Binder B 28 Standard Incubator with mechanical control, 28 litres, B028-230V
€1,049.00
% Manufacturer's RRP: €1,353.00 22% below manufacturer's RRP
- Standard incubator with mechanical control
- Temperature range 30 to 70 °C
- 28 litres usable volume
- Compact and lightweight, 580 x 425 x 405 mm, 23 kg
- Simple, cost-effective basic configuration
- Suitable for teaching, training and simple laboratory applications
ⓘ This product description has been translated from German using AI. Despite careful review, we do not guarantee that the translation is error-free; in case of doubt, the German version shall prevail.
Product information "Binder B 28 Standard Incubator with mechanical control, 28 litres, B028-230V"
The Binder B 28 is a simple, mechanically controlled standard incubator with a 28-litre usable volume for a temperature range of 30 to 70 °C. Unlike the other BINDER standard incubators in the BD and BF series, the B 28 does not feature a digital display or electronic control: the temperature is set mechanically. This makes the unit a simple, cost-effective basic option for applications where no digital control or documentation function is required.
Mechanical control instead of digital control
The B 28 is a legacy model in the BINDER range that deliberately does not feature electronic control technology. The temperature is set via a mechanical control; there is no digital display and no programming function, as offered by the electronically controlled BD or BF models. For applications where a simple, robust basic unit is sufficient, such as in teaching or training, this is not a disadvantage, but rather a deliberate decision to avoid complexity that is not required in these contexts. Anyone requiring a digital display, programme memory or data logging would be better served by the electronically controlled BINDER standard incubators in the BD or BF series.
Compact basic configuration for teaching and training
With external dimensions of 580 x 425 x 405 mm (W x D x H) and a weight of 23 kg, the B 28 is the most compact and lightest model amongst the BINDER standard incubators considered here. The connected load is 0.25 kW. This combination of compact design and simple operation makes the B 28 an option for training institutions and cost-conscious procurement where basic functionality is sufficient.
Typical applications
- Basic incubation tasks in training and school lessons
- Simple incubation of culture media without the need for digital documentation
- Cost-effective procurement for laboratories with straightforward requirements
- Supplementary unit for smaller sample quantities alongside electronically controlled main units
Selection guide: B 28 or an electronically controlled model
Anyone requiring a digital display, programmability or data logging will find a suitable alternative in the electronically controlled BD and BF series:
| Model | Useful volume | Control | External dimensions (W x D x H) | Weight |
|---|---|---|---|---|
| B 28 (this appliance) | 28 l | mechanical | 580 x 425 x 405 mm | 23 kg |
| BD 023 | 20 l | electronic | 435 x 520 x 495 mm | 27 kg |
| BF 056 | 59 l | electronic | 560 x 565 x 625 mm | 39 kg |
With a capacity of 20 litres, the BD 023 offers a slightly smaller usable volume than the B 28, but features electronic control with a digital display. For those requiring greater capacity and additional active air circulation, the BF 056, with a 59-litre capacity, provides a larger, electronically controlled alternative. For straightforward incubation tasks without the need for documentation, however, the B 28 remains an option within the BINDER standard incubator range.
Distinction: mechanically controlled and electronically controlled models
The BD series, with which the B 28 is primarily compared here, is marketed by BINDER as the Avantgarde.Line featuring a digital controller and LCD display. The B 28, on the other hand, is, according to the data sheet, a legacy model outside this current product line structure, without a digital display or an interface. Within the electronically controlled models, the operating principle also differs: the BD series operates using natural convection, whilst the BF series uses active air circulation; the BD series is available from 20 litres, the BF series from 59 litres. If a temperature below room temperature is required, none of the three series mentioned covers this range; for this, a cooling incubator from the KB series, such as the Binder KB 065 with a temperature range of 0 to 70 °C, is suitable.
Technical details
| Temperature range | 30 to 70 °C |
|---|---|
| Control | mechanical, without a digital display |
| Useful volume | 28 l |
| External dimensions (W x D x H) | 580 x 425 x 405 mm |
| Unit weight (net) | 23 kg |
| Connected load | 0.25 kW |
Scope of delivery
- 1x Binder B 28 Standard Incubator with mechanical control (B028-230V)
- Operating instructions
Regulatory information
This device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer, BINDER GmbH, is DE 37004983. Information on the return of old appliances can be found on our page Environment and disposal.
Individual requirements & procurement service
Through our procurement service, we can assist you in sourcing suitable accessories and spare parts, or in determining whether the basic B 28 or an electronically controlled model from the BD or BF series is more suitable for your application. Do you need help making a selection? We’d be happy to assist you via our procurement service.
Frequently Asked Questions
Why does the B 28 not have a digital display?
According to the data sheet, the B 28 is a mechanically controlled legacy model in the BINDER range that deliberately does not feature electronic control technology.
Which standard BINDER incubators feature digital control?
The BD series (natural convection, Avantgarde.Line) and the BF series (forced air circulation) are electronically controlled and are each available in several sizes, from 20 and 59 litres respectively.
Is the B 28 suitable for temperatures below room temperature?
No, according to the data sheet, the temperature range is 30 to 70 °C. For applications below room temperature, a cooling incubator from the KB series is required.
Is the B 28 still worth it despite the lack of a documentation function?
For teaching, training or simple routine tasks that do not require digital recording, the B 28 is, according to the data sheet, a cost-effective basic model; for GLP documentation, an electronically controlled model with a USB interface is the more suitable choice.