E37418 is a stainless steel perforated tray for Memmert ICO CO₂ incubators and HCP humidity chambers in sizes 105 and 150. Memmert specifies 15 kg as the maximum load per shelf. The total load of the unit is also limited; the values are given in the unit’s data sheet. The table of compatible models shows which series are available in which sizes.

Suitable for

ModelSize
ICO105105
HCP105105
HCP150150

Scope of delivery

  • 1 stainless steel perforated tray
Skip product gallery

Fits

New
Memmert ICO105 CO2 incubator NextGen
Memmert CO2 incubator ICO105 NextGen, 108 L, 6.86-inch touch display
Manufacturer number: ICO105

Pre-order: The ICO105 is part of the new ICO NextGen series. It is available as a pre-order. With an internal volume of 108 litres, the Memmert ICO105 NextGen CO₂ incubator is a medium-sized model in the new NextGen series, offering, according to Memmert, one litre more capacity than the previous ICO105 from the 2012 generation. For laboratories that incubate several culture batches in parallel or require more space than the entry-level ICO50 offers, this size provides ample capacity without having to opt for the next larger model straight away. A touchscreen instead of two separate screens Instead of the previous TwinDISPLAY with two separate TFT screens, the ICO105 NextGen displays actual and target values as well as parameter trends on a 6.86-inch IPS touchscreen with multi-touch functionality (480 x 1280 pixels). Temperature and CO₂ control The temperature can be set from +20 to +50 °C; the operating range extends from at least 5 °C above room temperature up to +50 °C, with a setting accuracy of 0.1 °C. At 37 °C, the temporal temperature fluctuation is ±0.1 K, and the spatial fluctuation is ±0.3 K. CO₂ control covers 0 to 20 % CO₂ as standard, with a setting accuracy of 0.1 % and a temporal fluctuation of ±0.2 % CO₂. Humidity and O₂ as an extension A stainless-steel water tray is supplied as standard. Option K7 extends the ICO105 to include active humidity control from 40 to 98 % rh, including a ‘rh off’ function, with a setting accuracy of 0.1 % rh, utilising a self-priming micro-dosing pump with a hot steam generator for humidification and a diaphragm pump for dehumidification. Option T6 (requires Option K7) additionally controls the oxygen concentration via nitrogen injection in the range 1 to 20 % O₂, with an accuracy of 0.1 %. Glass doors and battery storage as additional options Unlike the smaller ICO50, the ICO105 offers Option K4: two internal doors with glass panels instead of the solid stainless-steel door, which is practical for a quick glance inside the unit without altering the internal climate. Also available as an option is an integrated battery storage unit (Option C2), which allows the display unit to continue operating without interruption in the event of a power cut, ensuring seamless documentation of all parameters even during a power cut. Sterilisation without removing sensors A pre-programmed cycle sterilises the interior in 60 minutes at +180 °C without the need to remove the sensors beforehand. Interior, door and shelves The deep-drawn interior is made of stainless steel grade 1.4301 (ASTM 304). The fully insulated stainless steel door closes with a 2-point compression lock and features an internal glass door. A stainless steel perforated shelf is supplied as standard; up to 5 shelves can be fitted, with a maximum load of 15 kg per shelf and 75 kg per unit. Interfaces and software The ICO105 NextGen features USB-C and Ethernet LAN. The chargeable software application myChamber LIMS is available for connection to a LIMS, whilst the connectivity package for the myChamber Monitoring App is available for permanent remote monitoring. For electronic signatures according to 21 CFR Part 11, the basic licence FDAQ1 for AtmoCONTROL FDA and myChamber Control FDA can be added. None of the three options is included as standard. Operation and connected load specifications The ICO105 NextGen is rated for 230 V, 50/60 Hz; Option X2 converts it to 115 V at no extra cost, and the power consumption is approximately 1,450 W. The