Product information "IKA Rotary Evaporator RV 3 V-C, Set with Heating Bath and Coated Glassware, 0010003328"

According to IKA, the coating of the condenser serves as additional splinter protection if the glass breaks under vacuum. The IKA RV 3 V-C rotary evaporator is built on the same drive and heating bath combination as the RV 3 V base package, but replaces the uncoated glassware with coated vertical glassware RV 10.10. The RV 3 eco drive unit with manual lift and the HB eco S099 water heating bath up to 99 °C remain identical, supplemented by an additional NS 29 clamp for the coated glassware. For training laboratories or workstations with higher safety requirements, this is an obvious extra cost compared with the uncoated base package.

Selection guide: RV 3, RV 8 or RV 10, and which specification level?

Within the RV 3 series, the RV 3 V and RV 3 V-C differ only in the glassware version: uncoated for the RV 3 V, coated for the RV 3 V-C. Both share the drive, heating bath, speed range and heating temperature range up to 99 °C. Anyone who needs higher temperatures up to 180 °C will only find this specification from the RV 8 series onwards. The following overview classifies the five common complete packages of the RV series.

Model designationIKA RV 3 V  |  RV 3 V-C  |  RV 8 V  |  RV 10 digital V Starter Solution  |  RV 10 auto pro V-C
Liftmanual | manual | manual (hand lift) | motor with safety stop | motor with safety stop
Control leveleco | eco | heating bath with digital display | digital | auto, with integrated vacuum controller
Condenser coatinguncoated | coated | uncoated | uncoated | coated
Cooling surface1,500 cm² for all five versions
Speed range20 to 300 rpm | 20 to 300 rpm | 5 to 300 rpm | 5 to 280 rpm | 5 to 300 rpm
Stroke150 mm  |  150 mm  |  120 mm  |  140 mm  |  140 mm
Heating temperature rangeRoom temp. to 99 °C | Room temp. to 99 °C | Room temp. to 180 °C | Room temp. to 180 °C | Room temp. to 180 °C
Vacuum pump in setno | no | no | yes, VACSTAR lite with VC 10 lite controller | yes, VACSTAR digital
Recirculating chiller in setno | no | no | yes, RC 2 lite | no

Differentiation within the RV family

Anyone who can do without the glass coating and would like to save a little will find, in the IKA RV 3 V rotary evaporator, the same drive and heating bath combination with uncoated glassware. Anyone who needs higher heating bath temperatures up to 180 °C and a wider speed range is better served by the IKA RV 8 V. For laboratories that also want an integrated vacuum pump in the set, the Pro version IKA RV 3 pro V-C Complete rotary evaporator is the next step up. Since the RV 3 V-C includes neither a vacuum pump nor a recirculating chiller, we recommend the IKA RC 2 lite recirculating chiller, which according to the manufacturer is expressly intended for cooling rotary evaporators. Anyone who is unsure whether the coating is really needed in their own laboratory can compare the two RV 3 versions directly using the identical technical data and base the decision solely on the glass question.

Typical applications

The RV 3 V-C rotary evaporator is suitable for the same applications as the uncoated base package, with the additional safety aspect of the glass coating:

  • Routine solvent evaporation and recovery where additional splinter protection is wanted when working under vacuum
  • Concentrating aqueous samples and extracts as part of sample preparation
  • Teaching and training laboratories in which coated glass is required or recommended for safety reasons
  • Budget-oriented equipping of second or replacement workstations with higher safety requirements
  • Chemistry, pharmaceuticals, bioindustry, research and development, production and quality assurance, and plant engineering as the fields of application named by the manufacturer

Manual vacuum control and the role of the glass coating

As with the uncoated RV 3 V, pressure control without an integrated vacuum controller lies with the separately procured vacuum pump or an upstream vacuum controller. Applying the vacuum slowly and step by step at the start of the process reduces the risk of bumping and mechanical stress on the glass. This is exactly where the coating of the RV 10.10 glassware comes in: it does not replace careful operation, but in the unlikely event of glass breakage under vacuum it serves, according to IKA, as additional splinter protection if the glass breaks under vacuum.

Use, installation and maintenance

The drive unit is designed for ambient temperatures of 5 to 40 °C and a relative humidity of up to 80 %, degree of protection IP 20 according to DIN EN 60529. The manual lift requires somewhat more attention than a motorised lift when raising and lowering the glassware. The additional NS 29 clamp secures the coated RV 10.10 glassware and should be checked regularly for a firm fit, so that the glassware stays securely fixed. The HB eco water heating bath should be checked regularly for water level and limescale deposits. The RV 10.8001 seal on the vapour duct is a wearing part and should be the first thing to check if vacuum tightness declines. The drive unit is operated at 100 to 240 volts at 50 or 60 hertz and draws up to 1,400 watts, so a normal laboratory socket is sufficient for operation. Since the coating is a surface layer on the glass, gentle handling without abrasive aids is advisable when cleaning, so that it reliably keeps its protective function over the entire service life of the glassware and is not damaged prematurely by mechanical abrasion.

