Memmert HPP410eco Constant-Climate Chamber, 384 litres, Peltier technology without a compressor
€13,107.00
- Peltier constant-climate chamber, 384-litre internal volume
- Temperature range 0 to 70 °C; with humidity 5 to 70 °C
- Active humidity control: 10 to 90 % RH
- Up to 14 shelves, total load capacity 200 kg
- ControlCOCKPIT TwinDISPLAY with 2 TFT colour graphic displays
- Designed for stability studies in accordance with ICH Q1A
- Factory calibration certificate included
Product information "Memmert HPP410eco Constant-Climate Chamber, 384 litres, Peltier technology without a compressor"
Contract laboratories and manufacturers running several test programmes simultaneously under ICH conditions need one thing above all else: reliable capacity without compromising on control accuracy. The Memmert HPP410eco constant-climate chamber offers an internal volume of 384 litres and space for up to 14 shelves; temperature and humidity are controlled via a Peltier heating and cooling system that requires no compressor and no conventional refrigerant, with the same control range as the smaller models in the HPPeco range: 0 to 70 °C without humidity control, 5 to 70 °C with active humidity control between 10 and 90 % rh.
Peltier cooling even under heavy loads
Like the other HPPeco models, the HPP410eco heats and cools via a Peltier element integrated into the rear panel; there is no conventional refrigeration circuit with a refrigerant whatsoever. Two DIN Class A Pt100 sensors in a 4-wire configuration monitor each other and automatically take over the function of the other sensor in the event of a fault; with 14 possible racks and a total load of up to 200 kg, this is a crucial feature for long, unattended test runs. The setting accuracy is 0.1 °C; when exposed to light, the operating range narrows to 15 to 40 °C, with a maximum load of 20 kg per shelf.
Humidity control and ControlCOCKPIT TwinDISPLAY
Relative humidity is controlled between 10 and 90 % rh with an accuracy of 0.5 % rh; humidification is provided by a hot steam generator, whilst dehumidification is achieved via a cold trap using Peltier technology. The water supply is provided via an external canister with a connecting hose and a self-priming pump; a fixed water connection is not required. The chamber is operated via the ControlCOCKPIT TwinDISPLAY, which features two TFT colour graphic displays; an Ethernet interface and AtmoCONTROL software are available for documenting multiple parallel test programmes. The SetpointWait function ensures that the test time only begins once the temperature and humidity have actually reached the setpoint.
Selection guide: Choosing the right size within the HPPeco range
With a capacity of 384 litres and 14 shelves, the HPP410eco is one of the larger models among the four chambers compared here:
| Memmert HPP110eco constant-climate chamber | 108 litres, 560 x 480 x 400 mm, approx. 64 kg, up to 5 shelves |
| Memmert Constant-Climate Chamber HPP260eco | 256 litres, 640 x 800 x 500 mm, approx. 94 kg, up to 9 shelves |
| Memmert Constant-Climate Chamber HPP410eco | 384 litres, 640 x 1200 x 500 mm, approx. 134 kg, up to 14 shelves |
| Memmert Constant-Climate Chamber HPP750eco | 749 litres, 1040 x 1200 x 600 mm, approx. 197 kg, up to 14 shelves |
Those who regularly require an even larger sample capacity whilst maintaining a similar number of shelves will find the Memmert HPP750eco Constant Climate Chamber (749 litres) to be the next size up, offering, amongst other things, a higher load capacity per shelf. For smaller, less frequent test runs, the HPP260eco or HPP110eco are often the more economical choice; technically, the only differences between all four models are in volume, dimensions, weight and power consumption. You can find an overview of the entire Memmert range of climate chambers and incubators at LT Laborhandel in the Climate Chambers & Incubators category.
Differences: HPPeco or ICH110?
The Memmert ICH110 climate chamber covers a wider temperature range from –10 to +60 °C and uses a compressor-based, CFC-free R290 system with automatic defrosting; however, at 108 litres, it falls into a significantly smaller volume class than the HPP410eco. For test programmes that remain within the 0 to 70 °C range and process larger batch sizes in parallel, the Peltier technology of the HPP410eco, with a connected load of around 420 W, remains the more energy-efficient option compared to the ICH110’s approximately 1,350 W.
Installation, water connection and drainage
A minimum distance of 15 cm from the wall, a maximum distance of 20 cm from the ceiling and a minimum side clearance of 5 cm must be maintained; the unit may be installed at altitudes of up to 2,000 m above sea level at an ambient temperature of 16 to 40 °C and a maximum relative humidity of 70 per cent, non-condensing. A fixed water connection in the installation room is not required; the supplied water canister with connecting hose provides the water supply for the humidity control. For disposal as waste electrical and electronic equipment (WEEE), Memmert is registered with the Stiftung Elektro-Altgeräte Register (Stiftung EAR) under WEEE registration number DE 66812464.
Investment rationale: Which equipment for which testing purpose
Where several test programmes are being documented in parallel, a USB-to-Ethernet adapter is recommended, together with AtmoCONTROL or myChamber software licences – which can be FDA-compliant for 21 CFR Part 11 environments if required. For long, unattended runs, a potential-free contact for connection to a central control system and a MobileALERT SMS alert system can be added. If several user groups with different access rights are using the device, a lockable door and a USB user ID stick for the TwinDISPLAY are available as options. For permanent installation in the test chamber, a built-in frame with or without ventilation is also available.