textured stainless steel housing measures 708 x 683 x 589 mm (width x height x depth), plus a 50 mm allowance for the door handle; the internal dimensions are 560 x 480 x 400 mm. The net weight is 70 kg; when packed, it weighs 85 kg. Other sizes in the ICO NextGen series In addition to the ICO105 (108 litres), we offer the ICO50 (56 litres) for smaller batches, as well as the ICO180 (177 litres, according to Memmert the successor to the previous ICO150) and the ICO240 (243 litres) for higher throughput, each featuring the same operating concept. Typical applications With controlled temperature and CO₂ concentration, as well as an optional glass door, the ICO105 NextGen is suitable for: Parallel incubation of multiple culture batches in medium-sized laboratories Microbiological, pharmaceutical and biotechnological research requiring documented environmental conditions Laboratory operations where visual monitoring via glass doors (Option K4) reduces the change in climate when the door is opened Processes requiring complete documentation even in the event of a power cut (Option C2) Technical details Internal volume108 litres Internal dimensions (W x H x D)560 x 480 x 400 mm (depth minus 37.5 mm for the fan) Cabinet dimensions (W x H x D)708 x 683 x 589 mm (plus 50 mm door handle) Interior materialStainless steel grade 1.4301 (ASTM 304), deep-drawn Temperature setting range+20 to +50 °C Operating temperature rangeat least 5 °C above room temperature up to +50 °C Temperature accuracy0.1 °C (temporal variation at 37 °C ±0.1 K, spatial ±0.3 K) CO₂ control0 to 20 % CO₂, accuracy 0.1 %, temporal variation ±0.2 % CO₂ Humidity control (Option K7)40 to 98 % rh and rh-Off, accuracy 0.1 % rh O₂ control (Option T6, requires K7)1 to 20 % O₂, accuracy 0.1 % Control unit6.86" IPS touchscreen (480 x 1280 pixels), multi-touch DoorFully insulated stainless steel door, 2-point locking, internal glass door (optional: 2 doors with glass cut-outs, Option K4) Shelves1x stainless steel perforated shelf as part of the scope of delivery, up to 5 possible Max. load75 kg total / 15 kg per shelf Installation4 adjustable feet InterfacesUSB-C, Ethernet LAN Factory calibration certificate+37 °C, 5 % CO₂ (standard; with option K7 additionally 90 % rh, with K7 and T6 additionally 10 % O₂) Voltage/Power230 V, 50/60 Hz, approx. 1,450 W (Option X2: 115 V at no extra charge) Net weight/Gross weight70 kg / 85 kg Scope of delivery 1x Memmert ICO105 NextGen CO₂ incubator (basic unit) 1x stainless steel perforated shelf 1x stainless steel water tray 1x CO₂ connection set (hose with connector and hose clamp) 1x factory calibration certificate (+37 °C, 5 % CO₂) Not included in the scope of delivery: active humidity control (Option K7), O₂ control (Option T6), glass doors (Option K4), the battery storage unit (Option C2) and the water canister with connection hose (only when Option K7 is ordered) are additional options, as are the software licences for myChamber LIMS, the Monitoring App and FDAQ1. Regulatory information Manufacturer’s WEEE registration number (Memmert GmbH + Co. KG, Stiftung EAR): DE 66812464. The ICO105 NextGen is not a medical device. Memmert is discontinuing the separate, previous ICOmed medical device series (last order 6 November 2026); according to Memmert, the ICO NextGen is currently undergoing testing and qualification to also meet the requirements for medical applications; this is an announcement, not an approval that has already been granted. Individual requirements and procurement service Memmert units bought from us are covered for three years from delivery: the first 12 months are followed by a 24-month warranty under Memmert’s terms, handled through us. Your statutory rights remain unaffected. Our procurement service can assist you with additional stainless steel perforated shelves, the K7, T6, K4 or C2 options, a stacking set for two ICO105 units of the same size (item no. B72335) or a bespoke calibration. As factory options, Memmert also offers DAkkS calibration according to DKD-R 5-7, IQ/OQ documents and IQ/OQ qualification. We order these with the device on request.

