Restek Rtx-5ms GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 12623

Product information "Restek Rtx-5ms GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 12623"

The Rtx-5ms has a stationary phase of 5 % diphenyl and 95 % dimethyl polysiloxane, crosslinked on fused silica. It is 30 m long, with an inner diameter of 0.25 mm and a film thickness of 0.25 µm. The column is tested to strict specifications for low column bleed and high inertness.

Polarity, USP and equivalents

The polarity matches the Rtx-5, and column bleed is lower. The phase is listed under the USP designations G27 and G36. From other manufacturers, the following are considered comparable: Agilent DB-5, HP-5, HP-5ms, Ultra-2 and CP-Sil 8 CB, Phenomenex ZB-5 and ZB-5MS, and Supelco SPB-5. Comparable column part numbers are Agilent 19091S-433 and Scion/Bruker/Varian CP5860.

Temperature range

The Rtx-5ms withstands up to 330 °C isothermal and 350 °C programmed, with a lower limit of -60 °C. The first temperature value applies to isothermal operation, the second to temperature programs.

Which 5-phase fits

Among the 30 m columns with a 5-phase in the shop, the phase and temperature limits differ, and for the Rtx-5 the dimensions as well. The Rtx-5 has the same polarity, but 0.32 mm ID and 1.00 µm film thickness.

ColumnPhaseDimensions and temperature
Rtx-5ms (this page)5 % diphenyl, 95 % dimethyl polysiloxane30 m, 0.25 mm ID, 0.25 µm, -60 to 330/350 °C
Rtx-5Diphenyl dimethyl polysiloxane30 m, 0.32 mm ID, 1.00 µm, -60 to 325/350 °C
Rxi-5msDiphenyl dimethyl polysiloxane30 m, 0.25 mm ID, 0.25 µm, -60 to 330/350 °C
Rxi-5Sil MSSilarylene phase, phenyl groups in the polymer backbone30 m, 0.25 mm ID, 0.25 µm, -60 to 320/350 °C

Bleed and detector

Column bleed occurs when degradation products of the stationary phase elute from the column, especially at high temperatures. It raises the baseline and increases background noise at the detector. On the Rtx-5ms, bleed is expressly a test criterion. The Rtx-5 also has extremely low column bleed, and on the Rtx-5ms it is lower still.

Typical applications

  • General-purpose column, also for pharmaceuticals
  • Solvent impurities
  • Pesticides
  • Hydrocarbons
  • PCB congeners, for example Aroclor mixtures
  • Essential oils
  • Semivolatiles

PCB congeners are the individual polychlorinated biphenyls, and Aroclor is the trade name of technical PCB mixtures. Semivolatiles (SVOCs) have a higher boiling point than the classic volatile organic compounds.

Technical details

ManufacturerRestek
PhaseRtx-5ms
Phase type5 % diphenyl, 95 % dimethyl polysiloxane, crosslinked, low polarity
PolarityNon-polar
USP phaseG27, G36
Length30 m
Inner diameter0.25 mm
Film thickness0.25 µm
Column materialFused silica
Temperature range-60 °C to 330 °C isothermal, 350 °C programmed
Packaging unit1 piece
UNSPSC41115710
Part number12623

Scope of delivery

One capillary column is supplied as a single piece.

Individual requirements and procurement service

Restek offers the Rtx-5ms in further dimensions. LT procures these on request, as well as other Restek phases, liners and accessories. The request can be made with the Restek part number or with length, inner diameter and film thickness. Quantity and delivery address help with the quote. Matching Restek liners and reference standards can be ordered in the same request.