Technical details

Condenser typeupright (vertical, coated)
Cooling surface1,500 cm²
Coatingyes
Motor principleDC
Speed range20 to 300 rpm
Speed tolerance (<100 rpm / >100 rpm)±1 rpm / ±1 %
Liftmanual
Stroke150 mm
Heating temperature rangeRoom temp. to 99 °C
Permissible ambient temperature range5 to 40 °C
Permissible relative humidity80 %
IP rating according to DIN EN 60529IP 20
Voltage / frequency100 to 240 V / 50/60 Hz
Device power consumption1,400 W

Scope of delivery

The package includes the RV 3 eco drive unit, the HB eco water heating bath and the coated vertical glassware RV 10.10 (ident no. 0003755400) together with the additional NS 29 clamp (ident no. 0003683300). A vacuum pump and a recirculating chiller are not part of the scope of delivery.

  • 1 x RV 3 eco drive unit
  • 1 x HB eco S099 water heating bath, up to 99 °C, with digital temperature display and carrying handles
  • 1 x RV 10.10 glassware, vertical, coated (ident no. 0003755400)
  • 1 x RV 10.88 clamp NS 29 (ident no. 0003683300)
  • 1 x RV 10.70 vapour duct tube (NS 29/32)
  • 1 x RV 10.8001 seal

Warranty

Manufacturer’s warranty from IKA: 2 years, extended to 5 years upon registration at ika.com/register within 90 days of purchase.

Regulatory information

The RV 3 V-C is an electrical device and is therefore subject to the WEEE Directive, implemented in Germany by the Electrical and Electronic Equipment Act (ElektroG), registered under IKA number DE 66784213. At the end of its service life, the statutory take-back obligation applies, and disposal with household waste is excluded.

What is in the set, what is still missing?

The drive, heating bath and coated glassware are already covered by the RV 3 V-C, but for operation under vacuum a vacuum pump of its own is missing, and for a closed cooling circuit a recirculating chiller such as the IKA RC 2 lite. Anyone who can foresee needing higher heating bath temperatures or an integrated vacuum pump should rather go straight to the RV 8 V or to the Pro version RV 3 pro V-C Complete than retrofit, since the heating bath and drive cannot be replaced afterwards. The extra cost compared with the uncoated RV 3 V is limited to the glassware, and all other investment decisions for vacuum pump and chiller are identical for both versions. Anyone who already operates an uncoated RV 3 V in the laboratory and wants to procure a second device with higher safety requirements can share the vacuum pump and recirculating chiller unchanged between both devices, since the connected load does not change.

Frequently asked questions

  • Why is the glassware coated?
    The coating of the RV 10.10 vertical glassware offers additional splinter protection should the glass break under vacuum.
  • Is a vacuum pump included in the scope of delivery?
    No, the package contains the drive, heating bath and glassware. A vacuum pump has to be procured separately for operation under vacuum.
  • How hot does the heating bath get?
    The HB eco water heating bath heats from room temperature up to 99 °C. For higher temperatures, the RV 8 V with oil heating bath is more suitable.
  • How does the device differ from the RV 3 V?
    Drive, heating bath and speed range are identical. The only difference is the coated instead of uncoated glassware together with the additional NS 29 clamp.
  • Which recirculating chiller suits this device?
    The manufacturer expressly names the cooling of rotary evaporators as a field of application for the IKA RC 2 lite.
  • How is the lift operated?
    The lift is manual, with a stroke of 150 mm, without a motor or programming.
  • Is the extra cost compared with the uncoated model worthwhile?
    That depends on the safety requirements of the respective workstation. Technically, the drive, heating bath and speed range are identical in both versions.
  • Is the additional NS 29 clamp only needed for this device?
    It belongs specifically to the coated RV 10.10 glassware and is therefore part of the scope of delivery of the RV 3 V-C, but not of the uncoated RV 3 V.

Individual requirements & procurement service

We will gladly support you with suitable vacuum pumps, recirculating chillers, spare glassware or wearing parts such as the vapour duct seal through our procurement service.

Skip product gallery

Vacuum pumps and recirculating chillers

Discount Promo
Topseller
IKA VACSTAR lite Starter Solution, diaphragm vacuum pump, including emission condenser, 9 mbar, 0010014496
IKA VACSTAR lite Starter Solution, diaphragm vacuum pump, including emission condenser, 9 mbar, 0010014496
Manufacturer number: 0010014496

