highly chemically resistant protective coating (H66.53) for safe operation in acids and alkalis. Mechanical mounts: Precisely fitting extension cables for flexible spatial extension of the measuring station, as well as sturdy IKA support rods and cross-couplings for vibration-free stand locking above the sample point. Compatible stirring systems: Ideal as a metrological upgrade for IKA magnetic stirrers without integrated primary temperature control, to establish a redundant, independent medium safety circuit. Use our technical B2B procurement service to configure your measuring stations.

Sale price: €295.80 Manufacturer's RRP: €348.00 15% below manufacturer's RRP