Skip to main content Skip to search Skip to main navigation

Residue Fragrance Allergen Standards Kit, 33105

Product information "Residue Fragrance Allergen Standards Kit, 33105"

Description:
To protect consumers with allergies, the 7th Amendment to the European Cosmetics Directive stipulates that finished cosmetic products and personal care products must state whether they contain excessive amounts of any allergen from a list of 26 compounds. Of these 26 compounds, 24 are volatile chemicals that can be identified by GC-MS analysis, and Version 3 of the method described by the International Fragrance Association (IFRA) serves precisely this purpose.

This specially formulated reference standard kit exceeds IFRA’s purity requirements and contains all 24 fragrance allergens defined by the EU that can be detected by GC-MS, as well as seven further potential allergens. When analysed on a Restek Rxi-17 column using the IFRA method, all the desired compounds and isomers are clearly resolved without co-elutions. This time-saving mixture is also incredibly robust and has a shelf life of over one and a half years, allowing you to keep a pre-prepared standard in stock rather than preparing a new batch for each analysis.

Whether you manufacture fragrances in Europe, sell to European consumers or simply wish to test for allergens in your products, choose the reference standard mixture that helps you comply with the IFRA methodology in a practical, long-lasting formulation.

This kit contains one ampoule (in methyl tert-butyl ether) of each of the following.

33100: MTBE Solvent Blank††
methyl tert-butyl ether (MTBE) (1634-04-4), neat

33101: 1-Fluoronaphthalene (Internal Standard)††
1-fluoronaphthalene (321-38-0), 20 µg/mL

33102: Fragrance Allergen Standard A (Includes Internal Standard)††
α-amylcinnamaldehyde*† (122-40-7), 400 µg/mL
cinnamal* (104-55-2), 400 µg/mL
citral*† (5392-40-5), 400 µg/mL
3,7-dimethyl-7-hydroxyoctanal* (107-75-5), 400 µg/mL
1-fluoronaphthalene (321-38-0), 20 µg/mL
α-hexylcinnamaldehyde*† (101-86-0), 400 µg/mL
lilial* (80-54-6), 400 µg/mL
lyral*† (31906-04-4), 400 µg/mL
phenylacetaldehyde** (122-78-1), 400 µg/mL

33103: Fragrance Allergen Standard B (Includes Internal Standard)††
α-amylcinnamic alcohol*† (101-85-9), 400 µg/mL
benzyl alcohol* (100-51-6), 400 µg/mL
cinnamyl alcohol* (104-54-1), 400 µg/mL
citronellol* (106-22-9), 400 µg/mL
eugenol* (97-53-0), 400 µg/mL
farnesol*† (4602-84-0), 400 µg/mL
1-fluoronaphthalene (321-38-0), 20 µg/mL
geraniol* (106-24-1), 400 µg/mL
isoeugenol* (97-54-1), 400 µg/mL
linalool* (78-70-6), 400 µg/mL
4-methoxybenzyl alcohol* (105-13-5), 400 µg/mL
methyl eugenol** (93-15-2), 400 µg/mL

33104: Fragrance Allergen Standard C (includes internal standard)††
4-allylanisole** (140-67-0), 400 µg/mL
benzyl benzoate* (120-51-4), 400 µg/mL
benzyl cinnamate* (103-41-3), 400 µg/mL
benzyl salicylate* (118-58-1), 400 µg/mL
camphor** (76-22-2), 400 µg/mL
1,8-cineole** (470-82-6), 400 µg/mL
coumarin* (91-64-5), 400 µg/mL
1-fluoronaphthalene (321-38-0), 20 µg/mL
d-limonene* (5989-27-5), 400 µg/mL
iso-α-methylionone* (127-51-5), 400 µg/mL
methyl 2-nonynoate** (111-80-8), 400 µg/mL
methyl 2-octynoate* (111-12-6), 400 µg/mL
safrole** (94-59-7), 400 µg/mL

To view and download safety data sheets (SDS) and certificates of analysis (CofA) for recently produced batches, visit www.restek.com/documentation-search and then enter the cat.# for each ampoule.

*Compound listed in the 7th Amendment to the European Cosmetics Directive.
**Additional potential allergens included in this formulation.
†Compounds defined as two isomers resulting in two chromatographic peaks.
††Components of the Fragrance Allergen Standards Kit are not available for individual sale.

Features and benefits
: - For the complete separation of 31 fragrance allergens through a single analysis on an Rxi-17 column
.- Ideal for GC-MS analyses according to the IFRA method
.- Helps you to comply with the EU requirements set out in the European Cosmetics Directive.
- All components included have a concentration of 400 ppm, allowing for dilution for calibration curves
and use with various solvents.- Exceeds the purity requirements specified in the IFRA method.

Technical specifications
: - Catalogue number:
33105- Product name: Fragrance Allergen Standards Kit-
Certified Reference Material (CRM): Yes-
Maximum shelf life from date of dispatch (months):
18- Minimum shelf life from date of dispatch (months): 6-
Shipping conditions: ambient
temperature- Storage temperature: 0 °C or colder-
Units: kit