The IKA VACSTAR lite Starter Solution (MPN 0010014496) is a pre-assembled entry-level vacuum package for everyday laboratory use: a compact, oil-free diaphragm vacuum pump combined with the VSE 1 emission condenser. For example, anyone working with a rotary evaporator or setting up a filtration system does not need to purchase and set up the condenser separately, but can put the set into operation straight away. The pump thus handles standard tasks such as filtration, drying in a vacuum drying oven or evacuating Schlenk lines. Compact two-cylinder pump with robust suction capacity At its core is a dry two-cylinder diaphragm pump with a maximum pumping speed of 1.0 cubic metres per hour (16.67 litres per minute) and an ultimate vacuum of 9 mbar without gas ballast. The speed can be continuously adjusted via a rotary knob; the speed range is between 285 and 1,100 revolutions per minute, with a rated speed of 1,100 rpm. This is sufficient for most routine laboratory tasks, but is clearly intended for applications that do not require extremely low ultimate vacuums, such as simple filtration or the drying off of solvents at moderate temperatures. VSE 1 emission condenser for solvent vapours The VSE 1 vacuum safety emission condenser included in the set captures solvent vapours before they are released into the room air via the pump. This allows the condensed solvent to be recovered rather than wasted. Particularly when working with volatile organic solvents in fume hoods or on rotary evaporators, this can reduce consumption and the volume of waste to be disposed of, without the need to procure and adapt a separate component. Chemical-resistant and low-maintenance in continuous operation As a dry-running pump, the VACSTAR lite operates entirely without operating oil, thus eliminating the need for oil changes, waste oil disposal and the risk of sample contamination from oil vapours. All parts in contact with the medium are made of Al₂O₃, PTFE, FFPM, PPS and NBR, whilst the housing is made of coated die-cast aluminium and thermoplastic. According to the manufacturer, this combination of materials is designed for use with aggressive chemicals and solvent vapours and can reduce maintenance requirements during continuous operation. Space-saving and easy to integrate Measuring 115 x 292 x 280 millimetres and weighing 8.5 kilograms, the VACSTAR lite fits even on small work surfaces or directly inside a fume hood. Connections are made via 8-millimetre hose connections on the suction and discharge sides; the housing is rated to IP 20. The sound pressure level is 54 dB(A) at low pressure. A USB interface and an analogue input are available for connection to external control systems, for example if a digital vacuum controller is to be retrofitted at a later date. Simple operation with no training required The ‘lite’ version deliberately omits a digital display and focuses purely on functionality: a rotary knob continuously adjusts the speed and thus the pumping capacity, whilst a non-return valve protects the system against backflow when the pump is switched off. This makes the pump particularly suitable for workstations where several people with varying levels of experience use the same unit, for example during practical sessions or in teams with frequently changing personnel. Wide range of applications in everyday laboratory work IKA positions the VACSTAR-lite series as a universal vacuum source for use with rotary evaporators, laboratory reactors, temperature-controlled chambers, centrifuges and other laboratory equipment. Manual operation via the rotary knob means the pump does not require additional control software. For workstations where more precise, automated process control is required at a later stage, an external vacuum controller can be retrofitted via the analogue interface if necessary, without having to replace the pump itself. Typical applications As an entry-level solution for generating vacuum in the laboratory, the VACSTAR lite Starter Solution is particularly suitable for the following applications: Vacuum filtration in routine analysis, for example when filtering precipitates Support for rotary evaporators for moderate distillation tasks Drying of samples or glassware in a vacuum drying oven Evacuating Schlenk lines and simple desiccators An introduction to vacuum technology for training and teaching, thanks to simple rotary knob operation requiring no lengthy familiarisation Technical details Pump type2-cylinder diaphragm vacuum pump, dryMax. pumping speed (50/60 Hz)1.0 m³/h (16.67 l/min)Ultimate vacuum without gas ballast9 mbarStages / cylinders2 / 2Inlet pressure10 to 1,030 mbarSpeed range285 to 1,100 rpm (rated speed 1,100 rpm)ControlContinuously variable speed control via rotary knob, two-point controlSuction/discharge connectionHose nozzle Ø 8 mmMaterials in contact with the productAl₂O₃, PTFE, FFPM, PPS, NBRHousing materialCoated die-cast aluminium / thermoplasticDimensions (W x H x D)115 x 292 x 280 mmWeight8.5 kgDegree of protection according to DIN EN 60529IP 20Sound pressure level at low pressure54 dB(A)Permissible ambient temperature5 to 40 °CPermissible relative humidity80 % (up to 31 °C), decreasing linearly to a maximum of 50 % (at 40 °C)InterfacesUSB, analogue inputVoltage / Frequency100 to 240 V, 50/60 HzDevice power consumption120 W (5 W on standby) Scope of delivery 1 x IKA VACSTAR lite vacuum pump 1 x VSE 1 vacuum safety emission condenser 1 x vacuum hose 1 x power supply unit Operating instructions WarrantyManufacturer’s warranty from IKA: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.Regulatory informationThis device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer, IKA, is DE 66784213. Information on the return of old appliances can be found on our page Environment and disposal.Individual requirements and procurement service If you wish to control the VACSTAR lite automatically at a later date, you can retrofit it with a digital vacuum controller such as the VC 10 lite, for example to set programmed ramp profiles on the rotary evaporator. A Woulff bottle to protect the pump from liquid hammer, as well as other original accessories from the IKA vacuum range, are also available via our procurement service. Further information and contact details can be found on our procurement service page.

