IKA LR 1000.3 laboratory reactor vessel, 1,000 ml, six lid connections, anchor stirrer with flow scraper, 0025001955
€5,061.60
% Manufacturer's RRP: €5,328.00 5% below manufacturer's RRP
- Reactor vessel for the LR 1000 basic and LR 1000 control systems
- Anchor stirrer with flow scraper for viscous media that adhere to the walls
- Six lid connections: two NS 29, two NS 14, two GL 14
- Parts in contact with the product made from AISI 316L stainless steel, FFKM, PTFE and PEEK
- Weight 4.22 kg
Product information "IKA LR 1000.3 laboratory reactor vessel, 1,000 ml, six lid connections, anchor stirrer with flow scraper, 0025001955"
The LR 1000.3 is the second reactor vessel in IKA’s LR 1000 range, designed for the same drive units as the LR 1000.1, but with a different anchor agitator and different lid connections. Instead of the standard version, an anchor stirrer with a flow scraper is fitted, which ensures thorough mixing right up to the glass wall, even with viscous media that tend to stick to the walls.
Vessel for the LR-1000 systems
Like the LR 1000.1, the LR 1000.3 is also compatible with the LR 1000 basic system and the LR 1000 control system; both provide the drive and heating for the vessel. The usable volume is based on the 1,000 ml size of the series; the base unit remains the same for both vessels, only the vessel itself is changed. This means that, if required, an existing LR 1000 system can be supplemented with a second vessel variant for other media without having to purchase a new drive unit. Those who run both low-viscosity and highly adhesive solutions in the laboratory can thus avoid the need for a completely separate system and simply swap the vessel instead.
Anchor stirrer with flow scraper and six lid connections
The anchor stirrer supplied comes with a flow scraper which scrapes the vessel wall whilst stirring, thereby preventing viscous or sticky products from sticking to the glass wall. The lid has six connections, two NS 29, two NS 14 and two GL 14, for sensors, dosing systems or other accessories. For the LR 1000.1, IKA also specifies a vacuum tap integrated into the lid; the manufacturer’s specifications make no mention of this for the LR 1000.3. The two GL 14 connections can be used for hose connections. Parts in contact with the product are made of AISI 316L stainless steel, FFKM, PTFE and PEEK. This vessel also connects to the base unit via the standardised stirrer shaft mount; this means it is possible to switch between the LR 1000 basic and LR 1000 control systems without any modifications to the vessel.
Material resistance
FFKM seals generally offer broader chemical and thermal resistance than standard FPM seals, such as those fitted to the LR 1000.1; this is particularly noticeable when dealing with more aggressive solvents or frequent changes of process medium. PEEK is used for the flow scraper because the material is mechanically robust whilst also being wear-resistant, an important consideration for a component that is constantly guided along the glass wall. AISI 316L stainless steel completes the material specification for the metal parts. Overall, the LR 1000.3 is therefore designed for more demanding media than the standard LR 1000.1 vessel; those who work predominantly with less critical, lower-viscosity solutions will generally find the more affordable standard configuration sufficient.
Typical applications
- Mixing and dispersing viscous, wall-adhering media on a laboratory scale
- Formulation development in cosmetics and pharmaceuticals
- Applications where additional lid connections are required for sensors or dosing
- Preliminary scale-up trials prior to production
Technical details
| Max. capacity | 1,000 ml |
| Stirrer equipment | Anchor stirrer with flow scraper |
| Connections on the lid | 2 x NS 29, 2 x NS 14, 2 x GL 14 |
| Materials that come into contact with the product | AISI 316L stainless steel, FFKM, PTFE, PEEK, borosilicate glass 3.1 |
| Weight | 4.22 kg |
Scope of delivery
- 1 x LR 1000.3 laboratory reactor vessel, 1,000 ml
- 1 x anchor stirrer with flow scraper
The drive is not included. The LR 1000 basic or LR 1000 control system must be ordered separately, as must glass stoppers or accessories for the free lid connections, should these still be missing.
Use and care
The anchor stirrer can be detached from the drive for cleaning, and the vessel itself can be completely dismantled. Those who regularly work with very sticky or highly viscous media will benefit most from the flow scraper; for thinner media, the standard anchor stirrer of the LR 1000.1 is often sufficient. The six lid ports should remain closed when not in use to prevent any liquid or steam from escaping uncontrollably whilst stirring. As with the LR 1000.1, this vessel can also be completely dismantled for thorough cleaning, which is particularly useful after processing highly sticky products.
Individual requirements and procurement service
The LR-1000 range also includes other anchor stirrers, such as the standard stirrer LR 1000.11, made of stainless steel and the LR 1000.10 with PEEK scrapers, and the flow breaker LR 1000.20 to prevent the formation of vortices in the vessel. Through our procurement service, we can assist you in selecting the drive, agitator and other accessories for your LR-1000 system, including helping you decide between the standard version and the flow scraper version.
Frequently asked questions
Is a drive included in the scope of delivery?
No, you will need either the LR 1000 basic or the LR 1000 control system.
What is the difference between the LR 1000.3 and the LR 1000.1?
The anchor stirrer with a flow scraper instead of a standard stirrer and six lid connections instead of four. IKA only specifies a vacuum tap integrated into the lid for the LR 1000.1. Details on the LR 1000.1 can be found on its product page.
What types of lid connections does the vessel have?
Two NS 29, two NS 14 and two GL 14.
How much does the vessel weigh?
4.22 kg, excluding the drive unit and base unit.