Manufacturer's RRP: €5,231.00
Memmert Humidity Chamber HCP105, 107 l, +18 to +90 °C, 20 to 95 % rh
Memmert Humidity Chamber HCP105, 107 l, +18 to +90 °C, 20 to 95 % rh
Manufacturer number: HCP105

The Memmert Humidity Chamber HCP105 comes with two stainless steel perforated trays from the factory, and up to six shelves are possible. The internal volume is 107 litres, and the interior measures 560 x 480 x 400 mm (W x H x D, depth reduced by 35 mm for the fan). Temperature and relative humidity are actively controlled: +18 to +90 °C and 20 to 95 % rh, also settable with rh-Off. Operation is via the ControlCOCKPIT TwinDISPLAY.Housing, weight and loadingExternally the HCP105 measures 719 x 850 x 591 mm plus 56 mm door handle, and the net weight is approx. 75 kg. The whole unit may be loaded with 90 kg, and each of the six possible shelves with 15 kg. The interior is made of stainless steel 1.4301 (ASTM 304). Behind the outer door sits a heated inner glass door, and the outer door is fully insulated and has 2-point locking. For supply lines there is a humidity-tight silicone feedthrough with 40 mm inner diameter in the rear wall, centre left. The chamber is transported upright.Humidity control and water supplyHumidity is supplied by a self-priming pump that draws from an external container. The water canister with connection hose is supplied with the chamber. The germ barrier is implemented as hot steam generation, and dehumidification runs via a sterile filter. The water must be demineralised or fully deionised, with a conductivity of 5 to 10 µS/cm and a pH value between 5 and 7. A central water supply for connection to the domestic water supply is available as an accessory. The setting accuracy of humidity is 0.5 % rh. To avoid condensate formation, door and rear wall are additionally heated, plus all-round heating on six sides.Programming and documentationWith AtmoCONTROL, programs can be written, managed and transferred to the chamber via Ethernet or USB. The digital countdown clock ranges from 1 minute to 99 days and shows the target time. SetpointWAIT lets the process time run only from the point when the setpoint temperature has been reached. Three values each for temperature and humidity can be freely calibrated. Also settable are Celsius or Fahrenheit, time zone and summer and winter time. If the power fails, the program sequence remains saved.Fault detection and protectionThe two Pt100 sensors (DIN class A, 4-wire measurement) check each other, and in the event of a fault the remaining sensor takes over. AutoSAFETY tracks a freely selectable upper and lower temperature limit to the setpoint. If it is violated, the chamber gives a visual and acoustic alarm, and when exceeded the heating switches off. The self-diagnosis system covers temperature and humidity control. The environment may be 10 to 30 °C warm and at most 70 % rel. humidity, non-condensing, and the installation altitude is at most 2,000 m above sea level. At the back, 15 cm of wall distance are to be kept, 20 cm at the top, 5 cm at the sides.HCP105, HCP50 or HCP150Compared with the HCP50 (56 l, 5 shelves, 75 kg), the HCP105 brings about twice the volume