Sale price: €1,966.80 Manufacturer's RRP: €2,523.00 22% below manufacturer's RRP
Discount
IKA MVP 10 basic Vakuumpumpe, ölfreie Membranpumpe, IP 54
IKA MVP 10 basic Vacuum Pump, Oil-Free Diaphragm Pump, IP 54, 0003980000
Manufacturer number: 0003980000

The IKA MVP 10 basic is a compact, oil-free diaphragm vacuum pump for straightforward laboratory use. Without a display, without digital interfaces and without a controller, the unit concentrates on pure function: reliably generating vacuum, robustly built and easy to maintain. This makes the MVP 10 basic a pragmatic choice for workstations where a simple vacuum source is needed without control software or a process log behind it, for example as a second or third pump for less critical secondary tasks alongside a precisely controlled main setup. Two-stage pump with solid delivery rate The two-stage, two-cylinder diaphragm pump reaches a maximum delivery rate of 1.7 cubic metres per hour (28.3 litres per minute). The ultimate pressure is 7 mbar without gas ballast and 15 mbar with the gas ballast valve activated. The gas ballast valve is particularly helpful when moist or solvent-containing vapours arise during pumping, as it reduces condensation of these in the pump and attacking the diaphragms in the long term. The permissible inlet pressure ranges from 7 to 1,050 mbar, so the pump is suitable both for initial evacuation and for maintaining an existing vacuum. Chemical resistance through PTFE components throughout All parts in contact with gas are made of PTFE or PTFE compounds, which are resistant to many chemicals. Combined with the dry, oil-free design, oil changes and the disposal of waste oil are eliminated, and at the same time the risk of sample contamination by oil vapours from the pump is reduced. The flat, compact design and the construction built for durability ensure a high ease of servicing in everyday laboratory work, so that maintenance can generally be carried out quickly and without special tools. Degree of protection IP 54 for harsh operating conditions With degree of protection IP 54 according to DIN EN 60529, the MVP 10 basic is protected against dust and splashing water. This also makes it interesting for locations where liquids are occasionally handled or the ambient air is not dust-free, for example in pilot plants or workshop laboratories. The permissible ambient temperature is between 10 and 40 °C at a maximum permissible relative humidity of 80 %, which also allows use in rooms that are less strictly air-conditioned. Compact format for fixed workstations With dimensions of 245 x 155 x 320 millimetres and a weight of 11.5 kilograms, the MVP 10 basic takes up little space and can also be moved between several workstations if required. The connection is made via 10 millimetre hose nozzles on the suction and pressure side, and the speed is constant at 1,380 revolutions per minute in 50 hertz operation and 1,680 revolutions per minute at 60 hertz, without any need for manual speed control. The pump is connected to 230 volts at 50 or 60 hertz with a device power consumption of 180 watts. Deliberate omission of display and interfaces Unlike the VACSTAR series, the MVP 10 basic deliberately dispenses with a display, digital interfaces and a vacuum controller. This reduces not only the purchase price but also the number of potential sources of error and wearing parts that would have to be replaced in the event of service. For applications that do not require finely regulated, documented process control but simply need a reliable vacuum, this is a deliberate and sensible compromise in favour of robustness, easy maintenance and a clearly calculable purchase. Typical applications As a robust, easy-to-operate entry-level pump without additional electronics, the MVP 10 basic is particularly suitable for the following applications: Simple vacuum filtrations in the routine laboratory where a finely regulated, digitally traceable ultimate vacuum depth is not required Suction and evacuation in pilot plants or workshop laboratories with a rougher, less air-conditioned ambient climate Evacuation of desiccators and simple drying setups in routine operation Fixed workstations with several users where a reliable, robust vacuum source without its own user interface is sufficient Teaching laboratories where a robust, easy-to-explain pump with no significant operating effort is required Technical details Pump type2-cylinder diaphragm vacuum pump, dry, two-stageDelivery rate max. (50/60 Hz)1.7 m³/h (28.3 l/min)Ultimate pressure without gas ballast7 mbarUltimate pressure with gas ballast15 mbarSuction stages / cylinders2 / 2Gas ballast valveYesConnection diameter suction/pressure side10 mmInlet pressure7 to 1,050 mbarSpeed (50 Hz / 60 Hz)1,380 rpm / 1,680 rpmSound pressure level at min. pressure65 dB(A)Wetted materialPTFE or PTFE compounds (all parts in contact with gas)Dimensions (W x H x D)245 x 155 x 320 mmWeight11.5 kgPermissible ambient temperature10 to 40 °CPermissible relative humiditymax. 80 %Degree of protection according to DIN EN 60529IP 54Voltage / frequency230 V, 50/60 HzDevice power consumption180 W Scope of delivery 1 x IKA MVP 10 basic Vacuum Pump 1 x vacuum hose 1 x silencer 1 x Y hose connector, 8 mm WarrantyManufacturer’s warranty from IKA: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.Regulatory informationThis device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer, IKA, is DE 66784213. Information on the return of old appliances can be found on our page Environment and disposal.Individual requirements &amp; procurement service Accessories and spare parts for the MVP 10 basic, such as additional hose connectors or replacement diaphragms, are available on request through our procurement service.

