Restek Rxi-624Sil MS GC Capillary Column, 30 m, 0.32 mm ID, 1.80 µm, 13870
€848.00
% Manufacturer's RRP: €942.00 9% below manufacturer's RRP
- Rxi-624Sil MS in 30 m, 0.32 mm ID and 1.80 µm film
- Crossbond phase of medium polarity on fused silica
- Usable from -20 °C to 300 °C isothermal, 320 °C programmed
- Assigned: alkylfurans, nitrosamines, solvents, terpenes
- Low column bleed, inert surface
Product information "Restek Rxi-624Sil MS GC Capillary Column, 30 m, 0.32 mm ID, 1.80 µm, 13870"
Of the four dimensions, the Rxi-624Sil MS 13870 has the largest inner diameter (0.32 mm) and the thickest film layer (1.80 µm), at 30 m length. Alkylfurans, nitrosamines, solvents and terpenes are assigned as analyte groups.
Phase
Rxi-624Sil MS is a crosslinked Crossbond phase of medium polarity on a fused silica tube. Column bleed is low, thermal stability high and the surface inert. The columns are manufactured for column-to-column reproducibility and are well suited to validated methods.
Comparable phases from other manufacturers include Agilent VF-624ms, Phenomenex ZB-624plus and Quadrex 007-502, 007-624 and 007-608. Comparable part numbers are Agilent CP9104 and Phenomenex 7HM-G040-31. The USP phase class G43 serves for matching methods that name a phase class.
Temperature
The range of use starts at -20 °C. Upwards, 300 °C isothermal and 320 °C in a temperature program are permitted, depending on whether the oven temperature stays constant or follows a program.
Selection within the family
Anyone looking for the narrower cross-section at 30 m length will find it in 13868 with 0.25 mm ID and 1.40 µm film, that is 0.07 mm less inner diameter and 0.40 µm less film thickness than here. The 60 m column 13869 has the same values at twice the length. At the narrow end is 13865 with 20 m, 0.18 mm ID and 1.00 µm. Retention times change when the dimension changes, so the method has to be revalidated afterwards.
| Part number | Length | Inner diameter | Film thickness | Analyte groups | Difference to this column |
|---|---|---|---|---|---|
| 13865 | 20 m | 0.18 mm | 1.00 µm | Solvents, terpenes | -10 m, -0.14 mm, -0.80 µm |
| 13868 | 30 m | 0.25 mm | 1.40 µm | Nitrosamines, solvents, terpenes | -0.07 mm, -0.40 µm |
| 13869 | 60 m | 0.25 mm | 1.40 µm | Solvents, terpenes | +30 m, -0.07 mm, -0.40 µm |
Typical applications
Volatile organics, terpenes and residual solvents (G43 phase). For the dimension 0.32 mm and 1.80 µm, alkylfurans and nitrosamines are also listed as analyte groups.
Technical details
| Part number | 13870 |
|---|---|
| Product line | Rxi GC columns |
| Phase | Rxi-624Sil MS |
| Phase composition | Crosslinked Crossbond phase, medium polarity |
| Polarity | Intermediate |
| Length | 30 m |
| Inner diameter | 0.32 mm |
| Film thickness | 1.80 µm |
| Column material | Fused silica |
| Lower temperature limit | -20 °C |
| Upper temperature limit isothermal | 300 °C |
| Upper temperature limit programmed | 320 °C |
| USP phase class | G43 |
| Analyte groups | Alkylfurans, nitrosamines, solvents, terpenes |
| Pack contents | 1 piece (single column) |
Scope of delivery
One capillary column (single piece) in the stated dimension is supplied. The part number defines length, inner diameter and film thickness unambiguously.
Individual requirements and procurement service
Besides the four dimensions in the shop, Restek offers further versions of the Rxi-624Sil MS and a wide selection of other phases and accessories. LT Laborhandel procures them on request, including by Restek part number. Give us the phase and dimensions, and we will take care of the rest.