Binder KBF 470 Constant-Climate Chamber, 0 °C to 70 °C, 10% to 80% relative humidity, 472 l, 9020-0480
€17,559.00
- Constant climate chamber for temperature and humidity, size 470
- Temperature range 0 °C to 70 °C, humidity 10 % to 80 % RH
- 472 l net volume
- Complies with ICH Q1A requirements for long-term, accelerated and stress tests
- Capacitive humidity control with steam humidification
- Up to 40 per cent energy savings compared with the previous model
- Class 3.3 temperature selector switch in accordance with DIN 12880 with visual and audible alarm
Product information "Binder KBF 470 Constant-Climate Chamber, 0 °C to 70 °C, 10% to 80% relative humidity, 472 l, 9020-0480"
As soon as several test samples need to be stored simultaneously under constant temperature and humidity conditions, a single chamber quickly becomes a bottleneck. With a usable volume of 472 litres, the Binder KBF 470 provides enough space for parallel ICH stability series without reaching the dimensions of a walk-in cabinet. For QC departments running several batches through the stability programme at the same time, this represents a significant increase in capacity compared with more compact models, whilst maintaining the same control accuracy.
The Binder KBF 470 constant-climate chamber is part of Binder’s KBF series and is specialised in the combined control of temperature and relative humidity. The unit covers a temperature range from 0 °C to 70 °C, combined with humidity control from 10 °C to 70 °C at 10% to 80% RH. The KBF 470 thus meets all key ICH requirements for long-term testing, accelerated testing and stress testing in accordance with ICH Q1A, from control precision and programming through to documentation. With optionally available light modules, the unit can also be used as an ICH photostability test cabinet or as a plant growth cabinet, without the need to purchase a separate unit.
Operation, documentation and process reliability
A touchscreen controller with time-interval and real-time programming handles the control functions, whilst the operator terminal can be adjusted ergonomically. Humidity control is provided by a capacitive humidity sensor with rapid-response steam humidification. Process reliability is ensured by the integrated Class 3.3 temperature selector monitor in accordance with DIN 12880, featuring visual and audible alarms, supplemented by a signal triangle with an illuminated status indicator. The unit can be integrated into a network via Ethernet and USB; an internal data logger records measured values in an open format, which can be read directly via USB or using the supplied APT-COM Basic Edition software. Optional software upgrades are available to meet more demanding documentation requirements, extending the functionality of the basic version.
The inner chamber is made of stainless steel; the two inner doors, made of metal oxide-coated safety glass, allow the samples to be viewed without affecting the climatic conditions. Two external and two internal doors, each fitted with a door heater to prevent condensation, together with a robust housing construction featuring HIT sandwich technology, ensure a stable, well-insulated chamber that quickly returns to its set environmental conditions even after frequent door openings. Cooling is provided by a modern inverter chiller using the climate-neutral refrigerant R-600a, which, according to the manufacturer’s data sheet, offers up to 40 per cent lower energy consumption compared with the previous model.
Cost-effectiveness and sustainability in continuous operation
Constant-climate cabinets generally run continuously for weeks or months, so energy consumption has a significant impact on running costs. According to the manufacturer’s data sheet, the modern inverter refrigeration technology with a climate-neutral refrigerant saves up to 40 per cent in energy compared with the previous model, without compromising the control accuracy of temperature and humidity. For laboratories with several climate-controlled cabinets operating in parallel, this difference adds up significantly over the service life; furthermore, the climate-neutral refrigerant reduces the environmental impact compared with older refrigerants.
Typical applications
This medium-sized model already allows a noticeably larger sample volume to be processed in parallel, without reaching the dimensions and space requirements of the largest models in the series.
- Concurrent ICH long-term and accelerated tests on multiple batches
- Routine stability testing in QC departments within the pharmaceutical, food and cosmetics industries
- Material testing under defined climatic conditions in quality assurance
- Photostability tests in accordance with ICH Q1B using an optional light module
With optionally available light modules, the Binder KBF 470 can be expanded to include ICH Q1B-compliant photostability tests or LED plant light modules for plant growth experiments, without having to change the base unit. Two stainless steel insert grids are included as standard; if required, the chamber can be fitted with additional insert grids, including reinforced ones, up to the maximum number permitted. External water supply systems are also available for humidity control, whilst software documentation upgrades are available up to the GLP Edition.
Technical details
| Temperature range | 0 °C to 70 °C |
| Temperature range with humidity control | 10 °C to 70 °C |
| Humidity range | 10 % to 80 % r.h. |
| Useful volume | 472 l |
| External dimensions (W × D × H) | 930 × 900 × 1,951 mm |
| Unit weight (net) | 225 kg |
| Power consumption | 1.4 kW |
| Rated voltage | 230 V |
| Refrigerant | R-600a (climate-neutral) |
| Refrigeration technology | Inverter compressor cooling |
| Humidity sensor | capacitive, with steam humidification |
| Temperature selector switch | Class 3.3 in accordance with DIN 12880, with visual and audible alarm |
| Control | Touchscreen controller with time-based and real-time programming |
| Data interfaces | Ethernet, USB |
| Inner tank | Stainless steel |
| Inner doors | Metal oxide-coated safety glass |
| Racks (standard / max.) | 2 / 16 |
| Max. load per drawer / total | 40 kg / 200 kg |
Contents of delivery
- 1x Binder KBF 470 constant-temperature cabinet, 230 V (9020-0480)
- 2x stainless steel shelf grids
- APT-COM Basic Edition (software for connecting the unit)
- User manual
Additional modules for plant growth, photostability and CO2 gassing


Pictured: size 470 with ICH light module (left, KBF PRO 470) and with LED plant light module (right). The modules are accessories.
The KBF 470 accepts the LED plant light module (8012-2439), the ICH light module (8012-2441) and the CO2 gassing module (8012-2140 or 8012-2138 respectively). With LED light, size 470 reaches a PAR photon flux density of 1,540 µmol/m²/s at a distance of 25 cm, and the temperature and humidity range narrows to 10 °C to 50 °C and 20 to 50 per cent relative humidity. With the ICH module, VIS illuminance is 38 klx and UVA irradiance is 37 W/m², an ICH Q1B test is completed in 38 hours, usable at 20 °C to 50 °C and 20 to 50 per cent relative humidity. The CO2 module operates in the range of 0 °C to 70 °C and 20 to 80 per cent relative humidity. A matching shelf set with U-rails for the LED strips carries item number 8012-2390.
The modules are accessories and not included with the chamber. You will find them with prices under "Matching modules" on this page; more on our Binder page.
Customised requirements & procurement service
A wide range of accessories is available for the Binder KBF 470, such as lighting and LED plant lighting modules, reinforced or additional insert grids, calibration certificates with varying numbers of measurement points, maintenance contracts with different scopes, and external water supply systems for humidity control. Do you require any of these accessories, a bespoke configuration, or assistance in selecting the right unit for your application? Through our procurement service, LT Laborhandel will be happy to assist you with procurement and configuration.
| Volume: | 472 l |
|---|