Sale price: €1,687.20 Manufacturer's RRP: €2,109.00 20% below manufacturer's RRP
Discount
Topseller
IKA VACSTAR digital Vakuumpumpe, Membranpumpe mit digitaler Drehzahlanzeige, 22 l/min
IKA VACSTAR digital Vacuum Pump, Diaphragm Pump with Digital Speed Display, 22 l/min, 0020016236
Manufacturer number: 0020016236

The IKA VACSTAR digital is a dry 4-chamber diaphragm vacuum pump with digital speed display. Anyone who has so far operated a purely analogue pump without feedback on the current speed can see here at a glance which setting is currently in use, without depending on full automation. The VACSTAR digital is thus positioned between the purely manual VACSTAR lite and the VACSTAR control with integrated vacuum controller: more control than with a purely analogue pump, but without the additional cost of a permanently installed controller when it is not yet needed for the application in question. Digital display with simple turn-and-push operation The parameters are set with a turn-and-push knob, and an LED display shows the current speed in real time. The pumping speed of 22 l/min (1.32 m³/h) and an ultimate vacuum of 2 mbar reliably cover typical tasks such as rotary evaporators, drying ovens or filtrations. The speed range extends from 285 to 1,200 revolutions per minute, regulated by an analogue speed-vacuum control with two-point control for stable, readily reproducible process behaviour. Prepared for later automation An analogue cable for connecting an external vacuum controller of type VC 10 is already included in the scope of delivery. Anyone who wants to run automated processes, for example a programmed distillation ramp, can extend the pump with the VC 10 at any time without having to buy an additional connecting cable and without having to replace the pump itself with another model. For the protection of laboratory air and the environment, the VSE 1 vacuum safety emission condenser is also recommended. It reduces the release of solvent vapours into the room air and can be retrofitted at any time if required. Chemically resistant and designed for continuous operation All parts in contact with the product are made of Al2O3, PTFE, FFPM, PPS and NBR, and the housing of coated die-cast aluminium and thermoplastic. As a dry-running pump, the VACSTAR digital works entirely without operating oil, so oil changes and the disposal of waste oil are eliminated and samples are not contaminated by oil vapours from the pump. This combination of materials makes the pump particularly resistant to aggressive solvents and ensures low-maintenance continuous operation in everyday laboratory work, even with daily changes between different solvents. Connection, format and operating values With dimensions of 150 x 375 x 370 millimetres and a weight of 11.5 kilograms, the VACSTAR digital is designed for a fixed place at the laboratory workstation, for example next to a rotary evaporator or drying oven. It is connected to 100 to 240 volts at 50 or 60 hertz with a device power consumption of 130 watts in operation and 3 watts in standby. Both an RS232 and a USB interface are available for connection to laboratory software, and the housing is classified IP 20. Robust design for daily laboratory use The lower housing made of coated die-cast aluminium in combination with thermoplastic components is designed for daily continuous use in the laboratory. The permissible ambient temperature of 5 to 40 °C and a tolerated relative humidity of up to 80 % at 31 °C, decreasing linearly to a maximum of 50 % at 40 °C, make the pump suitable even for laboratories without continuous air conditioning. With a sound pressure level of 54 dB(A) at minimum pressure, operation next to the workstation remains pleasantly quiet. Typical applications As a digital intermediate step between manual operation and a fully integrated controller, the VACSTAR digital is particularly suitable for the following applications: Rotary evaporator operation with direct reading of the current speed instead of estimating from the scale on the knob Vacuum drying in drying ovens with a traceable speed setting that can be read on the display Vacuum filtration in the routine laboratory where digital control without full automation is already sufficient Laboratory workstations that are to be retrofitted later with a VC 10 vacuum controller for full automation Training and practical courses in which the digital speed display supports participants' understanding of the process Workstations with several users where a traceable speed setting is more important than estimating from a scale Technical details Pump type4-chamber diaphragm vacuum pump, dryDelivery rate max. (50/60 Hz)1.32 m³/h (22 l/min)Ultimate pressure without gas ballast2 mbarSuction stages / cylinders4 / 4Connection diameter suction/pressure side8 mmInlet pressure2 to 1,030 mbarControlTwo-point control, analogue speed-vacuum control, setting via turn-and-push knobSpeed range285 to 1,200 rpmDisplayLEDSound pressure level at min. pressure54 dB(A)Wetted materialAl2O3, PTFE, FFPM, PPS, NBRHousing materialCoated die-cast aluminium / thermoplasticDimensions (W x H x D)150 x 375 x 370 mmWeight11.5 kgPermissible ambient temperature5 to 40 °CPermissible relative humidity80 % (up to 31 °C), decreasing linearly to max. 50 % (at 40 °C)Degree of protection according to DIN EN 60529IP 20InterfacesRS232, USBVoltage / frequency100 to 240 V, 50/60 HzDevice power consumption130 W (standby 3 W) Scope of delivery 1 x IKA VACSTAR digital Vacuum Pump 1 x vacuum hose (1 m) 1 x silencer 1 x USB cable (USB-A to USB-B) 1 x analogue cable for connecting an external vacuum controller (e.g. VC 10) WarrantyManufacturer’s warranty from IKA: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.Regulatory informationThis device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer, IKA, is DE 66784213. Information on the return of old appliances can be found on our page Environment and disposal.Individual requirements &amp; procurement service The VC 10 vacuum controller is available as an extension for fully automatic distillations, and for the protection of laboratory air and the environment we also recommend the VSE 1 emission condenser. Further accessories and spare parts are available on request through our procurement service.