Typical applications
With an internal volume of 384 litres and up to 14 shelves, the Memmert HPP410eco constant-climate chamber is designed for contract laboratories and manufacturers running multiple ICH test programmes simultaneously.
- Parallel long-term and intermediate storage studies of multiple active substances in accordance with ICH Q1A
- Stability testing for cosmetic and food batches on an industrial development scale
- Material testing with higher sample throughput in industry
- Environmental testing from freezing point upwards for several parallel test series
Frequently asked questions about the Memmert HPP410eco constant-climate chamber
What temperature and humidity range does the HPP410eco cover?
Depending on the operating mode, 0 to 70 °C without humidity or 5 to 70 °C with active humidity control between 10 and 90 % rh; with light exposure, the operating range is restricted to 15 to 40 °C.
Does the chamber require a fixed water supply?
No. An external water container with a connecting hose supplies the humidity control system via a self-priming pump; a fixed water connection in the installation room is not required.
How many samples can fit into the HPP410eco?
Two shelves are included as standard; a total of up to 14 shelves, each with a maximum load of 20 kg, can be fitted, with the total load not exceeding 200 kg.
When does it make sense to switch to the HPP750eco?
If you regularly require a larger sample volume with a higher load capacity per tray, the HPP750eco, with a capacity of 749 litres and up to 30 kg per tray, offers greater capacity whilst utilising the same control technology.
What distinguishes the HPP410eco from the Memmert ICH110 climate chamber?
The HPP410eco cools between 0 and 70 °C using a Peltier element without a compressor or refrigerant, whilst the ICH110 operates with a compressor-based refrigeration cycle (R290) and also covers a range down to -10 °C, albeit with an internal volume of only 108 litres.
What software is available for documentation and validation?
The chamber can be managed and data read out via Ethernet using the AtmoCONTROL software; for environments where 21 CFR Part 11 compliance is mandatory, Memmert also offers an FDA-compliant licence option.
How is calibration carried out?
The factory calibration certificate covers the standard values of 25 °C at 60 % rh and 40 °C at 75 % rh; in addition, three freely selectable temperature and humidity values each can be calibrated by the user. For DAkkS-accredited calibrations and IQ/OQ/PQ, LT Laborhandel arranges suitable services.
Technical details
| Adjustable temperature range (without light, without humidity) | 0 to 70 °C |
| Adjustable temperature range (with humidity) | 5 to 70 °C |
| Operating temperature range with lighting | 15 to 40 °C |
| Temperature setting accuracy | 0.1 °C |
| Temperature sensor | 2x Pt100, DIN Class A, 4-wire measurement |
| Adjustable humidity range | 10 to 90 % rh |
| Humidity setting accuracy | 0.5% RH |
| Internal volume | 384 l |
| Internal dimensions (W x H x D) | 640 x 1200 x 500 mm |
| External dimensions of the housing (W x H x D) | 824 x 1720 x 655 mm |
| Net weight | approx. 134 kg |
| Power supply 230 V | 50/60 Hz, approx. 420 W |
| Connection 115 V | 50/60 Hz, approx. 420 W |
| Maximum number of trays | 14 |
| Trays included | 2 |
| Max. load on unit | 200 kg |
| Max. load per shelf | 20 kg |
| Housing material | Textured stainless steel housing, fully galvanised sheet steel rear panel |
| Control | ControlCOCKPIT TwinDISPLAY, PID microprocessor controller, 2 TFT colour graphic displays |
| Timer | 1 minute to 99 days, digital countdown timer |
| Permissible ambient temperature | 16 to 40 °C |
| Permissible relative humidity | max. 70% relative, non-condensing |
| Maximum installation altitude | 2,000 m |
| Certifications | CE, EAC, UL marks |
Scope of delivery
- 1x Memmert HPP410eco constant-climate chamber
- Standard factory calibration certificate (25 °C / 60 % rh, 40 °C / 75 % rh)
- Fully insulated stainless steel door with 2-point locking (compression door seal)
- Inner glass door
- Moisture-tight silicone feed-through (internal diameter 18 mm) with silicone plug
- 2x stainless steel grating, electropolished
- Water canister including connection hose
Regulatory information
The Memmert HPP410eco constant-climate chamber is registered with the Stiftung Elektro-Altgeräte Register (Stiftung EAR) under WEEE registration number DE 66812464.
Customised requirements & procurement service
Options available for the HPP410eco include a built-in frame with or without ventilation, a potential-free contact for building management systems, and a lockable door. For data acquisition, a USB-to-Ethernet adapter and AtmoCONTROL and myChamber software licences are available; FDA-compliant licences are also available. In addition, we arrange calibration, IQ/OQ/PQ and maintenance services, including those accredited by DAkkS. Do you require any of these accessories, a special configuration or assistance in selecting the appropriate size for your application? Through our procurement service, LT Laborhandel will be happy to assist you with procurement and configuration.
| Volume: | 384 l |
|---|