and a sixth shelf. Upwards follows the HCP150 with 156 l, ten shelves and 120 kg total load. The ICH110 climate chamber has almost the same volume at 108 l, but sets -10 to +60 °C and 10 to 80 % rh. Anyone who wants to go up to +90 °C and 95 % rh stays with the HCP.Typical applicationsThe HCP series is intended for these applications:Environmental testingEnvironmental simulationsAccelerated lifetime tests85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78Technical detailsInternal volume107 lInternal dimensions (W x H x D)560 x 480 x 400 mm (D less 35 mm for fan)External dimensions (W x H x D)719 x 850 x 591 mm (D plus 56 mm door handle)Weight netapprox. 75 kgShelvesmax. 6, of which 2 perforated trays as standardMaximum load90 kg total, 15 kg per shelfSetting temperature range+18 to +90 °CWorking temperature range7 °C above room temperature to +90 °CSetting accuracy temperature0.1 °CSetting range humidity20 to 95 % rh and rh-OffSetting accuracy humidity0.5 % rhSensors2x Pt100 DIN class A, 4-wire measurementControlControlCOCKPIT TwinDISPLAY, adaptive PID microprocessor controllerWaterdemineralised or fully deionised, 5 to 10 µS/cm, pH 5 to 7Electrical connection 230 V50/60 Hz, approx. 1,720 WInterfacesEthernet LAN, USBEnvironment10 to 30 °C, max. 70 % rel., non-condensingMax. installation altitude2,000 m above sea levelMarkingsCE, VDE GS, cMETusOther sizes in the seriesThe HCP humidity chambers come in four sizes from 56 to 241 litres, each with TwinDISPLAY:ModelInternal volumeSetting temperatureHumidity rangeHCP5056 l+18 to +90 °C20 to 95 % rhHCP105 (this page)107 l+18 to +90 °C20 to 95 % rhHCP150156 l+18 to +90 °C20 to 95 % rhHCP240241 l+18 to +90 °C20 to 95 % rhScope of delivery1x Memmert Humidity Chamber HCP1052x stainless steel perforated trayFactory calibration certificate for 60 °C at 75 % rh (measuring room centre of usable space)Heated inner glass doorFully insulated stainless steel door, 2-point locking (compression door lock)Silicone feedthrough with 40 mm inner diameter, rear wall, centre leftWater canister including connection hoseRegulatory informationThe unit is an electrical device within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer Memmert GmbH + Co. KG is DE 66812464. Notes on returning old appliances can be found on our page Environment and disposal.Individual requirements and procurement serviceFactory options for the HCP105, specified when ordering, are: 115 V connection voltage, lateral 23 mm feedthrough left or right, 4-20 mA outputs for the actual value of temperature and humidity, a lockable door, a potential-free fault message contact and MobileALERT for alarm notification by SMS (requires the fault message contact). Accessories listed include, among others, further perforated trays and grid shelves, the central water supply with or without filter cartridges, USB-Ethernet adapter, Ethernet cable (5 m), USB user ID stick, FDA licence, stacking kit and base frames (130 mm or 622 mm levellable). Calibration at the factory or according to DAkkS, IQ/OQ documents and on-site maintenance can be ordered in addition. Send us your requirements, and we will put together the suitable package.