Sale price: €2,428.80 Manufacturer's RRP: €3,036.00 20% below manufacturer's RRP
Discount
Topseller
IKA Recirculating Chiller RC 2 lite, Compact Laboratory Chiller, 400 W Cooling Capacity, 0025006624
IKA Recirculating Chiller RC 2 lite, Compact Laboratory Chiller, 400 W Cooling Capacity, 0025006624
Manufacturer number: 0025006624

Anyone who operates a rotary evaporator, a jacketed vessel or a reflux condenser knows the problem of the open tap water circuit: as the outside temperature rises, the cooling effect falls, and water consumption drives up costs and effort. The IKA RC 2 lite recirculating chiller replaces this open circuit with a closed, PID-controlled refrigeration circuit and delivers up to 400 watts of cooling capacity at 20 °C, constant and independent of the season or the water pressure in the laboratory. Cooling capacity from room temperature down to minus 10 °C The cooling capacity of the RC 2 lite falls as expected as the target temperature drops: 400 watts at 20 degrees, 350 watts at 10 degrees, 250 watts at 0 degrees and still 140 watts at minus 10 °C. The working temperature range extends from minus 10 °C to room temperature, and with an external heater the bath can additionally be operated up to 70 °C. Control is handled by a PID controller with a PT1000 sensor and LED display. The temperature stability is ±0.5 kelvin according to DIN 12876, and the display resolution and setting accuracy are each 0.1 kelvin. Refrigerant R290 and classification to DIN 12876 The refrigerant used is R290, a natural, halogen-free hydrocarbon refrigerant, filled with 76 grams at a maximum permissible pressure of 21 bar. According to DIN 12876, the RC 2 lite is classified as Class I with the marking NFL and is therefore intended for operation with non-flammable liquids. R290 (propane) is itself flammable, so, as with all laboratory equipment using a hydrocarbon refrigerant, we recommend a sufficiently ventilated installation location without open ignition sources in the immediate vicinity of the unit. Recirculating chiller, circulating thermostat or heating bath: choosing the right design Within the IKA temperature control family, three designs can be distinguished: pure recirculating chillers such as the RC 2 lite only cool, cooling and heating circulating thermostats such as the HRC 2 series cool and heat in one unit, and heating baths such as the HB digital heat without an active cooling function. The following overview compares the cooling capacity at different target temperatures: ModelDesign20 °C10 °C0 °C-10 °CHeating powerRC 2 lite (this product)Recirculating chiller400 W350 W250 W140 Wnone (external heater up to 70 °C possible)RC 2 basicRecirculating chiller400 W370 W320 W240 WnoneHRC 2 liteCirculating thermostat400 W350 W250 W100 W1,000 WHRC 2 controlCirculating thermostat400 W370 W320 W240 W1,500 W RC 2 lite, RC 2 basic or RC 2 GREEN control: the right specification level The RC 2 lite is the compact entry-level version of the IKA recirculating chiller series for pure cooling tasks down to minus 10 °C, with the natural refrigerant R290. Anyone who prefers pure cooling with the synthetic refrigerant R134a and a cooling capacity of 400 watts will find it in the IKA RC 2 basic. IKA ceased production of the RC 2 basic on 31 July 2026. Anyone looking for a more powerful version will find it in the IKA RC 2 GREEN control, which likewise uses the natural refrigerant R290 and, according to IKA, has roughly double the output of the previous device generation. If the same unit has to heat actively as well as cool, for example for temperature cycles between minus 10 and 100 °C, the IKA HRC 2 lite is suitable. It belongs to the same series as the RC 2 lite, but with an additional 1000-watt heater and an extended working range. Typical applications As an external cooling source with a closed circuit, the RC 2 lite is suitable for the following, among others: Cooling of rotary evaporators, for example the IKA RV 10 digital V-C or the IKA RV 3 V-C, as a replacement for the open tap water circuit Cooling of reflux condensers in syntheses and extractions Cooling source for devices that dissipate heat via a heat exchanger, for example double-walled grinding vessels, cooled incubators, laboratory reactors or cooling coils Connection, installation and ongoing operation The integrated pressure/suction pump reaches a maximum flow rate of 18 litres per minute at a maximum pump pressure of 0.35 bar on the pressure side and 0.15 bar on the suction side, connected via M16x1 threaded connections. The scope of delivery includes two hose nozzles for DN 8 hoses, which allow standard cooling water hoses to be connected directly. The filling volume of the internal bath is between 1 and 3.5 litres. RS232 and USB-B are available for connection to a PC or process control system, for example for logging temperature profiles. With a noise level of 51 dB(A) and a permissible duty cycle of 100 %, the