Restek Rxi-SVOCms GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 16623
€750.00
% Manufacturer's RRP: €833.00 9% below manufacturer's RRP
- Proprietary phase of the 5 % phenyl type, non-polar
- 30 m, 0.25 mm ID, 0.25 µm film thickness
- Maximum temperature 340 °C isothermal and programmed
- Low bleed for GC-MS, consistent performance from column to column
- For semivolatile compounds (SVOCs) and PAHs
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Restek Rxi-SVOCms GC Capillary Column, 30 m, 0.25 mm ID, 0.25 µm, 16623"
The Rxi-SVOCms is a GC-MS column for semivolatile compounds (SVOCs) and PAHs in complex matrices. The phase is proprietary, of the 5 % phenyl type, and classed as non-polar. The column is 30 m long, with an inner diameter of 0.25 mm and a film thickness of 0.25 µm, and was added to the Restek range in 2022.
Bleed and reproducibility
The bleed level is low for GC-MS, and performance is consistent from column to column. After a loss of performance, trimming the column can restore it. The phase carries the USP designations G27 and G36. The maximum temperature is 340 °C, both isothermal and programmed.
Calibration
For calibration there are the SVOC MegaMix reference standard kits with the Restek part numbers 31907 and 31908. We procure them with the column on request.
Equivalents at a glance
Anyone switching from another brand will find the phase under the following designations:
| Manufacturer | Comparable phases | Comparable column part numbers |
|---|---|---|
| Agilent | DB-UI 8270D, DB-5ms, DB-5ms UI | 122-9732, 122-5532, 122-5532UI |
| Phenomenex | ZB-SemiVolatiles | 7HG-G027-11 |
Other Rxi columns in the shop
The Rxi-SVOCms is designed for SVOCs in complex matrices and PAHs, and PAHs are also among the fields of use of the Rxi-XLB. For PAHs with narrow inner diameter and thin film there is the Rxi-PAH, and for general 5-phase methods the Rxi-5ms and the Rxi-5Sil MS.
| Column | Phase | Dimensions and temperature |
|---|---|---|
| Rxi-SVOCms (this column) | proprietary, 5 % phenyl type | 30 m, 0.25 mm ID, 0.25 µm, up to 340 °C |
| Rxi-5ms | Diphenyl dimethyl polysiloxane | 30 m, 0.25 mm ID, 0.25 µm, -60 to 330/350 °C |
| Rxi-5Sil MS | Silarylene phase, phenyl groups in the polymer backbone | 30 m, 0.25 mm ID, 0.25 µm, -60 to 320/350 °C |
| Rxi-PAH | proprietary, medium polarity | 40 m, 0.18 mm ID, 0.07 µm, 40 to 350/360 °C |
Temperature limit
The upper limit is 340 °C, both isothermal and in a temperature program. The 5-phases in the shop allow 350 °C programmed, the Rxi-SVOCms does not.
Dimensions compared
Compared with the Rxi-PAH (40 m, 0.18 mm ID, 0.07 µm), the Rxi-SVOCms with 30 m, 0.25 mm ID and 0.25 µm film thickness is shorter, larger in inner diameter and more thickly coated. It covers SVOCs and PAHs, while the Rxi-PAH is designed for PAHs.
Typical applications
- Semivolatile compounds (SVOCs) in complex matrices
- PAHs
SVOC stands for semivolatile organic compounds. PAHs are polycyclic aromatic hydrocarbons.
Technical details
| Manufacturer | Restek |
| Phase | Rxi-SVOCms |
| Phase type | Proprietary, 5 % phenyl type |
| Polarity | Non-polar |
| USP phase | G27, G36 |
| Length | 30 m |
| Inner diameter | 0.25 mm |
| Film thickness | 0.25 µm |
| Column material | Fused silica |
| Maximum temperature | 340 °C isothermal and programmed |
| Packaging unit | 1 piece |
| UNSPSC | 41115710 |
| Part number | 16623 |
Scope of delivery
One GC capillary column.
Individual requirements and procurement service
Restek offers further Rxi columns for GC-MS. LT procures the matching dimension on request, as well as reference standards, liners and further accessories, by Restek part number if desired. Quantity and delivery address help us prepare the quote. Anyone who needs several columns or accessories can combine everything in one request.