Manufacturer's RRP: €7,495.00
Memmert Humidity Chamber HCP150, 156 l, +18 to +90 °C, 20 to 95 % rh
Memmert Humidity Chamber HCP150, 156 l, +18 to +90 °C, 20 to 95 % rh
Manufacturer number: HCP150

Ten shelves in 156 litres: the Memmert Humidity Chamber HCP150 is the third of four sizes in the HCP series and, with 700 mm internal height, considerably taller than the HCP105 with 480 mm at the same internal area of 560 x 400 mm. Externally it measures 719 x 1,070 x 591 mm plus 56 mm door handle. Temperature (+18 to +90 °C) and relative humidity (20 to 95 % rh, also rh-Off) are controlled by the ControlCOCKPIT TwinDISPLAY.Ten levels, 120 kg total loadAs standard, two stainless steel perforated trays are in the interior made of stainless steel 1.4301 (ASTM 304), and a maximum of ten shelves fit in. 15 kg apply per shelf, and 120 kg for the whole unit. The net weight is approx. 90 kg, and the connected load at 230 V approx. 1,800 W. The permanently installed parts include a heated inner glass door behind the fully insulated stainless steel door (2-point locking) and a humidity-tight silicone feedthrough with 40 mm inner diameter in the rear wall, centre left.Humidity from the canisterA water canister with connection hose is part of the scope of delivery. A self-priming pump supplies the water, the germ barrier works with hot steam generation, and dehumidification runs via a sterile filter. Only demineralised or fully deionised water comes into question, with 5 to 10 µS/cm conductivity and a pH value of 5 to 7. For alternatives for the water supply, such as a connection to the domestic water supply, we advise on request. Humidity can be set to an accuracy of 0.5 % rh, and temperature to 0.1 °C. Against condensate, heating on six sides, door heating and rear wall heating are at work.Control and data retentionThe TwinDISPLAY forms the ControlCOCKPIT: an adaptive, digital PID microprocessor controller with two high-resolution TFT colour graphic displays. Programs are created with the AtmoCONTROL software and reach the chamber via Ethernet or USB. The countdown clock covers 1 minute to 99 days, and SetpointWAIT waits for the setpoint temperature before starting the process time. Three values each for temperature and humidity are available for calibration. In the event of a power failure, the program sequence is saved. The menu languages range from German through Polish and Hungarian to Chinese.Protective functionsTwo Pt100 sensors (DIN class A, 4-wire measurement) monitor each other and step in for one another in the event of a fault. AutoSAFETY switches the heating off when the freely selectable interval to the setpoint is exceeded and alarms visually and acoustically when exceeded or fallen below. The self-diagnosis system concerns the temperature and humidity control. The permissible environment is 10 to 30 °C at a maximum of 70 % rel. humidity (non-condensing) and an altitude up to 2,000 m above sea level. The chamber is transported upright. It needs 15 cm to the wall at the back, 20 cm to the ceiling and 5 cm at the sides.Between HCP105 and HCP240The HCP105 has the same internal area, but only six shelves and 90 kg total load. The HCP240 (241 l, twelve shelves, 140 kg) is 600 mm wide and 500 mm deep inside. Anyone looking for a larger volume in a climate chamber with a different range will find 256 l at -10 to +60 °C and 10 to 80 % rh in the ICH260. The HCP150, by contrast, covers +18 to +90 °C and 20 to 95 % rh.Typical applicationsApplications of the HCP series include:Environmental testingEnvironmental simulationsAccelerated lifetime tests85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78Technical detailsInterior volume156 lInternal dimensions (W x H x D)560 x 700 x 400 mm (D less 35 mm for fan)External dimensions (W x H x D)719 x 1,070 x 591 mm (D plus 56 mm door handle)Net weightapprox. 90 kgShelves10 maximum, 2 perforated trays as standardPermissible load120 kg unit, 15 kg per shelfTemperature, setting range+18 to +90 °CTemperature, working range7 °C above room temperature to +90 °CTemperature, setting accuracy0.1 °CHumidity, setting range20 to 95 % rh and rh-OffHumidity, setting accuracy0.5 % rhSensors2x Pt100, DIN class A, 4-wire measurementDisplay and controllerTwinDISPLAY, adaptive PID microprocessor controller, 2x TFTWater quality5 to 10 µS/cm, pH 5 to 7, demineralised or fully deionisedMains connection 230 V50/60 Hz, approx. 1,800 WInterfacesEthernet LAN and USBInstallation conditions10 to 30 °C, max. 70 % rel. (non-condensing), up to 2,000 m above sea levelMarkingsCE, VDE GS, cMETusOther sizes in the seriesAll four sizes of the HCP series share the temperature and humidity range and differ in volume:ModelInternal volumeSetting temperatureHumidity rangeHCP5056 l+18 to +90 °C20 to 95 % rhHCP105107 l+18 to +90 °C20 to 95 % rhHCP150 (this page)156 l+18 to +90 °C20 to 95 % rhHCP240241 l+18 to +90 °C20 to 95 % rhScope of deliveryMemmert Humidity Chamber HCP150 (basic unit)2 stainless steel perforated traysFactory calibration certificate (measuring room centre of usable space), 60 °C at 75 % rhAdditional heated glass door insideFully insulated stainless steel door with 2-point locking (compression door lock)Humidity-tight silicone feedthrough, inner diameter 40 mm, rear wall, centre leftWater canister including connection hoseRegulatory informationThe unit is an electrical device within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer Memmert GmbH + Co. KG is DE 66812464. Notes on returning old appliances can be found on our page Environment and disposal.Individual requirements and procurement serviceFor the HCP150 there are factory options, specified when ordering, and suitable accessories. Which variants are available for your application, we clarify with Memmert on request. The same applies to calibrations and qualification documents. Write to us with what the chamber is to achieve. We will prepare a quotation with the suitable equipment. As factory options, Memmert also offers DAkkS calibration according to DKD-R 5-7, IQ/OQ documents and IQ/OQ qualification. We order these with the device on request.

Manufacturer's RRP: €9,706.00