RC 2 lite is designed for continuous operation in everyday laboratory use. The permissible ambient temperature range is 5 to 32 °C at a maximum of 80 % relative humidity. Which cooling capacity for which rotary evaporator The decisive factor in choosing the right cooling capacity is the target temperature of the respective evaporation process: if a cooling bath at around 0 °C is sufficient, the RC 2 lite still has 250 watts of cooling capacity available, and at minus 10 °C it is 140 watts. The lower the required target temperature or the higher the solvent throughput at the rotary evaporator, the more worthwhile it is to consider a more powerful specification level such as the RC 2 GREEN control. The pump capacity also plays a role when connecting external devices: a maximum flow rate of 18 litres per minute at 0 bar back pressure is sufficient for most laboratory reactors and rotary evaporators at a direct installation distance. With longer hose runs or several consumers connected in series, the actual flow rate falls accordingly because of the rising line resistance, so the shortest possible hose routing lets the full pump capacity reach the consumer. Technical details Device typeRecirculating chillerClassification according to DIN 12876Class I, marking NFLWorking temperature range-10 °C to room temperature (with external heater up to 70 °C)Temperature stability (DIN 12876)±0.5 KTemperature sensorPT1000Display resolution / setting accuracy0.1 KCooling capacity at 20 / 10 / 0 / -10 °C400 / 350 / 250 / 140 WRefrigerantR290, 76 g, max. 21 barPump typePressure/suction pumpMax. pump pressure (pressure / suction side)0.35 bar / 0.15 barMax. flow rate (0 bar back pressure)18 l/minPump connectionsM16x1Filling volume1 to 3.5 lPermissible duty cycle100 %Noise level51 dB(A)InterfacesRS232, USB-BDegree of protection according to DIN EN 60529IP 21Permissible ambient temperature5 to 32 °CPermissible relative humiditymax. 80 %Dimensions (W x H x D)225 x 385 x 430 mmWeight24.5 kgVoltage / frequency / connected load230 V, 50/60 Hz, 250 W (other variants 115 V / 100 V available from IKA) Scope of delivery 1 x IKA RC 2 lite recirculating chiller (ident no. 0025006624) 2 x hose nozzle for DN 8 hoses WarrantyManufacturer’s warranty from IKA: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.Regulatory information As an electrical device, the RC 2 lite is subject to the German Electrical and Electronic Equipment Act (ElektroG) and is registered with Stiftung EAR under WEEE registration number DE 66784213. At the end of its service life, the device must not be disposed of with household waste but must be taken to a separate collection point for waste electrical equipment. The refrigerant R290 contained in the refrigeration circuit must be removed professionally by an approved refrigerant recovery company before disposal. Frequently asked questions about the RC 2 lite Can the RC 2 lite also heat?No, the RC 2 lite is a pure recirculating chiller. Heating the bath above room temperature is only possible with an external heater up to a maximum of 70 °C. If an integrated heater is required, the IKA HRC 2 lite is the suitable alternative. Which hoses fit the RC 2 lite?The pump connections are designed as M16x1 threads, and two hose nozzles for DN 8 hoses are included in the scope of delivery. Is R290 as a refrigerant harmless in everyday laboratory use?R290 is a natural but flammable hydrocarbon refrigerant. For operation, we recommend a sufficiently ventilated installation location without open ignition sources in the immediate vicinity, as is usual for all devices with this type of refrigerant. How loud is the RC 2 lite in continuous operation?The noise level is 51 dB(A), and the device is designed for a duty cycle of 100 %. Can the RC 2 lite be integrated into laboratory software?Yes, the existing RS232 and USB-B interfaces allow the device to be connected to a PC or process control system. How does the RC 2 lite differ from the RC 2 GREEN control?Both are pure recirculating chillers with the natural refrigerant R290. The RC 2 GREEN control is the higher-specification, current version with, according to IKA, roughly double the output of the previous device generation, while the RC 2 lite is positioned as a compact entry-level model for applications down to minus 10 °C. Is the pump capacity sufficient for several connected devices?The maximum flow rate of 18 l/min at 0 bar back pressure applies to a direct connection. With longer hose runs or several consumers in series, the flow actually available falls because of the line resistance, so a short hose routing is preferable. Individual requirements &amp; procurement service For suitable connection hoses, additional valves, adapters or connection to existing laboratory reactors and rotary evaporators, our procurement service will support you. If you have questions about certificates and attestations for the RC 2 lite, please get in touch.

