IKA KS 3000 ic control Incubation Shaker with Cooling Coil, 10 to 500 rpm, up to 80 °C, 50 L, 0003940100
€5,725.50
% Manufacturer's RRP: €7,634.00 25% below manufacturer's RRP
- Incubation shaker with built-in cooling coil for an external cooling unit
- Temperature range: room temperature minus 10 K to 80 °C, setting accuracy 0.1 K
- Speed: 10 to 500 rpm in 1-rpm increments; shaking stroke: 20 mm; capacity: up to 7.5 kg
- Inner chamber: 330 x 330 x 258 mm (50 l), PMMA lid, automatic stop when lid is open
- Interfaces: RS 232 and USB-B; controlled via labworldsoft
- PT 1000.80 temperature sensor and USB-A-B cable included in the scope of delivery
- 3-year manufacturer’s warranty upon registration within 90 days
Product information "IKA KS 3000 ic control Incubation Shaker with Cooling Coil, 10 to 500 rpm, up to 80 °C, 50 L, 0003940100"
It is not possible to maintain the temperature of samples below room temperature using a heater alone. The IKA KS 3000 ic control therefore has a built-in cooling coil with connections for an external cooling unit; IKA cites the RC 2 basic or RC 2 control as examples. With cooling, the temperature range extends from room temperature minus 10 K to 80 °C, provided the inlet temperature is above 3 °C. The incubation shaker performs circular shaking with a 20 mm stroke at 10 to 500 rpm and can hold up to 7.5 kg.
Heating and cooling
An integrated PID control system operates with two PT-1000 sensors; the heating power is 1000 W. The setpoint temperature is adjusted and displayed in increments of 0.1 K. With a sensor in the vessel, the control accuracy is ±0.5 K (1 vessel containing 0.5 l of water, 22 °C room temperature, 37 °C). Temperature stability is ±0.05 K (1 vessel containing 0.5 l, room temperature 25 °C, 37 °C), whilst temperature homogeneity across five vessels, each containing 0.5 l, is ±0.5 K. There is a connection socket for an additional sensor in the working chamber. A stainless-steel PT 1000.80 is included in the Scope of delivery.
Interior, hood and safety features
The inner chamber measures 330 x 330 x 258 mm and has a volume of 50 l. The lid is made of PMMA, whilst the housing is made of powder-coated sheet steel. The unit stops automatically when the lid is opened and switches itself off in the event of a fault. The control elements have an antimicrobial coating to reduce bacteria. A drip tray with a drain hose at the rear collects any liquid. Speed and time are shown on a large LED display. The timer ranges from 1 second to 999 hours; alternatively, the unit can run continuously.
Typical applications
- Shaking temperature-controlled samples for hours in unattended operation
- Incubation at a constant temperature, for example at 37 °C
- Temperature control below room temperature with a connected cooling unit
- Documented runs via RS 232, USB-B and labworldsoft
- Shaking of vessels of various sizes using clamps or a universal adapter, up to 7.5 kg
With or without a cooling coil
If you only need to heat from room temperature plus 5 K, you can opt for the KS 3000 i control. It has the same chamber, the same speed and the same shaking weight, but weighs 35 kg instead of 37 kg. For heavier batches requiring a 20 kg shaking load and a 90-litre chamber volume, the KS 4000 i control is available.
| Model | Temperature range | Shaking weight | Internal chamber | Weight |
| KS 3000 ic control (this unit) | Room temperature minus 10 K to 80 °C (with cooling) | 7.5 kg | 50 l | 37 kg |
| KS 3000 i control | Room temperature plus 5 K to 80 °C | 7.5 kg | 50 l | 35 kg |
| KS 4000 i control | Room temperature plus 5 K to 80 °C | 20 kg | 90 l | 50 kg |
Technical details
| Motion and stroke | circular, 20 mm |
| Shaking weight including attachment | up to 7.5 kg |
| Motor power input / output | 45 W / 10 W |
| Rotational speed | 10 to 500 rpm in 1-rpm increments, deviation 1 % |
| Timer | 1 s to 59,940 min, 7-segment LED, continuous operation possible |
| Duty cycle | 100 % |
| heating power | 1,000 W |
| Temperature range (flow temperature above 3 °C) | Room temperature minus 10 K to 80 °C |
| Setpoint temperature adjustment | in increments of 0.1 K |
| Control accuracy with sensor | ±0.5 K (1 vessel containing 0.5 l of water, room temperature 22 °C, 37 °C) |
| temperature stability | ±0.05 K (1 vessel, 0.5 l, ambient temperature 25 °C, 37 °C), ±0.1 K (0.2 l water, ambient temperature 25 °C, 37 °C) |
| Temperature homogeneity | ±0.5 K (5 vessels, 0.5 l, ambient temperature 25 °C, 37 °C) |
| Cooling | Built-in cooling coil with connections for external cooling |
| Internal chamber (W x H x D) | 330 x 330 x 258 mm, 50 l |
| Materials | Housing: powder-coated sheet steel, cover: PMMA, front panel: painted ABS, front film: polyester |
| Interfaces | RS 232, USB-B |
| Dimensions (W x H x D) | 465 x 430 x 695 mm, 875 mm high with the cover open |
| Weight | 37 kg |
| Operating environment | 15 to 32 °C, up to 80 % relative humidity |
| Protection class | IP 30 (DIN EN 60529) |
| Mains connection | 230 V, 50/60 Hz, 1120 W |
Scope of delivery
- 1 x IKA KS 3000 ic control incubation shaker
- 1 x PT 1000.80 temperature probe, stainless steel
- 4 x clamping screws, short
- 1 x USB A-to-B cable
Lids and the external cooling unit are not included in the Scope of delivery. Lids must be ordered separately to fit the vessels.
Warranty and disposal
IKA manufacturer’s warranty: 2 years; extended to 3 years upon registration at ika.com/register within 90 days of purchase. As an electrical appliance, the KS 3000 ic control must be disposed of via the separate collection scheme for waste electrical equipment after use.
Individual requirements and procurement service
IKA offers the following accessories for this unit: the universal attachment AS 260.1, the clamp holder AS 260.2 with clamps ranging from 10 to 2000 ml, the beaker attachment AS 260.3 and the separating funnel attachment AS 260.5. Also available are the AS 1.60 base holder with AS 1.61 clamping roller, the STICKMAX, an adjustable tube rack, the PC 1.1 cable, an additional PT 1000.80 sensor and labworldsoft in three versions. IKA also supplies factory calibration certificates and IQ/OQ documentation. Our procurement service provides support for attachments and cooling units.
Frequently Asked Questions
How does this unit differ from the KS 3000 i control? The KS 3000 ic control has a built-in cooling coil with connections for an external cooling unit. The temperature range therefore extends down to room temperature minus 10 K, whilst for the KS 3000 i control it starts at room temperature plus 5 K.
Is a cooling unit included? No. The cooling coil is connected to an external cooling unit; IKA cites the RC 2 basic or RC 2 control as examples.
Is a temperature sensor included? Yes, a stainless steel PT 1000.80 is included in the Scope of delivery.
How long is the warranty valid for? IKA’s manufacturer’s warranty: 2 years; extended to 3 years if registered at ika.com/register within 90 days of purchase.