Sale price: €2,093.25 Manufacturer's RRP: €2,791.00 25% below manufacturer's RRP
Discount
IKA RC 5 basic recirculating chiller, high-performance laboratory chiller, 0004181000
IKA RC 5 basic recirculating chiller, high-performance laboratory chiller, 0004181000
Manufacturer number: 0004181000

The IKA RC 5 basic recirculating chiller is a powerful chiller for liquid cooling and the removal of high process heat loads on a laboratory and pilot-plant scale. As a chiller within the IKA range of thermostatic peripherals, this system has been specifically designed for demanding and parallel cooling requirements, such as the simultaneous supply of multiple rotary evaporators, large laboratory reactors, pilot plants or heat-intensive analytical instruments (e.g. electron microscopes, X-ray diffractometers and laser systems). In intensive process separation procedures or exothermic syntheses, a constant and powerful cooling capacity is the primary criterion for achieving temperature-stable condensation rates. Cooling capacity and refrigerant The process engineering foundation of the RC 5 basic is based on a closed, electronically monitored refrigeration circuit with a cooling capacity of up to 1,400 watts (at a medium temperature of 20 °C). With a wide working temperature range from -30 °C to room temperature, the unit is suitable for low-temperature applications. R290 (propane), a natural refrigerant, is used as the refrigerant. The refrigerant has a GWP of 3. Robust fluid mechanics and generous tank capacity The mechatronic design is designed for high hydraulic flow rates. The integrated, high-quality discharge and suction pump delivers a maximum flow rate of up to 31 litres per minute at a maximum discharge pressure of 0.6 bar. This flow rate allows external consumers to be supplied quickly, even over longer hose runs. The bath tank, with a maximum capacity of 7 litres, acts as a thermal buffer. It absorbs thermal load peaks, and the temperature stability is ±0.1 K according to DIN 12876. Media management and occupational safety The RC 5 basic’s user interface impresses with its ergonomically clear layout and intuitive operation. A large, high-contrast LED display shows the setpoint and actual temperatures, as well as the current pump speed, in real time. For optimum media management, the unit features a front-mounted sight glass for continuous monitoring of the fill level, as well as a practical drain port at the rear, which enables a quick and clean change of the temperature control fluid. The safety-oriented system architecture includes integrated dry-run and overheating protection, visual and audible fault alerts, and an easily accessible, cleanable air filter grille for consistent condenser performance. Technical details Temperature control &amp; performance data Cooling function: Recirculating chiller in a closed circuit Working temperature range: -30 °C to room temperature (RT) Cooling capacity at 20 °C (medium): 1,400 W Cooling capacity at 10 °C (medium): 1,200 W Cooling capacity at 0 °C (medium): 950 W Cooling capacity at -10 °C (medium): 650 W Cooling capacity at -20 °C (medium): 450 W Cooling capacity at -30 °C (medium): 200 W Temperature stability according to DIN 12876: ± 0.1 K Refrigerant: R290 (natural refrigerant, GWP=3) Fluid mechanics &amp; pump specifications Pump type: Adjustable pressure and suction pump Max. flow rate (free flow): 31 l/min Max. discharge pressure: 0.6 bar Max. suction pressure: 0.4 bar Minimum bath volume: 5.0 litres Max. bath volume: 7.0 litres Hose connections: M16x1 external thread (hose fittings included) Construction, materials &amp; geometry Housing material: Powder-coated steel and robust composite plastic Overall dimensions (W x D x H): approx. 310 x 490 x 500 mm Net weight (empty): approx. 37.5 kg Degree of protection according to DIN EN 60529: IP 21 Permissible ambient temperature: 5 to 32 °C Electronics, interfaces &amp; safety Display: Large, high-contrast LED display Interfaces: USB-B and RS232 for PC connectivity Safety systems: Integrated dry-run protection, overheating protection, visual/audible fault alarm, level sight glass Mains supply: 230 V / 50/60 Hz Scope of delivery 1 x IKA RC 5 basic recirculating cooler base unit (0004181000) 2 x hose connectors for 8 mm internal hose diameter 2 x hose connectors for 12 mm internal hose diameter 1 x USB cable (A to B) 1 x robust mains cable 1 x Operating instructions Important note: Suitable temperature-control fluids (e.g. water-glycol mixtures) and vacuum- and pressure-resistant connecting hoses are not included in the standard scope of delivery and must be ordered separately according to the specific application. Operation with pure H₂O is only recommended at operating temperatures above 5 °C to avoid the heat exchanger freezing. WarrantyManufacturer’s warranty from IKA: 2 years, extended to 3 years upon registration at ika.com/register within 90 days of purchase.Regulatory informationThis device is an electrical appliance within the meaning of the German Electrical and Electronic Equipment Act (ElektroG). The WEEE registration number of the manufacturer, IKA, is DE 66784213. Information on the return of old appliances can be found on our page Environment and disposal.Individual requirements &amp; accessories Connection components and consumables are also available for the IKA RC 5 basic. For leak-free media transport at low temperatures, we recommend highly flexible, thermally insulated NBR or silicone hoses, including sturdy hose clamps, to minimise condensation build-up in the working environment. For low-temperature operation below 5 °C, the use of genuine IKA coolants (such as Labotherm) is essential to avoid the internal heat exchanger freezing. For seamless integration into automated test profiles, the system can be linked to the IKA laboratory software labworldsoft via the integrated interfaces. Please use our technical procurement service to configure your large-scale cooling system.

Sale price: €4,601.25 Manufacturer's RRP: €6,135.00 25% below manufacturer's RRP